` Please make sure not to fully expose the camera to rain. The camera must be installed under a shelter to avoid exposure to excessive rain or
J
moisture.
AUDIO IN
AUDIO OUT
ALARM IN ALARM OUT
1 2 3 4 G 1 COM G
VGA
CONSOLE
NETWORK
USB
DC 12V
` The camera satisfies the IP65 standard, and direct exposure to water or moisture may cause problem such as condensation.
Ú If you do not use the Internet, just follow the steps below:
1245611121314151624
English-2
Page 3
2. INSTALLATION
1 2 3 4 G1 COMG
ALARM IN
ALARM OUT
NETWORK
USB
CONSOLE
VGA
AUDIO IN
AUDIO OUT
VIDEO OUT
DC 12V
Connect the camera to the Camera In port.
1
TO DVR SIDE ONLY
TO CAMERA SIDE ONLY
Connecting the Camera
` There are two labels affixed at the end of the jacks of camera
M
cable, indicating one of the jacks should be connected to DVR,
and the other should be connected to camera. Please check it
first before connection.
AUDIO OUT Connection
Connect the LAN cable and mouse.
3
The default connection for use of the Internet is as follows:
You can connect a USB HDD mouse to the USB port.
LANMouse
VIDEO OUT
AUDIO IN
AUDIO OUT
ALARM IN ALARM OUT
1 2 3 4 G 1COM G
VGA
NETWORK
CONSOLE
USB
DC 12V
Connect the Video and Audio Out connectors to the
2
monitor.
For a PC monitor, use the VGA connector for the
connection.
VIDEO OUT Connection
VGA OUT Connection
English-3
Local PC
Connect the modem to the
WAN port of the router and
connect each of the PC and
the set to the LAN port.
Connect the DC adaptor.
4
Broadband
Router or HUB
Broadband
Modem
Page 4
3. STARTING Up
2012-01-01 01:10:25
Connect the power source.
5
Ú If you don't change the “auto logout” item, please
7
refer
. The login prompt in 6 only appears when
you change the auto logout time.
When prompted, use the virtual keyboard to enter the
6
password (default: 4321) in the PASSWORD input box.
Login
ID admin
Password
OK Cancel
Ú All operations can be controlled with the mouse.
Using the Virtual Keyboard
6-1
1. Use the direction buttons ($%_+) to move to a desired
character and press the [ENTER] button.
2. Use the <
3. Use the <
> button to erase the previous character.
> button to toggle the letter case.
4. Complete your input and when done, click <OK> to close the
virtual keyboard.
Press the [MENU] button on the remote control.
7
Select <Date/Time/Language> in <System> menu.
8
Logout
Return
System
Date/Time/Language
Permission Management
System Management
Log Information
Use the mouse to adjust the time setting.
9
Date/Time/Language
Date/Time/Language
Date 2012-01-01 YYYY-MM-DD
Time 08:14:24 24 Hours
Time Zone GMT
Time Sync. Setup
DST Dec First (Sun) 0 Dec First (Sun) 0
Language English
Holiday
OK Cancel
Ú To apply your setting click the <OK> button.
Select the Network menu. Sets the Connection type to
10
<Static IP> and enter the IP address. Click the <OK>
button.
Connection Mode
Connection
Protocol
Connection Mode Static IP
Bandwidth 2Mbps
IP 192.168. 1.200
Gateway 192.168. 1. 1
Subnet Mask 255.255.255. 0
DNS Manual168.126. 63. 1
` 1 2 3 4 5 6 7 8 9 0 - =
q w e r t y u i o p [ ] \
a s d f g h j k l ; ‘
z x c v b n m , . /
Space Ctrl
OK Cancel
Caps Lock
Shift
Del
Ú If using DI-624 manufactured by D-link
IP ADDRESS:192.168.1.200/
GATEWAY: 192.168.1.1 / SUBNET MASK: 255.255.255.0 /
ST
1
DNS SERVER: 168.126.63.1 / 2ND DNS SERVER:
168.126.63.2
OK Cancel
English-4
Page 5
4. REC & pLAY
2012-01-01 01:10:25
Press the [MENU] button on the remote control.
11
Select <Record>.
Set each of the Record Schedule options.
12
To change the setting, set the channel then select the
time and date you when want to record.
Press the [ENTER] button while the cells are selected.
The record type will cycle through <No Recording><Continuous>-<Event>-<Both(Cont&Evnt)>.
The default is as shown below.
Logout
Return
Record
Recording Schedule
Event Record Duration
REC Quality & Resolution
Record Option
To change the record quality & resolution, select
13
<REC Quality & Resolution>.
If you change the setting of the resolution and the remaining
rate, the remaining count shows each available resolution.
Select a desired date in the calendar, and a desired
15-1
timeline in the Time bar, and press the <Play> button.
Time Search
2012-01-01
2012/01/01 00:01:17
Standard Schedule
Motion Etc
V.Loss
Go to FirstGo to Last
Overlapped Data List1
00:01
All Data
CAM 01
CAM 02
CAM 03
CAM 04
Play Return
Zoom In Zoom Out
The colored line indicates types of the recording data.
If you want to play a time specific data, enter an exact
time.
If you have set the event recording, you can play a
15-2
desired scene using the <Event Search> function. Set
a desired date in the calendar and the result will be
listed on the table.
Select one you desired and press the <Play> button.
