Samsung txk2566 service manual

COLOR TELEVISION RECEIVER
Chassis : KS2A(N) Model : TXK2554X/XAA TXK2566X/XAA
TXK2567X/XAA TXK2550X/XAC TXK2554X/XAC TXK2566X/XAC TXK2567X/XAC
COLOR TELEVISION RECEIVER CONTENTS
Reference Information
Specifications
Alignment and Adjustments
Troubleshooting
Exploded Views and Parts List
Electrical Parts List
Block Diagrams
Wiring Diagram
Schematic Diagrams
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
ELECTRONICS
© Samsung Electronics Co., Ltd. OCT. 2000
Printed in Korea
3KS2A(N)-2507
1. Precautions
1-1 Safety Precautions
1. Be sure that all of the built-in protective devices are replaced. Restore any missing protective shields.
2. When reinstalling the chassis and its assemblies, be sure to restore all protective devices, including: nonmetallic control knobs and compartment covers.
3. Make sure that there are no cabinet openings through which people—particularly children—might insert fingers and contact dangerous voltages. Such openings include the spacing between the picture tube and the cabinet mask, excessively wide cabinet ventilation slots, and improperly fitted back covers.
If the measured resistance is less than 1.0 megohm or greater than 5.2 megohms, an abnormality exists that must be corrected before the unit is returned to the customer.
4. Leakage Current Hot Check (Figure 1-1): Warning: Do not use an isolation transformer during this test. Use a leakage­current tester or a metering system that complies with American National Standards Institute (ANIS C101.1, Leakage Current for Appliances), and Underwriters Laboratories (UL Publication UL1410, 59.7).
5. With the unit completely reassembled, plug the AC line cord directly into the power outlet. With the unit’s AC switch first in the ON position and then OFF, measure the current between a known earth ground (metal water pipe, conduit, etc.) and all exposed metal parts, including: antennas, handle brackets, metal cabinets, screwheads and control shafts. The current measured should not exceed 0.5 milliamp. Reverse the power­plug prongs in the AC outlet and repeat the test.
Fig. 1-1 AC Leakage Test
6. Antenna Cold Check: With the unit’s AC plug disconnected from the AC source, connect an electrical jumper across the two AC prongs. Connect one lead of the ohmmeter to an AC prong. Connect the other lead to the coaxial connector.
7. X-ray Limits: The picture tube is especially designed to prohibit X-ray emissions. To ensure continued X-ray protection, replace the picture tube only with one that is the same type as the original. Carefully reinstall the picture tube shields and mounting hardware; these also provide X-ray protection.
8. High Voltage Limits: High voltage must be measured each time servicing is done on the B+, horizontal deflection or high voltage circuits. Correct operation of the X-ray protection circuits must be reconfirmed whenever they are serviced.
(X-ray protection circuits also may be called
“horizontal disable” or “hold-down”.)
Heed the high voltage limits. These include the X–ray Protection Specifications Label, and the Product Safety and X-ray Warning Note on the service data schematic.
Precautions
Samsung Electronics 1-1
LEAKAGE CURRENT
TESTER
DEVICE UNDER
TEST
TEST ALL
EXPOSED METAL
SURFACES
2-WIRE CORD
ALSO TEST WITH
PLUG REVERSED (USING AC ADAPTER PLUG AS REQUIRED)
EARTH
GROUND
(READING SHOULD
NOT BE ABOVE
0.5mA)
Follow these safety, servicing and ESD precautions to prevent damage and protect against potential hazards such as electrical shock and X-rays.
1-1 Safety Precautions (Continued)
9. High voltage is maintained within specified
limits by close-tolerance, safety-related components and adjustments. If the high voltage exceeds the specified limits, check each of the special components.
10. Design Alteration Warning:
Never alter or add to the mechanical or electrical design of this unit. Example: Do not add auxiliary audio or video connectors. Such alterations might create a safety hazard. Also, any design changes or additions will void the manufacturer’s warranty.
