The Information Described in this Specification is Preliminary and can be changed without
prior notice
Samsung Display Co . , LTD.
MODELLTA260AP10Doc. No06-000-G-20120405Page/ 26
1
Page 2
Contents
Samsung Secret
Revision History -------------------------------------------------------------------------------------------- (3)
General Description --------------------------------------------------------------------------------------- (4)
General Information --------------------------------------------------------------------------------------- (4)
1. Absolute Maximum Ratings -------------------------------------------------------------------------- (5)
9. General Precaution ------------------------------------------------------------------------------------ (24)
9.1 Handling
9.2 Storage
9.3 Operation
9.4 Operation Condition Guide
9.5 Others
MODELLTA260AP10Doc. No06-000-G-20120405Page/ 26
2
Page 3
Revision History
Samsung Secret
Date
05. Apr.
2012
Rev.
No
000AllFirst issued
PageSummary
MODELLTA260AP10Doc. No06-000-G-20120405Page/ 26
3
Page 4
General Description
Samsung Secret
Description
LTA260AP10 is a color active matrix liquid crystal display (LCD) that uses amorphous silicon TFT
(Thin Film Transistor) as switching components. This model is composed of a TFT LCD panel, a
driver circuit and a back light unit. The resolution of a 26.0“ is 1366 x 768 and this model can
display up to 16.7 million colors with wide viewing angle of 89° or higher in all directions. This
panel is intended to support applications to provide a excellent performance for Flat Panel Display
such as Home-alone Multimedia TFT-LCD TV and High Definition TV
Features
RoHS compliance (Pb-free)
High contrast ratio & aperture ratio with wide color gamut
Low Power consumption
Edge Type LED (Light Emitted Diode) BLU
DE (Data Enable) mode
1Ch LVDS (Low Voltage Differential Signaling) interface (1pixel/clock)
General Information
ItemsSpecificationUnitNote
Module Size
Weight4240(Max)g
Pixel Pitch
Active Display Area575.769 (H) X 323.712 (V)mm
Surface TreatmentHaze 14%, Hard-coating(3H)
Display Colors8 bit – 16.7 Mcolors
Number of Pixels1366 x 768pixel
Pixel ArrangementRGB vertical stripe
Display ModeNormally Black
Luminance of White350 (Typ.)cd/m
609.8 (H) X 357.8 (V)
15.6(D max)With converter
0.4215 (H) × 0.1405 (V)
mm
mm
2
±1.0mm
MODELLTA260AP10Doc. No06-000-G-20120405Page/ 26
4
Page 5
Samsung Secret
1. Absolute Maximum Ratings
If the condition exceeds maximum ratings, it can cause malfunction or unrecoverable
damage to the device.
ItemSymbolMin.Max.UnitNote
Power Supply VoltageV
Storage temperatureT
Operating temperatureT
DD
STG
OPR
GND-0.513.2V(1)
-2060
050
℃
℃
Shock ( non - operating )X,Y,Z-50G(3)
Vibration ( non - operating )V
Note (1) Ta= 25 ± 2 °C
(2) Temperature and relative humidity range are shown in the figure below.
a. 90 % RH Max. (Ta ≤ 39 °C)
b. Relative Humidity is 90% or less. (Ta >39 °C)
c. No condensation
(3) 11ms, sine wave, one time for ±X, ±Y, ±Z axis
(4) 10-300 Hz, Sweep rate 10min, 30min for X,Y,Z axis
NOP
-1.5G(4)
(2)
Fig. Temperature and Relative humidity range
MODELLTA260AP10Doc. No06-000-G-20120405Page/ 26
5
Page 6
2. Optical Characteristics
The optical characteristics should be measured in a dark room or equivalent.
