Samsung SSA-P102T-N Specsheet

SSA-P102

SSA-P102T

Access Control Panel

user manual

imagine the possibilities

Thank you for purchasing this Samsung product. To receive more complete service,

please visit our website.

www.samsungsecurity.com

safety information

CAUTION

RISK OF ELECTRIC SHOCK.

DO NOT OPEN

CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK) NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.

This symbol indicates that dangerous voltage consisting a risk of electric shock is present within this unit.

This exclamation point symbol is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance.

WARNING

• To reduce the risk of fire or electric shock, do not expose this appliance to rain or moisture.

WARNING

1.Be sure to use only the standard adapter that is specified in the specification sheet. Using any other adapter could cause fire, electrical shock, or damage to the product.

2.Incorrectly connecting the power supply or replacing battery may cause explosion, fire, electric shock, or damage to the product.

3.Do not connect multiple controllers to a single adapter. Exceeding the capacity may cause abnormal heat generation or fire.

4.Securely plug the power cord into the power receptacle. Insecure connection may cause fire.

5.When installing the controller, fasten it securely and firmly. The fall of controller may cause personal injury.

6.Do not place conductive objects (e.g. screwdrivers, coins, metal parts, etc.) or containers filled with water on top of the controller. Doing so may cause personal injury due to fire, electric shock, or falling objects.

7.Do not install the unit in humid, dusty, or sooty locations. Doing so may cause fire or electric shock.

8.If any unusual smells or smoke come from the unit, stop using the product. In such case, immediately disconnect the power source and contact the service center. Continued use in such a condition may cause fire or electric shock.

9.If this product fails to operate normally, contact the nearest service center. Never disassemble or modify this product in any way. (SAMSUNG is not liable for problems caused by unauthorized modifications or attempted repair.)

10. When cleaning, do not spray water directly onto parts of the product. Doing so may cause fire or electric shock.

CAUTION

1.Do not drop objects on the product or apply strong blows to it. Keep away from a location subject to excessive vibration or magnetic interference.

2.Do not install in a location subject to high temperature (over 50°C), low temperature (below 0°C), or high humidity. Doing so may cause fire or electric shock.

3.If you want to relocate the already installed product, be sure to turn off the power and then move or reinstall it.

4.Remove the power plug from the outlet when there is a lighting storm. Neglecting to do so may cause fire or damage to the product.

2_ safety information

5.Keep out of direct sunlight and heat radiation sources. It may cause fire.

6.Install it in a place with good ventilation.

7.Avoid aiming the controller directly towards extremely bright objects such as sun.

8.Apparatus shall not be exposed to dripping or splashing and no objects filled with liquids, such as vases, shall be placed on the apparatus.

9.The Mains plug is used as a disconnect device and shall stay readily operable at any time.

FCC Statement

Caution : Any changes or modifications in construction of this device which are not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

Note : This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

IMPORTANT SAFETY INSTRUCTIONS

1.Read these instructions.

2.Keep these instructions.

3.Heed all warnings.

4.Follow all instructions.

5.Do not use this apparatus near water.

6.Clean only with dry cloth.

7.Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.

8.Do not install near any heat sources such as radiators, heat registers, or other apparatus (including amplifiers) that produce heat.

9.Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong is provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.

10.Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.

11.Only use attachments/accessories specified by the manufacturer.

12.Use only with cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with

the apparatus.

13.Unplug this apparatus when a card is used. Use caution when moving the cart/ apparatus combination to avoid injury from tip-over.

14.Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as powersupply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.

INFORMATION SAFETY

English _ 3

contents

PRODUCT INTRODUCTION

5

INSTALLATION AND EXTERNAL CONNECTION

10

INITIALIZATION

19

TROUBLESHOOTING

21

PRODUCT SPECIFICATIONS

23

5Features

6What’s included

9Cable Selection

10Connecting the termination resistor and diode

11Earth-grounding the communication cables

12Power, Reader, and I/O Connection

15 Communication Line Connection

19System Initialization

19Reader Input Bit Setup

20Board ID Setting

20Communication Speed Setup

21Troubleshooting

23 Product Specifications

4_ contents

product introduction

FEATURES

This is a state-of-the-art single door access controller device that provides a high level security system in an affordable price, meeting the needs in the security industry. With its user-friendly interface, this product enables user manipulation easy and simple for whatever you want to perform in a high level of stability.