11. Hot Chassis Warning:
Some TV receiver chassis are electrically connected directly to one conductor of the AC power cord. If an isolation transformer is not used, these units may be safely serviced only if the AC power plug is inserted so that the chassis is connected to the ground side of the AC source.
To confirm that the AC power plug is inserted correctly, do the following: Using an AC voltmeter, measure the voltage between the chassis and a known earth ground. If the reading is greater than 1.0V, remove the AC power plug, reverse its polarity and reinsert. Re-measure the voltage between the chassis and ground.
12. Some TV chassis are designed to operate with
85 volts AC between chassis and ground, regardless of the AC plug polarity. These units can be safely serviced only if an isolation transformer inserted between the receiver and the power source.
13. Some TV chassis have a secondary ground
system in addition to the main chassis ground. This secondary ground system is not isolated from the AC power line. The two ground systems are electrically separated by insulating material that must not be defeated or altered.
14. Components, parts and wiring that appear to
have overheated or that are otherwise damaged should be replaced with parts that meet the original specifications. Always determine the cause of damage or overheating, and correct any potential hazards.
15. Observe the original lead dress, especially near the following areas: Antenna wiring, sharp edges, and especially the AC and high voltage power supplies. Always inspect for pinched, out-of-place, or frayed wiring. Do not change the spacing between components and the printed circuit board. Check the AC power cord for damage. Make sure that leads and components do not touch thermally hot parts.
16. Picture Tube Implosion Warning: The picture tube in this receiver employs “integral implosion” protection. To ensure continued implosion protection, make sure that the replacement picture tube is the same as the original.
17. Do not remove, install or handle the picture tube without first putting on shatterproof goggles equipped with side shields. Never handle the picture tube by its neck. Some “in-line” picture tubes are equipped with a permanently attached deflection yoke; do not try to remove such “permanently attached” yokes from the picture tube.
18. Product Safety Notice: Some electrical and mechanical parts have special safety-related characteristics which might not be obvious from visual inspection. These safety features and the protection they give might be lost if the replacement component differs from the original—even if the replacement is rated for higher voltage, wattage, etc.
Components that are critical for safety are indicated in the circuit diagram by shading, ( ) or ( ). Use replacement components that have the same ratings, especially for flame resistance and dielectric strength specifications. A replacement part that does not have the same safety characteristics as the original might create shock, fire or other hazards.
Precautions
1-2 Samsung Electronics
1-2 Servicing Precautions
1. Servicing precautions are printed on the cabinet. Follow them.
2. Always unplug the unit’s AC power cord from the AC power source before attempting to: (a) Remove or reinstall any component or assembly, (b) Disconnect an electrical plug or connector, (c) Connect a test component in parallel with an electrolytic capacitor.
3. Some components are raised above the printed circuit board for safety. An insulation tube or tape is sometimes used. The internal wiring is sometimes clamped to prevent contact with thermally hot components. Reinstall all such elements to their original position.
4. After servicing, always check that the screws, components and wiring have been correctly reinstalled. Make sure that the portion around the serviced part has not been damaged.
5. Check the insulation between the blades of the AC plug and accessible conductive parts (examples: metal panels, input terminals and earphone jacks).
6. Insulation Checking Procedure: Disconnect the power cord from the AC source and turn the power switch ON. Connect an insulation resistance meter (500V) to the blades of the AC plug.
The insulation resistance between each blade of the AC plug and accessible conductive parts (see above) should be greater than 1 megohm.
7. Never defeat any of the B+ voltage interlocks. Do not apply AC power to the unit (or any of its assemblies) unless all solid-state heat sinks are correctly installed.
8. Always connect a test instrument’s ground lead to the instrument chassis ground before connecting the positive lead; always remove the instrument’s ground lead last.
Precautions
Samsung Electronics 1-3
Warning1: First read the “Safety Precautions” section of this manual. If some unforeseen circumstance creates a conflict between
the servicing and safety precautions, always follow the safety precautions.
Warning2: An electrolytic capacitor installed with the wrong polarity might explode.
1. Some semiconductor (“solid state”) devices are easily damaged by static electricity. Such components are called Electrostatically Sensitive Devices (ESDs); examples include integrated circuits and some field-effect transistors. The following techniques will reduce the occurrence of component damage caused by static electricity.
