Samsung MTP02P 41A Users Manual

Radio Access Network
Installation Manual
Describes product installation and requirement procedure.
Document Version 1.0
April 2018
Document Number: 2600-00M896GAA
© 2018 SAMSUNG Electronics Co., Ltd. All Rights Reserved. The contents of this document/presentation contain proprietary information that
must be kept confidential. No part of this document shall be photocopied, reproduced, stored in a retrieval system, or transmitted, in any form or by any means whether, electronic, mechanical, or otherwise without the prior written permission of SAMSUNG Electronics Co., Ltd.
No warranty of accuracy is given concerning the contents of the information contained in this publication. To the extent permitted by law no liability (including liability to any person by reason of negligence) will be accepted by SAMSUNG Electronics Co., Ltd., its subsidiaries or employees for any direct or indirect loss or damage caused by omissions from or inaccuracies in this document. SAMSUNG Electronics Co., Ltd. reserves the right to change details in this publication without notice.
SNMTC-v3-0312
This manual should be read and used as a guideline for properly installing and/or operating the product. Owing to product variations across the range, any illustrations and photographs used in this manual may not be a wholly accurate depiction of the actual products you are using. This manual may be changed for system improvement, standardization and other technical reasons without prior notice. Samsung Networks documentation is available at http://www.samsungdocs.com
Confidential
MTP02P Series Installation Manual v1.0 iii Copyright © 2018, All Rights Reserved.
Contents
Preface viii
Conventions in this Document ....................................................................................................... viii
Revision History ............................................................................................................................... ix
Organization of This Document ...................................................................................................... ix
Related Documentation .................................................................................................................. ix
Personal and Product Safety ............................................................................................................ x
Equipment Markings ...................................................................................................................... xiv
Chapter 1 Before Installation 1
System Configuration and Interface ................................................................................................ 1
MMU Configuration ..................................................................................................................... 1
MMU Interface ............................................................................................................................ 2
Specifications ................................................................................................................................... 3
Cautions for Installation ................................................................................................................... 4
Before Installing ........................................................................................................................... 4
While Installing ............................................................................................................................ 4
After Installing ............................................................................................................................. 5
Installation Tools .............................................................................................................................. 6
Chapter 2 Installing System 9
Installation Procedure ...................................................................................................................... 9
System Arrangement ..................................................................................................................... 10
Unpacking and Transporting .......................................................................................................... 14
Bringing in Items ........................................................................................................................ 14
Unpacking Items ........................................................................................................................ 14
Handling the System ...................................................................................................................... 15
Transporting the MMU .............................................................................................................. 15
Fixing System .................................................................................................................................. 16
Fixing Pole Type_Down Tilting Installation ................................................................................ 16
Fixing Pole Type_Up Tilting Installation ..................................................................................... 30
Fixing Wall Type ......................................................................................................................... 44
Tilting System ................................................................................................................................. 59
Chapter 3 Connecting Cables 66
Cabling Procedure .......................................................................................................................... 66
Guidelines for Cable Connections .................................................................................................. 67
Cable Path Inspection ................................................................................................................ 67
Cable Cutting ............................................................................................................................. 68
Cable Installation ....................................................................................................................... 68
Cable Binding ............................................................................................................................. 69
Connector Attachment............................................................................................................... 69
Identification Tag Attachment ................................................................................................... 70
Cabling Diagram ............................................................................................................................. 71
Grounding ...................................................................................................................................... 72
Connecting Ground Cable .......................................................................................................... 72
Power Cabling ................................................................................................................................ 76
Connecting Power Cable ............................................................................................................ 77
External Interface Connection ....................................................................................................... 80
Confidential
Contents
MTP02P Series Installation Manual v1.0 iv Copyright © 2018, All Rights Reserved.
Connecting LINK Cable ............................................................................................................... 80
Chapter 4 Inspect the Installation 84
Appendix A Acronyms 88
Appendix B Clean the Optical Connectors 89
Introduction ................................................................................................................................... 89
Measure the Optical Output and Connecting the Optical Connector ........................................ 89
Appendix C Standard Torque 91
Confidential
MTP02P Series Installation Manual v1.0 v Copyright © 2018, All Rights Reserved.
