Samsung SH09AWH, SH09ZWH, AQ09WHWE, KFR-25G/SWA, SH12AWH Service Manual

...
ROOM AIR CONDITIONER
INDOOR UNIT
SH09AWH SH09ZWH AQ09WHWE KFR-25G/SWA SH12AWH SH12ZWH AQ12WHWE KFR-35G/SWA
SERVICE
OUTDOOR UNIT
SH09AWHX SH09ZWHX UQ09WHWE KFR-25W/SWA SH12AWHX SH12ZWHX UQ12WHWE KFR-35W/SWA
Manual
CONTENTSAIR CONDITIONER
1. Product Specifications
2. Disassembly and Reassembly
3. Set Up the Model Option
4. Exploded Views and Parts List
5. Block Diagram
6. Schematic Diagram
1. Product Specifications
1-1 Table
Item
Type
Cooling kW Heating kW Dehumidifying |/h
Air Volume
Perfor­mance
Noise
Energy Efficiency Ratio
Power V-Hz
Power Consumption
Operating Current
Power
Power Factor
Starting Current A
Power Cord Number of Core Wire
Outer Dimension
Weight(Net) kg
Refrigerant Pipe
Drain Hose D x L(mm)
Size
Compressor Motor Type
Oil Type
Blower Motor Type
Heat Exchanger Refrigerant Control Unit Freezer Oil Capacity cc Refrigerant to Change(R410A) g Protection Device(OLP) Cooling Test Condition Maximum Operation Condition
Type
Type
Cooling Heating Cooling Heating Cooling Heating
Cooling Heating Cooling Heating Cooling Heating
Length m
Capacity A Width x Height
x Depth
Liquid mm x L(m) GAS mm x L(m)
Rated Output
Rated Output W
Model
m3/min
dB
W/W
W
A
%
mm inch
SH09AWH SH12AWH
Indoor unit Outdoor unit
Wall-mounted
2.75
2.90
1.0
7.3 25
8.0 25 38 / 36 / 34 51 / 51 38 / 36 / 34 51 / 51
2.81
3.22
1-220 / 240-50
980 900
4.5
4.5
96.5
95.5
21.0
-
-
250V-10A
825x 285x 189 720x548 x265
32.5x 11.2 x 7.44 28.4x21.6 x10.4
8.2 31.3
ø6.35 x 7.5 ø9.52 x 7.5
ø18 x 550
Rotary
Induction Motor(PSC)
900
DAPHNE FV68S(PVE)
Cross-flow Propeller
steel steel
15 50
2ROW 14STEP 1ROW 24STEP
CAPILLARY TUBE
350 650
MRA99134-9201 INDOOR UNIT : DB27˚C WB19˚C OUTDOOR UNIT : DB35˚C WB24˚C INDOOR UNIT : DB32˚C WB23˚C OUTDOOR UNIT : DB43˚C WB26˚C
Indoor unit Outdoor unit
Wall-mounted
3.5
4.2
1.4
8.3 25
9.0 25 41 / 39 / 37 53 / 53 41 / 39 / 37 53 / 53
2.82
3.23
1-220 / 240-50
1,240 1,300
5.7
5.7
98.3
98.0
30.0
-
-
250V-10A
825x 285x 189 720x548 x265
32.5x 11.2 x 7.44 28.4 x 21.6x 10.4
8.4 33.8
ø6.35 x 7.5 ø9.52 x 7.5
ø18 x 550
Rotary
Induction Motor(PSC)
1,075
DAPHNE FV68S(PVE)
Cross-flow Propeller
steel steel
15 50
2ROW 14STEP 2ROW 24STEP
CAPILLARY TUBE
520
1,020
MRA99908-9201
1Samsung Electronics
Table(cont.)
