SAMSUNG CS21M16MJZXNWT, CS21K30MJZXNWT Service Manual

COLOR TELEVISION RECEIVER
Chassis : KS9A(P) Model : CS21M16MJZXNWT
CS21K30MJZXNWT
COLOR TELEVISION RECEIVER CONTENTS
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
Precautions
Disassembly and Reassembly
Alignment and Adjustment
Troubleshooting
Exploded View and Parts List
Electrical Parts List
Block Diagram
Wiring Diagram
Schematic Diagrams
SERVICE
Manual
1. Precautions
1-1 Safety Precautions
1. Be sure that all of the built-in protective devices are replaced. Restore any missing protective shields.
2. When reinstalling the chassis and its assemblies, be sure to restore all protective devices, including: nonmetallic control knobs and compartment covers.
3. Make sure that there are no cabinet openings through which people—particularly children—might insert fingers and contact dangerous voltages. Such openings include the spacing between the picture tube and the cabinet mask, excessively wide cabinet
ventilation slots, and improperly fitted back
covers.
If the measured resistance is less than 1.0 megohm or greater than 5.2 megohms, an abnormality exists that must be corrected before the unit is returned to the customer.
4. Leakage Current Hot Check (Figure 1-1): Warning: Do not use an isolation transformer during this test. Use a leakage­current tester or a metering system that complies with American National Standards Institute (ANIS C101.1, Leakage Current for Appliances), and Underwriters Laboratories (UL Publication UL1410, 59.7).
5. With the unit completely reassembled, plug the AC line cord directly into the power outlet. With the unit’s AC switch first in the ON position and then OFF, measure the current between a known earth ground (metal water pipe, conduit, etc.) and all exposed metal parts, including: antennas, handle brackets, metal cabinets, screwheads and control shafts. The current measured should not exceed 0.5 milliamp. Reverse the power­plug prongs in the AC outlet and repeat the test.
Fig. 1-1 AC Leakage Test
6. Antenna Cold Check: With the unit’s AC plug disconnected from the AC source, connect an electrical jumper across the two AC prongs. Connect one lead of the ohmmeter to an AC prong. Connect the other lead to the coaxial connector.
7. X-ray Limits: The picture tube is especially designed to pro­hibit X-ray emissions. To ensure continued X-ray protection, replace the picture tube only with one that is the same type as the original. Carefully reinstall the picture tube shields and mounting hardware; these also provide X-ray protection.
8. High Voltage Limits: High voltage must be measured each time ser­vicing is done on the B+, horizontal deflection or high voltage circuits. Correct operation of the X-ray protection circuits must be reconfirmed whenever they are serviced.
(X-ray protection circuits also may be called
“horizontal disable” or “hold-down”.)
Heed the high voltage limits. These include the X–ray Protection Specifications Label, and the Product Safety and X-ray Warning Note on the service data schematic.
Precautions
1-1
LEAKAGE CURRENT
TESTER
DEVICE UNDER
TEST
TEST ALL
EXPOSED METAL
SURFACES
2-WIRE CORD
ALSO TEST WITH
PLUG REVERSED (USING AC ADAPTER PLUG AS REQUIRED)
EARTH
GROUND
(READING SHOULD
NOT BE ABOVE
0.5mA)
Follow these safety, servicing and ESD precautions to prevent damage and protect against potential hazards such as electrical shock and X-rays.
1-1 Safety Precautions (Continued)
9. High voltage is maintained within specified
limits by close-tolerance, safety-related components and adjustments. If the high voltage exceeds the specified limits, check each of the special components.
10. Design Alteration Warning:
Never alter or add to the mechanical or electrical design of this unit. Example: Do not add auxiliary audio or video connectors. Such alterations might create a safety hazard. Also, any design changes or additions will void the manufacturer’s warranty.
11. Hot Chassis Warning:
Some TV receiver chassis are electrically connected directly to one conductor of the AC power cord. If an isolation transformer is not used, these units may be safely serviced only if the AC power plug is inserted so that the chassis is connected to the ground side of the AC source.
To confirm that the AC power plug is inserted correctly, do the following: Using an AC voltmeter, measure the voltage between the chassis and a known earth ground. If the reading is greater than 1.0V, remove the AC power plug, reverse its polarity and reinsert. Re-measure the voltage between the chassis and ground.
12. Some TV chassis are designed to operate with
85 volts AC between chassis and ground, regardless of the AC plug polarity. These units can be safely serviced only if an isolation transformer inserted between the receiver and the power source.
13. Some TV chassis have a secondary ground
system in addition to the main chassis ground. This secondary ground system is not isolated from the AC power line. The two ground systems are electrically separated by insulating material that must not be defeated or altered.
