SAMSUNG ASH070VE0K_ANA.42313.1.16 Service Manual

SERVICE
Manual
INDOOR UNIT ASH070VE/D ASH090VE/D ASH120VE/D ASH071VE/D ASH091VE/D ASH121VE/D ASH074VE/D ASH094VE/D ASH124VE/D ASH075VE/D ASH095VE/D ASH125VE/D
OUTDOOR UNIT AXH070VE/D AXH090VE/D AXH120VE/D AXH071VE/D AXH091VE/D AXH121VE/D AXH074VE/D AXH094VE/D AXH124VE/D AXH075VE/D AXH095VE/D AXH125VE/D
CONTENTSAIR CONDITIONER
1. Pre c a u t i o n s
3. Operating Instructions and I n s t a l l a t i o n
4. Disassembly and Reassembly
5. Tro u b l e s h o o t i n g
6. Exploded Views and Parts List
7. Block Diagrams
8. PCB Diagrams
9. Wiring Diagrams
10. Schematic Diagrams
© Samsung Electronics Co., Ltd. FEB. 1997.
Printed in Korea. Code No. DB81-10122A(1)
1. Precautions
1 . Warning: Prior to re p a i r, disconnect the
power cord from the circuit bre a k e r.
2 . Use proper parts: Use only exact re p l a c e-
ment parts. (Also, we recommend re p l a c i n g parts rather than repairing them.)
3 . Use the proper tools: Use the proper tools
and test equipment, and know how to use them. Using defective tools or test equip­ment may cause problems later- i n t e r m i t t e n t contact, for example.
4 . Power Cord: Prior to re p a i r, check the
power cord and replace it if necessary.
5 . Avoid using an extension cord, and avoid
tapping into a power cord. This practice may result in malfunction or fire .
6 . After completing repairs and re a s s e m b l y,
check the insulation resistance. Pro c e d u re : Prior to applying power, measure the re s i s­tance between the power cord and the g round terminal. The resistance must be g reater than 30 megohms.
Fig. 1-1 Avoid Dangerous Contact
Fig. 1-2 No Tapping and No Extension Cords
7 . Make sure that the grounds are adequate.
8 . Make sure that the installation conditions
a re satisfactory. Relocate the unit if neces­s a r y.
9 . Keep children away from the unit while it is
being re p a i re d .
1 0 . Be sure to clean the unit and its surro u n d-
ing are a .
Fig. 1-3 No Kids Nearby!
Fig. 1-4 Clean the Unit
Samsung Electronics
1-1
M E M O
1-2
Samsung Electronics
2. Product Specifications
2-1 Table
Model
Item
Type -
Cooling BTU/h Dehumiditying I/h Heating BTU/h Low temp. heating BTU/h Air volume Cooling m3/min
Heating m3/min
Noise Cooling dB
Heating dB Energy Cooling BTU/h.W efficiency ratio Heating BTU/h.W Power V-Hz Power Cooling W Consumption Heating W operating Cooling A Current Heating A Power Cooling % factor Heating % Starting current A Power cord Length m
Number of core wire Fuse capacity A
Outer Width x Height mm dimension x Depth inch Weight kg Refrigerant pipe Liquid OD(mm)x L(m)
GAS Drain hose ID(mm)x L(m) Compressor Type
Motor Type
Rated output W
Blower Type
Motor Type
Rated output W
Heat exchanger Refrigerant control unit Freezer oil capacity Refrigerant to change(R-22) Protection device
Cooling test Condition Heating test Condition Maximum operation Condition
A S H 0 7 0 V E / A S H 0 7 1 V E / A S H 0 7 4 V E / A S H 0 7 5 V E
Indoor unit Outdoor unit
Wall-mounting
7000
1.2
7500
-
6.0
6.2 35 45 35 45
10.6
12.1
1-220 / 240-50
660 620
2.8
2.7
98.2
95.7
17.0
2 -
250V 10/16A
3.15 -
815x298x182 720x525x245
