Samsung AR09KSFPDWQN, AR**KSFP** series User Manual

QUESTIONS OR COMMENTS?
COUNTRY CALL OR VISIT US ONLINE AT
U.S.A
- Consumer Electronics
- Mobile Phones
1-800-SAMSUNG (726-7864)
www.samsung.com/us/support
CANADA 1-800-SAMSUNG(726-7864)
www.samsung.com/ca/support (English)
www.samsung.com/ca_fr/support (French)
Air conditioner
User manual
AR77KSFP77
ŷ Thank you for purchasing this Samsung air conditioner. ŷ Before operating this unit, please read this user manual carefully and retain it for future reference.
2 English
Contents
Safety Information 4
Safety Information 4
At a Glance 12
Indoor Unit Overview 12
Display
Remote Control Overview 13
Inserting batteries
Remote Control Operation 14
2SHUDWLRQPRGHVŷ&RQWUROOLQJWHPSHUDWXUHŷ &RQWUROOLQJIDQVSHHGŷ&RQWUROOLQJDLUIORZGLUHFWLRQ
Power Smart Features 16
Cooling Operation 16
&RROPRGHŷ6WHSFRROLQJIXQFWLRQ
Dehumidifying Operation 17
Dry mode
Air Purifying Operation 17
Virus doctor function
Heating Operation 18
Heat mode
Quick Smart Features 19
$XWRPRGHŷ)DQPRGHŷ)DVWIXQFWLRQŷ&RPIRUWIXQFWLRQŷ
%HHSVRXQGIXQFWLRQŷ4XLHWIXQFWLRQŷ
Energy-Saving Features 22
Energy-Saving Operation 23
6LQJOHXVHUIXQFWLRQŷ7LPHGRQ7LPHGRIIIXQFWLRQŷJRRGŰVOHHSIXQFWLRQ
Cleaning and Maintenance 25
Cleaning at a Glance 25
Troubleshooting 27
3English
Installation 31
Safety Information on Installation 31
Preparation 33
Step 1.1 Choosing the installation location Step 1.2 Checking and preparing accessories and tools Step 1.3 Drilling a hole through the wall Step 1.4 Taping the pipes, cables, and drain hose
Indoor Unit Installation 37
Step 2.1 Connecting the power and communication cables (assembly cable) Step 2.2 Optional: Extending the power cable Step 2.3 Installing and connecting the drain hose Step 2.4 Optional: Extending the drain hose Step 2.5 Optional: Changing the direction of the drain hose Step 2.6 Installing and connecting the assembly pipes to the refrigerant pipes (assembly pipe) Step 2.7 Shortening or extending the refrigerant pipes (assembly pipe) Step 2.8 Fixing the installation plate
Outdoor Unit Installation 44
Step 3.1 Fixing the outdoor unit in place Step 3.2 Connecting the power and communication cables and the refrigerant pipes Step 3.3 Evacuating the air Step 3.4 Adding refrigerant Step 3.5 Important information regulation regarding the refrigerant used
Installation Inspection 48
Step 4.1 Performing the gas leak tests Step 4.2 Performing final check and trial operation
Sub PCB installation(optional) 50
Wired remote controller installation (optional) 51
4 English
Safety Information
Safety Information
Safety Information
WARNING
State of California Proposition 65 Warning (US only) This product contains chemicals known to the State of California to
cause cancer and birth defects or other reproductive harm.
Before using your new air conditioner, please read this manual thoroughly to ensure that you know how to safely and efficiently operate the extensive features and functions of your new appliance.
Because the following operating instructions cover various models, the characteristics of your air conditioner may differ slightly from those described in this manual. If you have any questions, call your nearest contact centre or find help and information online at www. samsung.com.
WARNING
Hazards or unsafe practices that may result in severe personal injury or death.
CAUTION
Hazards or unsafe practices that may result in minor personal injury or property damage.
Follow directions. Do NOT attempt. Make sure the machine is grounded to prevent electric shock. Cut off the power supply. Do NOT disassemble.
FOR INSTALLATION
WARNING
5English
Safety InformationSafety Information
Use a power cord with this product's power specifications
or higher and use the power cord for this appliance only. In addition, do not use an extension cord.
ŷ Extending the power cord may result in electric shock or fire. ŷ Do not use an electric transformer. This may result in electric
shock or fire.
ŷ If the voltage/frequency/rated current condition is different,
it may cause fire.
The installation of this appliance must be performed by a
qualified technician or service company.
ŷ Failing to do so may result in electric shock, fire, explosion,
problems with the product, or injury and may also void warranty on the installed product.
Install an Isolation Switch next to the Air Conditioner (but
not on the panels of the Air Conditioner) and circuit breaker dedicated to the air conditioner.
ŷ Failing to do so may result in electric shock or fire.
Fix the outdoor unit firmly so that the electric part of the outdoor unit is not exposed.
ŷ Failing to do so may result in electric shock, fire, explosion,
or problems with the product.
