COPYRIGHT
All rights reserved. This manual is proprietary to SAMSUNG Electronics Co., Ltd. and is protected by copyright. No information contained herein may be copied, translated, transcribed or duplicated for any commercial purposes or disclosed to a third party in any form without the prior written consent of SAMSUNG Electronics Co., Ltd.
TRADEMARKS
Product names mentioned in this manual may be trademarks and/or registered trademarks of their respective companies.
DISCLAIMER
This manual should be read and used as a guideline for properly installing and operating the product. Every effort has been made to eliminate errors and ambiguities in the information contained in this document. All reasonable care has been made to ensure that this document is accurate. SAMSUNG Electronics Co., Ltd. disclaims all liabilities for damages arising from the erroneous interpretation or use of information presented in this manual. If you have any comments on this manual, please contact our documentation center at the following webpage: http://www.samsungdocs.com
PUBLICATION INFORMATION
SAMSUNG Electronics Co., Ltd. reserves the right without prior notice to revise information in this publication for any reason. SAMSUNG Electronics Co., Ltd. also reserves the right without prior notice to make changes in design or components of equipment as engineering and manufacturing may warrant.
SAMSUNG IPX-G5X0 Installation Manual v1.0 Mar 2016
3
Conventions
The following types of paragraphs contain special information that must be carefully read and thoroughly understood. Such information may or may not be enclosed in a rectangular box, separating it from the main text, but is always preceded by an icon and/or a bold title.
Console Screen Output
A lined box with ‘Courier New’ font will be used to distinguish between the main content and
console output screen text.
Bold Courier New’ font will indicate the value entered by the operator on the console screen.
Revision History
Revision
Date Of Issue
Remarks
1.0
Mar 2016
First Version
Provides information or instructions that the reader should follow in order to avoid personal
injury or fatality.
Provides information or instructions that the reader should follow in order to avoid a service
failure or damage to the system.
Provides the operator with checkpoints for stable system operation.
Indicates additional information as a reference.
SAMSUNG IPX-G5X0 Installation Manual v1.0 Mar 2016
4
Table of Contents
SAMSUNG IPX-G5X0 Installation Manual v1.0 Mar 2016
Size
Size (W x D x H): 441.5 × 352 × 44mm
19” Rack Installation: 1U
Power
AC 110/220V ICMUt, DC +12 V/5.5 A Output
IPX-G500B Base Unit
2 Gigabit Ethernet ports / 1 USB port / 1 Console port
Optional Power Redundancy
4 Universal Card Slots
RJ-45 connector
Card Options: 4 port FXS, 4 port FXO, 2 port PRI
No Card Type Limit
IPX-G520S
20 port FXS Expansion Cabinet
Optional Power Redundancy
Expandable to maximum of 6 cabinets (240 ports)
50p Champ Connector
IPX-G540S
40 port FXS Expansion Cabinet
Optional Power Redundancy
Expandable to maximum of 6 cabinets (240 ports)
50p Champ Connector
Max stations
FXS port
256
136 port power redundancy
SIP Phone Survivability
512
UDP/TLS are same
Simultaneous Survivable Stations
768
Survival mode
Max trunks
FXO port
16
PRI channel
240 (E1 PRI)
8 ports
SIP channel
256 Simultaneous Trunk Total
256
IPX-G5X0 Series Specifications
Hardware Specifications
Station & Trunk Capacity
5
SAMSUNG IPX-G5X0 Installation Manual v1.0 Mar 2016
IPX-G5X0 Series Installation
The IPX-G5X0 series gateways provide interfaces to a number of protocols such as PRI, FXS and FXO. It interfaces with the Samsung Communication Manager (SCM) by SIP protocol and can be extended to remote locations as a survivable gateway.
To install an IPX-G5X0 Series Media Gateway you first have to setup your gateway information in the Samsung Communication Manager (SCM). Additionally some basic information must be set within the IPX-G5X0 Series system.
The IPX-GX0 Series is compatible with SCM software version 5.4 or higher. If your SCME software version is prior to version 5.4, you must upgrade the SCM first. Please refer to the SCM documentation for upgrade instructions.
6
SAMSUNG IPX-G5X0 Installation Manual v1.0 Mar 2016
SCM Configuration
Preparation
The following hardware is provided with your IPX-G5X0 Server:
AC Power Cord RJ45 to DB9 Serial Cable
Gateway Link Setting
Begin by creating a new gateway link in the SCM Administrator at:
[Configuration> Gateway> Gateway Link Setting]
Enter a gateway Name, Local IP Address, Public IP Address, and enable or disable NAT.
Note: If NAT is enabled, then Public IP Address should be entered.
7
SAMSUNG IPX-G5X0 Installation Manual v1.0 Mar 2016
Gateway Configuration
In the SCM Administrator configure a new gateway at:
[Configuration> Gateway> IPX Setting> Gateway Configuration]
Basic Configuration tab
Enter the Profile Login ID, which should be the same as the Gateway Name. Then enter the Profile Login Passcode (samsung*# by default). You don’t need to enter any IP addresses here. These fields are
not needed for this implementation.
Slot Configuration
There are 4 slots on the back of the gateway. This tells the SCM what is configured on each slot. On the left side of the slot configuration tab, enter the slot and expansion configuration of the gateway. Select the option cards and expansion cabinets installed in the gateway. After the installation is complete, the actual states of slots and expansions will be updated on the right side.
8
SAMSUNG IPX-G5X0 Installation Manual v1.0 Mar 2016
Expansion Private Configuration
The SCM supports expansion analog gateways. This table sets up the analog line gateways that will be provided with the new G5X0 gateway.
For multiple cabinet configurations, enter the IP address and ports of installed expansion cabinets.
Network Configuration
In the SCM Administrator, enter the network information for the gateway at:
[Configuration > Gateway > IPX Setting > Gateway Network Configuration]
Depending on whether you are using a WAN interface, set Use WAN to ‘Yes’ or ‘No’. Then enter the Default Gateway IP, LAN IP Address, LAN Subnet Mask, and GWU IP Address. The IPX-G500B has 2 internal hardware units, the CMU and GWU. The LAN IP Address will be assigned to CMU and GWU IP Address will be assigned to the GWU board. If you have optional universal cards, enter Slot IP Addresses for optional cards. (PRI cards need
individual IP addresses, etc.)
If you selected to Use WAN, enter WAN IP Address and WAN Subnet Mask. The IPX-G5X0 Series has an internal DHCP server. If you want to connect another devices, for example
IP phones, to the LAN and want to receive IP addresses automatically, set the DHCP IP Address Range – Start and DHCP IP Address Range – End. The DHCP lease time can also be specified in seconds using the DHCP IP Lease Time field.
Note: The IPX-G500B has 2 GbE ports. If you want to use WAN/LAN, you must connect WAN to GbE port 1 and LAN to GbE port 2. If you want to use LAN only, you can connect to any GbE port.