”YNN MacshbM·Rev. 1.01, Nov. 2010
K4B1G0446G
K4B1G0846G
1Gb G-die DDR3 SDRAM
78FBGA with Lead-Free & Halogen-Free (RoHS compliant)
datasheet
SAMSUNG ELECTRONICS RESERVES THE RIGHT TO CHANGE PRODUCTS, INFORMATION AND SPECIFICATIONS WITHOUT NOTICE.
Products and specifications discussed herein are for reference purposes only. All information discussed herein is provided on an "AS IS" basis, without warranties of any kind.
This document and all information discussed herein remain the sole and exclusive property of Samsung Electronics. No license of any patent, copyright, mask work, trademark or any other intellectual property right is granted by one party to the other party under this document, by implication, estoppel or otherwise.
Samsung products are not intended for use in life support, critical care, medical, safety equipment, or similar applications where product failure could result in loss of life or personal or physical harm, or any military or defense application, or any governmental procurement to which special terms or provisions may apply.
For updates or additional information about Samsung products, contact your nearest Samsung office.
All brand names, trademarks and registered trademarks belong to their respective owners.
2010 Samsung Electronics Co., Ltd. All rights reserved.
- 1 -
|
|
|
|
|
Rev. 1.01 |
K4B1G0846G |
|
|
”YNN MacshbM· |
||
|
datasheet |
DDR3 SDRAM |
|||
K4B1G0446G |
|
|
|
|
|
Revision History |
|
|
|
|
|
Revision No. |
|
History |
Draft Date |
Remark |
Editor |
1.0 |
- First release. |
|
Nov. 2010 |
- |
S.H.Kim |
1.01 |
- Corrected Typo. |
|
Nov. 2010 |
- |
S.H.Kim |
- 2 -
|
|
|
Rev. 1.01 |
|
|
”YNN MacshbM· |
|
K4B1G0846G |
datasheet |
DDR3 SDRAM |
|
K4B1G0446G |
|
|
|
Table Of Contents |
|
|
|
1Gb G-die DDR3 SDRAM |
|
|
|
1. Ordering Information ..................................................................................................................................................... |
|
5 |
|
2. Key Features................................................................................................................................................................. |
|
5 |
|
3. Package pinout/Mechanical Dimension & Addressing.................................................................................................. |
6 |
||
3.1 x4 Package Pinout (Top view) : 78ball FBGA Package .......................................................................................... |
6 |
||
3.2 x8 Package Pinout (Top view) : 78ball FBGA Package .......................................................................................... |
7 |
||
3.3 |
FBGA Package Dimension (x4/x8).......................................................................................................................... |
|
8 |
4. Input/Output Functional Description.............................................................................................................................. |
|
9 |
|
5. DDR3 SDRAM Addressing ........................................................................................................................................... |
|
10 |
|
6. Absolute Maximum Ratings .......................................................................................................................................... |
|
11 |
|
6.1 |
Absolute Maximum DC Ratings............................................................................................................................... |
|
11 |
6.2 DRAM Component Operating Temperature Range ................................................................................................ |
11 |
||
7. AC & DC Operating Conditions..................................................................................................................................... |
|
11 |
|
7.1 |
Recommended DC operating Conditions (SSTL_1.5)............................................................................................. |
11 |
|
8. AC & DC Input Measurement Levels ............................................................................................................................ |
|
12 |
|
8.1 |
AC & DC Logic input levels for single-ended signals .............................................................................................. |
12 |
|
8.2 |
VREF Tolerances...................................................................................................................................................... |
|
13 |
8.3 |
AC & DC Logic Input Levels for Differential Signals............................................................................................... |
14 |
|
8.3.1. Differential signals definition ................................................................ |
............................................................ |
14 |
|
8.3.2. Differential swing requirement for clock (CK - CK) and strobe (DQS - DQS) .................................................. |
14 |
||
8.3.3. Single-ended requirements for differential signals ........................................................................................... |
15 |
||
8.4 |
Differential Input Cross Point Voltage...................................................................................................................... |
|
16 |
8.5 |
Slew rate definition for Differential Input Signals ..................................................................................................... |
16 |
|
8.6 |
Slew rate definitions for Differential Input Signals ................................................................................................... |
16 |
|
9. AC & DC Output Measurement Levels ......................................................................................................................... |
|
17 |
|
9.1 |
Single-ended AC & DC Output Levels..................................................................................................................... |
|
17 |
9.2 |
Differential AC & DC Output Levels......................................................................................................................... |
|
17 |
9.3 |
Single-ended Output Slew Rate .............................................................................................................................. |
|
17 |
9.4 |
Differential Output Slew Rate .................................................................................................................................. |
|
18 |
9.5 |
Reference Load for AC Timing and Output Slew Rate ............................................................................................ |
18 |
|
9.6 |
Overshoot/Undershoot Specification ....................................................................................................................... |
|
19 |
9.6.1. Address and Control Overshoot and Undershoot specifications...................................................................... |
19 |
||
9.6.2. Clock, Data, Strobe and Mask Overshoot and Undershoot Specifications ...................................................... |
19 |
||
9.7 |
34ohm Output Driver DC Electrical Characteristics................................................................................................. |
20 |
|
9.7.1. Output Drive Temperature and Voltage Sensitivity .......................................................................................... |
21 |
||
9.8 |
On-Die Termination (ODT) Levels and I-V Characteristics ..................................................................................... |
21 |
|
9.8.1. ODT DC Electrical Characteristics ................................................................................................................... |
|
22 |
|
9.8.2. ODT Temperature and Voltage sensitivity ...................................................................................................... |
23 |
||
9.9 |
ODT Timing Definitions ........................................................................................................................................... |
|
24 |
9.9.1. Test Load for ODT Timings.............................................................................................................................. |
|
24 |
|
9.9.2. ODT Timing Definitions .................................................................................................................................... |
|
24 |
|
10. IDD Current Measure Method..................................................................................................................................... |
|
27 |
|
10.1 IDD Measurement Conditions ............................................................................................................................... |
|
27 |
|
11. 1Gb DDR3 SDRAM G-die IDD Specification Table .................................................................................................... |
36 |
||
12. Input/Output Capacitance ........................................................................................................................................... |
|
37 |
|
13. Electrical Characteristics and AC timing for DDR3-800 to DDR3-1866...................................................................... |
38 |
||
13.1 Clock Specification ................................................................................................................................................ |
|
38 |
|
13.1.1. Definition for tCK(avg).................................................................................................................................... |
|
38 |
|
13.1.2. Definition for tCK(abs).................................................................................................................................... |
|
38 |
|
13.1.3. Definition for tCH(avg) and tCL(avg).............................................................................................................. |
|
38 |
|
13.1.4. Definition for note for tJIT(per), tJIT(per, Ick) ................................................................................................. |
38 |
||
13.1.5. Definition for tJIT(cc), tJIT(cc, Ick) ................................................................................................................. |
|
38 |
|
13.1.6. Definition for tERR(nper)................................................................................................................................ |
|
38 |
|
13.2 Refresh Parameters by Device Density................................................................................................................. |
|
39 |
|
13.3 Speed Bins and CL, tRCD, tRP, tRC and tRAS for corresponding Bin ................................................................. |
39 |
||
13.3.1. Speed Bin Table Notes .................................................................................................................................. |
|
43 |
- 3 -
|
|
|
Rev. 1.01 |
|
|
”YNN MacshbM· |
|
K4B1G0846G |
datasheet |
DDR3 SDRAM |
|
K4B1G0446G |
|
|
|
14. Timing Parameters by Speed Grade .......................................................................................................................... |
|
44 |
|
14.1 |
Jitter Notes ............................................................................................................................................................ |
|
50 |
14.2 |
Timing Parameter Notes........................................................................................................................................ |
|
51 |
14.3 |
Address/Command Setup, Hold and Derating : .................................................................................................... |
52 |
|
14.4 |
Data Setup, Hold and Slew Rate Derating : .......................................................................................................... |
|
59 |
- 4 -
|
|
|
|
|
|
|
|
Rev. 1.01 |
|
|
K4B1G0846G |
|
|
”YNN MacshbM· |
|||||
|
|
|
datasheet |
DDR3 SDRAM |
|||||
|
K4B1G0446G |
|
|
|
|
|
|
|
|
|
1. Ordering Information |
|
|
|
|
|
|||
|
[ Table 1 ] Samsung 1Gb DDR3 G-die ordering information table |
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
Organization |
|
DDR3-1066 (7-7-7) |
|
DDR3-1333 (9-9-9)4 |
DDR3-1600 (11-11-11)3 |
DDR3-1866 (13-13-13)2 |
Package |
|
|
256Mx4 |
|
K4B1G0446G-BCF8 |
|
K4B1G0446G-BCH9 |
K4B1G0446G-BCK0 |
K4B1G0446G-BCMA |
78 FBGA |
|
|
|
|
|
|
|
|
|
|
|
|
128Mx8 |
|
K4B1G0846G-BCF8 |
|
K4B1G0846G-BCH9 |
K4B1G0846G-BCK0 |
K4B1G0846G-BCMA |
78 FBGA |
|
|
|
|
|
|
|
|
|
|
|
|
NOTE : |
|
|
|
|
|
|
|
1.Speed bin is in order of CL-tRCD-tRP.