2. Immediately before handling any semicon ductor components or assemblies, drain the electrostatic charge from your body by touching a known earth ground. Alternatively, wear a discharging wrist-strap device. (Be sure to remove it prior to applying power— this is an electric shock precaution.)
3. After removing an ESD-equipped assembly, place it on a conductive surface such as aluminum foil to prevent accumulation of electrostatic charge.
4. Do not use freon-propelled chemicals. These can generate electrical charges that damage ESDs.
5. Use only a grounded-tip soldering iron when soldering or unsoldering ESDs.
6. Use only an anti-static solder removal device. Many solder removal devices are not rated as “anti-static”; these can accumulate sufficient electrical charge to damage ESDs.
7. Do not remove a replacement ESD from its protective package until you are ready to install it. Most replacement ESDs are packaged with leads that are electrically shorted together by conductive foam, aluminum foil or other conductive materials.
8. Immediately before removing the protective material from the leads of a replacement ESD, touch the protective material to the chassis or circuit assembly into which the device will be installed.
9. Minimize body motions when handling unpackaged replacement ESDs. Motions such as brushing clothes together, or lifting a foot from a carpeted floor can generate enough static electricity to damage an ESD.
Precautions
1-4 Samsung Electronics
1-3 Precautions for Electrostatically Sensitive Devices (ESDs)
Reference Information
Samsung Electronics 2-1
2. Reference Information
2-1 Tables of Abbreviations and Acronyms
A Ah Å dB dBm
°C °F °K F G GHz g H Hz h ips kWh kg kHz k km km/h kV kVA kW I MHz
Ampere Ampere-hour Angstrom Decibel Decibel Referenced to One Milliwatt Degree Celsius Degree Fahrenheit degree Kelvin Farad Gauss Gigahertz Gram Henry Hertz Hour Inches Per Second Kilowatt-hour Kilogram Kilohertz Kilohm Kilometer Kilometer Per Hour Kilovolt Kilovolt-ampere Kilowatt Liter Megahertz
MV MW M m µA µF µH µm µs µW mA mg mH mI mm ms mV nF
pF Ib rpm rps s V VA W Wh
Megavolt Megawatt Megohm Meter Microampere Microfarad Microhenry Micrometer Microsecond Microwatt Milliampere Milligram Millihenry Milliliter Millimeter Millisecond Millivolt Nanofarad Ohm Picofarad Pound Revolutions Per Minute Revolutions Per Second Second (Time) Volt Volt-ampere Watt Watt-hour
Table 2-1 Abbreviations
Reference Information
2-2 Samsung Electronics
Table 2-2 Table of Acronyms
ABL AC ACC AF AFC AFT AGC AM ANSI APC APC A/V AVC BAL BPF B-Y CATV CB CCD CCTV Ch CRT CW DC DVM EIA ESD ESD FBP FBT FF FM FS GND G-Y H HF HI-FI IC IC IF
Automatic Brightness Limiter Alternating Current Automatic Chroma Control Audio Frequency Automatic Frequency Control Automatic Fine Tuning Automatic Gain Control Amplitude Modulation American National Standards Institute Automatic Phase Control Automatic Picture Control Audio-Video Automatic Volume Control Balance Bandpass Filter Blue-Y Community Antenna Television (Cable TV) Citizens Band Charge Coupled Device Closed Circuit Television Channel Cathode Ray Tube Continuous Wave Direct Current Digital Volt Meter Electronics Industries Association Electrostatic Discharge Electrostatically Sensitive Device Feedback Pulse Flyback Transformer Flip-Flop Frequency Modulation Fail Safe Ground Green-Y High High-Frequency High Fidelity Inductance-Capacitance Integrated Circuit Intermediate Frequency