Event Search
CAM 01
2012-01-01
Overlapped Data List1
2012/01/01 00:01:22
No. Date/Time Preview Event
3 02:47:54 ~ 02:48:59 Motion
2 00:39:06 ~ 00:40:30 Motion
1 00:01:22 ~ 00:02:28 Motion
Play Return
Go to FirstGo to Last
Previous/Next Page
OK Cancel
SYSTEMRECORD SIZEPOSSIBLE FPS
CIF 352 × 240OFF, 1~30
NTSC
2CIF 704 × 240OFF, 1~30
4CIF 704 × 480OFF, 1~30
CIF 352 x 288OFF, 1~25
PAL
Press the [SEARCH] button on the remote control.
14
2CIF 704 x 288OFF, 1~25
4CIF 704 x 576OFF, 1~25
16
English-5
You can change the play speed or channel, or stop the
playback using the onscreen button bar.
REC
Page 6
5. ROUTER & pORT FORWARDING SET Up
The following is configuration for the Internet connection.
17
This is a typical example.
Cable/ADSL Modem
Internet
DDNS Server
(websamsung.net)
In the Network Properties window, check the IP address
18
and gateway.
Connect to the router using the gateway address found
19
in step ‘
Local PC
18
or
Direct LAN
(Fixed/Static IP)
’ above.
Broadband
Router or HUB
POWER
REC
DVR
192.168.1.200
255.255.255.0
192.168.1.1
DIGITAL VIDEO RECORDER
Port Forwarding
21-1
When the router setting is done, select Virtual Server in
the “Advanced” tab where you can configure the Port
Forwarding settings. Click “Apply” to apply your
settings.
For more information, refer to the router guide of the manual CD.
`
(Model: D-LINK DI-624).
IP : 192.168.1.200
Protocol : TCP
Private Port : 4520~4524
Public Port : 4520~4524
Running the Quick Connect program
21-2
For more information, refer to the quick connect guide of the
`
provided manual CD.
IP : 192.168.1.200
Protocol : TCP
Private Port : 80
Public Port : 80
It is easy for you to use DHCP setting for Quick Connection Program.
Path: Network Connection Mode Connection
Change: Static IP Dynamic IP
1. Insert the provided CD into your computer’s CD drive, and
double click “Quick Connect.exe” program to run it.
2. Click [Next >] button.
3. When <
> appears on the right side of TCP Port and Web
port number, click [Next >] button.
4. Click [Finish] button to exit the program.
If you first connect to the router, you will see the “Setup Wizard” run that proceeds in the following order.
20
English-6
Page 7
6. WEb bROWSING
In the address bar of Internet Explorer, enter the Set IP.
22
For the internal network, enter the Set Local IP and for the
external network, enter the DDNS address.
* Refer to the domain name of the set defined in DDNS
Menu.
If the popup window is not activated, unblock the popup.
If you first connect to the PC, you will see
a message as shown.
Install the suggested ActiveX control.
If you first connect to the PC, you will see a message as
shown above. Click “Install” to install the suggested
software.
Connection Mode
Connection
Protocol
Connection Mode Static IP
Bandwidth 2Mbps
IP 192.168. 1.200
Gateway 192.168. 1. 1
Subnet Mask 255.255.255. 0
DNS Manual168.126. 63. 1
If you select <iPOLiS>, the “DDNS host address” item will be
`
displayed. iPOLiS users should register the device with the website
(Domestic (Korea): http://www.samsungipolis.co.kr, Overseas:
http://www.samsungipolis.com) and provide the user name.
(ex: Registered as SDE-300X_HOME)
Connect to the Web Viewer and enter the user ID and
23
password.
Default ID: admin, PW: 4321
For more information, refer to the user manual. (Page 66)
`
The default password can be exposed to a hacking thread so it is
`
recommended to change the password after installing the product.
Note that the security and other related issues caused by the
unchanged password shall be responsible for the user.
OK Cancel
EX. LAN http://192.168.1.200:80
(when you connect the set within Local
Network or know that IP)
WAN http://www.samsungipolis.com/User ID
(When you connect the set via External Network)
English-7
Page 8
7. MONITORING
2012-01-01
01:10:25
2012-01-01 01:10:25
Right click the screen or press the [MODE] on the
24-1
remote control.
When the launcher menu appears, press the < >
24-2
button.
Ú You can add or modify the screen transition interval
in “System > Device > Monitor” menu.
If the DVR set is connected to the Internet in normal
25
network settings, you can set the DVR’s current time in
sync with the selected <Time Server> regularly if you
select to use <Time Server>.
If you want to use the DST functions, set it to ON.
Date/Time/Language
Date/Time/Language
Date2012 -01-01 YYYY-MM-DD
Time Synchronization Setup
Synchronization Use
Time08:14:24 24 Hours
Time Server 203.248.240.103
Time Zone GMT+08:00
Last Sync Time Fail
Time Sync.SetupNot Used
Activate as Server Use
DSTDec First (Sun) 0H Dec First (Sun) 0H
Language English
Holiday
OK Cancel
OK Cancel
Using a Smartphone
26
1. Download iPOLiS mobile to your Smartphone.
2. From the start screen of iPOLiS mobile, tap <Device List>.
The Add Device screen appears.
3. Register the DVR to the iPOLiS mobile.
` For more information, refer to the user manual.
M
(http://www.samsungcctv.com)
1.X
English-8
Loading...