Samsung SPR5150 Reference Information

4
. Test Mode
1
. Structures of TEST PROGRAM
1.1
1.1.1
Neccessary files for executing program
Following files should be installed for TEST PROGRAM execution
- JIGPCx.EXE : TEST execution program
- BASEEMC.DAT : stores the EMC code of Baseset
- HANDEMC.DAT : stores the EMC code of Handset
- BASEFLAG.DAT : stores the Flag information for requesting the new EMC code of
- HANDFLAG.DAT : stores the Flag information for requesting the new EMC code of
- IPEI.DAT : stores the IPEI currently working
- RFPI.DAT : stores the RFPI currently working
- PORT.DAT : stores the current established PORT number
BASESET
HANDSET
1.1.2
The files changing during the execution of program
Following files are newly create or changed during the execution of program.
- Information files containing each country°Øs PSTN OPTION (SWEDEN.DAT, FRANCE.DAT, GERMANY.DAT
- BASESET.DAT : Daily information of baseset serial numbers(RFPI)
written during manufacturing process
- HANDSET.DAT : Daily information of handset serial numbers(IPEI)
written during manufacturing process
1.2
Procedures of TEST PROGRAM execution
1.2.1
Program installation
Make a directory and copy files( explained at chaptor 1.1.1) neccessary for the execution of program. Execute JIGPCx.EXE to run the program after the completion of installation.
1.2.2
Program execution
1
. Select the PC's communication port(RS-
If the program is executed, "SELECT SERIAL PORT" will be displayed. Select PORT 1or PORT 2. If ENTER key is pressed without designating the PORT, it will automatically select the port previously used.
232
)
°¶
C port) connected to IIC CONVERTOR.
6
Samsung Electronics
2
. Select a set to be tested.
Select HANDSET or BASESET. In consequence of the selection made above, the menu on which you can choose if you revise EMC or execute test program is displayed. Select ‘MAIN MENU’ to execute the test.
Test Mode
3
. Connect the SP-R
To set the TEST MODE in HANDSET, power on by pressing OK button with holdin INT button down. When the TEST MODE setup is successfully completed, TEST menu will be displayed on HANDSET LCD. No response in 2seconds after sending ‘TEST MODE SETUP’ request to PC makes TEST MODE SETUP state end. HANDSET supports MANUAL TEST MODE by using its keypad. To set up MANUAL TEST MODE, press ¶Sbutton while checking 2-secondiong response. For the BASESET, power on by connecting power jack while holding PAGING button down. TEST MODE SETUP state is indicated by lighting PAGING LED on the BASESET. It waits the response from PC after sending ‘TEST MODE setup request’ to PC. There is no time limit unlike HANDSET. Once it’s in TEST MODE state, it consistantly waits the respose.
4
. Select Test Item
PC received the ‘TEST MODE setup request’ from a set sends back respose and displays TEST MAIN MENU on the screcn. Each test item proceeds referring to the contents on LCD. To finish TEST MODE, select “ from the TEST MODE MENU. If you force TEST MODE to end by turning the power off, the changes may not be stored.
5150
to be tested to IIC CONVERTOR and power it on.
0
)EXIT”
1.3
AUTO TEST MODE
1.3.1
CTR 6/ CTR 10TEST
To test CTR 6TEST MODE related to RF test, an equipment supporting CTR such as HP related to voice.
1
. Select “Z)TM” on MAIN TEST MENU.
2
. Select CTR 6or CTR 10. TEST MODE ends after setting up CTR 6or CTR 10.
1.3.2
ID Writing
ID writing is used to change the serial number of the HANDSET or BASESET. It’s called RFPI for BASESET, IPEI for HANDSET.
1
. Select “C)RFPI” or “C)RFPI on MAIN TEST MENU.
Previous and next IDs are displayed.
6
TEST
8923
is needed. CTR 10TEST MODE is used to test functions of the phone
7
Samsung Electronics