List of Figures
MMU Configuration ......................................................................................................................... 1
MMU Interface ................................................................................................................................. 2
Procedure to Install the MMU ......................................................................................................... 9
MMU Arrangement_Pole Type ...................................................................................................... 10
MMU Arrangement_Pole Type_Up/Down Tilting .......................................................................... 11
MMU Arrangement_Wall Type ...................................................................................................... 12
MMU Arrangement_Wall Type_Up/Down Tilting ......................................................................... 13
Transporting the MMU .................................................................................................................. 15
Assembling Fixed Bracket Assembly_Down Tilting Installation (1) ................................................ 16
Assembling Fixed Bracket Assembly_Down Tilting Installation (2) ................................................ 17
Assembling Fixed Bracket Assembly_Down Tilting Installation (3) ................................................ 17
Assembling Fixed Bracket Assembly_Down Tilting Installation (4) ................................................ 17
Assembling Fixed Bracket Assembly_Down Tilting Installation (5) ................................................ 18
Assembling Scissors Bracket Assembly_Down Tilting Installation (1) ............................................ 19
Assembling Scissors Bracket Assembly_Down Tilting Installation (2) ............................................ 20
Assembling Scissors Bracket Assembly_Down Tilting Installation (3) ............................................ 20
Assembling Scissors Bracket Assembly_Down Tilting Installation (4) ............................................ 21
Assembling Scissors Bracket Assembly_Down Tilting Installation (5) ............................................ 22
Fixing Scissors Bracket Assembly_Down Tilting Installation .......................................................... 23
Fixing Fixed Bracket Assembly_Down Tilting Installation .............................................................. 24
Lifting the MMU (1) ........................................................................................................................ 25
Lifting the MMU (2) ........................................................................................................................ 26
Fixing MMU on the Pole_Down Tilting Installation (1) .................................................................. 27
Fixing MMU on the Pole_Down Tilting Installation (2) .................................................................. 28
Leveling MMU on the Pole_Down Tilting Installation .................................................................... 29
Plate Adjustment ............................................................................................................................ 29
Assembling Fixed Bracket Assembly_Up Tilting Installation (1) ..................................................... 30
Assembling Fixed Bracket Assembly_Up Tilting Installation (2) ..................................................... 31
Assembling Fixed Bracket Assembly_Up Tilting Installation (3) ..................................................... 31
Assembling Fixed Bracket Assembly_Up Tilting Installation (4) ..................................................... 31
Assembling Fixed Bracket Assembly_Up Tilting Installation (5) ..................................................... 32
Assembling Scissors Bracket Assembly_Up Tilting Installation (1) ................................................. 33
Assembling Scissors Bracket Assembly_Up Tilting Installation (2) ................................................. 34
Assembling Scissors Bracket Assembly_Up Tilting Installation (3) ................................................. 34
Assembling Scissors Bracket Assembly_Up Tilting Installation (4) ................................................. 35
Assembling Scissors Bracket Assembly_Up Tilting Installation (5) ................................................. 36
Fixing Fixed Bracket Assembly to the MMU................................................................................... 37
Fixing Scissors Bracket Assembly to the MMU............................................................................... 38
Lifting the MMU (1) ........................................................................................................................ 39
Lifting the MMU (2) ........................................................................................................................ 40
Fixing MMU on the Pole_Up Tilting Installation (1) ....................................................................... 41
Fixing MMU on the Pole_Up Tilting Installation (2) ....................................................................... 42
Leveling MMU on the Pole_Up Tilting Installation ........................................................................ 43
Plate Adjustment ............................................................................................................................ 43
MMU Marking Dimensions ............................................................................................................ 45
Marking_Wall Type ........................................................................................................................ 46
Drilling & Anchoring (1) .................................................................................................................. 47
Confidential
List of Figures
MTP02P Series Installation Manual v1.0 vi Copyright © 2018, All Rights Reserved.
