Samsung CE1279 Disassemble

1. Remove five screws from the rear section.
2. Lift the outer panel by pulling it backwards
1. The magnetron includes the shield case, permanent magnet, check coils and 500pF capacitors (all contained in one assembly).
2. Discharge the high voltage capacitor. (See page1-2)
4. Remove screw(1) securing the magnetron supporter.
5. Remove the magnetron supporter.
6. Remove the air cover
7. Remove screw(1) securing the assy thermal cutout switch.
8. Remove screws securing the magnetron to the wave guide.
9. Remove the magnetron very carefully.
10. Remove screws from the back panel to take out fan motor.
11. When removing the magnetron, make sure that its antenna does not hit any adjacent parts.
12. When replacing the magnetron, be sure to remount the magnetron gasket in the correct position, and make sure the gasket is in good condition.
4. Disassembly and Reassembly
4-1 Removal of Outer Panel
Samsung Electronics 4-1
4-2 Replacement of Magnetron and Fan Motor
Screw(1)
Screw(1)
Cover Air
Magnetron
Fan Motor
SCREW
4-3 Replacement of High Voltage Transformer
4-4 Replacement of Door Assembly
4-2 Samsung Electronics
1. Discharge the high voltage capacitor. (See page 1-2)
2. Disconnect all the leads.
3. Remove four screws.
4. When replacing, connect the leads securely.
1. Remove bolts securing the upper hinge and lower hinge, then remove the door assmbly.
2. After replacing the door, check the operation of the primary interlock switch and the interlock monitor switch.
3. Microwave emission should not exceed 5§ /§† (All service adjustments should be made for minimum RF emission.)
Disassembly and Reassembly
H.V.TRANS
H.V.FUSE
HINGE UPPER
HINGE VOLT
HINGE VOLT
H.V.CAPACITOR
Loading...