14. Components, parts and wiring that appear to
have overheated or that are otherwise damaged should be replaced with parts that meet the original specifications. Always determine the cause of damage or overheat­ing, and correct any potential hazards.
15. Observe the original lead dress, especially near the following areas: Antenna wiring, sharp edges, and especially the AC and high voltage power supplies. Always inspect for pinched, out-of-place, or frayed wiring. Do not change the spacing between components and the printed circuit board. Check the AC power cord for damage. Make sure that leads and components do not touch thermally hot parts.
16. Picture Tube Implosion Warning: The picture tube in this receiver employs “integral implosion” protection. To ensure continued implosion protection, make sure that the replacement picture tube is the same as the original.
17. Do not remove, install or handle the picture tube without first putting on shatterproof goggles equipped with side shields. Never handle the picture tube by its neck. Some “in-line” picture tubes are equipped with a permanently attached deflection yoke; do not try to remove such “permanently attached” yokes from the picture tube.
18. Product Safety Notice: Some electrical and mechanical parts have special safety-related characteristics which might not be obvious from visual inspection. These safety features and the protection they give might be lost if the replacement compo­nent differs from the original—even if the replacement is rated for higher voltage, wattage, etc.
Components that are critical for safety are indicated in the circuit diagram by shading, ( ) or ( ).
Use replacement components that have the same ratings, especially for flame resistance and dielectric strength specifications. A replacement part that does not have the same safety characteristics as the original might create shock, fire or other hazards.
Precautions
1-2 Samsung Electronics
!
1-2 Servicing Precautions
1. Servicing precautions are printed on the cabinet. Follow them.
2. Always unplug the unit’s AC power cord from the AC power source before attempting to: (a) Remove or reinstall any component or assembly, (b) Disconnect an electrical plug or connector, (c) Connect a test component in parallel with an electrolytic capacitor.
3. Some components are raised above the printed circuit board for safety. An insulation tube or tape is sometimes used. The internal wiring is sometimes clamped to prevent contact with thermally hot components. Reinstall all such elements to their original position.
4. After servicing, always check that the screws, components and wiring have been correctly reinstalled. Make sure that the portion around the serviced part has not been damaged.
5. Check the insulation between the blades of the AC plug and accessible conductive parts (examples: metal panels, input terminals and earphone jacks).
6. Insulation Checking Procedure: Disconnect the power cord from the AC source and turn the power switch ON. Connect an insulation resistance meter (500V) to the blades of the AC plug.
The insulation resistance between each blade of the AC plug and accessible conductive parts (see above) should be greater than 1 megohm.
7. Never defeat any of the B+ voltage interlocks. Do not apply AC power to the unit (or any of its assemblies) unless all solid-state heat sinks are correctly installed.
8. Always connect a test instrument’s ground lead to the instrument chassis ground before connecting the positive lead; always remove the instrument’s ground lead last.
Precautions
1-3
Warning1: First read the “Safety Precautions” section of this manual. If some unforeseen circumstance creates a conflict between
the servicing and safety precautions, always follow the safety precautions.
Warning2: An electrolytic capacitor installed with the wrong polarity might explode.
1. Some semiconductor (“solid state”) devices are easily damaged by static electricity. Such components are called Electrostatically Sensitive Devices (ESDs); examples include integrated circuits and some field-effect transistors. The following techniques will reduce the occurrence of component damage caused by static electricity.
2. Immediately before handling any semicon ductor components or assemblies, drain the electrostatic charge from your body by touching a known earth ground. Alternatively, wear a discharging wrist-strap device. (Be sure to remove it prior to applying power— this is an electric shock precaution.)
3. After removing an ESD-equipped assembly, place it on a conductive surface such as aluminum foil to prevent accumulation of electrostatic charge.
4. Do not use freon-propelled chemicals. These can generate electrical charges that damage ESDs.
5. Use only a grounded-tip soldering iron when soldering or unsoldering ESDs.
6. Use only an anti-static solder removal device. Many solder removal devices are not rated as “anti-static”; these can accumulate sufficient electrical charge to damage ESDs.
7. Do not remove a replacement ESD from its protective package until you are ready to install it. Most replacement ESDs are packaged with leads that are electrically shorted together by conductive foam, aluminum foil or other conductive materials.
8. Immediately before removing the protective material from the leads of a replacement ESD, touch the protective material to the chassis or circuit assembly into which the device will be installed.
9. Minimize body motions when handling unpackaged replacement ESDs. Motions such as brushing clothes together, or lifting a foot from a carpeted floor can generate enough static electricity to damage an ESD.