Measuring equipment : TOPCON RD-80S, TOPCON SR-3, ELDIM EZ-Contrast
Samsung Secret
(Ta = 25 ± 2°C, VDD=12V, fv= 60Hz, f
= 78MHz, DC Current, Duty 100%)
DCLK
ItemSymbolConditionMin.Typ.Max.UnitNote
Contrast Ratio
(Center of screen)
Response
Time
G-to-GTg
Luminance of White
(Center of screen)
Red
C/R-3000-
-8-msec
Y
L
Rx
Ry0.334
Normal
qL,R =0
-350-cd/m
0.649
qU,D =0
Gx0.300
Color
Chromaticity
(CIE 1931)
Green
Blue
Gy0.609
Bx0.150
Viewing
Angle
TYP.
-0.03
TYP.
+0.03
By0.053
Wx0.280
White
Wy0.290
Color Gamut--70-%
Color TemperatureCC-10000-K
2
(1)
SR-3
(3)
RD-80S
(4)
SR-3
(5),(6)
SR-3
(5)
SR-3
Hor.
Viewing
Angle
Ver.
White Brightness
Uniformity
(9 Points)
q
L
q
R
q
U
q
D
B
uni
C/R≥10
79897989-
Degree
79897989-
--30%
(6)
EZ-Contrast
(2)
SR-3
- Test Equipment Setup
The measurement should be executed in a stable, windless and dark room between
40min and 60min after lighting the back light at the given temperature for stabilization
of the back light. This should be measured in the center of screen.
Environment condition : Ta = 25 ± 2 °C
MODELLTA260AP10Doc. No06-000-G-20120405Page/ 26
6
Page 7
Samsung Secret
C R
G
G
/
max
min
Photo detectorField
SR-3
RD-80S
TFT - LCD Module
2°
1°
- Definition of test point
2276831139
Photo detector
Field
SR-3 : 50㎝
RD-80S : 50㎝
LCD Panel
The center of the screen
128
384
640
⑨
⑥
⑧
⑤④
②③
Note (1) Definition of Contrast Ratio (C/R)
: Ratio of gray max (Gmax) & gray min (Gmin) at the center point ⑤ of the panel
Gmax : Luminance with all pixels white
Gmin : Luminance with all pixels black
⑦
①
Active Area
Test Point
MODELLTA260AP10Doc. No06-000-G-20120405Page/ 26
7
Page 8
Samsung Secret
Buni
BB
B
100
(maxmin)
max
Note (2) Definition of 9 points brightness uniformity (Test pattern : Full White )
Bmax : Maximum brightness
Bmin : Minimum brightness
Note (3) Definition of Response time : Sum of Tr, Tf
Display data
Optical Instruments
Response
100%
90%
10%
0%
Black (data off)
White (data on)
T
R
Black (data off)
T
F
TIME
Note (4) Definition of Luminance of White : Luminance of white at center point ⑤
Note (5) Definition of Color Chromaticity (CIE 1931)
Color coordinate of Red, Green, Blue & White at center point ⑤
Note (6) Definition of Viewing Angle
: Viewing angle range (C/R ≥10)
MODELLTA260AP10Doc. No06-000-G-20120405Page/ 26
8
Page 9
Samsung Secret
3. Electrical Characteristics
3.1 TFT LCD Module
The connector for display data & timing signal should be connected.
Ta = 25°C ± 2 °C
ItemSymbolMin.Typ.Max.UnitNote
Voltage of Power SupplyV
Current of
(a) Black
Power
Supply
(c) V-STRIPE-620820mA
Vsync Frequencyf
Hsync Frequencyf
Main Frequencyf
Rush CurrentI
DD
I
DD
V
H
DCLK
RUSH
10.812.013.2V(1)
-400-mA
506066Hz
444853kHz
727885MHz
--4A(4)
Note (1) The ripple voltage should be controlled under 10% of VDD.
(2) fV=60Hz, fDCLK = 78MHz, VDD= 12.0V, DC Current.
(3) Power dissipation check pattern (LCD Module only)
a) Black Pattern b) White Pattern c) V-STRIPE
(2),(3)(b) White-500-mA
(4) Measurement Conditions
V
100%
DD
90%
10%
GND
T
=470㎲
RUSH
Rush Current I
MODELLTA260AP10Doc. No06-000-G-20120405Page/ 26
can be measured when T
RUSH
. is 470㎲.