Item
Type
Cooling kW Heating kW Dehumidifying |/h
Air Volume
Perfor-
mance
Noise
Energy Efficiency Ratio
Power V-Hz
Power Consumption
Operating Current
Power
Power Factor
Starting Current A
Power Cord Number of Core Wire
Outer Dimension
Weight(Net) kg
Refrigerant Pipe
Drain Hose D x L(mm)
Size
Compressor Motor Type
Oil Type
Blower Motor Type
Heat Exchanger Refrigerant Control Unit Freezer Oil Capacity cc Refrigerant to Change(R22) g Protection Device(OLP) Cooling Test Condition Maximum Operation Condition
Type
Type
Cooling Heating Cooling Heating Cooling Heating
Cooling Heating Cooling Heating Cooling Heating
Length m
Capacity A Width x Height
x Depth
Liquid mm x L(m) GAS mm x L(m)
Rated Output
Rated Output W
Model
m3/min
dB
W/W
W
A
%
mm
inch
SH12ZWHSH09ZWH
Indoor unit Outdoor unit
Wall-mounted
2.70
2.90
1.0
7.3 25
8.0 25 38 / 36 / 34 51 / 51 38 / 36 / 34 51 / 51
2.70
3.22
1-220 / 240-50
1,000
900
4.5
4.0
98.2
99.1
21.0
-
-
250V-10A
825x 285x 189 720x548 x265
32.5x 11.2 x 7.44 28.4 x 21.6x 10.4
8.2 31.3
ø6.35 x 5.0 ø9.52 x 5.0
ø18 x 550
Rotary
Induction Motor(PSC)
1,005
SUNISO-4GSD
Cross-flow Propeller
steel steel
15 50
2ROW 14STEP 1ROW 24STEP
CAPILLARY TUBE
360 580
RAC12110-9622 INDOOR UNIT : DB27˚C WB19˚C OUTDOOR UNIT : DB35˚C WB24˚C INDOOR UNIT : DB32˚C WB23˚C OUTDOOR UNIT : DB43˚C WB26˚C
Indoor unit Outdoor unit
Wall-mounted
3.5
4.0
1.4
8.3 25
9.0 25 41 / 39 / 37 53 / 53 41 / 39 / 37 53 / 53
2.99
3.48
1-220 / 240-50
1,170 1,150
5.2
5.2
96.9
96.2
30.0
-
-
250V-10A
825x 285x 189 720x 548x 265
32.5x 11.2 x 7.44 28.4 x21.6 x 10.4
8.4 33.8
ø6.35 x 5.0
ø12.70 x 5.0
ø18 x 550
Rotary
Induction Motor(PSC)
1,206
SUNISO-4GSD
Cross-flow Propeller
steel steel
15 50
2ROW 14STEP 2ROW 24STEP
CAPILLARY TUBE
600 980
RAC12074-9622
Samsung Electronics2
Table(cont.)
Item
Type
Cooling kW Heating kW Dehumidifying |/h
Air Volume
Perfor­mance
Noise
Energy Efficiency Ratio
Power V-Hz
Power Consumption
Operating Current
Power
Power Factor
Starting Current A
Power Cord Number of Core Wire
Outer Dimension
Weight(Net) kg
Refrigerant Pipe
Drain Hose D x L(mm)
Size
Compressor Motor Type
Oil Type
Blower Motor Type
Heat Exchanger Refrigerant Control Unit Freezer Oil Capacity cc Refrigerant to Change(R22) g Protection Device(OLP) Cooling Test Condition Maximum Operation Condition
Type
Type
Cooling Heating Cooling Heating Cooling Heating
Cooling Heating Cooling Heating Cooling Heating
Length m
Capacity A Width x Height
x Depth
Liquid mm x L(m) GAS mm x L(m)
Rated Output
Rated Output W
Model
m3/min
dB
W/W
W
A
%
mm inch
AQ12WHWEAQ09WHWE
Indoor unit Outdoor unit
Wall-mounted
2.70
2.90
1.0
7.3 25
8.0 25 38 / 36 / 34 51 / 51 38 / 36 / 34 51 / 51
2.70
3.22
1-220 / 240-50
1,000
900
4.5
4.0
98.2
99.1
21.0
-
-
250V-10A
825x 285x 189 720x548 x265
32.5x 11.2 x 7.44 28.4 x 21.6x 10.4
8.2 33.0
ø6.35 x 5.0 ø9.52 x 5.0
ø18 x 550
Rotary
Induction Motor(PSC)
1,005
SUNISO-4GSD
Cross-flow Propeller
steel steel
15 50
2ROW 14STEP 1ROW 24STEP
CAPILLARY TUBE
360 580
RAC12110-9622 INDOOR UNIT : DB27˚C WB19˚C OUTDOOR UNIT : DB35˚C WB24˚C INDOOR UNIT : DB32˚C WB23˚C OUTDOOR UNIT : DB43˚C WB26˚C
Indoor unit Outdoor unit
Wall-mounted
3.5
4.0
1.4
8.3 25
9.0 25 41 / 39 / 37 53 / 53 41 / 39 / 37 53 / 53
2.99
3.48
1-220 / 240-50
1,170 1,150
5.2
5.2
96.9
96.2
30.0
-
-
250V-10A
825x 285x 189 720x 548x 265
32.5x 11.2 x 7.44 28.4 x21.6 x 10.4
8.4 33.8
ø6.35 x 5.0
ø12.70 x 5.0
ø18 x 550
Rotary
Induction Motor(PSC)
1,206
SUNISO-4GSD
Cross-flow Propeller
steel steel
15 50
2ROW 14STEP 2ROW 24STEP
CAPILLARY TUBE
600 980
RAC12074-9622
3Samsung Electronics
Table(cont.)