Precautions
1-4 Samsung Electronics
1-3 Precautions for Electrostatically Sensitive Devices (ESDs)
Samsung Electronics 2-1
Specifications and IC Data
2. Specifications and IC Data
2-1 Specifications
Television System:
Channels:
Intermediate Frequencies (MHz) :
MODEL
CI
CII
CX
CK
CW
CS
System
Band
VHF
UHF
SYSTEM
IF Carrier Frequency
SYSTEM
PAL-I (UHF)
PAL-I (VHF/UHF)
PAL-B/G, SECAM-B/G
PAL-B/G, D/K, SECAM-B/G, D/K
PAL-B/G, D/K, SECAM-B/G, D/K, NT 4.43
PAL-B/G, D/K, SECAM-B/G, D/K, NT4.43, NT3.58
PAL/SECAM-
B/G,I
2 - 12
21 - 69
PAL/ SECAM- B/G
PAL, SECAM- D/K
1 - 13
21 - 69
PAL/SECAM-D/K,
SECAM-K1
SECAM-K1, PAL-D
2 - 9
13 - 57
PAL - I
NTSC - M
2 - 13
14-69
NTSC - M
Picture Tube:
Power Requirements:
Antenna Input Impedance:
Speaker Impedance
Picture IF Carrier
Sound IF Carrier
Color Sub Carrier
14 Inch
20 Inch
21 Inch
21 Flat
AC 160~300V, 50/60Hz
VHF, UHF : Telescopic dipole antenna (75 ohm unbalanced type )
8 ohm, 7W+7W (MAX)
A34KQV42X
A48KRD82X(H)
A51KQJ63X
A51QDX993X
38.90
33.40
34.47
Quick start, in-line-gun,
Black stripe, 90
38.90
32.40
34.47
38.90
32.90
34.47
degree deflection
38.90
34.40
35.32
2-2 Samsung Electronics
2-2 IC Line Up
Specifications and IC Data
Loc. No Specification Description Remark
HC101 PAP103 IF PRE-AMP
Table 2-1 IC Line-Up
SPM802ER
IC201S
SPM802ERN
IC301
IC501 TDA6107Q RGB DRIVE AMP
IC601
IC801S
IC802 KA7632
IC902 24C08/KS28C040 EEPROM
PC801S TCET1108 / LTV817B PHOTO COUPLER
IC101 U4468B
LA7840
TDA7266S
KA5Q0765R
TTX, English/Croatian/Romanian/Hungarian/Polish/Czech/ Bulgarian/Russian/Portugal
W/O TTX, English/Croatian/Romanian/Hungarian/Polish/Czech/ Bulgarian/Russian/Portugal
VERTICAL OUTPUT
SOUND-AMP (3W x 1CH or 3W x 2CH or 5W x 2CH)
POWER IC (STR)
CUSTOM REGULATOR (5V, 8V, 3.3V)
SIF - IC
Philips
Sanyo
Philips
TEMIC
2-3 Semiconductor Base Diagrams
Specifications and IC Data
Samsung Electronics 2-3
Fig. 2-1 Semiconductor Base Diagrams
ELECTROLYTIC­CONDENSER
TRANSISTOR
TRANSISTOR
2SD1651 2SD1650 2SD2499 KSA614
DIODE
KSC815-Y KSA539-Y BC548 KTC9014
IC
SPM-802ERN(Pin 64) SPM-802ER(Pin 64) X24CO8P(Pin 8) KS24C080(Pin 8) U4468B(Pin 16)
IC
UPC574J
or
KA33V
SAW-FILTER
1
1
1
G3956M K9260M
B
C
E
IC
E B C
TDA6107Q KA7632
TRANSISTOR
LA7840
KSR1012 KSR1010 KSR2010 KTD863-Y KSC2331-Y
E C B
Samsung Electronics 3-1
Disassembly and reassembly
3. Disassembly and Reassembly
3-1 Back Cover Removal
1. After removing the screws, press the tension rib and pull the cabinet backwards.
2. To reassemble, press the tension rib (see diagram).
3-2 Samsung Electronics
3-2 Main Board Removal
Disassembly and reassembly
1. Separate the socket board from the CRT neck.
2. Remove the Anode Cap from the CRT.
3. Remove the main board by pulling it with both hands.
Warning: The FBT is charged with high voltage. Before removing the Anode Cap, discharge the voltage through one of the heat sinks on the main board.