2.Backward compatible to DDR3-1600(11-11-11), DDR3-1333(9-9-9), DDR3-1066(7-7-7)
3.Backward compatible to DDR3-1333(9-9-9), DDR3-1066(7-7-7)
4.Backward compatible to DDR3-1066(7-7-7)
[ Table 2 ] 1Gb DDR3 G-die Speed bins
Speed |
DDR3-800 |
DDR3-1066 |
DDR3-1333 |
DDR3-1600 |
DDR3-1866 |
Unit |
|
6-6-6 |
7-7-7 |
9-9-9 |
11-11-11 |
13-13-13 |
|||
|
|
||||||
tCK(min) |
2.5 |
1.875 |
1.5 |
1.25 |
1.07 |
ns |
|
|
|
|
|
|
|
|
|
CAS Latency |
6 |
7 |
9 |
11 |
13 |
nCK |
|
|
|
|
|
|
|
|
|
tRCD(min) |
15 |
13.125 |
13.5 |
13.75 |
13.91 |
ns |
|
|
|
|
|
|
|
|
|
tRP(min) |
15 |
13.125 |
13.5 |
13.75 |
13.91 |
ns |
|
|
|
|
|
|
|
|
|
tRAS(min) |
37.5 |
37.5 |
36 |
35 |
34 |
ns |
|
|
|
|
|
|
|
|
|
tRC(min) |
52.5 |
50.625 |
49.5 |
48.75 |
47.91 |
ns |
|
|
|
|
|
|
|
|
•JEDEC standard 1.5V ± 0.075V Power Supply
•VDDQ = 1.5V ± 0.075V
•400 MHz fCK for 800Mb/sec/pin, 533MHz fCK for 1066Mb/sec/pin, 667MHz fCK for 1333Mb/sec/pin, 800MHz fCK for 1600Mb/sec/pin 900MHz fCK for 1866Mb/sec/pin
•8 Banks
•Programmable CAS Latency(posted CAS): 5,6,7,8,9,10,11,13
•Programmable Additive Latency: 0, CL-2 or CL-1 clock
• Programmable CAS Write Latency (CWL) = 5 (DDR3-800), 6 (DDR3-1066), 7 (DDR3-1333), 8 (DDR3-1600) and 9 (DDR3-1866)
•8-bit pre-fetch
•Burst Length: 8 (Interleave without any limit, sequential with starting address “000” only), 4 with tCCD = 4 which does not allow seamless read or write [either On the fly using A12 or MRS]
•Bi-directional Differential Data-Strobe
•Internal(self) calibration : Internal self calibration through ZQ pin (RZQ : 240 ohm ± 1%)
•On Die Termination using ODT pin
•Average Refresh Period 7.8us at lower than TCASE 85°C, 3.9us at 85°C < TCASE < 95 °C
•Asynchronous Reset
•Package : 78 balls FBGA - x4/x8
•All of Lead-Free products are compliant for RoHS
•All of products are Halogen-free
The 1Gb DDR3 SDRAM G-die is organized as a 32Mbit x 4 I/Os x 8banks, 16Mbit x 8 I/Os x 8banks device. This synchronous device achieves high speed double-data-rate transfer rates of up to 1866Mb/sec/pin (DDR31866) for general applications.
The chip is designed to comply with the following key DDR3 SDRAM features such as posted CAS, Programmable CWL, Internal (Self) Calibration, On Die Termination using ODT pin and Asynchronous Reset .
All of the control and address inputs are synchronized with a pair of externally supplied differential clocks. Inputs are latched at the crosspoint of differential clocks (CK rising and CK falling). All I/Os are synchronized with a pair of bidirectional strobes (DQS and DQS) in a source synchronous fashion. The address bus is used to convey row, column, and bank address information in a RAS/CAS multiplexing style. The DDR3 device operates with a single 1.5V ± 0.075V power supply and 1.5V ± 0.075V VDDQ.
The 1Gb DDR3 G-die device is available in 78ball FBGAs(x4/x8).
NOTE : 1. This data sheet is an abstract of full DDR3 specification and does not cover the common features which are described in “DDR3 SDRAM Device Operation & Timing Diagram”.
2. The functionality described and the timing specifications included in this data sheet are for the DLL Enabled mode of operation.
- 5 -
|
|
Rev. 1.01 |
K4B1G0846G |
”YNN MacshbM· |
|
datasheet |
DDR3 SDRAM |
|
K4B1G0446G |
|
|
|
|
1 |
2 |
|
|
3 |
|
|
|
|
4 |
5 |
6 |
7 |
|
|
|
8 |
9 |
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
A |
|
VSS |
|
VDD |
|
|
NC |
|
|
|
|
NC |
VSS |
VDD |
|
A |
||||||||||
B |
|
VSS |
|
VSSQ |
|
DQ0 |
|
|
|
DM |
VSSQ |
VDDQ |
|
B |
||||||||||||
C |
|
VDDQ |
|
DQ2 |
|
DQS |
|
|
|
DQ1 |
DQ3 |
VSSQ |
|
C |
||||||||||||
D |
|
VSSQ |
|
NC |
|
DQS |
|
|
|
|
VDD |
VSS |
VSSQ |
|
D |
|||||||||||
E |
|
VREFDQ |
|
VDDQ |
|
|
NC |
|
|
|
|
NC |
NC |
VDDQ |
|
E |
||||||||||
F |
|
NC |
|
VSS |
|
RAS |
|
|
|
|
|
|
CK |
VSS |
NC |
|
F |
|||||||||
G |
|
ODT |
|
VDD |
|
CAS |
|
|
|
|
|
CK |
|
|
VDD |
CKE |
|
G |
||||||||
H |
|
NC |
|
|
CS |
|
|
|
|
WE |
|
|
|
|
A10/AP |
ZQ |
NC |
|
H |
|||||||
J |
|
VSS |
|
BA0 |
|
BA2 |
|
|
|
|
NC |
VREFCA |
VSS |
|
J |
|||||||||||
K |
|
VDD |
|
|
A3 |
|
|
A0 |
|
|
|
|
|
|
BA1 |
VDD |
|
K |
||||||||
|
|
|
|
|
|
|
A12/BC |
|||||||||||||||||||
L |
|
VSS |
|
|
A5 |
|
|
A2 |
|
|
|
|
A1 |
A4 |
VSS |
|
L |
|||||||||
M |
|
VDD |
|
|
A7 |
|
|
A9 |
|
|
|
A11 |
A6 |
VDD |
|
M |
||||||||||
N |
|
VSS |
|
RESET |
|
|
A13 |
|
|
|
|
NC |
A8 |
VSS |
|
N |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
Ball Locations (x4) |
A |
|||
|
|
|
|
B |
|
|
|
|
C |
|
|
|
Populated ball |
D |
|
|
|
Ball not populated |
E |
|
|
|
|
F |
|
|
|
|
G |
Top view |
H |
|||
J |
||||
(See the balls through the package) |
K |
|||
|
|
|
|
|
|
|
|
|
L |
|
|
|
|
M |
|
|
|
|
N |
- 6 -
|
|
Rev. 1.01 |
K4B1G0846G |
”YNN MacshbM· |
|
datasheet |
DDR3 SDRAM |
|
K4B1G0446G |
|
|
|
|
1 |
2 |
|
|
3 |
|
|
|
|
4 |
5 |
6 |
7 |
|
|
|
|
8 |
9 |
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
A |
|
VSS |
|
VDD |
|
|
NC |
|
|
|
|
|
|
|
|
|
VSS |
VDD |
|
|
|||||||
|
|
|
NU/TDQS |
|
|
A |
|||||||||||||||||||||
B |
|
VSS |
|
VSSQ |
|
DQ0 |
|
|
|
DM/TDQS |
VSSQ |
VDDQ |
|
B |
|||||||||||||
C |
|
VDDQ |
|
DQ2 |
|
DQS |
|
|
|
DQ1 |
DQ3 |
VSSQ |
|
C |
|||||||||||||
D |
|
VSSQ |
|
DQ6 |
|
DQS |
|
|
|
|
VDD |
VSS |
VSSQ |
|
D |
||||||||||||
E |
|
VREFDQ |
|
VDDQ |
|
DQ4 |
|
|
|
DQ7 |
DQ5 |
VDDQ |
|
E |
|||||||||||||
F |
|
NC |
|
VSS |
|
RAS |
|
|
|
|
|
|
CK |
VSS |
NC |
|
F |
||||||||||
G |
|
ODT |
|
VDD |
|
CAS |
|
|
|
|
|
CK |
|
|
VDD |
CKE |
|
G |
|||||||||
H |
|
NC |
|
|
CS |
|
|
|
|
WE |
|
|
|
|
A10/AP |
ZQ |
NC |
|
H |
||||||||
J |
|
VSS |
|
BA0 |
|
BA2 |
|
|
|
|
NC |
VREFCA |
VSS |
|
J |
||||||||||||
K |
|
VDD |
|
|
A3 |
|
|
A0 |
|
|
|
|
|
|
BA1 |
VDD |
|
K |
|||||||||
|
|
|
|
|
|
|
A12/BC |
||||||||||||||||||||
L |
|
VSS |
|
|
A5 |
|
|
A2 |
|
|
|
|
A1 |
A4 |
VSS |
|
L |
||||||||||
M |
|
VDD |
|
|
A7 |
|
|
A9 |
|
|
|
A11 |
A6 |
VDD |
|
M |
|||||||||||
N |
|
VSS |
|
RESET |
|
|
A13 |
|
|
|
|
NC |
A8 |
VSS |
|
N |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
Ball Locations (x8) |
A |
|||
|
|
|
|
|
|
|
|
|
B |
|
|
|
|
C |
|
|
|
Populated ball |
D |
|
|
|
Ball not populated |
E |
|
|
|
|
F |
|
|
|
|
G |
Top view |
H |
|||
J |
||||
(See the balls through the package) |
K |
|||
|
|
|
|
|
|
|
|
|
L |
|
|
|
|
M |
|
|
|
|
N |
- 7 -
|
|
Rev. 1.01 |
K4B1G0846G |
”YNN MacshbM· |
|
datasheet |
DDR3 SDRAM |
|
K4B1G0446G |
|
|
Units : Millimeters
|
|
|
|
7.50 ± 0.10 |
|
|
A |
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
(Datum A) |
|
0.80 |
|
1.60 |
|
|
3.20 |
|
#A1 INDEX MARK |
||||
|
|
|
|
|
|
|
|
||||||
|
|
9 |
8 |
7 |
6 |
5 |
4 |
3 |
2 |
1 |
|
|
B |
|
A |
|
|
|
|
|
|
|
|
|
|
|
|
|
B |
|
|
|
|
|
|
|
|
|
|
|
|
(Datum B) |
C |
|
|
|
|
|
|
|
|
|
4.80 |
|
|
D |
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
0.80 |
= 9.60 |
|
||
|
E |
|
|
|
|
|
|
|
|
0.10 |
|||
|
F |
|
|
|
|
|
|
|
|
||||
|
G |
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
0.80 x 12 |
11.00 ± |
|
|
H |
|
|
|
|
|
|
|
|
|
|
||
|
J |
|
|
|
|
|
|
|
|
|
|
||
|
K |
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
0.80 |
|
|
|
|
|
L |
|
|
|
|
|
|
|
|
|
|
|
|
|
M |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
N |
|
|
|
|
|
|
|
|
|
|
|
|
78 - 0.48 Solder ball |
|
|
|
|
(0.30) |
|
|
|
|
||||
(Post Reflow 0.50 ± 0.05) |
|
|
|
|
|
|
MOLDING AREA |
|
|||||
0.2 M |
A |
B |
|
|
(0.60) |
|
|
|
|