RUSH
9
Page 10
Samsung Secret
3.2 Back Light Unit
The back light unit contains Edge type White LEDs (Light Emitting Diode)
Ta=25 ± 2°C
Converter
Control Board
LCD Module
ItemSymbolMin.Typ.Max.UnitNote
Operating Life TimeHr30,000--Hour(1)
Note (1) It is defined as the time to take until the brightness reduces to 50% of its original
value.
[Operating condition : Ta = 25±2℃, For single LED bar only. ]
MODELLTA260AP10Doc. No06-000-G-20120405Page/ 26
10
Page 11
3.3 Converter Input Condition & Specification
ItemsSymbolConditions
Min.Typ.Max.
Samsung Secret
Specifications
UnitNote
Input VoltageVin-222426V
Input CurrentI
Output
Current
Backlight
On/Off
Dimming RangeV
Dimming Duty
Output
Dimming
Frequency
External Dimming
Duty Range
External Dimming
Frequency Range
RUSH
I
O,MAX
ENA
_DIM
D maxVin=24V Dim:3.3V100--
D minVin=24V Dim:0V1--
F
PWM
EX_Dim
F
EX_PWM
Vin=24.0V
Vdim =3.3V
Vin = 24.0V
V dim =3.3 V
ON2.4-5.2
OFF0-0.8
Vin :21.6~26.4V0-3.3V
Vin=24.0 V140150160Hz
Vin=21.6~26.4 V
Dim Pin(#13)
: Floating
--2.0A
133140147mArms
1-100%
100-200Hz
%
Ta=25±2 °C
V
(2)
(2)
(2)
External Dimming
Signal Level
V
PWM
High (ON)3.0-5.5
V
Low (Off)-0.3-0.8
Note) Power Consumption is measured when 350 [cd/m ] of luminance which is the typical
luminance.
(1) All data is measured after 120min warm-up.
(2) only use #Pin 13
MODELLTA260AP10Doc. No06-000-G-20120405Page/ 26
11
Page 12
4. Input Terminal Pin Assignment
Samsung Secret
4.1. Input Signal & Power Connector :IS100-L30O-C23
Rn : Red Gray, Gn : Green Gray, Bn : Blue Gray (n = Gray level)
Input Signal : 0 = Low level voltage, 1 = High level voltage
MODELLTA260AP10Doc. No06-000-G-20120405Page/ 26
16
Page 17
5. Interface Timing
Samsung Secret
5.1 Timing Parameters ( DE mode )
SIGNALITEMSYMBOLMIN.TYP.MAX.UnitNOTE
Clock
HsyncF
Frequency
VsyncF
Active
Display
Period
Vertical
Display Term
Vertical
Total
Active
Display
Period
Horizontal
Display Term
1/T
T
T
T
H
V
VD
V
HD
C
727885MHz-
444853KHz-
506066Hz-
-768-Lines-
7748021200Lines-
-1366-Clocks-
Horizontal
Total
T
H
146016242000clocks-
Note) This product is DE mode. But the Hsync & Vsync signal must be inputted
(1) Test Point : TTL control signal and CLK at LVDS Tx input terminal in system
(2) Internal VDD = 3.3V
(3) Spread spectrum
- Modulation rate (max) : ± 1.5 % , Modulation Frequency : under 100KHz
MODELLTA260AP10Doc. No06-000-G-20120405Page/ 26
17
Page 18
5.2 Timing diagrams of interface signal ( DE mode )
TV
Samsung Secret
DE
DE
DCLK
DATA
SIGNALS
TVD
TVB
TH
THD
TC
TC
TCH
DCLK
TDSTDH
DISPLAY
DATA
TES
DE
MODELLTA260AP10Doc. No06-000-G-20120405Page/ 26
TCL
0.5
V
0.5
V
CC
0.5
V
CC
CC
18
Page 19
5.3 Power ON/OFF Sequence
Samsung Secret
To prevent a latch-up or DC operation of the LCD Module, the power on/off
sequence should be as the diagram below.