Drilling & Anchoring (2) .................................................................................................................. 48
Assembling Fixed Bracket Assembly_Wall Type (1) ....................................................................... 49
Assembling Fixed Bracket Assembly_Wall Type (2) ....................................................................... 50
Assembling Scissors Bracket Assembly_Wall Type (1) ................................................................... 51
Assembling Scissors Bracket Assembly_Wall Type (2) ................................................................... 51
Assembling Scissors Bracket Assembly_Wall Type (3) ................................................................... 52
Assembling Scissors Bracket Assembly_Wall Type (4) ................................................................... 52
Assembling Scissors Bracket Assembly_Wall Type (5) ................................................................... 53
Fixing Scissors Bracket Assembly_Wall Type ................................................................................. 55
Fixing Fixed Bracket Assembly_Wall Type ..................................................................................... 56
Fixing MMU on the Wall (1) ........................................................................................................... 57
Fixing MMU on the Wall (2) ........................................................................................................... 58
MMU Down Tilting (1) .................................................................................................................... 60
MMU Down Tilting (2) .................................................................................................................... 61
MMU Down Tilting (3) .................................................................................................................... 62
MMU Up Tilting (1) ........................................................................................................................ 63
MMU Up Tilting (2) ........................................................................................................................ 64
MMU Up Tilting (3) ........................................................................................................................ 65
Procedure to Connect MMU Cables............................................................................................... 66
Cable Connection Procedure.......................................................................................................... 67
Cable Diagram ................................................................................................................................ 71
Connecting Ground Cable (1) ......................................................................................................... 73
Connecting Ground Cable (2) ......................................................................................................... 74
Connecting Ground Cable (3) ......................................................................................................... 75
Power Equipment Elements ........................................................................................................... 76
Connecting Power Cable (1) ........................................................................................................... 78
Connecting Power Cable (2) ........................................................................................................... 78
Connecting Power Cable (3) ........................................................................................................... 79
Connecting LINK Cable (1) .............................................................................................................. 80
Connecting LINK Cable (2) .............................................................................................................. 81
Connecting LINK Cable (3) .............................................................................................................. 82
Installation Inspection Procedure .................................................................................................. 84
Confidential
MTP02P Series Installation Manual v1.0 vii Copyright © 2018, All Rights Reserved.
List of Tables
Table 1. Specifications ................................................................................................................................... 3
Table 2. Basic Installation Tools ..................................................................................................................... 6
Table 3. Parts and Tools for Assembling Fixed Bracket Assembly ............................................................... 16
Table 4. Parts and Tools for Assembling Scissors Bracket Assembly ........................................................... 19
Table 5. Parts and Tools for fixing Scissors Bracket Assembly to the MMU ................................................ 22
Table 6. Parts and Tools for fixing Fixed Bracket Assembly to the MMU .................................................... 23
Table 7. Tools for fixing MMU on the Pole_Down Tilting Installation ......................................................... 26
Table 8. Parts and Tools for Assembling Mounting Bracket_Top Assembly ................................................ 30
Table 9. Parts and Tools for Assembling Mounting Bracket_Top Assembly ................................................ 33
Table 10. Parts and Tools for fixing Fixed Bracket Assembly to the MMU .................................................... 36
Table 11. Parts and Tools for fixing Scissors Bracket Assembly to the MMU ................................................ 37
Table 12. Tools for fixing MMU on the Pole_Up Tilting Installation .............................................................. 40
Table 13. Tools for Marking ........................................................................................................................... 44
Table 14. Parts and Tools for Drilling & Anchoring ........................................................................................ 46
Table 15. Anchor Bolt Drill Bits and Hole Depth ............................................................................................ 47
Table 16. Parts and Tools for Assembling Fixed Bracket Assembly ............................................................... 48
Table 17. Parts and Tools for Assembling Scissors Bracket Assembly ........................................................... 50
Table 18. Parts and Tools for fixing Scissors Bracket Assembly to the MMU ................................................ 54
Table 19. Parts and Tools for fixing Fixed Bracket Assembly to the MMU .................................................... 55
Table 20. Tools for fixing MMU on the Wall .................................................................................................. 57
Table 21. MMU Down Tilting Adjustment Tools ............................................................................................ 59
Table 22. MMU Up Tilting Adjustment Tools................................................................................................. 62
Table 23. Recommended Minimum Allowed Cable bend Radius .................................................................. 68
Table 24. MMU Connection Cable ................................................................................................................. 71
Table 25. Parts and Tools for MMU Grounding ............................................................................................. 72
Table 26. Parts and Tools for connecting Power Cable ................................................................................. 77
Table 27. Power Cable/Connector Pin Map ................................................................................................... 77
Table 28. Parts and Tools for LINK Cable Connection .................................................................................... 80
Table 29. Construction Situation Check list ................................................................................................... 85
Table 30. Standard Torque Value for Fastening Bolts ................................................................................... 91
Table 31. Brass Bolts Torque Value................................................................................................................ 91
Table 32. Connector Connection Torque Value ............................................................................................. 91
Confidential
MTP02P Series Installation Manual v1.0 viii Copyright © 2018, All Rights Reserved.