|
|
BOTTOM VIEW
0.10MAX
#A1 |
7.50 ± 0.10 |
|
11.00 ± 0.10 |
|
0.37 ± 0.05 |
|
1.10 ± 0.10 |
TOP VIEW
- 8 -
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Rev. 1.01 |
|||||
|
K4B1G0846G |
|
|
|
|
|
|
|
|
|
|
|
|
”YNN MacshbM· |
||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
datasheet |
DDR3 SDRAM |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
K4B1G0446G |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||
|
4. Input/Output Functional Description |
|
|
|
|
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
[ Table 3 ] Input/Output function description |
|
|
|
|
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Symbol |
|
Type |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Function |
|
|
|
|
|
|
|
|
|
||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Clock: CK and |
|
|
are differential clock inputs. All address and control input signals are sampled on the crossing of |
|
|||||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Input |
CK |
||||||||||||||||||||||||||||||||||||||||||||||
|
|
|
CK, CK |
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||
|
|
the positive edge of CK and negative edge of CK. Output (read) data is referenced to the crossings of CK and CK |
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Clock Enable: CKE HIGH activates, and CKE Low deactivates, internal clock signals and device input buffers and |
|
||||||||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
output drivers. Taking CKE Low provides Precharge Power-Down and Self Refresh operation (all banks idle), or |
|
||||||||||||||||||||||||||||||||||||||||||||
|
|
|
CKE |
|
Input |
|
Active Power-Down (Row Active in any bank). CKE is asynchronous for self refresh exit. After VREFCA has become |
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
stable during the power on and initialization sequence, it must be maintained during all operations (including Self- |
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Refresh). CKE must be maintained high throughout read and write accesses. Input buffers, excluding CK, |
CK, |
ODT |
|
||||||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
and CKE are disabled during power-down. Input buffers, excluding CKE, are disabled during Self -Refresh. |
|
||||||||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Chip Select: All commands are masked when |
|
|
is registered HIGH. |
|
provides for external Rank selection on |
|
|||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Input |
CS |
CS |
|||||||||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
CS |
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||
|
|
|
|
|
|
systems with multiple Ranks. CS is considered part of the command code. |
|
|
|
|
|
|
|
|
|
|||||||||||||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
On Die Termination: ODT (registered HIGH) enables termination resistance internal to the DDR3 SDRAM. When |
|
|||||||||||||||||||||||||||||||||||||||||||||
|
|
|
ODT |
|
Input |
enabled, ODT is only applied to each DQ, DQS, DQS and DM/TDQS, NU/TDQS (When TDQS is enabled via Mode |
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
Register A11=1 in MR1) signal for x8 configurations. The ODT pin will be ignored if the Mode Register (MR1) is pro- |
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
grammed to disable ODT. |
|
|
|
|
|
|
|
|
|
||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Input |
|
Command Inputs: |
|
|
|
|
and |
|
|
|
(along with |
|
|
|
define the command being entered. |
|
||||||||||||||||||||||||||||||||
|
|
RAS, |
CAS, |
WE |
RAS, |
CAS |
WE |
CS) |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||
|
|
|
|
DM |
|
|
|
Input Data Mask: DM is an input mask signal for write data. Input data is masked when DM is sampled HIGH coinci- |
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
Input |
|
dent with that input data during a Write access. DM is sampled on both edges of DQS. For x8 device, the function of |
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
(DMU), (DML) |
|
|
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||
|
|
|
|
DM or TDQS/TDQS is enabled by Mode Register A11 setting in MR1. |
|
|
|
|
|
|
|
|
|
|||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Bank Address Inputs: BA0 - BA2 define to which bank an Active, Read, Write or Precharge command is being |
|
||||||||||||||||||||||||||||||||||||||||||||
|
|
BA0 - BA2 |
|
Input |
|
applied. Bank address also determines if the mode register or extended mode register is to be accessed during a |
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
MRS cycle. |
|
|
|
|
|
|
|
|
|
||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Address Inputs: Provided the row address for Active commands and the column address for Read/Write commands |
|
||||||||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
have additional functions, |
|
||||||||||||||||||||
|
|
A0 - A13 |
|
Input |
|
to select one location out of the memory array in the respective bank. (A10/AP and A12/BC |
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
|
|
see below) |
|
|
|
|
|
|
|
|
|
|||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
The address inputs also provide the op-code during Mode Register Set commands. |
|
|
|
|
|
|
|
|
|
||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Autoprecharge: A10 is sampled during Read/Write commands to determine whether Autoprecharge should be per- |
|
||||||||||||||||||||||||||||||||||||||||||||
|
|
A10 / AP |
|
Input |
|
formed to the accessed bank after the Read/Write operation. (HIGH:Autoprecharge; LOW: No Autoprecharge) |
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
|
|
A10 is sampled during a Precharge command to determine whether the Precharge applies to one bank (A10 LOW) or |
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
all banks (A10 HIGH). if only one bank is to be precharged, the bank is selected by bank addresses. |
|
||||||||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Burst Chop:A12 is sampled during Read and Write commands to determine if burst chop(on-the-fly) will be per- |
|
||||||||||||||||||||||||||||||||||||||||||||
|
|
A12 / BC |
|
Input |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
|
|
formed. (HIGH : no burst chop, LOW : burst chopped). See command truth table for details |
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Active Low Asynchronous Reset: Reset is active when |
|
|
|
is LOW, and inactive when |
|
is HIGH. |
|
||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
RESET |
RESET |
|||||||||||||||||||||||||||||||||||||||||||||
|
|
|
RESET |
|
|
|
|
Input |
|
RESET |
must be HIGH during normal operation. |
RESET |
is a CMOS rail to rail signal with DC high and low at 80% and |
|
||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
20% of VDD, i.e. 1.20V for DC high and 0.30V for DC low. |
|
|
|
|
|
|
|
|
|
||||||||||||||||||||||||||||||||||||
|
|
|
|
DQ |
|
Input/Output |
|
Data Input/ Output: Bi-directional data bus. |
|
|
|
|
|
|
|
|
|
|||||||||||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Data Strobe: Output with read data, input with write data. Edge-aligned with read data, centered in write data. For the |
|
