Note (1): If the cell is kept as ex-factory status (50% of charge),
the capacity recovery rate is more than 80%.
1
-SAMSUNG SDI Confidential Proprietary –
Spec. No.
ICR18650-26F Version No.
0.0
4. Outline Dimensions
See the attachment (Fig. 1)
5. Appearance
There shall be no such defects as scratch, rust, discoloration, leakage which
may adversely affect commercial value of the cell.
6. Standard Test Conditions
6.1 Environmental Conditions
Unless otherwise specified, all tests stated in this specification are
conducted at temperature 25±5℃ and humidity 65±20%.
6.2 Measuring Equipment
(1) Ammeter and Voltmeter
The ammeter and voltmeter should have an accuracy of
the grade 0.5 or higher.
(2) Slide caliper
The slide caliper should have 0.01 mm scale.
(3) Impedance meter
The impedance meter with AC 1kHz should be used.
7. Characteristics
7.1 Standard Charge
This "Standard Charge" means charging the cell with charge current
1300mA and constant voltage 4.2V at 25℃ for 3hours.
7.2 Standard Discharge Capacity
The standard discharge capacity is the initial discharge capacity of the cell, which is
measured with discharge current of 520mA with 2.75V cut-off at 25℃ within 1hour
after the standard charge.
Standard Discharge Capacity ≥ 2550mAh
7.3 Initial internal impedance
Initial internal impedance measured at AC 1kHz after rated charge.
Initial internal impedance ≤ 100mΩ
7.4 Temperature Dependence of Discharge Capacity
Capacity comparison at each temperature, measured with discharge
constant current 520mA and 2.75V cut-off after the standard charge is
as follows.
Charge Temperature Discharge temperature
25℃-10℃0℃25℃40℃
Relative Capacity 50% 80% 100% 80%
Note: If charge temperature and discharge temperature is not the same,
2
-SAMSUNG SDI Confidential Proprietary –
Spec. No.
ICR18650-26F Version No.
0.0
the interval for temperature change is 3 hours.
Percentage as an index of the capacity at 25℃(=2550mAh) is 100%.
7.5 Temperature Dependence of Charge Capacity
Capacity comparison at each temperature, measured with discharge constant current
520mA and 2.75V cut-off after the standard charge is as follows.
Charge temperature Discharge temperature
0℃25℃45℃
25℃
Relative Capacity
80% 100% 80%
Note: If charge temperature and discharge temperature is not the same,
the interval for temperature change is 3 hours.
Percentage as an index of the capacity at 25℃(=2550mAh) is 100%.
7.6 Charge Rate Capabilities
Discharge capacity is measured with constant current 520mA and 2.75V cut-off
after the cell is charged with 4.2V as follows.
Charge Condition
Current
0.2C
(520mA)
0.5C
(1300mA)
1.0C
(2600mA)
2.0C
(5200mA)
Cut-off 7h or 0.05C 2.5h or 0.05C 2.5h or 0.05C 2.5h or 0.05C
Relative
Capacity
100% 95% 90% 80%
Note: Percentage as an index of the capacity at 25℃(=2550mAh) is 100%.
7.7 Discharge Rate Capabilities
Discharge capacity is measured with the various currents in under table and 2.75V
cut-off after the standard charge.
Discharge Condition
Current
Relative
Capacity
0.2C
(520mA)
100% 95% 90% 80%
0.5C
(1300mA)
1.0C
(2600mA)
2.0C
(5200mA)
Note: Percentage as an index of the capacity at 25℃(=2550mAh) is 100%.
7.8 Cycle Life
Each cycle is an interval between the charge (charge current 1300mA)
3
with 2.5h or
-SAMSUNG SDI Confidential Proprietary –
Spec. No.
ICR18650-26F Version No.
0.0
0.05C cut-off and the discharge (discharge current 1500mA) with 2.75V cut-off.
Capacity after 299cycles and plus 1 day, measured under the same condition
in 7.2
Capacity ≥ 1785mAh(70% of the capacity at 25℃)
7.9 Storage Characteristics
Capacity after storage for 30days at 25℃ from the standard charge,
measured with discharge current 1300mA with 2.75V cut-off at 25℃.
Capacity retention(after the storage) ≥ 2040mAh (80% of the capacity at 25℃)
7.10 Status of the cell as of ex-factory
The cell should be shipped in 50% charged state. In this case, OCV is from 3.65V to
3.85V.
8. Mechanical Characteristics
8.1 Drop Test
Test method: Cell(as of shipment or full charged) drop onto the oak-board
(thickness: ≥30mm) from 1.5m height at a random direction 6 times.
Criteria: No leakage
8.2 Vibration Test
Test method: Cell(as of shipment) is vibrated along 2 mutually
perpendicular axes with total excursion of 1.6mm and with
frequency cycling between 10Hz and 55Hz by 1Hz/min.
Criteria: No leakage
9. Safety
9.1 Overcharge Test
Test method: To charge the standard charged cell with 12V and 2.6A at 25℃
for 2.5 hours.
Criteria: No fire, and no explosion.
9.2 External Short-circuit Test
Test method: To short-circuit the standard charged cell by connecting positive and
negative terminal by less than 50mΩ wire for 3hours.
Criteria: No fire, and no explosion.
9.3 Reverse Charge Test
Test method: To charge the standard charged cell with charge current 2.6A
By –12V for 2.5 hours.
Criteria: No fire, and no explosion.
9.4 Heating Test
4