Preface
This manual describes how to install the 2.5 GHz MMU including how to connect cables. This manual includes the following 2.5 GHz MMU:
MTP02P-41A
Conventions in this Document
Samsung Networks product documentation uses the following conventions.
Symbols
Symbol
Description
Indicates a task.
Indicates a shortcut or an alternative method.
Provides additional information.
Provides information or instructions that you should follow to avoid service failure or damage to equipment.
Provides information or instructions that you should follow to avoid personal injury or fatality.
Provides antistatic precautions that you should observe.
Menu Commands
menu | command
This indicates that you must select a command on a menu, where menu is the name of the menu, and command is the name of the command on that menu.
File Names and Paths
These are indicated by a bold typeface. For example: Copy filename.ext into the /home/folder1/folder2/bin/ folder.
User Input and Console Screen Output Text
Input and output text is presented in the Courier font. For example,
context <designated epc-context-name>
CLI commands are presented in bold small caps. For example, Type the RTRV-NE-STS command in the input field.
Confidential
Preface
MTP02P Series Installation Manual v1.0 ix Copyright © 2018, All Rights Reserved.
Revision History
The following table lists all versions of this document.
Document Version
Publication Date
Remarks
1.0
April 2018
First Version
Organization of This Document
Section
Title
Description
Chapter 1
Before Installation
This chapter introduces MMU and describes items should be understood before installation.
Chapter 2
Installing System
This chapter describes the procedures to install the MMU.
Chapter 3
Connecting Cables
This chapter describes the procedures to connect the cables to the MMU installed.
Chapter 4
Inspect the Installation
This chapter describes the procedures of inspecting installation status after MMU installation and cabling is completed.
Appendix A
Acronyms
This annex describes the acronyms used in this manual.
Appendix B
Clean the Optical Connectors
This annex describes the procedure of cleaning the optical connector and cleaning tool.
Appendix C
Standard Torque
This annex describes the standard torque when fastening the bolt.
Related Documentation
LTE SMBS System Description
Confidential
Preface
MTP02P Series Installation Manual v1.0 x Copyright © 2018, All Rights Reserved.
Personal and Product Safety
This product safety information includes European directives, which you must follow. If these do not apply in your country, please follow similar directives that do apply in your country.
Proposition 65 (US Only)
State of California Proposition 65 Warning (US only) WARNING: This product contains chemicals known to the State of California to
cause cancer and birth defects or other reproductive harm.
Electrical
The product is designed to operate from a -48 V DC supply and is therefore classified as Safe Extra Low Voltage (SELV) equipment.
All structural parts are grounded and all input and outputs have built-in isolation from the network. All input and output ports that connect to external power sources are designed to meet relevant national safety requirements.
The product contains hazardous energy levels as defined by EN 60950. Care must be taken when maintaining this equipment as injury to personnel or damage to the equipment could result from mistakes. Maintenance should only be carried out by trained and competent engineers who are familiar with the relevant procedures and instructions.
Lasers
The product is fitted with optical modules rated as Class 1 radiation-emitting devices under EN 60825-1. During installation, operation, and maintenance, never look into the end of an optical fiber directly or by reflection either with the naked eye or through an optical instrument. Do not operate equipment with exposed fiber connectors-cover these with fiber cables or blanking caps. Do not remove equipment covers during operation unless requested to do so in the documentation. Carry out normal safety precautions when trimming fibers during installation.
Manual Handling
Care should be taken when handling equipment. Give due consideration to the weight of the equipment, the physical capability of the individual(s) handling the equipment, and movements such as twisting, bending and stooping, which could lead to skeletal and muscular injuries.
Installation
Installation must be carried out by trained and competent engineers only. All relevant safety measures should be taken to ensure equipment is not connected to
Confidential
Preface
MTP02P Series Installation Manual v1.0 xi Copyright © 2018, All Rights Reserved.
live power and transmission sources during installation. Equipment must be correctly installed in order to meet the relevant safety standards and approval conditions.
Each power feed to the unit requires a separate fused feed from the provided power supply. The cable between the power distribution point and the installed equipment must have a minimum cross-sectional area of 10 mm2.
Maintenance
Maintenance must only be carried out by a suitably trained and competent technician. All safety instructions must be carefully observed at all times. Equipment covers should not be removed while live power and transmission is connected unless in a controlled environment by trained technicians.