||||||||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
x16, DQSL: corresponds to the data on DQL0-DQL7; DQSU corresponds to the data on DQU0-DQU7. The data |
|
||||||||||||||||||||||||||||||||||||||||||||
|
|
DQS, |
(DQS) |
|
|
|
Input/Output |
|
strobe DQS, DQSL and DQSU are paired with differential signals |
DQS, |
|
DQSL |
and |
DQSU, |
respectively, to provide dif- |
|
||||||||||||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
ferential pair signaling to the system during reads and writes. DDR3 SDRAM supports differential data strobe only and |
|
||||||||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
does not support single-ended. |
|
|
|
|
|
|
|
|
|
||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
is applicable for X8 DRAMs only. When enabled via Mode Register A11=1 in |
|
||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Termination Data Strobe: TDQS/TDQS |
|||||||||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
MR1, DRAM will enable the same termination resistance function on TDQS/TDQS that is applied to DQS/DQS. When |
|
||||||||||||||||||||||||||||||||||||||||||||
|
TDQS, (TDQS) |
|
Output |
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
|
disabled via mode register A11=0 in MR1, DM/TDQS will provide the data mask function and TDQS is not used. x4/ |
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
x16 DRAMs must disable the TDQS function via mode register A11=0 in MR1. |
|
|
|
|
|
|
|
|
|
||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||||||||||||||||||||||||||||||||||
|
|
|
|
NC |
|
|
|
No Connect: No internal electrical connection is present. |
|
|
|
|
|
|
|
|
|
|||||||||||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||||||
|
|
|
VDDQ |
|
Supply |
|
DQ Power Supply: 1.5V +/- 0.075V |
|
|
|
|
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||||||
|
|
|
VSSQ |
|
Supply |
|
DQ Ground |
|
|
|
|
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||||||
|
|
|
|
VDD |
|
Supply |
|
Power Supply: 1.5V +/- 0.075V |
|
|
|
|
|
|
|
|
|
|||||||||||||||||||||||||||||||||||||||||||||||
|
|
|
|
VSS |
|
Supply |
|
Ground |
|
|
|
|
|
|
|
|
|
|||||||||||||||||||||||||||||||||||||||||||||||
|
|
VREFDQ |
|
Supply |
|
Reference voltage for DQ |
|
|
|
|
|
|
|
|
|
|||||||||||||||||||||||||||||||||||||||||||||||||
|
|
VREFCA |
|
Supply |
|
Reference voltage for CA |
|
|
|
|
|
|
|
|
|
|||||||||||||||||||||||||||||||||||||||||||||||||
|
|
|
|
ZQ |
|
Supply |
|
Reference Pin for ZQ calibration |
|
|
|
|
|
|
|
|
|
|||||||||||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
NOTE : Input only pins (BA0-BA2, A0-A13, |
|
|
|
|
|
|
|
|
|
|
CKE, ODT and |
|
|
|
do not supply termination. |
|
|||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
RAS, |
CAS, |
WE, |
CS, |
RESET) |
|||||||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
- 9 - |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Rev. 1.01 |
||
|
K4B1G0846G |
|
|
|
”YNN MacshbM· |
|||||||||
|
datasheet |
DDR3 SDRAM |
||||||||||||
|
K4B1G0446G |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
5. DDR3 SDRAM Addressing |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1Gb |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Configuration |
|
256Mb x 4 |
128Mb x 8 |
64Mb x 16 |
|
|
|||||||
|
# of Bank |
|
8 |
|
|
8 |
|
8 |
|
|
|
|||
|
|
|
|
|
|
|
|
|||||||
|
Bank Address |
|
BA0 - BA2 |
BA0 - BA2 |
BA0 - BA2 |
|
|
|||||||
|
|
|
|
|
|
|
|
|||||||
|
Auto precharge |
|
A10/AP |
A10/AP |
A10/AP |
|
|
|||||||
|
|
|
|
|
|
|
|
|||||||
|
Row Address |
|
A0 - A13 |
A0 - A13 |
A0 - A12 |
|
|
|||||||
|
|
|
|
|
|
|
|
|||||||
|
Column Address |
|
A0 - A9,A11 |
A0 - A9 |
A0 - A9 |
|
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
BC switch on the fly |
|
A12 |
|
|
A12 |
|
|
A12 |
|
|
|
|
|
|
/BC |
/BC |
/BC |
|||||||||||
|
|
|
|
|
|
|
|
|||||||
|
Page size *1 |
|
1 KB |
1 KB |
2 KB |
|
|
|||||||
|
2Gb |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||
|
Configuration |
|
512Mb x 4 |
256Mb x 8 |
128Mb x 16 |
|
|
|||||||
|
# of Bank |
|
8 |
|
|
8 |
|
8 |
|
|
|
|||
|
|
|
|
|
|
|
|
|||||||
|
Bank Address |
|
BA0 - BA2 |
BA0 - BA2 |
BA0 - BA2 |
|
|
|||||||
|
|
|
|
|
|
|
|
|||||||
|
Auto precharge |
|
A10/AP |
A10/AP |
A10/AP |
|
|
|||||||
|
|
|
|
|
|
|
|
|||||||
|
Row Address |
|
A0 - A14 |
A0 - A14 |
A0 - A13 |
|
|
|||||||
|
|
|
|
|
|
|
|
|||||||
|
Column Address |
|
A0 - A9,A11 |
A0 - A9 |
A0 - A9 |
|
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
BC switch on the fly |
|
A12 |
|
|
A12 |
|
|
A12 |
|
|
|
|
|
|
/BC |
/BC |
/BC |
|||||||||||
|
Page size *1 |
|
1 KB |
1 KB |
2 KB |
|
|
|||||||
|
4Gb |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||
|
Configuration |
|
1Gb x 4 |
512Mb x 8 |
256Mb x 16 |
|
|
|||||||
|
# of Bank |
|
8 |
|
|
8 |
|
8 |
|
|
|
|||
|
|
|
|
|
|
|
|
|||||||
|
Bank Address |
|
BA0 - BA2 |
BA0 - BA2 |
BA0 - BA2 |
|
|
|||||||
|
|
|
|
|
|
|
|
|||||||
|
Auto precharge |
|
A10/AP |
A10/AP |
A10/AP |
|
|
|||||||
|
|
|
|
|
|
|
|
|||||||
|
Row Address |
|
A0 - A15 |
A0 - A15 |
A0 - A14 |
|
|
|||||||
|
|
|
|
|
|
|
|
|||||||
|
Column Address |
|
A0 - A9,A11 |
A0 - A9 |
A0 - A9 |
|
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
BC switch on the fly |
|
A12 |
|
|
A12 |
|
|
A12 |
|
|
|
|
|
|
/BC |
/BC |
/BC |
|||||||||||
|
|
|
|
|
|
|
|
|||||||
|
Page size *1 |
|
1 KB |
1 KB |
2 KB |
|
|
|||||||
|
8Gb |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||
|
Configuration |
|
2Gb x 4 |
1Gb x 8 |
512Mb x 16 |
|
|
|||||||
|
# of Bank |
|
8 |
|
|
8 |
|
8 |
|
|
|
|||
|
|
|
|
|
|
|
||||||||
|
Bank Address |
|
BA0 - BA2 |
BA0 - BA2 |
BA0 - BA2 |
|
|
|||||||
|
|
|
|
|
|
|
||||||||
|
Auto precharge |
|
A10/AP |
A10/AP |
A10/AP |
|
|
|||||||
|
|
|
|
|
|
|
||||||||
|
Row Address |
|
A0 - A15 |
A0 - A15 |
A0 - A15 |
|
|
|||||||
|
|
|
|
|
|
|
||||||||
|
Column Address |
|
A0 - A9,A11,A13 |
A0 - A9,A11 |
A0 - A9 |
|
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
BC switch on the fly |
|
A12 |
|
|
|
A12 |
|
|
A12 |
|
|
|
|
|
/BC |
/BC |
/BC |
|||||||||||
|
Page size *1 |
|
2 KB |
2 KB |
2 KB |
|
|
NOTE 1 : Page size is the number of bytes of data delivered from the array to the internal sense amplifiers when an ACTIVE command is registered. Page size is per bank, calculated as follows: page size = 2 COLBITS * ORG÷8
where, COLBITS = the number of column address bits, ORG = the number of I/O (DQ) bits
- 10 -
|
|
|
|
|
|
|
|
Rev. 1.01 |
|
|
K4B1G0846G |
|
|
”YNN MacshbM· |
|||||
|
|
datasheet |
DDR3 SDRAM |
||||||
|
K4B1G0446G |
|
|
|
|
|
|
|
|
|
6. Absolute Maximum Ratings |
|
|
|
|
|
|
||
|
6.1 Absolute Maximum DC Ratings |
|
|
|
|
|
|
||
|
[ Table 4 ] Absolute Maximum DC Ratings |
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
Symbol |
|
Parameter |
|
Rating |
|
Units |
NOTE |
|
|
VDD |
|
Voltage on VDD pin relative to Vss |
|
-0.4 V ~ 1.975 V |
|
V |
1,3 |
|
|
VDDQ |
|
Voltage on VDDQ pin relative to Vss |
|
-0.4 V ~ 1.975 V |
|
V |
1,3 |
|
|
VIN, VOUT |
|
Voltage on any pin relative to Vss |
|
-0.4 V ~ 1.975 V |
|
V |
1 |
|
|
TSTG |
|
Storage Temperature |
|
-55 to +100 |
|
°C |
1, 2 |
|
NOTE :
1.Stresses greater than those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress rating only and functional operation of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods may affect reliability.