With its user-friendly interface, it can register cards between 10,000 and 50,000, within which you can change, delete, and add them. The built-in event memory can save up to 50,000 instances of entires and alerts according to the number of registered cards. (However, the sum of the registered card count and the event count can not exceed 60,000.) And it also supports a separate event storage system for an input device that detects the most urgent events such as fire sensor and emergent input key preceding over other events from a remote site

You can connect a wide range of readers via the two reader ports, and operate the product in RF Card and RF Card + PW modes. 5 independent input ports can be used to connect to various devices such as Exit Buttons, Door Contact Sensors, PIR Sensors, and Window Breakage Sensors to reinforce security; this product is designed to detect any of these sensors cut off or short-circuited.

You can establish the independent or network connection via RS-232 or RS-422 communications. SSA-P102T is equipped with a built-in TCP/IP module, which enables you to establish LAN communications. All settings including card registration information, I/O settings, Real Time Clock, Time Schedules and all Event Transaction Reports can be downloaded /uploaded from/to the host computer with software supporting a variety of reporting formats. Installed and managed inside the security zone for preventing the risk of damage, this product can implement a high level security access control system with multiple control options, best fit for access control and time & attendance management.

Standalone Operation

As it is equipped with two card readers, you can use this product to control the access on a single door. This controller determines to allow access by reading data from the card reader, and controls the open/close of the door relay and enables you to change other output settings. Upon receipt of an incoming external input signal (sensor or Exit button), it launches an output device such as the relay. This controller has an independent control system, assuring a normal operation regardless of problems on any other systems and, not affecting them in the reverse situation.

Data Maintenance

In the event of power failure, the controller retains all card information (user data) and the access/alert history (event data) until it is damaged on the memory.

Anti-Pass Back

A door has two card readers installed: one for the entrance, and the other for the exit, so anyone who enters should recognize his/her card on the reader at the entrance time before he can exit normally. If a person does not go under the card recognition process and just follows another person’s way inside the door, the person is not allowed to exit when he/she recognizes the access card on exit card reader, and the anti-pass-back error (APB error) occurs which will be saved into the internal memory. And you can configure to output a signal through a specific pin when such an error occurs.

(Make your setting in the Application program (controlled access, time and attendance management, etc) – I/O Setup – APB Error)

Computer-based Management

All records of authorized or unauthorized accesses and any external signal will be saved in the internal memory. You can download such data onto your computer according to the specified communications protocol. With the downloaded data, you can store, process, create a report based on your query (access and alert details, etc) on the central computer.

Input Port Format Setup

It is equipped with 5 built-in input ports, 2 relay output ports, and 2 TTL output ports. You can use the input ports to receive signals from the Exit button and the fire sensor, and utilize this product to meet various situations such as attaching the door lock to any of the two relays. You can also set the output time for these output ports.

INTRODUCTION PRODUCT

English _ 5

product introduction

Time Scheduling

You can specify a time range during which a specific operation is performed. You can specify a specific time range for a schedule code, which will be transferred to the applicable device. You can specify up to 5 different time ranges for a day, ranging from Monday to Sunday including holidays. Each time schedule code can be applied with a single different (or same) holiday code.

Door Open Alarm and Forced Door Open Alarm

The Door Open Alarm function notifies the administrator that the door is still open if a door stays open after the normal door open time and the standby time (default: 3 seconds). (The output signal can be transferred via the output port, data on any abnormal state will be stored in memory, which will be transferred upon request from the PC software. The Forced Door Open Alarm function produces an alert when the Door Contact Sensor senses any forced opening of the door. (In case of a forced opened door, the product does not check the time out.)

Holiday Setup

You can specify a holiday (legal holiday or bi-weekly holiday) excluding Sunday. You can specify up to 32 holidays for a single holiday code. (Access can be permitted only for an allowable time range according to your time schedule setting) A holiday code can be assigned to the time schedule code.