3-3 Speaker Removal
Disassembly and reassembly
Samsung Electronics 3-3
1. Remove the speaker by pressing the tension rib.
3-4 Samsung Electronics
Disassembly and reassembly
3-4 CRT Removal
1. Spread a soft mat on the floor. Place the TV set face down.
2. Remove the 4 nuts mounting the CRT to the front cabi­net. Lift the CRT.
3. Caution: Because of the high vacuum and large surface area of the picture tube, be careful while handling it: (1) Always lift the picture tube by grasping it firmly around the faceplate, (2) Never lift the tube by its neck. (3) Do not scratch the picture tube or apply excessive pressure. Fractures of the glass may cause an implosion.
Alignment and Adjustments
4-1
4. Alignment and Adjustments
4-1 Preadjustment
4-1-1 Factory Mode
1. Do not attempt these adjustments in the Video Mode.
2. The Factory Mode adjustments are necessary when either the EEPROM (IC902) or the CRT is replaced.
3. Do not tamper with the “Adjustment” screen of the Factory Mode menu. This screen is intended only for factory use.
4-1-2 When EEPROM (IC902) Is Replaced
1. When IC902 is replaced all adjustment data revert to initial values. It is necessary to re-program this data.
2. After IC902 is replaced, warm up the TV for 10 seconds.
4-1-3 When CRT Is Replaced
1. Make the following adjustments AFTER set­ting up after setting up purity and conver­gence :
White Balance Sub-Brightness Vertical Center Vertical Size Horizontal Size Fail Safe (This adjustment must be the last step).
2. If the EEPROM or CRT is replaced, set PVA to 40 (factory mode) and set SC as follows.
4-2 Factory/Service Mode
4-2-1 Procedure for the “Adjustment” Mode
1. This mode uses the standard remote control. The Service Mode is activated by entering the following remote-control sequence :
(1) DISPLAY→FACTORY. (2) STAND-BY→ DISPLAYMENUMUTE
POWER ON.
2. The “SERVICE (FACTORY)” message will be displayed. The Service Mode has three compo­nents: ADJUST , OPTION,OPTION1,G2 Adjust and Reset.
3. Access the Adjustment Mode by pressing the “VOLUME” keys ( Up or Down). The adjust­ment parameters are listed in the accompany­ing table, and selected by pressing the CHAN­NEL keys (▲ ,).
4. Selection sequences for the all system:
DOWN or UP key:
AGC>SCT>SBT>BLR>BLB>RG>GG>BG> VSL>VS>VA>HS>SC>CDL>STT>AKB> PDL>NDL>PSR>NSR>VOL>LCO>TXP> MVOL>FMWS>AGCS>OMD>SCL>PWL>
AGN>PEK>ACL>FCO>SCBT>SSP>PSNS
5. The VOLUME keys increase or decrease the adjustment values (stored in the non-volatile memory) when Adjustment Mode is cancelled.
6. Cancel the Adjustment Mode by re-pressing the “FACTORY” or “Power OFF” keys.
4-2-2 Main Adjustment Parameter
Alignment and Adjustments
4-2
Samsung Electronics
OSD FUNCTION RANGE INITIAL DATA REMARK AGC RF AGC 0 … 63 33 SCT Sub contrast 0 … 23 13 SBT Sub brightness 0 … 23 9 BLR Black level offset R 0 … 63 31 BLB Black level offset B 0 … 63 27
RG White point R 0 … 63 32 GG White point G 0 … 63 32(FIX) BG White point B 0 … 63 31
VSL Vertical slope 0 … 63 19
VS Vertical shift 0 … 63 38 VA Vertical amplitude 0 … 63 40(FIX) HS Horizontal shift 0 … 63 30
SC S-correction 0 … 63 24 CDL Cathode drive level 0 … 15 12 STT Sub tint 0 … 7 7 AKB Black current stabilization 0 … 1 0 PDL PAL delay 0 … 15 1 NDL NTSC delay 0 … 15 10 PSR PAL sub color 0 … 23 15 NSR NTSC sub color 0 … 23 10 VOL Volume pre setting 0 … 63 10 LCO SECAM-L Vision IF 0 … 1 0 TXP TTX Position 0 … 15 9
MVOL Melody initial volume adjustment 0 … 50 10 FMWS Narrow-band sound PLL window selection 0 … 1 0 AGCS IF AGC speed 0 … 3 1
OMD Off-set IF demodulator 0 … 63 26 SCL Soft clipping level 0 … 3 1 PWL Peak white limiting 0 … 15 12 AGN FM demodulator gain 0 … 1 1 PEK Peaking center frequency 0 … 3 2 ACL Automatic color limiting 0 … 1 0 FCO Forced color limiting 0 … 1 0
SCBT Screen brightness 0 … 63 45
SSP Sub Sharpness gain adjustment 0 … 23 20
PSNS Identify sensitivity PAL/NTSC decoder 0 … 1 1
Loading...
+ 30 hidden pages