2.Storage Temperature is the case surface temperature on the center/top side of the DRAM. For the measurement conditions, please refer to JESD51-2 standard.
3.VDD and VDDQ must be within 300mV of each other at all times; and VREF must be not greater than 0.6 x VDDQ, When VDD and VDDQ are less than 500mV; VREF may be equal to or less than 300mV.
[ Table 5 ] Temperature Range
Symbol |
Parameter |
rating |
Unit |
NOTE |
TOPER |
Operating Temperature Range |
0 to 95 |
°C |
1, 2, 3 |
NOTE :
1.Operating Temperature TOPER is the case surface temperature on the center/top side of the DRAM. For measurement conditions, please refer to the JEDEC document JESD51-2.
2.The Normal Temperature Range specifies the temperatures where all DRAM specifications will be supported. During operation, the DRAM case temperature must be maintained between 0-85°C under all operating conditions
3.Some applications require operation of the Extended Temperature Range between 85°C and 95°C case temperature. Full specifications are guaranteed in this range, but the following additional conditions apply:
a)Refresh commands must be doubled in frequency, therefore reducing the refresh interval tREFI to 3.9us.
b)If Self-Refresh operation is required in the Extended Temperature Range, then it is mandatory to either use the Manual Self-Refresh mode with Extended Temperature Range capability (MR2 A6 = 0b and MR2 A7 = 1b), in this case IDD6 current can be increased around 10~20% than normal Temperature range.
[ Table 6 ] Recommended DC Operating Conditions
Symbol |
Parameter |
|
Rating |
|
Units |
NOTE |
|
Min. |
Typ. |
Max. |
|||||
|
|
|
|
||||
VDD |
Supply Voltage |
1.425 |
1.5 |
1.575 |
V |
1,2 |
|
VDDQ |
Supply Voltage for Output |
1.425 |
1.5 |
1.575 |
V |
1,2 |
NOTE :
1.Under all conditions VDDQ must be less than or equal to VDD.
2.VDDQ tracks with VDD. AC parameters are measured with VDD and VDDQ tied together.
- 11 -
|
|
|
|
|
|
|
|
|
|
Rev. 1.01 |
||
|
K4B1G0846G |
|
”YNN MacshbM· |
|||||||||
|
datasheet |
|
|
DDR3 SDRAM |
||||||||
|
K4B1G0446G |
|
|
|
|
|
|
|
|
|
|
|
|
8. AC & DC Input Measurement Levels |
|
|
|
|
|
|
|
|
|||
|
8.1 AC & DC Logic input levels for single-ended signals |
|
|
|
|
|
|
|||||
|
[ Table 7 ] Single-ended AC & DC input levels for Command and Address |
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Symbol |
Parameter |
DDR3-800/1066/1333/1600 |
|
|
DDR3-1866 |
Unit |
NOTE |
|
|||
|
Min. |
|
Max. |
|
Min. |
|
Max. |
|
||||
|
|
|
|
|
|
|
|
|
||||
|
VIH.CA(DC100) |
DC input logic high |
VREF + 100 |
|
VDD |
|
VREF + 100 |
|
VDD |
mV |
1,5 |
|
|
VIL.CA(DC100) |
DC input logic low |
VSS |
|
VREF - 100 |
|
VSS |
|
VREF - 100 |
mV |
1,6 |
|
|
VIH.CA(AC175) |
AC input logic high |
VREF + 175 |
|
Note 2 |
|
- |
|
- |
mV |
1,2,7 |
|
|
VIL.CA(AC175) |
AC input logic low |
Note 2 |
|
VREF - 175 |
|
- |
|
- |
mV |
1,2,8 |
|
|
VIH.CA(AC150) |
AC input logic high |
VREF+150 |
|
Note 2 |
|
- |
|
- |
mV |
1,2,7 |
|
|
VIL.CA(AC150) |
AC input logic low |
Note 2 |
|
VREF-150 |
|
- |
|
- |
mV |
1,2,8 |
|
|
VIH.CA(AC135) |
AC input logic high |
- |
|
- |
|
VREF + 135 |
|
Note 2 |
mV |
1,2,7 |
|
|
VIL.CA(AC135) |
AC input logic low |
- |
|
- |
|
Note 2 |
|
VREF - 135 |
mV |
1,2,8 |
|
|
VIH.CA(AC125) |
AC input logic high |
- |
|
- |
|
VREF+125 |
|
Note 2 |
mV |
1,2,7 |
|
|
VIL.CA(AC125) |
AC input logic low |
- |
|
- |
|
Note 2 |
|
VREF-125 |
mV |
1,2,8 |
|
|
VREFCA(DC) |
Reference Voltage for |
0.49*VDD |
|
0.51*VDD |
|
0.49*VDD |
|
0.51*VDD |
V |
3,4 |
|
|
ADD, CMD inputs |
|
|
|
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
NOTE : |
|
|
|
|
|
|
|
|
|
|
|
1.For input only pins except RESET, VREF = VREFCA(DC)
2.See ’Overshoot/Undershoot Specification’ on page 19.
3.The AC peak noise on VREF may not allow VREF to deviate from VREF(DC) by more than ± 1% VDD (for reference : approx. ± 15mV)
4.For reference : approx. VDD/2 ± 15mV
5.VIH(dc) is used as a simplified symbol for VIH.CA(DC100)
6.VIL(dc) is used as a simplified symbol for VIL.CA(DC100)
7.VIH(ac) is used as a simplified symbol for VIH.CA(AC175) and VIH.CA(AC150); VIH.CA(AC175) value is used when VREF + 175mV is referenced and VIH.CA(AC150) value is used when VREF + 150mV is referenced.
8.VIL(ac) is used as a simplified symbol for VIL.CA(AC175) and VIL.CA(AC150); VIL.CA(AC175) value is used when VREF - 175mV is referenced and VIL.CA(AC150) value is used when VREF - 150mV is referenced.
[ Table 8 ] Single-ended AC & DC input levels for DQ and DM
Symbol |
Parameter |
DDR3-800/1066 |
DDR3-1333/1600 |
DDR3-1866 |
Unit |
NOTE |
||||
Min. |
Max. |
Min. |
Max. |
Min. |
Max. |
|||||
|
|
|
|
|||||||
VIH.DQ(DC100) |
DC input logic high |
VREF + 100 |
VDD |
VREF + 100 |
VDD |
VREF + 100 |
VDD |
mV |
1,5 |
|
VIL.DQ(DC100) |
DC input logic low |
VSS |
VREF - 100 |
VSS |
VREF - 100 |
VSS |
VREF - 100 |
mV |
1,6 |
|
VIH.DQ(AC175) |
AC input logic high |
VREF + 175 |
NOTE 2 |
- |
- |
- |
- |
mV |
1,2,7 |
|
VIL.DQ(AC175) |
AC input logic low |
NOTE 2 |
VREF - 175 |
- |
- |
- |
- |
mV |
1,2,8 |
|
VIH.DQ(AC150) |
AC input logic high |
VREF + 150 |
NOTE 2 |
VREF + 150 |
NOTE 2 |
- |
- |
mV |
1,2,7 |
|
VIL.DQ(AC150) |
AC input logic low |
NOTE 2 |
VREF - 150 |
NOTE 2 |
VREF - 150 |
- |
- |
mV |
1,2,8 |
|
VIH.DQ(AC135) |
AC input logic high |
- |
- |
- |
- |
VREF + 135 |
NOTE 2 |
mV |
1,2,7 |
|
VIL.DQ(AC135) |
AC input logic low |
- |
- |
- |
- |
NOTE 2 |
VREF - 135 |
mV |
1,2,8 |
|
VREFDQ(DC) |
Reference Voltage for DQ, |
0.49*VDD |
0.51*VDD |
0.49*VDD |
0.51*VDD |
0.49*VDD |
0.51*VDD |
V |
3,4 |
|
DM inputs |
||||||||||
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
NOTE :
1.For input only pins except RESET, VREF = VREFDQ(DC)
2.See ’Overshoot/Undershoot Specification’ on page 19.
3.The AC peak noise on VREF may not allow VREF to deviate from VREF(DC) by more than ± 1% VDD (for reference : approx. ± 15mV)
4.For reference : approx. VDD/2 ± 15mV
5.VIH(dc) is used as a simplified symbol for VIH.DQ(DC100)
6.VIL(dc) is used as a simplified symbol for VIL.DQ(DC100)
7.VIH(ac) is used as a simplified symbol for VIH.DQ(AC175), VIH.DQ(AC150) ; VIH.DQ(AC175) value is used when VREF + 175mV is referenced, VIH.DQ(AC150) value is used when VREF + 150mV is referenced.
