Heat Exchanger
Refrigerant Control Unit
Freezer Oil Capacitycc
Refrigerant to Change(R22)g
Protection Device(OLP)
Cooling Test Condition
Maximum Operation Condition
Type
Type
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Lengthm
CapacityA
Width x Height
x Depth
Liquidmm x L(m)
GASmm x L(m)
Rated Output
Rated OutputW
BTU/W
Model
3
/min
m
dB
W
A
%
mm
inch
SH05ZZ8SH07ZZ8
Indoor unitOutdoor unitIndoor unitOutdoor unit
Wall-mounted
5,000
5,000
0.9
4.319
4.519
3348
3348
10.2
10.8
1-220 / 240-50
490
460
2.3
2.2
92.6
90.9
17.0
-
-
250V-10 / 16A
728x255x155660x470x240
28.6x10.0x6.126.0x18.5x9.5
725.5
ø6.35 x 5
ø9.52 x 5
ø18 x 2,000
Rotary
--
--
Cross-flowPropeller
steelsteel
1120
2ROW 10STEP1ROW 20STEP
CAPILLARY TUBE
360
460
RAC12051-1208
INDOOR UNIT : DB27˚C WB19˚C OUTDOOR UNIT : DB35˚C WB24˚C
INDOOR UNIT : DB32˚C WB23˚C OUTDOOR UNIT : DB43˚C WB26˚C
728x255x155660x470x240
28.6x10.0x6.126.0x18.5x9.5
2ROW 10STEP1ROW 20STEP
Wall-mounted
7,000
7,500
1.0
5.219
5.419
3749
3749
10.5
11.6
1-220 / 240-50
680
650
3.0
2.8
98.5
100.9
17.0
-
-
250V-10 / 16A
725.5
ø6.35 x 5
ø9.52 x 5
ø18 x 2,000
Rotary
--
--
Cross-flowPropeller
steelsteel
1120
CAPILLARY TUBE
290
510
MRA99137-9201
1Samsung Electronics
1-2 Cooling Only
Item
Type
CoolingBTU/h
Dehumidifying|/h
Air VolumeCoolingm3/min
Perfor-
mance
NoiseCoolingdB
Energy Efficiency RatioCoolingBTU/W
Power V-Hz
Power ConsumptionCoolingW
Operating CurrentCoolingA
Power FactorCooling%
Power
Starting CurrentA
Lengthm
Power CordNumber of Core Wire
CapacityA
Outer Dimension
Weight(Net)kg
Refrigerant Pipe
Drain HoseD x L(mm)
Size
CompressorMotorType
BlowerMotorType
Heat Exchanger
Refrigerant Control Unit
Freezer Oil Capacitycc
Refrigerant to Change(R22)g
Protection Device(OLP)
Cooling Test Condition
Maximum Operation Condition
Type
Type
Width x Height
x Depth
Liquidmm x L(m)
GASmm x L(m)
Rated Output
Rated OutputW
Model
mm
inch
SC05ZZ8AS05Z1AZDAS07Z1AZD
Indoor unitIndoor unitIndoor unitOutdoor unitOutdoor unitOutdoor unit
Wall-mounted
5,000
0.9
4.319
3348
10
1-220 / 240-50
490
2.2
98.8
17.0
-
-
250V-10 / 16A
728x255x155 660x470x240
28.6x10.0x6.1 26.0 x 18.5 x 9.5
724.5
ø6.35 x 5
ø9.52 x 5
ø18 x 2,000
Rotary
--
--
Cross-flowPropeller
steelsteel
1120
2ROW 10STEP 1ROW 20STEP
CAPILLARY TUBE
360
440
RAC12051-1208
INDOOR UNIT : DB27˚C WB19˚C OUTDOOR UNIT : DB35˚C WB24˚C
INDOOR UNIT : DB32˚C WB23˚C OUTDOOR UNIT : DB43˚C WB26˚C
Wall-mounted
5,000
0.9
4.319
3348
11.3
1-200 / 220-50
440
2.2
90.9
16.5
-
-
250V-10 / 16A
728x255x155 660x470x240
28.6x10.0x6.1 26.0 x 18.5 x 9.5
724.5
ø6.35 x 5
ø9.52 x 5
ø18 x 2,000
Rotary
--
--
Cross-flowPropeller
steelsteel
1120
2ROW 10STEP 1ROW 20STEP
CAPILLARY TUBE
360
380
RAC12074-9622
728x255x155 660x470x240
28.6x10.0x6.1 26.0 x 18.5 x 9.5
2ROW 10STEP 1ROW 20STEP
Wall-mounted
7,000
1.0
5.219
3749
11.8
1-200 / 220-50
590
3
89.4
16.5
-
-
250V-10 / 16A
724.5
ø6.35 x 5
ø9.52 x 5
ø18 x 2,000
Rotary
--
--
Cross-flowPropeller
steelsteel
1120
CAPILLARY TUBE
360
400
RAC12074-9622
Samsung Electronics2
2. Disassembly and Reassembly
Stop operation of the air conditioner and remove the power cord before repairing the unit.
2-1 Indoor Unit
NoPartsProcedureRemark
1Front Grille
1) Stop the air conditioner operation and
block the main power.
2) Detach tape of Grille Air-Inlet.
3) After Both End Part of the Grille Lower
Position are pressing, it shall be detach by
pushing up.
4) Loosen 1 of the right screw and detach
the Terminal Cover.
5) Detach the thermistor from the Front
Grille.
6) Loosen 3 fixing screws of Front Panel.
3Samsung Electronics
Disassembly and Reassembly
NoPartsProcedureRemark
7) Pull the lower left and right of discharge
softly for the outside cover to be pulled out.
8) In order to disassemble the Panel Front
press, in order, the left, center and right of
the upper side of the Panel Grille with the
plam of the hand to remove the hook.
And then disassemble the Panel Grille.
2
3
Tray Drain
Electrical Parts
(Main PCB)
1) Pull Tray Drain out from the Back Body.
1) Take all the connector of PCB upper side
out. (Inclusion Power Cord)
2) Detach the outdoor unit connection wire
from the Terminal Block.
3) If pulling the main PCB up, it will be taken
out.
Samsung Electronics4
Disassembly and Reassembly
NoPartsProcedureRemark
4
Heat Exchanger
1) Loosen 2 fixing earth screws of right side.
2) Detach the Connection Pipe.
3) Detach the Holder Pipe at the rear side.
4) Loosen the 2 fixing screws of right and left
side.
5) Lifting the Heat Exchanger up a little to
push the up side for separation from the
indoor unit.
5
Fan Motor
&
Cross Fan
1) Loosen the 4 fixing screws and detach the
Motor Holder.
2) Loosen the fixing screw of Fan Motor.
(with a M3 wrench)
3) Detach the Fan Motor from the Fan.
4) Detach the Fan from the left Holder
Bearing.
5Samsung Electronics
Loading...
+ 14 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.