Fire
The product is powered from a -48 V DC supply. To protect against fire, the equipment is fused.
Environment
The product must be operated in an environment with the specified relative humidity and ambient temperature ranges.
Keep all liquids away from the equipment as accidental spillage can cause severe damage.
Cooling
The product is natural convection cooling type.
Anti-Static Precautions
The circuit boards and other modules in the product are sensitive to and easily damaged by static electricity. If any card or sub-assembly is removed from the unit, the following anti-static precautions must be observed at all times:
Service personnel must wear anti-static wrist straps. Circuit boards and sub-assemblies must be placed on ground conductive mats
or in conductive bags.
All tools must be discharged to ground before use. The anti-static wrist strap and cord must be checked at regular intervals for
their suitability for use.
Grounding
To comply with EN 60950, the equipment must be connected to a safety
grounding point via a permanent link. Grounding points are located on the product for this purpose. Always connect the ground cable before fitting other cables. The product must remain grounded continuously unless all connections to the power supply and data network are all removed.
If equipment is grounded through a cabinet or rack, make sure it is done so properly according to the installation instructions.
Power Supply Connection
The equipment is designed to be powered from a -48 V DC supply. Power connections and installation of associated wiring must be carried out by a suitably qualified technician.
Only devices that comply with all relevant national safety requirements should be connected to the unit's power supply inlets. Other usage will invalidate any approval given to this equipment.
Connection of this equipment to devices that are not marked with all relevant national safety requirements may produce hazardous conditions on the network.
Confidential
Preface
When the power supply is obtained by a rectifier/safety isolation transformer, the supply must meet the requirements of EN 60950 providing double/reinforced insulation between hazardous voltages and SELV/TNV circuits. Any battery must be separated from hazardous voltages by reinforced insulation.
Indirect Connection
Before indirectly connecting any equipment to another device through a shared power supply, ALWAYS seek advice from a competent engineer.
Devices that are not marked according to the relevant national safety standards may produce hazardous conditions on the network.
Product Disposal
To reduce the environmental impact of products, Samsung has joined WEEE compliance activities.
The WEEE symbol on the product indicates that the product is covered by the European Directive 2002/96/CE for the disposal of Waste Electrical and Electronic Equipment (WEEE). This means that the product should be disposed of separately from the municipal waste stream via designated collection facilities appointed by the government or the local authorities. This will help prevent potential negative consequences for the environment and human health. Please check the terms and conditions of the purchase contract for information about correct disposal.
California USA Only
This Perchlorate warning applies only to primary CR (Manganese Dioxide) Lithium coin cells in the product sold or distributed ONLY in California USA
Perchlorate Material-special handling may apply, See
MTP02P Series Installation Manual v1.0 xii Copyright © 2018, All Rights Reserved.
www.dtsc.ca.gov/hazardouswaste/perchlorate.’
FCC Statement
Any changes or modifications not expressly approved by the party responsible for
compliance could void the user's authority to operate this equipment.
This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more of the
following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which
the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Confidential
Preface
MTP02P Series Installation Manual v1.0 xiii Copyright © 2018, All Rights Reserved.
Confidential
Preface
MTP02P Series Installation Manual v1.0 xiv Copyright © 2018, All Rights Reserved.
Equipment Markings
This marking on the product, accessories or literature indicates that the product and its electronic accessories (e.g. charger, headset, USB cable) should not be disposed of with other household waste at the end of their working life. To prevent possible harm to the environment or human health from uncontrolled waste disposal, please separate these items from other types of waste and recycle them responsibly to promote the sustainable reuse of material resources.
Household users should contact either the retailer where they purchased this product, or their local government office, for details of where and how they can take these items for environmentally safe recycling.
Business users should contact their supplier and check the terms and conditions of the purchase contract. This product and its electronic accessories should not be mixed with other commercial wastes for disposal.
Hot surface warning
Allow to cool before servicing. Do not touch before cooling. Notice! Be careful not to touch due to high temperature. The system must be installed in a restricted area, and make sure the work is
done by personnel properly trained for the job.
Protective earth
MMU should be grounded.
Confidential
MTP02P Series Installation Manual v1.0 1 Copyright © 2018, All Rights Reserved.
Chapter 1 Before
Installation
System Configuration and Interface
MMU Configuration
The configuration of MMU is as follows.