I/O L L LED LF MOSFET MTS NAB NEC NTSC OSD PCB PLL PWM QIF R RC RF R-Y SAP SAW SIF SMPS S/N SW TP TTL TV UHF UL UV VCD VCO VCXO VHF VIF VR VTR VTVM TR
Input/output Left Low Light Emitting Diode Low Frequency Metal-Oxide-Semiconductor-Field-Effect-Tr Multi-channel Television Sound National Association of Broadcasters National Electric Code National Television Systems Committee On Screen Display Printed Circuit Board Phase-Locked Loop Pulse Width Modulation Quadrature Intermediate Frequency Right Resistor & Capacitor Radio Frequency Red-Y Second Audio Program Surface Acoustic Wave(Filter) Sound Intermediate Frequency Switching Mode Power Supply Signal/Noise Switch Test Point Transistor Transistor Logic Television Ultra High Frequency Underwriters Laboratories Ultraviolet Variable-Capacitance Diode Voltage Controlled Oscillator Voltage Controlled Crystal Oscillator Very High Frequency Video Intermediate Frequency Variable Resistor Video Tape Recorder Vacuum Tube Voltmeter Transistor
REMARK
Refer to Table 2-3-1
Refer to Table 2-3-2
VM Option
DH01
Option
DDR01
LOC. NO
IC201S
IC601 IC901 IC902
IC602
HIC201
IC301
Q401 D409
IC401
Q404
IC801S
D801S
PC801S
IC805
D806 D807 D805
IC804 IC803
IC903 IC904
Q909 Q910
TU01 D813
Table 2 - 3 IC Line - Up
NO
1
Reference Information
Samsung Electronics 2-3
2-2 IC Line Up
BOARD
MAIN
SPEC
VDP3112B
MSP3440D
SDA555X
KS24L161
TDA7297 DRGB001
LA7845
KSD5703
FMP-3FU
KA393 IRF620
3S1265R
RBV606 PC123Y
KA78R05
FML-G12S
FMG-G26S
KA7806
KA78R08
KA78RM33 KIA7025AP
2N7000
TCPN3081PA09A(S)
FML-G12S
DESCRIPTION
Video Processor NTSC Sound Processor MICOM, Caption (MTP)
EEPROM Audio AMP
RGB Drive AMP Hybrid IC Vertical IC
Horizontal Drive IC
E/W Drive IC
SPS Controllor Bridge Diode
Photo Coupler 5V Controlled Regulator
Rectifier Diode
6V Regulator 8V Controlled Regulator
3.3V Regulator MICOM Reset IC
IIC Level Shifter
Main Tuner with IF Block Rectifier Diode
2-4 Samsung Electronics
Table 2 - 3 IC Line - Up
DESCRIPTION
Video Output AMP R.G.B Drive
Push-Pull (VM)
Video Switching IC with Adder Output High-end Picture-In Picture IC
LOC. NO
IC501 IC502 IC503
QF04 QF05
ICS01 ICP01
SPEC
TDA6101Q
2SC2344 2SA1011 TEA6425
SDA9388X
REMARK
Option
Option Option
BOARD
CRT
V-S/W
PIP
Reference Information
NO
2
3 4
SPEC
VDP3108B VDP3130Y
FUNCTION
Basic 1H Comb Filter 2H Comb Filter, DVD Input
REMARK
Table 2-3-1 VIDEO IC
SPEC
TDA7297
TDA7266S
FUNCTION
7W x 2CH, 10W x 2CH 3W x 2CH, 5W x 2CH
REMARK
Table 2-3-2 SOUND AMP
Specifications
Samsung Electronics 3-1
3. Specifications
Specifications are subject to change.
Television
System
Antena Input
Multi
Power
Consumption
Requirements
Frequency
Sound
Output
Effect
Jacks
Front
(AV2)
Back
NTSC-M, PAL N.M
160W (Applied When 29” Flat) Free Volts(100V-240Volts) Free Voltage 50/60Hz 15W x 2CH 10W x 2CH
5W x 2CH Vitual Dolby Turbo Sound Pseudo Stereo RCA Input
S-VHS Head-Phone
2 AV Input
DVD Input(YPbPr) AV2 Monitor Audio Output
S-VHS
75ohms, Coaxial Cable
Not Present R815
Option
Option
Option
Option Option
Option
Option Option
3-2 Samsung Electronics
MEMO
Alignment and Adjustments
Samsung Electronics 4-1
4. Alignment and Adjustments
4-1 General Alignment Instructions
1. Usually, a color TV-VCR needs only slight touch-up adjustment upon installation. Check the basic characteristics such as height, horizontal and vertical sync and focus.
