Samsung MWR-WE10N Product information

 

 

 

SUBMITTAL

MWR-WE10N

 

Page 1 of 2

 

 

 

 

 

 

 

 

 

Samsung Premium Wired Indoor Unit Controller

Job Name

 

Location

 

 

 

Purchaser

 

Engineer

 

 

 

Submitted to

Reference

 

Approval

Construction

 

 

 

 

 

 

 

 

 

 

 

 

Unit Designation

 

Schedule #

 

 

 

Features*

Easy indoor unit control

Air handler operation ON/OFF

Air handler operation mode, set temperature, air flow direction, fan speed

Discharge air temperature setting (with supported indoor unit models)

Quiet and sleep modes

Error display

Filter replacement alarm display and reset

Single indoor unit control or multiple unit control (maximum 16 units)

Energy saving operation

Upper/lower temperature setting

Automatic operation stop function to turn off connected unit(s) if controller is not touched for specified amount of time (1 - 12 hours).

Energy saving operation mode

Weekly operating schedule setting

Weekly operating schedule

Able to set desired A/C operation mode, setting temperature and fan speed to operate based on weekly schedules

Able to apply schedule exception day

Other features

Different button permission levels

Partial button lock option (on/off, selection, temperature setting, fan speed, and schedule setting buttons can be locked individually)

Backlight

Daylight savings clock advance option

Temperature limit setting option

Real-time clock function; current time/day display function

Built-in room sensor

Display set temperature or room temperature

Indoor unit operation state display

Service mode support (indoor unit cycle data monitoring, option code monitoring and setting, and dip switch state monitoring)

Independent louver control for DVM S Series 4-way cassette models (AM0**FN4DCH)

Adjustable heating temperature compensation values

Child lock

*Some features may not be available depending on the model of connected air handler(s)

Specifications

Compatible with Samsung DVM S Systems (AM****X*A**/AA,

AM0***XMDCH/AA) and CAC systems (AC0**JN*DCH/AA)

Can connect and control up to 16 indoor units on a single system or across multiple systems

2 Conductor connection

DC 12V power supplied by indoor unit

PLC (power line communication) is done on F3/F4 terminals.

Can sense temperature via internal sensor, temperature sensor inside indoor unit, or use the average temperature between controller and air handler temperature sensors

MWR-WE10N has screw terminals for all wiring connections, wire is not included

16 AWG shielded cable is necessary for proper operation

4 3/4"

3/4"

 

<![if ! IE]>

<![endif]>4 7/8"

<![if ! IE]>

<![endif]>2 1/2

(Pictured with door open)

Samsung and Quietside maintains a policy of ongoing development,specifications are subject to change without notice.

QS-DVMS-082015A

www.SamsungDVM-S.com 888-699-6067

Samsung MWR-WE10N Product information

SUBMITTAL MWR-WE10N

Page 2 of 2

 

Samsung Premium Wired Indoor Unit Controller

 

Common Controller Configurations/Options

 

Individual control - 1 indoor unit with 1 wired control

F1/F2 (main system communication)

DVM S

F3/F4

F3/F4

F3/F4

F3/F4

F3/F4

Outdoor Unit

Wired Controller

Group control - up to 16 indoor units on 1 wired controller

F1/F2 (main system communication)

DVM S

 

 

 

Outdoor Unit

F3/F4

 

F3/F4

 

 

 

F3/F4

F3/F4

F3/F4

 

Wired Controller

 

Wired Controller

Group control - up to 16 indoor units on 1 wired controller on multiple refrigerant systems

F1/F2 (main system communication)

F1/F2 (main system communication)

DVM S

Outdoor Unit

F3/F4 F3/F4 F3/F4

Wired Controller

DVM S

Outdoor Unit

 

Group control - control 1 or multiple indoor units with 2 wired controllers

F1/F2 (main system communication)

DVM S

F3/F4

F3/F4

F3/F4

F3/F4

Outdoor Unit

 

F3/F4

 

 

F3/F4

Wired Controller

 

Wired Controller

Wired Controller

Group control - up to 16 indoor units on multiple refrigerant systems with 2 wired controllers

F1/F2 (main system communication)

F1/F2 (main system communication)

DVM S

 

F3/F4

F3/F4

 

Outdoor Unit

F3/F4

 

F3/F4

 

 

 

 

 

 

 

DVM S

Outdoor Unit

Wired Controller

Samsung and Quietside maintains a policy of ongoing development,specifications are subject to change without notice.

The diagrams on this page are for reference only. Refer to installation manual for wiring and installation instructions. Other configurations may be possible.

www.SamsungDVM-S.com