Following files should be installed for TEST PROGRAM execution
- JIGPCx.EXE: TEST execution program
- BASEEMC.DAT: stores the EMC code of Baseset
- HANDEMC.DAT: stores the EMC code of Handset
- BASEFLAG.DAT: stores the Flag information for requesting the new EMC code of
- HANDFLAG.DAT: stores the Flag information for requesting the new EMC code of
- IPEI.DAT: stores the IPEI currently working
- RFPI.DAT: stores the RFPI currently working
- PORT.DAT: stores the current established PORT number
BASESET
HANDSET
1.1.2
The files changing during the execution of program
Following files are newly create or changed during the execution of program.
- Information files containing each country°Øs PSTN OPTION
(SWEDEN.DAT, FRANCE.DAT, GERMANY.DAT
- BASESET.DAT: Daily information of baseset serial numbers(RFPI)
written during manufacturing process
- HANDSET.DAT: Daily information of handset serial numbers(IPEI)
written during manufacturing process
1.2
Procedures of TEST PROGRAM execution
1.2.1
Program installation
Make a directory and copy files( explained at chaptor 1.1.1) neccessary for the execution of
program. Execute JIGPCx.EXE to run the program after the completion of installation.
1.2.2
Program execution
1
. Select the PC's communication port(RS-
If the program is executed, "SELECT SERIAL PORT" will be displayed.
Select PORT 1or PORT 2. If ENTER key is pressed without designating the PORT,
it will automatically select the port previously used.
232
)
°¶
C port) connected to IIC CONVERTOR.
6
Samsung Electronics
Page 2
2
. Select a set to be tested.
Select HANDSET or BASESET.
In consequence of the selection made above, the menu on which you can choose
if you revise EMC or execute test program is displayed.
Select ‘MAIN MENU’ to execute the test.
Test Mode
3
. Connect the SP-R
To set the TEST MODE in HANDSET, power on by pressing OK button with holdin INT button down.
When the TEST MODE setup is successfully completed, TEST menu will be displayed on
HANDSET LCD.
No response in 2seconds after sending ‘TEST MODE SETUP’ request to PC makes TEST MODE
SETUP state end.
HANDSET supports MANUAL TEST MODE by using its keypad. To set up MANUAL TEST MODE,
press ¶Sbutton while checking 2-secondiong response.
For the BASESET, power on by connecting power jack while holding PAGING button down.
TEST MODE SETUP state is indicated by lighting PAGING LED on the BASESET.
It waits the response from PC after sending ‘TEST MODE setup request’ to PC.
There is no time limit unlike HANDSET. Once it’s in TEST MODE state, it consistantly waits the
respose.
4
. Select Test Item
PC received the ‘TEST MODE setup request’ from a set sends back respose and displays
TEST MAIN MENU on the screcn.
Each test item proceeds referring to the contents on LCD. To finish TEST MODE, select “
from the TEST MODE MENU. If you force TEST MODE to end by turning the power off, the changes
may not be stored.
5150
to be tested to IIC CONVERTOR and power it on.
0
)EXIT”
1.3
AUTO TEST MODE
1.3.1
CTR 6/ CTR 10TEST
To test CTR 6TEST MODE related to RF test, an equipment supporting CTR
such as HP
related to voice.
1
. Select “Z)TM” on MAIN TEST MENU.
2
. Select CTR 6or CTR 10. TEST MODE ends after setting up CTR 6or CTR 10.
1.3.2
ID Writing
ID writing is used to change the serial number of the HANDSET or BASESET.
It’s called RFPI for BASESET, IPEI for HANDSET.
1
. Select “C)RFPI” or “C)RFPI on MAIN TEST MENU.
Previous and next IDs are displayed.
6
TEST
8923
is needed. CTR 10TEST MODE is used to test functions of the phone
7
Samsung Electronics
Page 3
Test Mode
2
. Input ID
When you press any key, ID is written by adding 1. When press SHIFT-F10, written by
subtracting 1. Press SHIFT-F1to input ID directly, Esc to finish.