MMU Configuration
Unit: in. (mm)
19.7 (500)
[Bottom View]
[Top View]
[Front View]
5.5 (140)
[Right View]
[Left View]
41.3 (1050)
[Rear View]
Confidential
Chapter 1 Before Installation
MTP02P Series Installation Manual v1.0 2 Copyright © 2018, All Rights Reserved.
MMU Interface
The interface structure of MMU is as follows.
MMU Interface
DC_PWR
LINK
Ground Terminal
[MMU Bottom View]
Confidential
Chapter 1 Before Installation
MTP02P Series Installation Manual v1.0 3 Copyright © 2018, All Rights Reserved.
Specifications
The table below lists the main specifications of the MMU.
Table 1. Specifications
Item
MTP02P-41A
Air technology
TDD LTE
Operating Frequency (MHz)
2,496~2,690
Channel Bandwidth (MHz)
15/20
CDU~MMU Interface
CPRI 4.2
Input Voltage
-48 V DC (-38~57 V DC)
Input Current
27 A @-48 V DC
Power Consumption
Max: 1530 W, Typical: 1305 W
Dimensions (mm)
500 (W) × 137.5 (D) × 1050 (H)
Weight (kg)
Less than 60
Operating Temperature
-40~55°C
Operating Humidity
5~100 % RH
Altitude
-60~1800 m
Earthquake
Telcordia Earthquake Risk Zone4 (Telcordia GR-63­CORE)
Vibration in Use Transportation Vibration
5~100 Hz, 0.15 grms (Telcordia GR-63-CORE) 5~200 Hz, 0.89 grms (Telcordia GR-63-CORE)
EMC
FCC part 15 subpart B
Safety
EN 60950-1 EN 60950-22
RF
FCC part27
Confidential
Chapter 1 Before Installation
MTP02P Series Installation Manual v1.0 4 Copyright © 2018, All Rights Reserved.
Cautions for Installation
Observe the following safety instructions when installing the system: Installation shall be in accordance with the applicable local electric codes.
Before Installing
Post warning signs in areas where high-voltage cables are installed. Post ‘off limit’ signs in areas where accidents are most expected. With guardrails or fences, block open areas such as connecting parts, roof, and
scaffold.
Install the system in the Restrict Access Area.
While Installing
The system power must be cut off before installing. Be careful not to damage or scratch the boards mounted on the system and the
cables among the boards when the system is transported or installed.
Make sure the power switch of power supply is off when installing the system.
Installing the system with power switch on may cause system damage or fatal human injury when cables are not correctly connected.
Make sure that worker wears protection gloves and goggles to prevent damage
from debris while drilling holes in a wall or ceiling.
Do not wear accessories such as watches and rings in order to prevent electrical
shock.
Never allow foreign substances to be inserted into unused ports by covering them
with a cap.
To prevent foreign substances, outdoor air and moisture from entering the cable
inlet (including cable gland and conduit), finish it as follows:
- Unused inlet: Use the hole finishing materials including cap and rubber packing.
- Cable-installed inlet: After cable installation, block any space in the inlet with tape, compressed sponge, rubber packing, and silicon.
When operator installs the MMU, the MMU must be within the protective angle
(left/right side 45° each from the central axis) to prevent the MMU from lightning
Confidential
Chapter 1 Before Installation
MTP02P Series Installation Manual v1.0 5 Copyright © 2018, All Rights Reserved.
damage.
After Installing
Remove any debris produced during the work and clean up the installation site.
In the system, the laser beam light runs through the optical cable. Handle the
optical cables with care as the laser beam can seriously damage the worker’s eyes.
Make sure that worker does not damage installed cables while cleaning the system. While cleaning the power supply device, take caution that the device does not
come in contact with foreign objects that may cause power failure.
Lightning Rod
45°
45°
MMU
Confidential
Chapter 1 Before Installation
MTP02P Series Installation Manual v1.0 6 Copyright © 2018, All Rights Reserved.
Installation Tools
The basic tools for installation are listed in the table below. The additional tools required for each site need to be identified and prepared during a site survey before starting installation.
Table 2. Basic Installation Tools
No.
