This manual is proprietary to SAMSUNG Electronics Co., Ltd. and is protected by copyright.
No information contained herein may be copied, translated, transcribed or duplicated for any commercial
purposes or disclosed to the third party in any form without the prior written consent of SAMSUNG Electronics
Co., Ltd.
TRADEMARKS
Product names mentioned in this manual may be trademarks and/or registered trademarks of their respective
companies.
This manual should be read and used as a guideline for properly installing and operating the product.
This manual may be changed for the syst em improvement, standardization and other technical reasons without pri or
notice.
If you need updated manuals or have any questi ons concerning the contents of the manuals, contact our Document
This annex describes the standard torque when assembling the fixing materials.
ABBREVIATION
Describes the acronyms used in this manual.
Conventions
The following types of paragraphs contain special information that must be carefully read
and thoroughly understood. Such information may or may not be enclosed in a rectangular
box, separating it from the main text, but is always preceded by an icon and/or a bold title.
WARNINGProvides information or instructions that the reader should follow in order to avoid
personal injury or fatality.
CAUTIONProvides information or instructions that the reader should follow in order to avoid
a service failure or damage to the system.
CHECKPOINT
Provides the operator with checkpoints for stable system operation.
The purpose of the Safety Concerns section is to ensure the safety of users and prevent
property damage. Please read this document carefully for proper use.
Symbols
Caution
Indication of a general caution
Smart MBS RRH-P4 Installation Manual
Restriction
Indication for prohibiting an action for a product
InstructionIndication for commanding a specifically required action
Caution for cleaning the Power Supply While cleaning the power supply device, take caution that the device does not
come in contact with alien bodies that may cause power failure.
Caution for installing the power cable To maintain cable gland’s rain protection performance, 11.81 in. (300 mm) or
more interval should be kept straight. According to the radius of curvature of the
cable specification should be consider e d.
Caution for cutting the power cable
Cut power cable after installing power cable to RRH-P4 power terminal taking into
account the radius of curvature according to the cable specifications.
When cutting the cable first, the length difference of cable end can be occurred by
cable curvature and the power terminal may cau se contact fault.
Caution When Connecting Optical Cables Before connecting an optical cable, make sure that there i s no dust or foreign
substance on the cross-section of the connect or core. If t here i s any dust or for eign
substance, do not remove it by blowing with your mouth. Remov e the dust or
foreign substance by referring to the method of cleaning optic connector.
Caution on Rain-proof Gasket Damage When Installing Window Cover Be careful so as not to let the rain-proof gasket get damaged (broken or
incorrectly positioned). Check whether the rain-proof gasket is damaged before
closing the power window cover and the optic window cover.
If the rain-proof gasket is damaged, replace the s ystem (RRH-P4) with a new
Radius of Curvature of Feeder Line When installing a feeder line, the radius of curvature of the sections where cables
Connection of Feeder Cable Connector Connecting the feeder cable connector is critical process, so the qualified workers
Caution When Connecting RET Cable
Make sure to turn off the breaker connected to the RRH-P4 power of the DU
If you connect or disconnect the RET cable while the breaker is turned on, it may
bent should be larger than the allowed r adius of cur v ature. If the radius of c ur v ature
for the feeder line installation is less than the allowed radius of curvature, it may
affect the performance of the system.
who finished the related education should perform.
cabinet before connecti ng the RET cable between the antenna RET port and the
RRH-P4 RET port.
cause an electric short circuit resulting in damage to the RET function.
Installation General
Caution when losing External Power Cable Support Bracket (‘2.6 Connecting
ground cable’)
External Power Cable Support Bracket and two cable tie (stai nles s steel) for fix ing
cable are enclosed in RRH-P4 package. Be careful not to lose when unpacking
package.
Managing unused port Finish unused port of UADU by dust-cap, not making the alien substance flowed.
Finishing Cable Insertion Hole Finishing work is required on cable insertion holes (Cable gland, Conduit and
etc.) to prevent entering of any foreign substance, external air and moisture.
- Unused cable insertion hole: Finish cable insertion hole using fishing materials
such as dust cap, rubber packing and etc.
- Cable-installed insert ion hole: After installing cable, finish inse rtion hole usi ng tape,
compressed sponge, rubber packing, silicon, etc. to prevent empty sp ace.
Caution when assembling the cable gland Ensure that all parts of the cable gland are assembled in the correct sequence.
Incorrect assembly may result in influx of external air or moisture into the system
and may cause corrosion, system malfunction and/or critical failure of the cooling
system.
Caution when installing the cable in the cable glandOnly one cable of permitted specification (radius) should be installed in the cable
gland.
- Installing a cable of smaller radius than the permitted specification may result in
influx of external air or moisture into the system and may cause corrosion or
system malfunction.
- Installing a cable thicker than the permitted specification or installing two or
more cables in the gland may damage the gland.
Caution when loosen and tighten the Cable Gland Nut In case of assembling the c able gland and cabling, do not loosen and tighten by
turning the cable gland body or other parts. turning the cable gland body may
cause corrosion and system failure by entering of any external air and moisture.
Checking assembly state of the unused cable glandAll components of the unused cable gland must be secured in the original factory
configuration. If the cable gland nut is fitted without the rain protection filler or the
protection cover in place, reassemble them as illustrated in ‘Figure 2.7.’
Do not work by yourselfDo not work by yourself in any key process.
Caution for cleaning the Rack Make sure that worker does not damage installed cables while cleaning the rack.
Cautions When Connecting the CRPI Cable Failure to observe the CPRI cable connection specified in Table 2.5 may impair
the communication between the CDMA and LTE FDD terminal.
RRH-P4 optic cable connection standard Cable connection standard between UADU CPRI port and RRH-P4 optic port is
Connect the optic cable (Refer to the connection standard of ‘table 2.6’ and ‘table
Caution when Installing the RF antenna To protect from lightning, the RF antenna must be installed within the shielding
- The protection angle of the lightning rod should be 45 degrees.
different according to the count (One or two) of CDMA UADU (Installed in DU
cabinet).
2.7’). Because false connection can cause t he fault of call c onnection, be cautious.
angle as shown below, considering the downward distance and the angle from
the tower lightning rod or the antenna pole lightning rod.
Finishing Heat Shrink Tube of a Sector Antenna
1) Insert an antenna protection plate.
2) Place the heat shrink tube on the connection point and shrink the heat shrink
tube using a heat gun.
3) Avoid aiming the heating gun toward the antenna’s body.
California USA Only
This Perchlorate warning applies only to primary CR (Manganese Dioxide)
Lithium coin cells in the product sold or distributed ONLY in California USA
‘Perchlorate Material-special handling may apply, See
www.dtsc.ca.gov/hazardouswaste/perchlorate.’