Do not install this appliance near a heater, or inflammable material. Do not install this appliance in a humid, oily or dusty location, in a location exposed to direct sunlight and water (or rain). Do not install this appliance in a location where gas may leak.
ŷ This may result in electric shock or fire.
Never install the outdoor unit in a location such as on a high
external wall where it could fall.
ŷ If the outdoor unit falls, it may result in injury, death or
6 English
Safety Information
Safety Information
property damage.
This appliance must be properly grounded. Do not ground the
appliance to a gas pipe, plastic water pipe, or telephone line.
ŷ Failing to do so may result in electric shock, fire, and
explosion.
ŷ Make sure to use a socket-outlet with ground.
CAUTION
Please cover the air conditioner with PE BAG after installation,
and remove it when you start to run air conditioner.
Install your appliance on a level and hard floor that can
support its weight.
ŷ Failing to do so may result in abnormal vibrations, noise, or
problems with the product.
Install the drain hose properly so that water drains correctly.
ŷ Failing to do so may result in water overflowing and
property damage. Avoid adding drain to waste pipes as odours may arise in the future.
When installing the outdoor unit, make sure to connect the
drain hose so that draining is performed correctly.
ŷ The water generated during heating by the outdoor unit may
overflow and result in property damage. In particular, in winter, if a block of ice falls, it may result in injury, death or property damage.
FOR POWER SUPPLY
WARNING
When the circuit breaker is damaged, contact your nearest
service centre.
7English
Safety InformationSafety Information
Do not pull or excessively bend the power line. Do not twist
or tie the power line. Do not hook the power line over a metal object, place a heavy object on the power line, insert the power line between objects, or push the power line into the space behind the appliance.
ŷ This may result in electric shock or fire.
CAUTION
When not using the air conditioner for a long period of time or
during a thunder/lightning storm, cut the power at the circuit breaker.
ŷ Failing to do so may result in electric shock or fire.
FOR USING
WARNING
If the appliance is flooded, please contact your nearest service
centre.
ŷ Failing to do so may result in electric shock or fire.
If the appliance generates a strange noise, a burning smell or
smoke, cut off the power supply immediately and contact the nearest service centre.
ŷ Failing to do so may result in electric shock or fire.
In the event of a gas leak (such as propane gas, LP gas, etc.),
ventilate immediately without touching the power line. Do not touch the appliance or power line.
ŷ Do not use a ventilating fan. ŷ A spark may result in an explosion or fire.
To reinstall the air conditioner, please contact your nearest
service centre.
8 English
Safety Information
Safety Information
ŷ Failing to do so may result in problems with the product,
water leakage, electric shock, or fire.
ŷ Delivery service for the product is not provided. If you
reinstall the product in another location, additional construction expenses and an installation fee will be charged.
ŷ Especially, when you wish to install the product in an
unusual location such as in an industrial area or near the seaside where it is exposed to salt in the air, please contact your nearest service centre.
Do not touch the circuit breaker with wet hands.
ŷ This may result in electric shock.
Do not turn the air conditioner off with the circuit breaker
while it is operating.
ŷ Turning the air conditioner off and then on again with the
circuit breaker may cause a spark and result in electric shock or fire.
After unpacking the air conditioner, keep all packaging
materials well out of the reach of children, as packaging materials can be dangerous to children.
ŷ If a child places a bag over its head, it may result in
suffocation.
Do not touch the air flow blade with your hands or fingers
during heating.
ŷ This may result in electric shock or burns.
Do not insert your fingers or foreign substances into the air
inlet/outlet of the air conditioner.
ŷ Take special care that children do not injure themselves by
inserting their fingers into the product.
Do not strike or pull the air conditioner with excessive force.
9English
Safety InformationSafety Information
ŷ This may result in fire, injury, or problems with the product.
Do not place an object near the outdoor unit that allows
children to climb onto the machine.
ŷ This may result in children seriously injuring themselves.
Do not use this air conditioner for long periods of time in badly
ventilated locations or near infirm people.
ŷ Since this may be dangerous due to a lack of oxygen, open a
window at least once an hour.
If any foreign substance such as water has entered the
appliance, cut off the power supply and contact the nearest service centre.
ŷ Failing to do so may result in electric shock or fire.
Do not attempt to repair, disassemble, or modify the appliance
yourself.
ŷ Do not use any fuse (such as cooper, steel wire, etc.) other
than the standard fuse.
ŷ Failing to do so may result in electric shock, fire, problems
with the product, or injury.
CAUTION
Do not place objects or devices under the indoor unit.
ŷ Water dripping from the indoor unit may result in fire or
property damage.
Check that the installation frame of the outdoor unit is not
broken at least once a year.
ŷ Failing to do so may result in injury, death or property
damage.
Max current is measured according to IEC standard for safety
and current is measured according to ISO standard for energy
10 English
Safety Information
Safety Information
efficiency.
Do not stand on top of the appliance or place objects (such as
laundry, lighted candles, lighted cigarettes, dishes, chemicals, metal objects, etc.) on the appliance.
ŷ This may result in electric shock, fire, problems with the
product, or injury.