32.08x11.73x7.17 28.35x20.67x9.65
9.6 28 ø6.35 x 5 ø9.52 x 5
ø17 x 2000
- Rotary
- -
- 675
Cross-fan Propeller
Resin Die casting
35 20
2Row 12Step 1Row 20Step
CAPILLARY TUBE
280 690
- MST24AMN
-12008
A S H 0 9 0 V D / A S H 0 9 1 V D / A S H 0 9 4 V D / A S H 0 9 5 V D
Indoor unit Outdoor unit
Wall-mounting
7000
1.2
7500
-
6.0
6.2 35 45 35 45
10.6
11.7
1-200 / 220-50
660 640
3.3
3.2
90.9
90.9
17.0
2 -
250V 10/16A
3.15 -
185x298x182 720x525x245
32.08x11.73x7.17 28.35x20.67x9.65
9.6 28 ø6.35 x 5 ø9.52 x 5
ø17 x 2000
- Rotary
- -
- 675
Cross-fan Propeller
Resin Die casting
35 20
2Row 12Step 1Row 20Step
CAPILLARY TUBE
280 695
- MST24AMM
-12008
A S H 0 9 0 V E / A S H 0 9 1 V E / A S H 0 9 4 V E / A S H 0 9 5 V E
Indoor unit Outdoor unit
Wall-mounting
9000
1.6
10000
-
6.1
6.9 35 45 35 45
10.1
10.7
1-220 / 240-50
890 930
4.0
4.0
92.7
96.9
22.0
2 -
250V 10/16A
3.15 -
815x298x182 720x525x245
32.08x11.73x7.17 28.35x20.67x9.65
9.6 28 ø6.35 x 5 ø9.52 x 5
ø17 x 2000
- Rotary
- -
- 895
Cross-fan Propeller
Resin Steel
35 20
2Row 12Step 1Row 20Step
CAPILLARY TUBE
360 760
- MRA12037
-12007
A S H 0 9 0 V D / A S H 0 9 1 V D / A S H 0 9 4 V D / A S H 0 9 5 V D
Indoor unit Outdoor unit
Wall-mounting
9000
1.6
10000
-
6.1
6.9 35 45 35 45
10.1
10.7
1-220 / 220-50
890 930
4.2
4.2
96.3
99.9
22.0
2 -
250V 10/16A
3.15 -
185x298x182 720x525x245
32.08x11.73x7.17 28.35x20.67x9.65
9.6 28 ø6.35 x 5 ø9.52 x 5
ø17 x 2000
- Rotary
- -
- 890
Cross-fan Propeller
Resin Steel
35 20
2Row 12Step 1Row 20Step
CAPILLARY TUBE
360 820
- MRA12056
-12007
A S H 1 2 0 V E / A S H 1 2 1 V E / A S H 1 2 4 V E / A S H 1 2 5 V E
Indoor unit Outdoor unit
Wall-mounting
12000
1.9
13000
-
7.8
8.2 38 49 38 49
10.2
10.8
1-220 / 240-50
1180 1200
5.0
5.2
98.3
96.2
30.0
2 -
250V 10/16A
3.15 -
815x298x182 720x525x245
32.08x11.73x7.17 28.35x20.67x9.65
9.6 32 ø6.35 x 5 ø12.7 x 5
ø17 x 2000
- Rotary
- -
- 1210
Cross-fan Propeller
Resin Die casting
35 20
2Row 12Step 1Row 20Step
CAPILLARY TUBE
410 920
- MRA12030
-12008
A S H 1 2 0 V D / A S H 1 2 1 V D / A S H 1 2 4 V D / A S H 1 2 5 V D
Indoor unit Outdoor unit
Wall-mounting
12000
1.9
13000
-
7.8
8.2 38 49 38 49
9.83
10.4
1-200 / 220-50
1220 1250
5.9
6.1
94.0
93.1
36.0
2 -
250V 10/16A
3.15 -
185x298x182 720x525x245
32.08x11.73x7.17 28.35x20.67x9.65
9.6 32 ø6.35 x 5 ø12.7 x 5
ø17 x 2000
- Rotary
- -
- 1215
Cross-fan Propeller
Resin Steel
35 20
2Row 12Step 1Row 20Step
CAPILLARY TUBE
410 920
- MRA98706
-12008
Perfor­mance
Power
Size
INDOOR UNIT : DB27°C WB19°C OUTDOOR UNIT : DB35°C WB24°C INDOOR UNIT : DB20°C OUTDOOR UNIT : DB7°C WB 6°C INDOOR UNIT : DB32°C WB22.5°C OUTDOOR UNIT : DB43°C WB25.5°C
2-2 Dimensions
2-2-1 Indoor Unit
Air out
(Front view) (Remote control)
Air in
2-2-1 Outdoor Unit
(Rear view)
(Front view)
Installation plate
(Rear view)
2-2
Samsung Electronics
2-3 Low pressure & Current Data
Indoor Unit : A S H 0 7 0 V E / A S H 0 7 1 V E
Outdoor Unit : A X H 0 7 0 V E / A X H 0 7 1 V E
A S H 0 7 4 V E / A S H 0 7 5 V E
•Cooling characteristics •Heating characteristics
11 10
9 8 7 6 5 4 3
25
30 4035 45 50
Outdoor Inlet air D. B. temp.(°C)
11 10
9 8 7 6 5 4 3
-5
0 105 15 20 25
Outdoor Inlet air D. B. temp.(°C)
A X H 0 7 4 V E / A X H 0 7 5 V E