8.VIL(ac) is used as a simplified symbol for VIL.DQ(AC175), VIL.DQ(AC150) ; VIL.DQ(AC175) value is used when VREF - 175mV is referenced, VIL.DQ(AC150) value is used when VREF - 150mV is referenced.
- 12 -
|
|
Rev. 1.01 |
K4B1G0846G |
”YNN MacshbM· |
|
datasheet |
DDR3 SDRAM |
|
K4B1G0446G |
|
|
The dc-tolerance limits and ac-noise limits for the reference voltages VREFCA and VREFDQ are illustrate in Figure 1. It shows a valid reference voltage VREF(t) as a function of time. (VREF stands for VREFCA and VREFDQ likewise).
VREF(DC) is the linear average of VREF(t) over a very long period of time (e.g. 1 sec). This average has to meet the min/max requirement in Table 7 on page 12. Furthermore VREF(t) may temporarily deviate from VREF(DC) by no more than ± 1% VDD.
voltage |
VDD |
VSS |
time |
Figure 1. Illustration of VREF(DC) tolerance and VREF ac-noise limits
The voltage levels for setup and hold time measurements VIH(AC), VIH(DC), VIL(AC) and VIL(DC) are dependent on VREF.
"VREF" shall be understood as VREF(DC), as defined in Figure 1 .
This clarifies, that dc-variations of VREF affect the absolute voltage a signal has to reach to achieve a valid high or low level and therefore the time to which setup and hold is measured. System timing and voltage budgets need to account for VREF(DC) deviations from the optimum position within the data-eye of the input signals.
This also clarifies that the DRAM setup/hold specification and derating values need to include time and voltage associated with VREF ac-noise. Timing and voltage effects due to ac-noise on VREF up to the specified limit (+/-1% of VDD) are included in DRAM timings and their associated deratings.
- 13 -
|
|
Rev. 1.01 |
K4B1G0846G |
”YNN MacshbM· |
|
datasheet |
DDR3 SDRAM |
|
K4B1G0446G |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
tDVAC |
|
|
|
|
|
||||
|
CK-CK) |
|
VIH.DIFF.AC.MIN |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
VIH.DIFF.MIN |
|
|
|
|
|
|||||||||||||||||||
|
DQS-DQS, |
|
|
|
|
|
|
|||||||||||||||||||
|
|
0.0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
(i.e. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
half cycle |
|
|
|
|
|
|||||||||||
Voltage |
|
VIL.DIFF.MAX |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||
Input |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Differential |
|
VIL.DIFF.AC.MAX |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
tDVAC
time
Figure 2. Definition of differential ac-swing and "time above ac level" tDVAC
[ Table 9 ] Differential AC & DC Input Levels
Symbol |
Parameter |
DDR3-800/1066/1333/1600/1866 |
unit |
NOTE |
||
min |
max |
|||||
|
|
|
|
|||
VIHdiff |
differential input high |
+0.2 |
NOTE 3 |
V |
1 |
|
VILdiff |
differential input low |
NOTE 3 |
-0.2 |
V |
1 |
|
VIHdiff(AC) |
differential input high ac |
2 x (VIH(AC) - VREF) |
NOTE 3 |
V |
2 |
|
VILdiff(AC) |
differential input low ac |
NOTE 3 |
2 x (VIL(AC) - VREF) |
V |
2 |
NOTE :
1.Used to define a differential signal slew-rate.
2.for CK - CK use VIH/VIL(AC) of ADD/CMD and VREFCA; for DQS - DQS, DQSL - DQSL, DQSU - DQSU use VIH/VIL(AC) of DQs and VREFDQ; if a reduced ac-high or ac-low level is used for a signal group, then the reduced level applies also here.
3.These values are not defined, however they single-ended signals CK, CK, DQS, DQS, DQSL, DQSL, DQSU, DQSU need to be within the respective limits (VIH(DC) max,
VIL(DC)min) for single-ended signals as well as the limitations for overshoot and undershoot. Refer to "overshoot and Undershoot Specification"
[ Table 10 ] Allowed time before ringback (tDVAC) for CK - CK and DQS - DQS
|
tDVAC [ps] @ |VIH/Ldiff(AC)| |
tDVAC [ps] @ |VIH/Ldiff(AC)| |
tDVAC [ps] @ |VIH/Ldiff(AC)| |
tDVAC [ps] @ |VIH/Ldiff(AC)| |
||||||||
Slew Rate [V/ns] |
|
= 350mV |
|
= 300mV |
|
= 270mV |
|
= 250mV |
||||
|
min |
|
max |
min |
|
max |
min |
|
max |
min |
|
max |
> 4.0 |
75 |
|
- |
175 |
|
- |
TBD |
|
- |
TBD |
|
- |
|
|
|
|
|
|
|
|
|
|
|
|
|
4.0 |
57 |
|
- |
170 |
|
- |
TBD |
|
- |
TBD |
|
- |
|
|
|
|
|
|
|
|
|
|
|
|
|
3.0 |
50 |
|
- |
167 |
|
- |
TBD |
|
- |
TBD |
|
- |
|
|
|
|
|
|
|
|
|
|
|
|
|
2.0 |
38 |
|
- |
163 |
|
- |
TBD |
|
- |
TBD |
|
- |
|
|
|
|
|
|
|
|
|
|
|
|
|
1.8 |
34 |
|
- |
162 |
|
- |
TBD |
|
- |
TBD |
|
- |
|
|
|
|
|
|
|
|
|
|
|
|
|
1.6 |
29 |
|
- |
161 |
|
- |
TBD |
|
- |
TBD |
|
- |
|
|
|
|
|
|
|
|
|
|
|
|
|
1.4 |
22 |
|
- |
159 |
|
- |
TBD |
|
- |
TBD |
|
- |
|
|
|
|
|
|
|
|
|
|
|
|
|
1.2 |
13 |
|
- |
155 |
|
- |
TBD |
|
- |
TBD |
|
- |
|
|
|
|
|
|
|
|
|
|
|
|
|
1.0 |
0 |
|
- |
150 |
|
- |
TBD |
|
- |
TBD |
|
- |
|
|
|
|
|
|
|
|
|
|
|
|
|
< 1.0 |
0 |
|
- |
150 |
|
- |
TBD |
|
- |
TBD |
|
- |
|
|
|
|
|
|
|
|
|
|
|
|
|
- 14 -
|
|
Rev. 1.01 |
K4B1G0846G |
”YNN MacshbM· |
|
datasheet |
DDR3 SDRAM |
|
K4B1G0446G |
|
|
Each individual component of a differential signal (CK, DQS, DQSL, DQSU, CK, DQS, DQSL, or DQSU) has also to comply with certain requirements for single-ended signals.
CK and CK have to approximately reach VSEHmin / VSELmax [approximately equal to the ac-levels { VIH(AC) / VIL(AC)} for ADD/CMD signals] in every half-cycle.
DQS, DQSL, DQSU, DQS, DQSL have to reach VSEHmin / VSELmax [approximately the ac-levels { VIH(AC) / VIL(AC)} for DQ signals] in every half-cycle
proceeding and following a valid transition.
Note that the applicable ac-levels for ADD/CMD and DQ’s might be different per speed-bin etc. E.g. if VIH150(AC)/VIL150(AC) is used for ADD/CMD sig-
nals, then these ac-levels apply also for the single-ended signals CK and CK .
|
VDD or VDDQ |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
VSEH min |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
VSEH |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||||||||||||
VDD/2 or VDDQ/2 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
CK or DQS |
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
VSEL max |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
VSEL |
|||||||||
|
VSS or VSSQ |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
time |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Figure 3. Single-ended requirement for differential signals |
Note that while ADD/CMD and DQ signal requirements are with respect to VREF, the single-ended components of differential signals have a requirement with respect to VDD/2; this is nominally the same. The transition of single-ended signals through the ac-levels is used to measure setup time. For singleended components of differential signals the requirement to reach VSELmax, VSEHmin has no bearing on timing, but adds a restriction on the common mode characteristics of these signals.
[ Table 11 ] Single-ended levels for CK, DQS, DQSL, DQSU, CK, DQS, DQSL, or DQSU
Symbol |
Parameter |
|
DDR3-1066/1333/1600/1866 |
Unit |
NOTE |
||||
|
Min |
Max |
|||||||
|
|
|
|
|
|
|
|
||
VSEH |
Single-ended high-level for strobes |
|
(VDD/2)+0.175 |
NOTE3 |
V |
1, 2 |
|||
|
|
|
|
|
(VDD/2)+0.175 |
|
|
|
|
Single-ended high-level for CK, CK |
|
NOTE3 |
V |
1, 2 |
|||||
|
|
||||||||
VSEL |
Single-ended low-level for strobes |
|
NOTE3 |
(VDD/2)-0.175 |
V |
1, 2 |
|||
|
|
|
|
|
|
(VDD/2)-0.175 |
|
|
|
Single-ended low-level for CK, CK |
|
NOTE3 |
V |
1, 2 |
|||||
|
|
NOTE :
1.For CK, CK use VIH/VIL(AC) of ADD/CMD; for strobes (DQS, DQS, DQSL, DQSL, DQSU, DQSU) use VIH/VIL(AC) of DQs.