2. Observe the picture for good black and white details. There should be objectionable color shading; if color shading is present, demagnetize, perform purity and convergence adjustments described below.
3. Use the specified test equipment or its equivalent.
4. Correct impedance matching is essential.
5. Avoid overload. Excessive signal from a sweep generator might overload the front-end of the TV. When inserting signal markers, do not allow the marker generator to distort test results.
6. Connect the TV only to an AC power source with voltage and frequency as specified on the backcover nameplate.
7. Do not attempt to connect or disconnect any wires while the TV is turned on. Make sure that the power cord is disconnected before replacing any parts.
8. To protect against shock hazard, use an isolation transformer.
4-2 Automatic Degaussing
A degaussing coil is mounted around the picture tube, so that external degaussing after moving the TV should be unnecessary. But the receiver must be properly degaussed upon installation.
The degaussing coil operates for about 1 second after the power is switched ON. If the set is moved or turned in a different direction, the power should be OFF for at least 10 minutes.
If the chassis or parts of the cabinet become magnetized, poor color purity will result. If this happens, use an external degaussing coil. Slowly move the degaussing coil around the faceplate of the picture tube and the sides and front of the receiver. Slowly withdraw the coil to a distance of about 6 feet before turning power OFF.
If color shading persists, perform the following Color purity and Convergence adjustments.
4-3 High Voltage Check
CAUTION : There is no high voltage adjustment on this chassis. The B+ power supply should be +135 volts (with full color- bar input and normal picture level).
1. Connect a digital voltmeter to the second anode of the picture tube.
2. Turn on the TV. Set the Brightness and Contrast controls to minimum (zero beam current).
3. Adjust the Brightness and contrast controls to both extremes. Ensure that the high voltage does not exceed 30 KV under any conditions.
Alignment and Adjustments
4-2 Samsung Electronics
4-5 SCREEN Adjustment
1. Input Toshiba Pattern
2. Enter “Service Mode”.(Refer to “4-8-1 Service Mode”)
3. Select “G2-Adjust”.
4. Set the values as below.
4-4 FOCUS Adjustment
1. Input a black and white signal.
2. Adjust the tuning control for the clearest picture.
3. Adjust the FOCUS control for well defined scanning lines in the center area of the screen.
5. Turn the SCREEN VR until “MRCR G B” and “MRWDG” are green and those value are about 100. (The incorrect SCREEN Voltage may result that “MRCR G B” and “MRWDG” should be red)
INCH / CRT
14” / SDI
15PF / SDI 21” 1.7R / SDI 20V 10.0R/SDI
21PF / TSB
21PF / LG
21PF / SDI
25PF / SDI 27V 1.3R / SDI
27V 1.0R/SDI 25V 1.0R/SDI 23V 1.3R/SDI
No
1 2
3 4
5 6
7 8
9
10 11
12
IBRM
205 220 220 205
220 230 220 210
210 210
210 205
WDRV
35 35 35 35
35 35 35
35 35
35 35
35
CDL
100 180 180 115
180 230
210 160 170
150 150
120
COLR G B
(Smallest Value)
100 100 100
120
65 65
65 120 150
180 180
140
Table 1. Screen Adjustment Table
REGION
Normal
Alignment and Adjustments
Samsung Electronics 4-3
4-6 E2PROM (IC902) Replacement
1. When IC902 is replaced, all adjustment data revert to the initial values. So, all adjustment values when servicing should be readjusted.