14 13 12 11 10
9 8 7 6 5 4 3
25
30 4035 45 50
Outdoor Inlet air D. B. temp.(°C)
32 30 28
26 24 22 20 18 16 14
12 10
-5
0 105 15 20 25
Outdoor Inlet air D. B. temp.(°C)
Samsung Electronics
2-3
Product Specifications
Indoor Unit : A S H 0 7 0 V D / A S H 0 7 1 V D
Outdoor : Unit A X H 0 7 0 V D / A X H 0 7 1 V D
A S H 0 7 4 V D / A S H 0 7 5 V D
•Cooling characteristics •Heating characteristics
11 10
9 8 7 6 5 4 3
25
30 4035 45 50
Outdoor Inlet air D. B. temp.(°C)
11 10
9 8 7 6 5 4 3
-5
0 105 15 20 25
Outdoor Inlet air D. B. temp.(°C)
A X H 0 7 4 V D / A X H 0 7 5 V D
14 13 12 11 10
9 8 7 6 5 4 3
25
30 4035 45 50
Outdoor Inlet air D. B. temp.(°C)
32 30 28
26 24 22 20 18 16 14
12 10
-5
0 105 15 20 25
Outdoor Inlet air D. B. temp.(°C)
2-4
Samsung Electronics
Product Specifications
Indoor Unit : A S H 0 9 0 V E / A S H 0 9 1 V E
Outdoor : Unit A X H 0 9 0 V D / A X H 0 9 1 V E
A S H 0 9 4 V E / A S H 0 9 5 V E
•Cooling characteristics •Heating characteristics
11 10
9 8 7
6
5 4 3
25
30 4035 45 50
Outdoor Inlet air D. B. temp.(°C)
11 10
9 8 7 6 5 4 3
-5
0 105 15 20 25
Outdoor Inlet air D. B. temp.(°C)
A X H 0 9 4 V D / A X H 0 9 5 V E
14 13 12 11 10
9
8
7 6 5 4
3
25
30 4035 45 50
Outdoor Inlet air D. B. temp.(°C)
32 30 28
26 24 22 20 18 16 14
12 10
-5
0 105 15 20 25
Outdoor Inlet air D. B. temp.(°C)
Samsung Electronics
2-5
Product Specifications
Indoor Unit : A S H 0 9 0 V D / A S H 0 9 1 V D
Outdoor Unit : A X H 0 9 0 V D / A X H 0 9 1 V D
A S H 0 9 4 V D / A S H 0 9 5 V D
•Cooling characteristics •Heating characteristics
11 10
9 8 7 6 5 4 3
25
30 4035 45 50
Outdoor Inlet air D. B. temp.(°C)
11 10
9 8 7 6 5 4 3
-5
0 105 15 20 25
Outdoor Inlet air D. B. temp.(°C)
A X H 0 9 4 V D / A X H 0 9 5 V D
14 13 12 11 10
9 8 7 6 5 4 3
25
30 4035 45 50
Outdoor Inlet air D. B. temp.(°C)
32 30 28
26 24 22 20 18 16 14
12 10
-5
0 105 15 20 25
Outdoor Inlet air D. B. temp.(°C)
2-6
Samsung Electronics
Product Specifications
Indoor Unit : A S H 1 2 0 V E / A S H 1 2 1 V E
Outdoor Unit : A X H 1 2 0 V E / A X H 1 2 1 V E
A S H 1 2 4 V E / A S H 1 2 5 V E
•Cooling characteristics •Heating characteristics
11 10
9 8 7
6
5 4 3
25
30 4035 45 50
Outdoor Inlet air D. B. temp.(°C)
11 10
9 8 7 6 5 4 3
-5
0 105 15 20 25
Outdoor Inlet air D. B. temp.(°C)
A X H 1 2 4 V E / A X H 1 2 5 V E
14 13 12 11 10
9
8
7 6 5 4
3
25
30 4035 45 50
Outdoor Inlet air D. B. temp.(°C)
32 30 28
26 24 22 20 18 16 14
12 10
-5
0 105 15 20 25
Outdoor Inlet air D. B. temp.(°C)
Samsung Electronics
2-7
Product Specifications
Indoor Unit : A S H 1 2 0 V D / A S H 1 2 1 V D
Outdoor Unit : A X H 1 2 0 V D / A X H 1 2 1 V D
A S H 1 2 4 V D / A S H 1 2 5 V D
•Cooling characteristics •Heating characteristics
11 10
9 8 7 6 5 4 3
25
30 4035 45 50
Outdoor Inlet air D. B. temp.(°C)
11 10
9 8 7 6 5 4 3
-5
0 105 15 20 25
Outdoor Inlet air D. B. temp.(°C)
A X H 1 2 4 V D / A X H 1 2 5 V D
14 13 12 11 10
9 8 7 6 5 4 3
25
30 4035 45 50
Outdoor Inlet air D. B. temp.(°C)
32 30 28
26 24 22 20 18 16 14
12 10
-5
0 105 15 20 25
Outdoor Inlet air D. B. temp.(°C)
2-8
Samsung Electronics
2-4 Refrigerating Cycle Block Diagram
INDOOR UNIT
Heat exchanger (Evaporator)
OUTDOOR UNIT
Capillary tube
T
Liquid side