2.VIH(AC)/VIL(AC) for DQs is based on VREFDQ; VIH(AC)/VIL(AC) for ADD/CMD is based on VREFCA; if a reduced ac-high or ac-low level is used for a signal group, then the reduced level applies also here
3.These values are not defined, however the single-ended signals CK, CK, DQS, DQS, DQSL, DQSL, DQSU, DQSU need to be within the respective limits (VIH(DC) max, VIL(DC)min) for single-ended signals as well as the limitations for overshoot and undershoot. Refer to "Overshoot and Undershoot Specification"
- 15 -
|
|
Rev. 1.01 |
K4B1G0846G |
”YNN MacshbM· |
|
datasheet |
DDR3 SDRAM |
|
K4B1G0446G |
|
|
To guarantee tight setup and hold times as well as output skew parameters with respect to clock and strobe, each cross point voltage of differential input signals (CK, CK and DQS, DQS) must meet the requirements in below table. The differential input cross point voltage VIX is measured from the actual cross point of true and complement signal to the mid level between of VDD and VSS.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
VDD |
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
CK, |
|
DQS |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
VIX |
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
VDD/2 |
|
|
||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
VIX |
|
|
|
VIX |
|
CK, DQS |
|
|
||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
VSS |
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Figure 4. VIX Definition |
|
|
||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||||||||||
[ Table 12 ] Cross point voltage for differential input signals (CK, DQS) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Symbol |
|
|
|
|
Parameter |
|
|
|
|
|
|
DDR3-800/1066/1333/1600/1866 |
Unit |
NOTE |
||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
Min |
|
|
|
|
|
Max |
||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
-150 |
|
|
150 |
mV |
|
||||||||||||
VIX |
Differential Input Cross Point Voltage relative to VDD/2 for CK,CK |
|
||||||||||||||||||||||||||||||||||||||||||||||
-175 |
|
|
175 |
mV |
1 |
|||||||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||||
VIX |
Differential Input Cross Point Voltage relative to VDD/2 for DQS,DQS |
-150 |
|
|
150 |
mV |
|
|||||||||||||||||||||||||||||||||||||||||
NOTE : |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1. Extended range for VIX is only allowed for clock and if single-ended clock input signals CKand CK are monotonic, have a single-ended swing VSEL / VSEH of at least VDD/2
±250 mV, and the differential slew rate of CK-CK is larger than 3 V/ ns. Refer to Table 11 on page 15 for VSEL and VSEH standard values. 2. The relation between VIX Min/Max and VSEL/VSEH should satisfy following.
(VDD/2) + VIX(Min) - VSEL ≥ 25mV VSEH - ((VDD/2) + VIX(Max)) ≥ 25mV
See 14.3 “Address/Command Setup, Hold and Derating :” on page 48 for single-ended slew rate definitions for address and command signals. See 14.4 “Data Setup, Hold and Slew Rate Derating :” on page 54 for single-ended slew rate definitions for data signals.
Input slew rate for differential signals (CK, CK and DQS, DQS) are defined and measured as shown in Table 13 and Figure 5.
[ Table 13 ] Differential input slew rate definition
|
Description |
Measured |
|
Defined by |
||||||||||||||
|
From |
To |
|
|||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
VILdiffmax |
VIHdiffmin |
VIHdiffmin - VILdiffmax |
|||
Differential input slew rate for rising edge (CK-CK and DQS-DQS) |
||||||||||||||||||
|
Delta TRdiff |
|
||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
VIHdiffmin |
VILdiffmax |
VIHdiffmin - VILdiffmax |
|||
Differential input slew rate for falling edge (CK-CK and DQS-DQS) |
||||||||||||||||||
|
Delta TFdiff |
|
||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
NOTE : |
|
|
|
|
|
|||||||||||||
The differential signal (i.e. CK - |
CK |
and DQS - |
DQS) |
must be linear between these thresholds. |
|
|
|
|
|
VIHdiffmin |
|
0 |
|
VILdiffmax |
delta TFdiff |
delta TRdiff |
Figure 5. Differential Input Slew Rate definition for DQS, DQS, and CK, CK
- 16 -
|
|
|
|
|
|
Rev. 1.01 |
|
|
K4B1G0846G |
”YNN MacshbM· |
|||||
|
datasheet |
DDR3 SDRAM |
|||||
|
K4B1G0446G |
|
|
|
|
|
|
|
9. AC & DC Output Measurement Levels |
|
|
|
|
|
|
|
9.1 Single-ended AC & DC Output Levels |
|
|
|
|
|
|
|
[ Table 14 ] Single-ended AC & DC output levels |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Symbol |
Parameter |
DDR3-800/1066/1333/1600/1866 |
Units |
NOTE |
|
|
|
VOH(DC) |
DC output high measurement level (for IV curve linearity) |
|
0.8 x VDDQ |
V |
|
|
|
VOM(DC) |
DC output mid measurement level (for IV curve linearity) |
|
0.5 x VDDQ |
V |
|
|
|
VOL(DC) |
DC output low measurement level (for IV curve linearity) |
|
0.2 x VDDQ |
V |
|
|
|
VOH(AC) |
AC output high measurement level (for output SR) |
|
VTT + 0.1 x VDDQ |
V |
1 |
|
|
VOL(AC) |
AC output low measurement level (for output SR) |
|
VTT - 0.1 x VDDQ |
V |
1 |
|
NOTE : 1. The swing of +/-0.1 x VDDQ is based on approximately 50% of the static single ended output high or low swing with a driver impedance of 40Ω and an effective test load of 25Ω to VTT=VDDQ/2.
[ Table 15 ] Differential AC & DC output levels
Symbol |
Parameter |
DDR3-800/1066/1333/1600/1866 |
Units |
NOTE |
VOHdiff(AC) |
AC differential output high measurement level (for output SR) |
+0.2 x VDDQ |
V |
1 |
VOLdiff(AC) |
AC differential output low measurement level (for output SR) |
-0.2 x VDDQ |
V |
1 |
NOTE : 1. The swing of +/-0.2xVDDQ is based on approximately 50% of the static single ended output high or low swing with a driver impedance of 40Ω and an effective test load of 25Ω to VTT=VDDQ/2 at each of the differential outputs.
With the reference load for timing measurements, output slew rate for falling and rising edges is defined and measured between VOL(AC) and VOH(AC) for single ended signals as shown in Table 16 and Figure 6.
[ Table 16 ] Single-ended output slew rate definition
Description |
Measured |
|
Defined by |
||
From |
To |
|
|||
|
|
|
|
||
Single ended output slew rate for rising edge |
VOL(AC) |
VOH(AC) |
|
VOH(AC)-VOL(AC) |
|
|
Delta TRse |
||||
|
|
|
|
||
|
|
|
|
|
|
Single ended output slew rate for falling edge |
VOH(AC) |
VOL(AC) |
|
VOH(AC)-VOL(AC) |
|
|
Delta TFse |
||||
|
|
|
|
||
|
|
|
|
|
|
NOTE : Output slew rate is verified by design and characterization, and may not be subject to production test.
[ Table 17 ] Single-ended output slew rate
Parameter |
Symbol |
DDR3-800 |
DDR3-1066 |
DDR3-1333 |
DDR3-1600 |
DDR3-1866 |
Units |
||||||
Min |
Max |
Min |
Max |
Min |
Max |
Min |
Max |
Min |
Max |
||||
|
|
|
|||||||||||
Single ended output slew rate |
SRQse |
2.5 |
5 |
2.5 |
5 |
2.5 |
5 |
2.5 |
5 |
2.5 |
51) |
V/ns |
Description : SR : Slew Rate
Q : Query Output (like in DQ, which stands for Data-in, Query-Output)
se : Single-ended Signals For Ron = RZQ/7 setting
NOTE : 1) In two cased, a maximum slew rate of 6V/ns applies for a single DQ signal within a byte lane.
- Case_1 is defined for a single DQ signal within a byte lane which is switching into a certain direction (either from high to low of low to high) while all remaining DQ signals in the same byte lane are static (i.e they stay at either high or low).
- Case_2 is defined for a single DQ signals in the same byte lane are switching into the opposite direction (i.e. from low to high or high to low respectively). For the remaining DQ signal switching into the opposite direction, the regular maximum limit of 5 V/ns applies.
VOH(AC)
VTT
VOL(AC)
delta TFse |
delta TRse |
Figure 6. Single-ended Output Slew Rate Definition
- 17 -
|
|
Rev. 1.01 |
K4B1G0846G |
”YNN MacshbM· |
|
datasheet |
DDR3 SDRAM |
|
K4B1G0446G |
|
|
With the reference load for timing measurements, output slew rate for falling and rising edges is defined and measured between VOLdiff(AC) and VOHdiff(AC) for differential signals as shown in Table 18 and Figure 7.