Name
Specification
Purpose of use
1
Torque Driver
Apply a torque range : 6-22 lbf·in
For fastening M4 Screw
Apply a torque range : 20-90 lbf·in
For fastening M6 SEMS (Hex.+)
2
Screw Driver Bit '+', No. 2
For fastening M4 screw fixing
'+', No. 3
For fastening M6 screw fixing
3
Screw Driver
'+', No. 2
For fastening M4 screw fixing
'+', No. 3
For fastening M6 screw fixing
4
Torque Wrench
Apply a torque range : 100-400 lbf·in
For fastening M8, M12 hex. Bolt and nut.
5
Torque Wrench Spanner Head
Apply Hex. Head: 13 mm (for 100-400 lbf·in)
For fastening M8 Hex. bolt
Apply Hex. Head: 19 mm (for 100-400 lbf·in)
For fastening M12 flange, Hex. nut
6
Spanner
Hex. Head: 13 mm
For loosening the M8 Hex. Bolt
Hex. Head: 19 mm
For loosening the M12 Hex. Nut
7
Tape Measure
16 ft./150 ft.
Tape measure for length measurement 8
Level
Normal
For horizontality of MMU, and so on
9
Power Extension Cable
100 ft.
Basic tool
10
Heating Gun
122~572°F (50~300°C)
Shrinking heat shrink tube
Confidential
Chapter 1 Before Installation
MTP02P Series Installation Manual v1.0 7 Copyright © 2018, All Rights Reserved.
No.
Name
Specification
Purpose of use
11
Hammer Drill
Normal
Wall Type Drilling
12
Concrete Drill Bit
0.67 in. (17 mm)
For M12 Set Anchor
13
Anchor Punch
M12
For M12 Set Anchor
14
Hammer
Normal
Anchor fixing
15
Cable Cutter
0.24-1.26 in. (6-32 mm)
Cable cutting
16
Crimping Tool
14 AWG-4 AWG (1.5-16 mm2)
Pressure terminal for crimping 17
Ratchet Wrench
10 × 13/17 × 19 (4 in 1)
For fastening Hex. Bolt
18
Cable Stripper
Apply cable thickness: 1.5-6.2 in. (4-16 mm)
Cable sheath for removal
19
Nipper
Basic Tool
For cutting cable & cable tie
20
Industrial Scissor
Basic Tool
Cutting 21
Knife
Basic Tool
Cutting
22
Multi tester
Digital Pocket Tester
The voltage and current measurements Whether measured cable disconnection
23
Angle Meter
Normal
MMU angle measurement
24
Compass
Normal
Check azimuth during installation 25
Permanent Marker
Should be marked ‘Permanent’
on the pen (Black Color, 2 mm Tip)
After system installation, I-marking To mark the site ID, Name on the name
plate, and so on.
Confidential
Chapter 1 Before Installation
MTP02P Series Installation Manual v1.0 8 Copyright © 2018, All Rights Reserved.
No.
Name
Specification
Purpose of use
(Not to erase permanently) 26
Optical Connector Cleaner
For LC Connector
For Optical Connector Cleaning
The required installation tools may vary depending on the conditions at the site.
In addition to the basic tools, a protractor, ladder, safety equipment, cleaning tools, and so on should also be prepared in consideration of the site conditions.
Confidential
MTP02P Series Installation Manual v1.0 9 Copyright © 2018, All Rights Reserved.
Chapter 2 Installing System
Installation Procedure
The procedure to install the MMU is as follows:
Procedure to Install the MMU
Make sure that the power switch of the power supply is OFF when installing the
system. Installing the system with the power switch ON may cause system damage or fatal human injury when connecting or disconnecting the cables.
To prevent the risk of electrical shock do not wear accessories such as watches and
rings.
Foundation Work
Unpacking and Transporting
Unpacking Items
Bringing in Items
Assembling Bracket Assembly
Fixing Bracket Assembly
Lifting MMU
Fixing MMU
Fixing System
Tilting System
Transporting MMU
Handling System
Marking and Drilling (only wall type)
Confidential
Chapter 2 Installing System
MTP02P Series Installation Manual v1.0 10 Copyright © 2018, All Rights Reserved.
System Arrangement
A minimum distance must be secured around the MMU, in each direction for installation and maintenance.
MMU Arrangement_Pole Type
The dimensions of the front of the MMU change according to the tilt angle, and
the maximum dimensions are described in the figure below.
[Front View]
[Top View]
12 (
300)
16 (
400)
8 (200)
18 (
459)
32 (
800)
8 (200)
W: 19.7 (500)
H: 41.3 (1050)
Pole
Unit: in. (mm)
Confidential
Chapter 2 Installing System
MTP02P Series Installation Manual v1.0 11 Copyright © 2018, All Rights Reserved.
