Samsung AW180, AW240WB0K-CAP Operating Instructions

3. Installation and Operating Instructions

3-1 Installation

¡ When selecting the area for installing the unit, be sure to obtain approval of the customer.

1.Make sure that you install the unit in an area that provides good ventilation.

The air conditioner must not be blocked by any obstacle affecting the air flow near the air inlet and air outlet.

2.Make sure that you install the unit in an area which can endure the weight and vibration of the unit.

3.Make sure that you install the unit away from heat or vapor.

4.Make sure that you install the unit in an area where the cooled air can be evenly spread in a room.

5.Make sure that you install the unit in an area away from TVs, audio units, cordless phones, fluorescent lighting fixtures and other electrical appliances.(obtain a clearance of at least one meter)

6.Make sure that you install the unit in an area which provides easy drainage for condensed water.

7.Make sure that you install the unit in an area not exposed to rain or direct sunlight.

(Install a separate sunblind if exposed to direct sunlight.)

8.Do not install the unit in an area subjected to noise or vibration amplification which may affect your neighbor.

(Fix the unit firmly if mounted in a high place.)

Caution:

Do not use the air conditioner in such areas as a greasy area(including machine oil),

saline area(sea side), or sulphuric area(hot spring). When using the air conditioner in these areas, special maintenance is required. Contact your local dealer or our service center for advice.

Samsung Electronics

3-1

Samsung AW180, AW240WB0K-CAP Operating Instructions

3-2 Operating Instruction

Thermostat control

THERMOSTAT

OFF

hour

CONT.

 

 

TIMER

FAN SPEED

AIR SWING

Air swing switch

Timer control

Fan speed switch

3-2-1 Thermostat control

Off :

When the room temperature is lowered by the air conditioner, the gas within the thermostat will contract and cause a break in the electric contact.

The compressor will then stop.

After the compressor stops, the room temperature will rise.

On :

As the room temperature increases to a selected level, the gas within the thermostat expands, causing electric contact, which provides the source of electric power to the compressor. The room temperature will fall, and the cycle will repeat.

Control Operation :

By turning the control knob clockwise(toward higher numbers), the temperatures will be cooler. By turning the control knob counterclockwise(toward lower numbers), the temperature will be warmer.

Level 1 : Cool air will be supplied above 30~35¡ .

Cool air will be ceased below 28~32.5¡ .

Level 10 : Cool air will be supplied above 17.4~20.4¡ .

Cool air will be ceased below 14.4~17.4¡ .

3-2

Samsung Electronics

Loading...
+ 1 hidden pages