T
Gas side
2-way valve
3-way valve
Check valve
Capillary tube
Compressor
Heat exchanger (Condenser)
4-way valve
Cooling Heating Gas leak check point
Samsung Electronics
2-9
3. Operating Instructions and Installation
3-1 Operating Instructions
3-1-1 Name & Function of Key in remote controller
NO
NAMED OF KEY 1 2
3
MODE
4 5
6
7
8
TURBO
OFF
(UP)
(DOWN)
On/Off Button. Use this button to start and stop air conditioner. Temp. up button. If the button is pressed once,
the setting temperature is increased by 1°C Temp. up button. If the button is pressed once,
the setting temperature is decreased by 1°C Each time you press this button,
MODE is changed in the following order.
Use this button to provide heavy duty cooling & Heating for 30 minutes. Set up the reserve or cancel the timer on and timer off quickly
Use this button for sleep operation. (The SLEEP mode can be selected at COOL and HEAT mode.)
Adjusts air flow vertically. Each time you press this button, BLADE-H rotates by 10.58° (Changable range 42.3°)
Each time you press this button, FAN SPEED is changed in the following order.
FUNCTION OF KEY
10 11
12 13
14
15
3-1
9
C O V E R
T
I
M
E R
ON TIMER OFF TIMER
SET CANCEL
(UP)
(DOWN)
TIME
Set up the time that operation start. Set up the time that operation stop.
Use this button to reserve the timer on. Use this button to reserve or cancel the timer on and timer off.
If the button is pressed once, the time increase by one minute during the time set mode, and ten minutes during the timer set mode.
If the button is pressed once, the time decrease by one minute during the time set mode, and ten minutes during the timer set mode.
Without regard to ON/OFF condition in remote controller, use this button to set current time. Adjust the current time using button. (Data can be transmitted after setting up the time)
Samsung Electronics
3-1-1 Name & Function of Key in remote controller
Operating Instructions and Installation
1. A U TO MODE : In this mode, operation mode(COOL, HEAT, DRY) is selected auto­matically by the room temperature of initial o p e r a t i o n .
Room Temp Tr 21°C+T 21°C +T>Tr
T= -1°, -2°C, 0°C+1°C+2°CT is controlled by setting temperature
up/down key of remote contro l l e r
2. C O O L MODE : The unit operates accord i n g to the diff e rence between the setting and room temperature. (18°C~30°C)
3. H E AT MODE : The unit operates accord i n g to the diff e rence between the setting and room temperature.(16°C~30°C) * P revention against cold wind : For about 3~5 minutes after initial operation, thermo c o n t rol or “de-ice”, the indoor fan will either not operate or operate very slow­ly(510 rpm), then switch to the selected fan speed. This period is to allow the indoor unit's heat-exchanger to prewarm before emitting warm air. *High temperature release function : The outdoor unit for and compressor ON/OFF c o n t rol for safety operation, when the over­heat is heat exchanger of indoor unit. *De-ice : Deicing operation is controlled by indoor unit's heat exchanger temperature and accumulating time of compre s s o r ' s o p e r a t i o n . De-ice end by sensing of the pro c e s s i n g time by de-ice Condition.