MMU Arrangement_Pole Type_Up/Down Tilting
When fixing a mounting bracket, the length of stud bolts are 220 mm for the pole
diameter 50~100 A.
Pole
Size
Stud Bolt
Pole Size (Diameter)
Length of Stud Bolt
50 A, 65 A, 80 A, 90 A, 100 A
220 mm
[Down Tilting 15o]
[Right View]
[Left View]
26.4 (670)
[Up Tilting 15o]
Unit: in. (mm)
27.7 (704)
Confidential
Chapter 2 Installing System
MTP02P Series Installation Manual v1.0 12 Copyright © 2018, All Rights Reserved.
MMU Arrangement_Wall Type
The dimensions of the front of the MMU change according to the tilt angle, and
the maximum dimensions are described in the figure below.
[Front View]
[Top View]
12 (
300)
16 (
400)
8 (200)
12 (307)
32 (
800)
8 (200)
W: 19.7 (500)
H: 41.3 (1050)
Unit: in. (mm)
Wall
Confidential
Chapter 2 Installing System
MTP02P Series Installation Manual v1.0 13 Copyright © 2018, All Rights Reserved.
MMU Arrangement_Wall Type_Up/Down Tilting
[Down Tilting 15o]
[Right View]
[Left View]
20.4 (519)
[Up Tilting 15o]
Unit: in. (mm)
21.8 (553)
Confidential
Chapter 2 Installing System
MTP02P Series Installation Manual v1.0 14 Copyright © 2018, All Rights Reserved.
Unpacking and Transporting
This paragraph describes the work to unpack cabinets and other components and transport them to the place to be installed.
Bringing in Items
Bring in items, taking care of the followings:
When carrying a system, fasten the system firmly to the transport vehicle or
carrier to prevent damage to the system for a vibration or shock.
When carrying system, use a lift to prevent accidents. However, if the system
must be carried by people, enough people are required to carry the system.
Before moving the system, check the storage place for the system and remove
obstacles in advance.
While moving system, the system should not be shocked physically and
damaged caused by dust, moisture, and static electricity.
Unpacking Items
The procedure to unpack items is as follows:
The packing items must be packed until they reach the installation place. The items are classified in accordance with each job specification and stored
on a place that does not interfere with working.
Unpacked systems must be installed immediately. If not installed immediately,
the systems must be stored in the installation place temporarily.
Unpack only external packing, leaving the internal packing in unpacked status. Unpack the inner packaging after each system is placed on its installation
location.
Scrap by-products (packaging waste) in accordance with the rule. Do not
recycle the by-products.
Confidential
Chapter 2 Installing System
MTP02P Series Installation Manual v1.0 15 Copyright © 2018, All Rights Reserved.
Handling the System
Transporting the MMU
When moving the MMU or its packaging box, use the handles located on both sides of the MMU or its packaging box.
Lifting Hazard
Single person lift could cause injury. Get help when moving or lifting.
Transporting the MMU
Packaging Box Handle
MMU Handle
[MMU Rear]
[Transporting the Packaging Box]
[Transporting the MMU]
Confidential
Chapter 2 Installing System
MTP02P Series Installation Manual v1.0 16 Copyright © 2018, All Rights Reserved.
Fixing System
Fixing Pole Type_Down Tilting Installation
Assembling Bracket Assembly_Down Tilting Installation
To assemble Fixed Bracket Assembly
1 Make sure you have the following items:
Table 3. Parts and Tools for Assembling Fixed Bracket Assembly
Category
Description
Parts
Fixed Bracket Assembly
1 EA
Rear Bracket
1 EA
Fasteners M12 Stud Bolt Assembly
4 EA
M12 Flange Nut
4 EA
Recommended Torque Value
M12 Flange Nut
372 lbf·in
Working Tools
Torque Wrench (100~400 lbf·in) Torque Wrench Spanner head (apply Hex. Head: 19 mm) Spanner (Hex. Head: 19 mm)
2 Loosen the flange nut by turning it two turns to the left, and attach the unit
bracket tilt down.
Assembling Fixed Bracket Assembly_Down Tilting Installation (1)
3 Pass the stud bolt assembly through the front bracket holes.
Unit Bracket
M12 Flange Nut