Item
Type
Cooling kW Heating kW Dehumidifying |/h
Air Volume
Perfor-
mance
Noise
Energy Efficiency Ratio
Power V-Hz
Power Consumption
Operating Current
Power
Power Factor
Starting Current A
Power Cord Number of Core Wire
Outer Dimension
Weight(Net) kg
Refrigerant Pipe
Drain Hose D x L(mm)
Size
Compressor Motor Type
Oil Type
Blower Motor Type
Heat Exchanger Refrigerant Control Unit Freezer Oil Capacity cc Refrigerant to Change(R22) g Protection Device(OLP) Cooling Test Condition Maximum Operation Condition
Type
Type
Cooling Heating Cooling Heating Cooling Heating
Cooling Heating Cooling Heating Cooling Heating
Length m
Capacity A Width x Height
x Depth
Liquid mm x L(m) GAS mm x L(m)
Rated Output
Rated Output W
Model
m3/min
dB
W/W
W
A
%
mm
inch
KFR-25G/SWA KFR-35G/SWA
Indoor unit Outdoor unit
Wall-mounted
2.65
2.90
1.0
7.3 25
8.0 25 38 / 36 / 34 51 / 51 38 / 36 / 34 51 / 51
2.65
3.22
1-220-50
1,000
900
4.6
4.1 97 97
21.0
-
-
250V-10A
825x 285x 189 720x548 x265
32.5x 11.2 x 7.44 28.4 x 21.6x 10.4
8.2 31.3 ø6.35 x 4.0 ø9.52 x 4.0
ø18 x 550
Rotary(SAMSUNG)
Induction Motor(PSC)
990
SUNISO-4GSD/NOC
Cross-flow Propeller
steel steel
15 50
2ROW 14STEP 1ROW 24STEP
CAPILLARY TUBE
360 600
RAC12054-9622 INDOOR UNIT : DB27˚C WB19˚C OUTDOOR UNIT : DB35˚C WB24˚C INDOOR UNIT : DB32˚C WB27.5˚C OUTDOOR UNIT : DB43˚C WB33˚C
Indoor unit Outdoor unit
Wall-mounted
3.5
4.0
1.4
8.3 25
9.0 25 41 / 39 / 37 53 / 53 41 / 39 / 37 53 / 53
2.99
3.48
1-220-50
1,170 1,150
5.8
5.8 92 92
30.0
-
-
250V-16A
825x 285x 189 720x548 x265
32.5x 11.2 x 7.44 28.4 x 21.6x 10.4
8.4 33.8 ø6.35 x 4.0
ø12.70 x 4.0
ø18 x 550
Rotary(SAMSUNG)
Induction Motor(PSC)
1,210
SUNISO-4GSD/NOC
Cross-flow Propeller
steel steel
15 50
2ROW 14STEP 2ROW 24STEP
CAPILLARY TUBE
600 950
RAC12074-9622
Samsung Electronics4
2. Disassembly and Reassembly
Stop operation of the air conditioner and remove the power cord before repairing the unit.
2-1 Indoor Unit
No Parts Procedure Remark
1 Front Grille
1) Stop the air conditioner operation and block the main power.
2) Open the Front Grille by pulling right and left sides of the hook.
3) Loosen 1 of the right screw and detach the Terminal Cover.
4) Detach the thermistor from the Front Grille.
5) Loosen 2 fixing screws of Front Grille.
5Samsung Electronics
Disassembly and Reassembly
No Parts Procedure Remark
6) Unlock 2 hooks to fix Panel Front and Tray Drain.
7) Unlock 3 hooks to fix Panel Front and Back-Body.
2
Control-In
(Main PCB)
1) Take all the connector of PCB upper side out. (Inclusion Power Cord)
2) Detach the outdoor unit connection wire from the Terminal Block.
3) Loosen 4 fixing screws of Ass'y Control-In.
3
Tray Drain
1) Pull Tray Drain out from the Back Body.
Samsung Electronics6
Disassembly and Reassembly
No Parts Procedure Remark
4
Heat Exchanger
1) Loosen 2 fixing earth screws of right side.
2) Detach the Connection Pipe.
3) Detach the Holder Pipe at the rear side.
4) Loosen the 3 fixing screws of right and left side.
5) Lifting the Heat Exchanger up a little to push the up side for separation from the indoor unit.
5
Fan Motor
&
Cross Fan
1) Loosen the fixing screw and detach the Motor Holder.
2) Detach the Fan Motor from the Fan.
3) Detach the Fan From the left Holder Bearing.
7Samsung Electronics
2-2 Outdoor Unit
No Parts Procedure Remark
1 Common Work
1) Loosen each 3 fixing screws on both right and left Cabinet-Side edge and a fixing screw on the Cabinet-Front lower to detach the Cabinet-Front.
2) Loosen 2 fixing screws of the Ass'y-Control.
3) Loosen 6 fixing screws of the Cabinet-Side RH.
4) Loosen 2 fixing screws of the Cabinet-Side LF.
Samsung Electronics8