To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before
servicing, unless testing requires power.
TROUBLE DIAGNOSIS
- As the micom dry machine is congured of the complicate structure, there might be the
service call.
Below information is prepared for exact trouble diagnosis and suitable repair guide.
Caution for the Repair and Replacement
Please follow below instruction for the trouble diagnosis and parts replacement.
1) As some electronic components are damaged by the charged static electricity from the resin
part of dryer or the human body, prepare the human body earth or remove the potential
dier ence of the human body and dryer by contacting the power supply plug when the work
contacting to PCB is executed.
2) As the P.C.B assembly is designed for no trouble, do not replace the P.C.B assembly by the
wrong diagnosis and follow the procedure of the trouble diagnosis when the micom is not
operated normally.
To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before
servicing, unless testing requires power.
No ProblemWhat To Do
• All wires are hooked up to their corresponding terminals.
• Dryer is plugged in.
• Blown fuse or circuit breaker.
• Door switch functional...door closed. Check for error code 3 (See
Table for codedenition).
1Will Not Start or Run
Motor runs/ tumbler
2
will not turn
Runs a few minutes
3
and then stops
Blows fuses or trips
4
circuit breaker
Blows fuses or trips
5
circuit breaker (Gas
Model)
Will not heat (motor
6
runs)
Will Not Dry Gas
7
Model Poor Gas
Ignition
• Start/Pause rotary selector dial functional.
• Control Board operational.
• Belt o or broken and Belt Cut-o Switch operates.
• Drive motor functional.
• Check motor winding resistance: 2.88ohms between pin #3 and
4, 3.5ohms between pin #4 and 5.
• Belt o or broken/damaged.
• Idler tension spring too weak or stretched.
• Idler pulley jammed or stuck.
• Lint buildup around drive motor.
• Low voltage present.
• Blower impeller blocked in blower housing.
• Drive motor - start switch contacts stuck closed.
- Is the belt connected well?
- Is the winding of the motor continuous?
(Rotor winding, stator winding, generator)
- Is the motor protector normal?
• If above points are not found, the PCB assembly is out of order.
Replace it.
• During ignition the dryer will draw X amps. With the burner ON,
the dryer will draw X amps. If the dryer is drawing amperages
above this, then the house wiring, fuse box or circuit breaker is
suspected to be at fault.
• Igniter harness loose and shorted to base.
• Incorrect wiring or wire shorted to ground.
• Drive motor winding shorting to ground.
Open heating element.
• Hi-Limit trips easily or is open.
• Regulating thermostat trips easily or is open.
• Membrane switch open.
• Check Thermistor.
When the dryer is operated on a heat setting, the igniter should be
energized and burner shall re within 45 seconds at 120 VAC. The
failure of a component in this system will usually be indicated by one
of three symptoms: