INSTALLATION AND OPERATION MANUAL TER-F01 SERIES
TER-F01 Series
10/100 MBPS ETHERNET REPEATER WITH 60 W PASSTHROUGH POE
This manual serves the following
Model Names:
TER-F01
TER- F01PD
The TER-F01 series is an Ethernet repeater supporting up to 60 watts of Pass-through
PoE, providing a simple and cost-effective way to extend Ethernet signals beyond
the standard Ethernet 328 foot (100 meter) limit. The TER-F01 can be used to
double the distance to 656 feet (200 meters) or multiple units can be combined in
series with each unit providing an additional 328 feet (100 meters). The TER-F01 is
powered by pass-through PoE from a PoE switch or midspan injector, requiring no
local power. Low power consumption ensures that maximum power is made
available to the remote PD device.
The standard configuration passes through the PoE to the next device, or as a PD
model, which acts as the final PoE unit in the chain and does not pass through the PoE.
INS_TER-F01[PD] 08/12/19 PAGE 1
INSTALLATION AND OPERATION MANUAL TER-F01 SERIES
FIGURE 1 – TER-F01[PD] EXTENDER
ETHERNET ETHERNET
Power: Supplied by PSE
Note: Ports are universal, and either can be used as in or out.
FIGURE 3 – INDICATING LEDS
COPPER
GREEN
YELLOW
Solid – No Activity
Blinking – Ac tivity
Highest Data Rate
(100Mb)
Power Consumption: <1 W
FIGURE 4 - DIMENSIONS
Dimensions are for a tube module
[3.3 in]
3.2 cm
[1.25 in]
INSTALLATION CONSIDERATIONS
The TER-F01[PD] is supplied as a 3.3 × 1.25 × 1.25 in (8.4 × 3.2 × 3.2 cm) tube
module.
Units should be installed in dry locations protected from extremes of temperature
and humidity.
WARNING: Unit is to be used with a Listed Class 2 power supply.
[1.25 in]
IMPORTANT SAFEGUARDS:
A) Elevated Operating Ambient - If installed in a closed or multi-unit rack
assembly, the operating ambient temperature of the rack environment may
be greater than room ambient. Therefore, consideration should be given to
installing the equipment in an environment compatible with the maximum
ambient temperature (Tma) specified by the manufacturer.
B) Reduced Air Flow - Installation of the equipment in a rack should be such
that the amount of air flow required for safe operation of the equipment is not
compromised.
INS_TER-F01[PD] 08/12/19 PAGE 2