Cool Operation (Set Temp:AUTO SETTING)
Heat Operation (Set Temp : 22°C+T)
Operation Type
4. D RY MODE : Has 3 states, each determined by room temperature . The unit operates in DRY m o d e . *Co m p ressor ON/OFF Time is contro l l e d compulsorily(can not set up the fan speed, always bre e z e ) . * P rotective function : Low temperature release. (Prevention against fre e z e )
5. TURBO MODE : This mode is available in A U TO, COOL, HEAT, DRY, FAN MODE. When this button is pressed at first, the air conditioner is operated “powerful” state for 30 minutes re g a rdless of the set tempera­t u re, room temperature . When this button is pressed again, or when the operating time is 30 minutes, turbo operation mode is canceled and returned to the previous mode. *But, if you press the TURBO button in DRY or FAN mode that is changed with A U TO mode automatically.
6 . S L E E P MODE : Sleep mode is available
only in COOL or HEAT mode. The operation will stop after 6 hours. *In COOL mode : The setting temperature is automatically raised by 1°C each 1hour When the temperature has been raised by total of 2°C, that temperature is main­t a i n e d . *In HEAT mode : The setting temperature is automatically droped by 1°C each 1hour. When the temperature has been droped by total of 2°C, that temperature is main­t a i n e d .
7. FAN SPEED : Manual (3 step), Auto (4 step) Fan speed automatically varies depending on both the diff e rence between setting and the room temperature .
Samsung Electronics
3-2
Operating Instructions and Installation
8 . C O M P U L S O RY O P E R ATION :
For operating the air conditioner without the remote contro l l e r. * A U TO : The operating is the same func­tion that A U TO MODE in the remote con­t ro l l e r.
9 . SWING : BLADE-H is rotated vertically by
the stepping motor. *Memory louver : When ON/OFF button is p ressed at stop state, the BLADE-H re t u r n s to its original location which is operating state before stop *Swing auto : The BLADE-H can ro t a t e within about 10,500 in the original position set by the SWING SET button. *Swing Set : Press the button under the remote control is displayed on LCD the , and the blades move up and down, about 43°. If the one more time press the button, bla­tles location is stop.
1 0 . Quick OFF TIMER: OFF timer (quick timer)
allows reservation or cancel the timer on and timer off quickly When OFF timer button is pressed at oper­ating state, LCD displays the polling state s e q u e n t i a l l y. The LCD also displays the time re m a i n i n g .
11 . 24-Hour ON/OFF Real Setting Ti m e r. : The
air conditioner is turned ON at a specified time using .
ON TIMER
OFF TIMER : The air Conditioner is turned OFF at a specified time using .
OFF TIMER
*ON TIMER : Only timer LED lights on. *OFF TIMER : Both timer and operation LED lights on. *3 minutes delay timer.
1 4 . SELF Diagnosis
LED DISPLAY
o p e r-
T I M E R
a t i o n
FA N
Tu r b o
Check Point
I n t e r ruption of electric power and Power on. Abnormal condition of the room sensor. Abnormal condition of the indoor unit's heat exchanger sensor. Indoor unit fan motor lock.
L E D
:
b l i n k i n g
: LED off
1 5 . TIME SHORTENING : If the "Time short"
connector pin is shorted on the main P. C. B, the compressor's three minutes delay func­tion is cancelled, and each operation time is shortened to one fiftieth of its original time.
1 6 . BUZZER SOUND : Whenever the ON/OFF
button is pressed or whenever change occurs to the condition which is set up or select, the compulsory operation mode, buzzer is sounded "beep"
3-3
Samsung Electronics
3-2 Installation
3-2-1 Selecting Area for Installation
Select an area for installation that is suitable to the customer's needs.
3-2-1(a) Indoor Unit
1 . Make sure that you install the indoor unit in
an area providing good ventilation. It must not be blocked by an obstacle affecting the airflow near the air inlet and the air outlet.
2 . Make sure that you install the indoor unit in
an area allowing good air handling and endurance of vibration of the indoor unit.
3. Make sure that you install the indoor unit in an area where there is no source of heat or vapor nearby.
4 . Make sure that you install the indoor unit in
an area from which hot or cool air is spre a d evenly in a ro o m .
5 . Make sure that you install the indoor unit in
an area away from TVs, audio units, cord­less phones, fluorescent lighting fixture s and other electrical appliances (at least 1 m e t e r ) .