[ Table 18 ] Differential output slew rate definition
Description |
Measured |
|
Defined by |
||
From |
To |
|
|||
|
|
|
|
||
Differential output slew rate for rising edge |
VOLdiff(AC) |
VOHdiff(AC) |
|
VOHdiff(AC)-VOLdiff(AC) |
|
|
Delta TRdiff |
||||
|
|
|
|
||
Differential output slew rate for falling edge |
VOHdiff(AC) |
VOLdiff(AC) |
|
VOHdiff(AC)-VOLdiff(AC) |
|
|
Delta TFdiff |
||||
|
|
|
|
||
|
|
|
|
|
|
NOTE : Output slew rate is verified by design and characterization, and may not be subject to production test.
[ Table 19 ] Differential output slew rate
Parameter |
Symbol |
DDR3-800 |
DDR3-1066 |
DDR3-1333 |
DDR3-1600 |
DDR3-1866 |
Units |
||||||
Min |
Max |
Min |
Max |
Min |
Max |
Min |
Max |
Min |
Max |
||||
|
|
|
|||||||||||
Differential output slew rate |
SRQdiff |
5 |
10 |
5 |
10 |
5 |
10 |
5 |
10 |
5 |
12 |
V/ns |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Description : SR : Slew Rate |
|
|
|
|
|
|
|
|
|
|
|
|
Q : Query Output (like in DQ, which stands for Data-in, Query-Output)
diff : Differential Signals For Ron = RZQ/7 setting
VOHdiff(AC)
VTT
VOLdiff(AC)
delta TFdiff |
delta TRdiff |
Figure 7. Differential Output Slew Rate Definition
Figure 8 represents the effective reference load of 25 ohms used in defining the relevant AC timing parameters of the device as well as output slew rate measurements.
It is not intended as a precise representation of any particular system environment or a depiction of the actual load presented by a production tester. System designers should use IBIS or other simulation tools to correlate the timing reference load to a system environment. Manufacturers correlate to their production test conditions, generally one or more coaxial transmission lines terminated at the tester electronics.
VDDQ
DQ
CK/CK DUT DQS VTT = VDDQ/2
DQS
25Ω
Reference
Point
Figure 8. Reference Load for AC Timing and Output Slew Rate
- 18 -
|
|
Rev. 1.01 |
K4B1G0846G |
”YNN MacshbM· |
|
datasheet |
DDR3 SDRAM |
|
K4B1G0446G |
|
|
[ Table 20 ] AC overshoot/undershoot specification for Address and Control pins (A0-A12, BA0-BA2. CS. RAS. CAS. WE. CKE, ODT)
Parameter |
|
|
Specification |
|
|
Unit |
|
DDR3-800 |
DDR3-1066 |
DDR3-1333 |
DDR3-1600 |
DDR3-1866 |
|||
|
|
||||||
Maximum peak amplitude allowed for overshoot area (See Figure 9) |
0.4V |
0.4V |
0.4V |
0.4V |
0.4V |
V |
|
|
|
|
|
|
|
|
|
Maximum peak amplitude allowed for undershoot area (See Figure 9) |
0.4V |
0.4V |
0.4V |
0.4V |
0.4V |
V |
|
|
|
|
|
|
|
|
|
Maximum overshoot area above VDD (See Figure 9) |
0.67V-ns |
0.5V-ns |
0.4V-ns |
0.33V-ns |
0.28V-ns |
V-ns |
|
Maximum undershoot area below VSS (See Figure 9) |
0.67V-ns |
0.5V-ns |
0.4V-ns |
0.33V-ns |
0.28V-ns |
V-ns |
Maximum Amplitude
Overshoot Area
Volts VDD
(V)
VSS
Undershoot Area
Maximum Amplitude
Time (ns)
Figure 9. Address and Control Overshoot and Undershoot Definition
[ Table 21 ] AC overshoot/undershoot specification for Clock, Data, Strobe and Mask (DQ, DQS, DQS, DM, CK, CK)
Parameter |
|
|
Specification |
|
|
Unit |
|
DDR3-800 |
DDR3-1066 |
DDR3-1333 |
DDR3-1600 |
DDR3-1866 |
|||
|
|
||||||
Maximum peak amplitude allowed for overshoot area (See Figure 10) |
0.4V |
0.4V |
0.4V |
0.4V |
0.4V |
V |
|
|
|
|
|
|
|
|
|
Maximum peak amplitude allowed for undershoot area (See Figure 10) |
0.4V |
0.4V |
0.4V |
0.4V |
0.4V |
V |
|
|
|
|
|
|
|
|
|
Maximum overshoot area above VDDQ (See Figure 10) |
0.25V-ns |
0.19V-ns |
0.15V-ns |
0.13V-ns |
0.11V-ns |
V-ns |
|
Maximum undershoot area below VSSQ (See Figure 10) |
0.25V-ns |
0.19V-ns |
0.15V-ns |
0.13V-ns |
0.11V-ns |
V-ns |
Maximum Amplitude
Overshoot Area
Volts VDDQ
(V)
VSSQ
Undershoot Area
Maximum Amplitude
Time (ns)
Figure 10. Clock, Data, Strobe and Mask Overshoot and Undershoot Definition
- 19 -
|
|
Rev. 1.01 |
K4B1G0846G |
”YNN MacshbM· |
|
datasheet |
DDR3 SDRAM |
|
K4B1G0446G |
|
|
A functional representation of the output buffer is shown below. Output driver impedance RON is defined by the value of external reference resistor RZQ as follows:
RON34 = RZQ/7 (Nominal 34.3ohms +/- 10% with nominal RZQ=240ohm)
The individual Pull-up and Pull-down resistors (RONpu and RONpd) are defined as follows
RONpu = |
VDDQ-VOUT |
under the condition that RONpd is turned off |
|
l Iout l |
|||
|
|
||
RONpd = |
VOUT |
under the condition that RONpu is turned off |
|
l Iout l |
|||
|
|
|
Output Driver |
|
VDDQ |
|
Ipu |
To |
RONPu |
other |
|
circuity |
DQ |
|
|
|
Iout |
|
RONPd |
|
Vout |
|
Ipd |
|
VSSQ |
Figure 11. Output Driver : Definition of Voltages and Currents
[ Table 22 ] Output Driver DC Electrical Characteristics, assuming RZQ=240ohms ; entire operating temperature range ; after proper ZQ calibration
RONnom |
|
Resistor |
Vout |
Min |
Nom |
Max |
Units |
NOTE |
|
|
|
VOLdc = 0.2 x VDDQ |
0.6 |
1.0 |
1.1 |
|
1,2,3 |
|
|
RON34pd |
VOMdc = 0.5 x VDDQ |
0.9 |
1.0 |
1.1 |
|
1,2,3 |
34Ohms |
|
|
VOHdc = 0.8 x VDDQ |
0.9 |
1.0 |
1.4 |
RZQ/7 |
1,2,3 |
|
|
VOLdc = 0.2 x VDDQ |
0.9 |
1.0 |
1.4 |
1,2,3 |
||
|
|
|
|
|||||
|
|
RON34pu |
VOMdc = 0.5 x VDDQ |
0.9 |
1.0 |
1.1 |
|
1,2,3 |
|
|
|
VOHdc = 0.8 x VDDQ |
0.6 |
1.0 |
1.1 |
|
1,2,3 |
|
|
|
VOLdc = 0.2 x VDDQ |
0.6 |
1.0 |
1.1 |
|
1,2,3 |
|
|
RON40pd |
VOMdc = 0.5 x VDDQ |
0.9 |
1.0 |
1.1 |
|
1,2,3 |
40Ohms |
|
|
VOHdc = 0.8 x VDDQ |
0.9 |
1.0 |
1.4 |
RZQ/6 |
1,2,3 |
|
|
VOLdc = 0.2 x VDDQ |
0.9 |
1.0 |
1.4 |
1,2,3 |
||
|
|
|
|
|||||
|
|
RON40pu |
VOMdc = 0.5 x VDDQ |
0.9 |
1.0 |
1.1 |
|
1,2,3 |
|
|
|
VOHdc = 0.8 x VDDQ |
0.6 |
1.0 |
1.1 |
|
1,2,3 |
Mismatch between Pull-up and Pull-down, |
VOMdc = 0.5 x VDDQ |
-10 |
|
10 |
% |
1,2,4 |
||
|
MMpupd |
|
||||||
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
NOTE :
1.The tolerance limits are specified after calibration with stable voltage and temperature. For the behavior of the tolerance limits if temperature or voltage changes after calibration, see following section on voltage and temperature sensitivity
2.The tolerance limits are specified under the condition that VDDQ = VDD and that VSSQ = VSS
3.Pull-down and pull-up output driver impedance are recommended to be calibrated at 0.5 X VDDQ. Other calibration schemes may be used to achieve the linearity spec shown
above, e.g. calibration at 0.2 X VDDQ and 0.8 X VDDQ
4. Measurement definition for mismatch between pull-up and pull-down, MMpupd: Measure RONpu and RONpd. both at 0.5 X VDDQ:
MMpupd = RONpu - RONpd x 100
RONnom