2. After IC902 is replaced, connect the AC power supply cord.
3. Turn the power switch ON.
4. In stand-by, warm up the TV for at least 10 seconds.
5. Power on the TV.
4-7 White Balance Adjustment
Equipment : Color-Analyzer (CA-100)
Input Signal : Pattern signal (Toshiba pattern)
1. Select STANDARD from the menu.
2. Input an 100% White pattern.
3. Enter the “Service Mode”. (Refer to “4-8 Service Mode”)
4. Warm up the TV set at least for 30 minutes.
5. Input a Toshiba pattern signal.
6. Enter the “Video Adjust1”.
- Adjust “Sub Contrast” so that Y (luminance) becomes 65 ft ± 3.
- Use “Red Drive” and “ Blue Drive” to adjust High-Light (x : 265, y : 265)
- Adjust “Sub Bright” so that Y (luminance) becomes 1.2ft ± 0.3.
- Use “Red Cutoff” and “Blue Cutoff” to adjust Low-Light (x : 265, y : 265).
7. Adjust CA-100 so that the final adjustment value can be fixed.
8. Use the Channel Up/Down (▲/▼) buttons to move the cursor on the adjustment modes.
9. Use the Volume +/- buttons to change the adjustment value.
Alignment and Adjustments
4-4 Samsung Electronics
4-8 Factory Adjustment
1. To enter the “Service Mode”, Press the remote-control keys in this sequence :
- If you do not have Factory remote-control
- If you have Factory remote-control
2. After the Service Mode is entered, the initial screen is as shown in the figure below.
3. Use the Channel Up/Down buttons to move the cursor in the adjustment parameters.
Note :
- When CRT, CRT PCB, FBT, E
2
PROM (sometimes MICOM) is replaced, the adjustment values
should be controlled.
- After the Service adjustment is completed, Do not select “Reset” in the service mode menu.
(After above procedure is done, power is on initially and the “Plug and Play” will be operated.)
4-8-1 Service Mode
*
These hexa digits are check sum value which depends on the MICOM version. If check sum value is changed, the value of
E
2
PROM Data newly initialed.
PICTURE OFF PICTURE ON
PICTURE ON
MUTE 1,8,2
DISPLAY
()
FACTORY
xx xx xx
*
Alignment and Adjustments
Samsung Electronics 4-5
4-8-2 Deflection (Memory Data)
- SIM408A USA, LATIN FACTORY (VDP IC VDP3108B)
15" FLAT
H Bow
H SYMMETRY H CORNER
PIP TINT
PIP H.POS
SIM-408A USA,LATIN FACTORY (VDP IC VDP3108B)
Model
4-8-2(A) GEOMETRIC ADJUSTMENT VALUE
INCH
Model
DEFLECTION INIT H Bow H Angle 0 FIX 0 0 0 0 0 0 H Dscc 0 FIX 3 3 3 3 3 3 V SHIFT -40 Control -27 -24 -18 -18 -40 -35 V AMP 5 Control -50 -41 18 18 5 20 V SLOPE -2 Control -7 -4 -4 -4 -2 -4 V SC -7 FIX 0 -13 -13 -13 -13 -13 H EW 64 Control 10 -37 64(FIX) 64(FIX) 64(FIX) 64(FIX) H TRAPEZIUM -20 Control -82 -48 -20(FIX) -20(FIX) -20(FIX) -20(FIX) H PARABOLA -13 Control -89 -44 -13(FIX) -13(FIX) -13(FIX) -13(FIX) H SYMMETRY H CORNER H SHIFT 4 Control 0 8 13 13 4 13 PIP CONTRAST FIX 0 0 0 0 0 0 PIP TINT PIP PAL V.POS FIX 12 12 12 12 12 12 PIP NTSC V.POS FIX 12 12 12 12 12 12 PIP H.POS
0 FIX 0 0 0 0 0 0
13 FIX 13 13 13 13 13 13 15 Control 0 69 69(FIX) 69(FIX) 69(FIX) 69(FIX)
FIX 0 0 0 0 0 0
FIX 12 12 12 12 12 12
27V 1.3R 23V 1.3R 25V 1R 27V 1R 20V 1R 15" FLAT
TXK2767 CL25D4W
TXK2550 TXK2554 TXK2566 TXK2567
CL663BW
TXK2750 TXK2754
TXK2060 TXK2066 TXK2067
CT-15A8
Loading...