2 msec<T1≤10msec
0<T2≤50msec
0<T3≤50msec
1000msec≤T4
1000msec≤T5
(Recommend Value)
100msec≤T6
(Recommend Value)
0.5 Vcc
T1 : VDDrising time from 10% to 90%
T2 : The time from VDDto valid data at power ON.
T3 : The time from valid data off to VDDoff at power Off.
T4 : VDDoff time for Windows restart
T5 : The time from valid data to B/L enable at power ON.
T6 : The time from valid data off to B/L disable at power Off.
The supply voltage of the external system for the Module input should be the same
as the definition of VDD.
Apply the LED voltage within the LCD operation range. When the back light turns on
before the LCD operation or the LCD turns off before the back light turns off,
the display may momentarily show abnormal screen.
In case of VDD= off level,
please keep the level of input signals low or keep a high impedance.
T4 should be measured after the Module has been fully discharged between power off
and on period.
Interface signal should not be kept at high impedance when the power is on.
In Case T5 is less than 1000msec and T6 is less than 100msec,
Garbage Display can be seen. (It is not related to electrical function issue, Just for
recommendation to prevent Garbage Display )
MODELLTA260AP10Doc. No06-000-G-20120405Page/ 26
19
Page 20
6. Outline Dimension- Front
Samsung Secret
TBD
MODELLTA260AP10Doc. No06-000-G-20120405Page/ 26
20
Page 21
6. Outline Dimension- Rear
Samsung Secret
TBD
MODELLTA260AP10Doc. No06-000-G-20120405Page/ 26
21
Page 22
7. PACKING
7.1 CARTON (Internal Package)
(1) Packing Form
Corrugated fiberboard box and corrugated cardboard as shock absorber
(2) Packing Method
Samsung Secret
7.2 Packing Specification
ItemSpecificationRemark
LCD Packing
Pallet2 Box / Pallet1. Pallet Weight = 4.8 kg
Packing DirectionVertical
Total Pallet SizeH x V x Height1150mm(H) x 850(V) x 937(Height)
Total Pallet
Weight
MODELLTA260AP10Doc. No06-000-G-20120405Page/ 26
30 ea/
Box(Packing-
Pallet Box)
248.8 kg
1. 3.5kg / LCD(1ea)
2. 17kg / Packing-Pallet Box(1ea)
3. Packing-Pallet Box Material : Paper
Pallet(4.8kg) + BOX (17kg x 2ea)
+ Module(3.5kg x 60ea)
22
Page 23
Samsung Secret
8. MARKING & OTHERS
A nameplate bearing followed by is affixed to a shipped product at the specified
location on each product.
(1) Part number : LTA260AP10
(2) Revision: Three letters
(3) Lot number : X X X X XXX XX X
Cell Position No. (In the Glass)
Glass No. (In the one Lot)
Lot No. (Glass)
Month
Year (Note1)
Product code
Line
(4) Nameplate Indication
T
C
LTA260AP10
1005
XXXX
(5) Packing box attach
XXXXXXXXXXXXX
LTA260AP10
Week code : 10 05
week
year
40mm
Revision code
Lot number
80mm
100mm
Part number
XXX
60
Box serial number
165mm
(6) Others
1. After service part
LED cannot be replaced because of the narrow bezel structure.
MODELLTA260AP10Doc. No06-000-G-20120405Page/ 26
23
Page 24
9. General Precautions
Samsung Secret
9.1 Handling
(a) When the Module is assembled, it should be attached to the system firmly
using all mounting holes. Be careful not to twist and bend the Module.
(b) Because the Converter use high voltage, it should be disconnected from power
before it is assembled or disassembled.
(c) Refrain from strong mechanical shock and / or any force to the Module.
In addition to damage, this may cause improper operation or damage to the Module
and LED back light.
(d) Note that polarizers are very fragile and could be damage easily.
