PN60E8000GFXZA

Vs Va Vsc Ve Label Voltages
Fast Track Troubleshooting Manual – Rev 5/23/12
5/ 15/12 ASC20120515001 Capturing emergency Log Info -Download for SEA Info 4/2/12 ASC20120402001 : Voice Command issue … Fix: Update to latest firmware
Quick Parts: Verify before Ordering
SERVICE BULLETINS
HELP : 888-751-4086; 866-894-0637 FE)
GSPN
http://gspn3.samsungcsportal.com
PLUS ONE
http://my.plus1solutions.net/clientPortals/samsung
HOT TIPS
- Check for continuous Firmware upgrade for this model series…
-Motion Control command problems are related to Firmware upgrade and room environments. Check room environment and user operation understanding and conditions.
FIRMWARE
2012 PDP Echo-P Firmware (1018.2) 5/25/12
Avail on GSPN or Samsung,Com
1
Fast Track Troubleshooting Manual PN60E8000GFXZA
1. 5V STBY SMPS to Main
2. PS_ON Main to SMPS (all Low Voltages on)
3. PS_ON SMPS thru X-Board to Logic Board
4. VS_ON Logic Board thru X-Board to SMPS
(VS & VA voltages turned on)
CN 4005 X-Board
8 DGND
9 VS_ON
10 VS_CON
11 PS_ON
12 DGND
13 NC
Signal
Fast Track Troubleshooting Manual
Power Supply Trouble Shooting Notes:
2010/2011/2012 models
Will not be run with the “X” or “Y” main disconnected. The SMPS will shut down immediately. However if a meter is first connected to the test point when power is applied it will read the correct voltage briefly before shut- ting down.(You have enough time to check key voltages)
CAUTION: Do not reconnect any connectors to SMPS or Y/X Boards until
power has been turned off long enough for Vs to drop below 10V or damage will occur to X or Y Boards. .
Over Current Protection
For the SMPS Power Supply... If a short circuit occurs on either the VS or VA voltage lines, the SMPS stops operating, but should not fail. When the short circuit is removed from the source line, the Power Supply will operate normally again. Many SMPS Supplies are replaced needlessly!
SAMPLE VIEW & READINGS
. VITAL SIGNS check Vs, Va, Vsc & Ve
When troubleshooting, It’s very important to first check Vs, Va, Vsc & Ve If Vs is missing (0V), disconnect power and check for short. Use ohm meter to measure resistance while disconnecting Y-Board & X-Board supply feeds one at a time. Turn Power On and Test SMPS with short connector removed for correct Vs voltage verification. (It may only come up briefly but to full level). Again be careful not to reconnect Power Connectors until Vs falls below 10V.
If Va is low or missing, disconnect Supply Feed to Address Boards and Check to see if SMPS Supply is restored. (Note Va feed normally passes through the Y-Drive to the Address Boards (Logic Buffer Boards).
If Vsc is low or missing and Vs was OK, the failure is with the Y-Board
.
since the Y-Board generate the Vsc voltage from the Vs supplied by the SMPS. If Ve is low or missing and Vs is OK, the failure is with the X-Board since the Ve is generated by the X-Board from the Vs supplied by the SMPS. Please note in some rare cases the Ve may be generated by the Y-Board feed to the X­Board.) Other SMPS Voltages: Check Low Voltage feeds to the Main Board and other supplied Assemblies.