Duress Mode

This is used in a situation where you should open the door inevitably by a robber insisting to do so. Open the door by entering the two-digit duress alarm password and pressing the button before presenting the registered card (or recognizing the card number), in the meantime this forcibly duress situation will be notified to the PC application. (This mode is enabled only if the product is connected to a key-based reader.)

M All of the above mentioned functions can be enabled using the application (SAMS Basic).

WHAT’S INCLUDED

Check if the following items are included in the product package.

x Gn

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Main Unit

 

 

Quick Guide

CD Manual

Diode (x2)

Resistor (x5)

(UF4004, 1N4001~4007)

(2.2kΩ, 1/4W)

6_ product introduction

Samsung SSA-P102T-N Specsheet

Main Board

2

3

4

5

6

1

 

 

 

14

 

 

 

 

13

 

 

 

 

30

 

 

 

 

7

 

 

 

20

8

 

 

 

21

 

 

 

 

9

 

 

 

22

 

 

 

 

10

 

 

 

11

 

 

23

 

 

 

12

 

 

24

 

 

 

 

 

 

17

15

 

 

25

 

 

 

18

 

 

 

 

 

 

26

16

 

 

 

19

27

28

29

1 Fixing Hole

Used to attach SSA-P102 to the closure using a metal supporter. (Ensure that you use the metal supporter to prevent the EMI.)

2 2Pin DIP Switch

Used to set the type of a connected reader to either 26bit Wiegand or 34bit Wiegand.

3 8Pin DIP Switch

The device address and communication speed specified by the applicable switch should be consistent with those of the computer that is used for communications.

(Address Setting: Pin 1 to Pin 5 of the DIP Switch, Communication Speed: Pin 6 to Pin 8 of the DIP Switch)

Pressing both of the switches at the same time for about 2 seconds will sound

4 System Initialize Switch initialization ready beep. Releasing both switches will stop the beep, and restarts the system after the initialization.

5

RJ-45

Connect the LAN cable for TCP/IP communications.

6

LED

Indicates the state of the LAN communications.

7 RL#1, RL#2

Ports where the buzzer control line or the LED control line of the reader is connected to display the operation status of Relay 1 or Relay 2.

8

Input #5

Input Port: The flashing LED indicator denotes that a signal is sensed by the port.

9

Input #4

Input Port: The flashing LED indicator denotes that a signal is sensed by the port.

 

 

 

INTRODUCTION PRODUCT

English _ 7

product introduction

10

Input #3

Input Port: The flashing LED indicator denotes that a signal is sensed by the port.

11

Input #2

Input Port: The flashing LED indicator denotes that a signal is sensed by the port.

(connected to the Door Contact Sensor.) All other sensors are not allowed.

 

 

12

Input #1

Input Port: The flashing LED indicator denotes that a signal is sensed by the port.

(connected to the Exit button.) All other input sources are not allowed.

 

 

13

MCU Module

MCU module connection port. Do not disassemble it at will.

 

Connection Port

 

14

TCP/IP Module

SSA-P102T comes with the TCP/IP module.

 

Connection Port

 

15

Reader #2

Reader port.

 

 

 

16

Reader #1

Reader port.

 

 

 

17

BUZZER

It will sound beeps on system initialization to the configured output depending on the

buzzer control settings.

 

 

18

LCD Connection Port

Optional item.

 

 

 

19

Keypad Connection Port

Optional item.

 

 

 

20

Power Connection Port

SSA-P102 uses DC +12V for its power source.

 

 

 

21

TTL Output #1

TTL output port.

 

 

 

22

TTL Output #2

TTL output port.

 

 

 

23

Relay Output #1

Relay output port.

 

 

 

24

Relay Output #2

Relay output port.

 

 

 

25

RS-232

RS-232 communication port. Used to exclusively connect to a PC in a local area.

 

 

 

26

RS-422

RS-422 communication port. Used to connect to a PC in a remote area. You can

establish up to 32 multi-drop communications.

 

 

27

Power LED

Displays the status of the power supply.

 

 

 

28

RX LED

Displays the signal reception status while in communications.

 

 

 

29

TX LED

Displays the signal transmission status while in communications.

 

 

 

30

MCU Module

MCU module.

 

 

 

8_ product introduction

Loading...
+ 16 hidden pages