Do not press or scratch the surface harder than a HB pencil lead.
(e) Wipe off water droplets or oil immediately. If you leave the droplets for a long
time, staining or discoloration may occur.
(f) If the surface of the polarizer is dirty, clean it using absorbent cotton or soft cloth.
(g) Desirable cleaners are water, IPA(Isopropyl Alcohol) or Hexane.
Do not use Ketone type materials(ex. Acetone), Ethyl alcohol, Toluene, Ethyl acid
or Methyl chloride. It might permanent damage to the polarizer due to chemical
reaction.
(h) If the liquid crystal material leaks from the panel, it should be kept away
from the eyes or mouth . In case of contact with hands, legs or clothes, it must
be washed away with soap thoroughly.
(i) Protect the module from Electrostatic discharge. Otherwise the ASIC IC or
semiconductor would be damaged.
(j) Use finger-stalls with soft gloves in order to keep display clean during the
incoming inspection and assembly process.
(k) Do not disassemble the Module.
(l) Do not disassemble shield case of Converter & LVDS board
(m) Do not connect N.C pins. (Samsung internal use only)
(n) Protection film for polarizer on the Module should be slowly peeled off just before use
so that the electrostatic charge can be minimized. Must put on antistatic glove while
handling a module
(o) Pins of I/F connector should not be touched directly with bare hands.
MODELLTA260AP10Doc. No06-000-G-20120405Page/ 26
24
Page 25
9.2 Storage
We highly recommend to comply with the criteria in the table below.
ItemUnitMin.Max.
Samsung Secret
Storage
Temperature
Storage Humidity(%rH)3575
Storage Life6 Months
- The storage room should provide good ventilation and temperature
control.
- Products should not be placed on the floor, but on the Pallet away
from
a wall.
- Prevent products from direct sunlight, moisture nor water; Be
cautious of
Storage
Condition
a build up of condensation.
- Avoid other hazardous environment while storing goods.
- If products delivered or kept in conditions of over the storage period
of 3
months, the recommended temperature or humidity range,
we recommend you leave them at a temperature of 20℃ and a
humidity
of 50% for 24 hours.
(℃)
1040
9.3 Operation
(a) Do not connect or disconnect the Module in the "Power On" condition.
(b) Power supply should always be turned on/off by the "Power on/off sequence"
(c) Module has high frequency circuits. Sufficient suppression to the electromagnetic
interference should be done by system manufacturers. Grounding and shielding methods
may be important to minimize the interference.
(d) The cable between the back light connector and its converter power supply should
be connected directly with a minimized length. A longer cable between the back light
and the converter may cause lower luminance of CCFL and may require higher startup
voltage(Vs).
MODELLTA260AP10Doc. No06-000-G-20120405Page/ 26
25
Page 26
9.4 Operation Condition Guide
(a) The LCD product should be operated under normal conditions.
(b) If the product will be used in extreme conditions such as high temperature,
humidity, display patterns or operation time etc.., It is strongly recommended
to contact SEC for Application engineering advice. Otherwise, its reliability and
function may not be guaranteed. Extreme conditions are commonly found at
Airports, Transit Stations, Banks, Stock market, and Controlling systems.
Samsung Secret
9.5 Others
(a) Ultra-violet ray filter is necessary for outdoor operation.
(b) Avoid condensation of water. It may result in improper operation or disconnection
of electrode.
(c) Do not exceed the absolute maximum rating value. ( supply voltage variation,
input voltage variation, variation in part contents and environmental temperature,
and so on)
Otherwise the Module may be damaged.
(d) If the Module keeps displaying the same pattern for a long period of time,
the image may be "sticked" to the screen.
To avoid image sticking, it is recommended to use a screen saver.
(e) This Module has its circuitry PCB's on the rear side and should be handled
carefully in order not to be stressed.
(f) Please contact SEC in advance when you display the same pattern for a long time.
MODELLTA260AP10Doc. No06-000-G-20120405Page/ 26
26
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.