Samsung RF4287HAWP-XAA, RF4287HARS-XAA, RF4287HABP-XAA, RF4287HAPN-XAA User Manual

Fast Track Troubleshooting
Model: RF4287HARS/XAA RF4287HAPN/XAA RF4287HABP/XAA RF4287HAWP/XAA
Bulletins:
Sales Mode: No Heating or Cooling. No compressor Operation. Press Energy Saver and the Power Freeze buttons simultaneously for 3 seconds ( You will hear a Ding Dong ) to remove or put into sales mode. When in the sales mode, the display will show ‘’OF” “OF” Removing power will not cancel this mode.
IMPORTANT SAFETY NOTICE“For Technicians Only” This service data sheet
Publication # Dr RF4287HARS Revision Date 9/17/13
Support Information:
HELP: 1-888-751-4086 ( Tech Sup. – ASC/SSD) 1-866-894-0637 (Tech Sup. - FE/ME) GSPN: http://service.samsungportal.com/EP/web/portal/jsp/EP_Default1.jsp PLUS ONE: http://my.plus1solutions.net/clientPortals/samsung
Force Mode:
Press the Energy Saver and Power Cool buttons simultaneously for 8­12 Seconds, until the display beeps and goes blank (Note: there will be no sound when both buttons are pressed at the same time)
Wait 5 Seconds between button pushes
Self Diagnosis: Press Energy Saver and lighting buttons simultaneously for 8­12 seconds, until the display quits blinking and beeps, then release the buttons and read Fault codes. ( Note: there will be no sound when both buttons are pressed at the same time ) This will also cancel the fault code being displayed at start up if any.
( Refer to page 3 for Error code diagnosis )
Press the power freeze button one time at the forced mode to force compressor on High Speed Run. Measure fan & compressor voltage at main PCB.
Press the power freeze button a second time to force mid speed run.
Press power freeze a 5th time until blank screen wait 30secs to exit
Press the power freeze button a third time to force low speed run.
Press the power freeze button a fourth time to Force Defrost of the Fridge & Freezer. Measure defrost voltage at main PCB.
LOAD MODE
HOW TO ENTER
Step 1. Hold the top two buttons together until the display blinks.
Step 2. while the display is blinking let go of the top two buttons. After doing so tap on the Fridge button.. Load Mode will start
Main PCB -
Version 00
Wire Diagram Version 00
Wire Diagram Version 01
Wire Diagram Version 01
WHT
The Time Divided Multi-cycle (TDM) system ( Stepper Valve) is used to switch refrigerant flow. This improves temperature control and energy efficiency. If its on the all evaporator mode it should work properly, Using slightly more energy. If its on the freezer evaporator only mode, there will be a Fridge no cool force on the fridge with the Power Cool option. Monitor the fridge evaporator (s) temp by using the Defrost Sensor(s). If the temp doesn’t decrease, then suspect the Main PCB is not supplying signal to switch the diverter valve.
POWER(110V)
Loading...