1.3.3
EEPROM DUMP
EEPROM DUMP is used to read the contents of the EEPROM of the BASESET or HANDSET.
It is also used to analize the causes for a inferior SET.
1
. Press ALT-F on MAIN TEST MENU.
2
. Input file name to save the dumped contents. If you input file name, PC gets
of from the EEPROM of the set and save it as the name you input.
It takes about 50seconds.
1.3.4
ERROR TREATING
“COMMUNICATION ERROR” is displayed when problem occurs while tranfering
data between the PC & SET.
When the message is seen, check the connection between PC & SET or state of the set.
When found no oddity try TEST MODE SETUP after getting rid of the power of the set.
512
byte size contents
1.4
MANUAL TEST MODE
1.4.1
MANUAL TEST MODE
MANUAL TEST is performed by using keypad on HANDSET.
It also works alone without separable PC & IIC CONVERTOR. Followings are suppoted in MANUAL
TEST MODE.
1
. CTR 6TEST
2
. CTR 10TEST
3
. SOFTWARE VERSION CHECK
4
. INITIALIZE SUBSCRIPTION
5
. WRITE EEPROM
6
.ESCAPE MANUAL TEST MODE
TEST MENU above performs with Up & Down scroll buttons. Searched TEST MENU is selected by
pressing OK button.
1.4.2
MANUAL TEST MODE SETUP
1
. To set up MANUAL TEST, press INT button then OK on HANDSET to turn the power on.
2
. Press ¶Swithin 2-second-long TEST SETUP period. If MANUAL TEST MODE is set up
correctly, “CTR 6” message (which is the first TEST MENU) appears on HANDSET LCD.
If MANUAL TEST MODE is not set up in 2seconds, MANUAL TEST MODE ends.
8
Samsung Electronics
Page 4
1.4.3
CTR 6TEST
To test CTR 6TEST MODE related to RF, an equipment supporting CTR 6TEST such as HP
needed.
1
.Press Up or Down button repeatedly until “TBR 6” apprears on HANDSET LCD.
Press OK.
CTB 6TEST MODE is set up.
1.4.4
CTR 10TEST
CTR 10TEST MODE is for testing functions of the phone related to voice such as Loudness test.
1
.Press Up or Down button repeatedly until “TBR 10” appears on HANDSET LCD.
Press OK.
2
.Input Loudness value of the HANDSET. The Loudness value ranges from
The loudness level “Hign / Mid / Low” for normal state corresponds to “
1.4.5
SOFTWARE VERSION CHECK
0
2/ 1/ 0
to 9.
”.
Verifying the date when the program made & its version.
1
.Press Up or Down button repeatedly until “Version” messgae appears on HANDSET LCD.
Press OK. The date and version appears.
Test Mode
8923
is
1.4.6
INITIALIZE SUBSCRIPTION
Being used to set up the HANDSET to initial state.
1
.Press Up or Down button repeatedly until “CLEAR SUB” message appears on HANDSET LCD.
Press OK. It initializes registered information in EEPROM for 10seconds. MANUAL TEST MODE ends.
1.4.7
WRITE EEPROM
Changing information Byte in EEPROM 1for the HANDSET. Changed Information will be saved when
MANUAL TEST MODE ends.
1
.Press Up or Down button repeatedly until “CHANGE DATA” appears on HANDSET LCD.
Press OK.
2
.Input new EEPROM address with the keypad in decimal system.
3
.Search the data you want to change with Up or Down button. Press OK button to input the data.
When change made, it goes back to the previous MENU. (“CHANGE DATA”)
1.4.8
ESCAPE MANUAL TEST MODE
Being used to escape from MANUAL TEST MODE. If information in EEPROM has changed while running
MANUAL TEST MODE. MANUAL TEST MODE ends after updating the information changed.
1
.Press Up or Down button repeatedly until “ESCAPE TEST” message appears on the HANDSET LCD.
Press OK.
It checks if the EEPROM information has changed, if so, update new INFORMATION in the eeprom.
It takes about 10seconds.
9
Samsung Electronics
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.