6 . Make sure that you install the indoor unit in
an area which provides easy pipe connec­tion with the outdoor unit, and easy drainage for condensed water.
(Fix the unit firmly if it is mounted in a
high place.)
3 . Make sure that you install the outdoor unit
in area providing good ventilation and which is not dusty. It must not be blocked by any obstacle affecting the airflow near the air inlet and the air outlet.
4 . Make sure that you install the outdoor unit
in area free from animals or plants.
5 . Make sure that you install the outdoor unit
in area not blocking the traff i c .
6. Make sure that you install the outdoor unit in area easy to drain condensed water fro m the indoor unit.
7. Make sure that you install the outdoor unit in area which provides easy connection within the maximum allowable length of a coolant pipe(15 meters).
Note
1. Add 10 grams of refrigerant (R-22) for every 1 meter if the pipe length exceeds the standard pipe length of 5 meters.
2. Maintain a height between the indoor and outdoor units of less than 3 meters.
8 . Make sure that you install the outdoor unit
in an area which is large enough to accom­modate the measurements
shown in figure on the next page.
7. Make sure that you install the indoor unit in an area which is large enough to accomo­date the measurements shown in figure on the next page.
3-2-1(b) Outdoor Unit 1 . Make sure that you install the outdoor unit
in area not exposed to the rain or direct sun l i g h t .
(Install a separate sunblind if exposed to
d i rect sun light.)
2 . Make sure that you install the outdoor unit
in area allowing good air moment, not amplifying noise or vibration, especially to avoid disturbing neighbours.
Caution :
It is harmful to the air conditioner if it is used in the following environments: greasy areas (including areas near machines), salty areas such as coast areas, areas where sulfuric gas is present such as hot spring areas. Contact your dealer for advice.
Samsung Electronics
3-2-1(c) Remote Control Unit 1 . Make sure that you install the remote con-
t rol unit in an area free from obstacles such as curtains etc, which may block signals f rom the remote control unit.
2. Make sure that you install the remote con­t rol unit in an area not exposed to d i rect sunlight, and where there is no sourc e of heat.
3. Make sure that you install the remote con­t rol unit in an area away from TVs, audio units, cordless phones, fluorescent lighting f i x t u res and other electrical appliances (at least 1 meter).
3-4
Operating Instructions and Installation
3-2-2 Installation diagram of indoor unit and outdoor unit
A Indoor unit gas leak test check point
Indoor unit
Piping
1
3
2
Tape vinyl
B Drain hose installation
Cut the piping hole sloped slightly
5 6
250mm or more
Piping may be laid to the rear, left, right or down .
Right
Rear
Down
Rear
200mm or more
Left
3-5
Remote control
Remote control holder
4
10
1
2 3 4 5
Piping (Liquid) 1/4" Clamper tube
7K/9K BTU Piping(Gas)3/8” 12K BTU Piping(Gas)1/2”
Installation tube Pipe-connection Vinyl tape Screw Putty Drain hose
6 7 8 9
10
Installation plate
Samsung Electronics
3-2-2(a) Fixing the Installation Plate
Operating Instructions and Installation
(Unit : mm)
(Unit : mm)
Installation plate
280
340
Pipe hole (ø65mm)
1. Determine the position of the pipe and drain hose hole using the right figure and drill the hole with an inner diameter of 65mm so that it slants slightly downwards.
2. If you are fixing the indoor unit to a… Then follow Steps…
Wall 3.
Window frame 4 to 6.
3. Fix the installation plate to the wall in a manner appro­priate to the weight of the indoor unit.
If you are mounting the plate on a concrete wall with anchor bolts, the anchor bolts must not project by more than 20mm.
4. Determine the positions of the wooden uprights to be attached to the window frame.
3-2-2(b) Purging the Unit
5. Attach the wooden uprights to the window frame in a manner appropriate to the weight of the indoor unit.
6. Using tapped screws, attach the installation plate to the wooden uprights, as illustrated in the last figure oppo­site.
On delivery, the indoor unit is loaded with an inert gas. All this gas must therefore be purged before connecting the assembly piping. To purge the inert gas, proceed as fol ­lows.
Unscrew the caps at the end of each pipe.
Result : All inert gas escapes from the indoor unit.
To prevent dirt or foreign objects from getting into
the pipes during installation, do NOT remove the caps completely until you are ready to connect the piping.
Samsung Electronics
3-6
Loading...
+ 42 hidden pages