Do not operate the appliance with wet hands.
ŷ This may result in electric shock.
Do not spray volatile material such as insecticide onto the
surface of the appliance.
ŷ As well as being harmful to humans, it may also result in
electric shock, fire or problems with the product.
Do not drink the water from the air conditioner.
ŷ The water may be harmful to humans.
Do not apply a strong impact to the remote control and do not
disassemble the remote control.
Do not touch the pipes connected with the product.
ŷ This may result in burns or injury.
Do not use this air conditioner to preserve precision
equipment, food, animals, plants or cosmetics, or for any other unusual purposes.
ŷ This may result in property damage.
Avoid directly exposing humans, animals or plants to the air
flow from the air conditioner for long periods of time.
ŷ This may result in harm to humans, animals or plants.
This appliance is not intended for use by persons (including
children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, without supervision
11English
Safety InformationSafety Information
or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
FOR CLEANING
WARNING
Do not clean the appliance by spraying water directly onto it.
Do not use benzene, thinner or alcohol to clean the appliance.
ŷ This may result in discolouration, deformation, damage,
electric shock or fire.
Before cleaning or performing maintenance, cut off the
power supply and wait until the fan stops.
ŷ Failing to do so may result in electric shock or fire.
CAUTION
Take care when cleaning the surface of the heat exchanger of
the outdoor unit since it has sharp edges.
ŷ This should be done by a qualified technician. Please
contact your installer or service centre.
Do not clean the inside of the air conditioner by yourself.
ŷ For cleaning inside the appliance, contact your nearest
service centre.
ŷ When cleaning the filter, refer to the descriptions in the
ů&OHDQLQJDWD*ODQFHŰVHFWLRQ
ŷ Failing to do so may result in damage, electric shock or fire.
12 English
At a Glance
The actual product may differ slightly from the image depicted below.
Indoor Unit Overview
03
04
01
02
06
07
05
01 Air intake
02 Air filter
03 Air flow blade (up and down)
04 Air flow blade (left and right)
05 Room temperature sensor
06 Display
07 Power button /
Remote control receiver
Display
01
02
03
04
05
01 good'sleep indicator
02 Timer indicator
Auto clean indicator
03 Operation indicator
04 Power button
05 Remote controller receiver
13English
At a Glance
Remote Control Overview
01 Set temperature indicator
02 Timer option indicator
03 Operation mode indicator
04 Options indicator
05 Low battery indicator
06 Transmit indicator
07 Fan speed indicator
08 Vertical air swing indicator
09 Horizontal air swing indicator (Without this
function)
10 Settings indicator
11 Power button
12 Temperature button
13 Options button
14 Timer button
15 Direction button / Selection button
16 Vertical air swing button
17 Mode button
18 Fan speed button
19 Horizontal air swing button(Without this
function)
20 Settings button
21 SET button
NOTE
ŷ The descriptions in this manual are primarily
made based on the remote control buttons.
ŷ Although Virus Doctor(
)/d'light Cool /
Usage / Filter Reset / Display / Horizontal air swing indicator is displayed on the
remote control display, it is not available on this model.
01
05
06
07
08
10
09
16
17
18
20
21
02
03
04
11
12
13
19
14
15
Inserting batteries
two 1.5V AAA type batteries
14 English
At a Glance
Operation modes
You can change the current mode between Auto, Cool, Dry, Fan, and Heat by pressing the
button.
Controlling temperature
You can control the temperature in each mode as follows:
Mode Temperature control
Auto/Cool/
Heat
Adjust by 1 °F between 61°F and 86°F(16°C and 30°C)
Dry
Adjust by 1 °F between 65°F and 86°F(18°C and 30°C)
Fan You cannot control the temperature.
NOTE
You can use the Cool, Dry, and Heat modes in the following conditions:
Mode Cool Dry Heat
Indoor
temperature
61˚F to 90˚F
(16 °C to 32 °C)
65˚F to 90˚F
(18 °C to 32 °C)
81°F(27 °C)
or less
Outdoor
temperature
14°F to 114°F
(-10 °C to 46 °C)
14°F to 114°F
(-10 °C to 46 °C)
5°F to 75°F
(-15 °C to 24 °C)
Indoor
humidity
80% or less
relative
humidity
__
ŷ If the air conditioner operates in a high humidity
environment in the Cool mode for an extended period of time, condensation may occur.
ŷ If the outdoor temperature drops to 23°F(-5°C), the heating
capacity may decrease to as much as 60% to 70% of the specified capacity.
You can use the air conditioner easily by selecting a mode and then by controlling the temperature, fan speed, and air direction.
Remote Control Operation
15English
At a Glance
Controlling fan speed
You can select the following fan speeds in each mode:
Mode Available fan speeds
Auto/Dry
(Auto)
Cool/Heat
(Auto), (Low), (Med), (High),
(Turbo)
Fan
(Low), (Med), (High), (Turbo)
Controlling air flow direction
Keep the vertical air flow in a constant direction by stopping the movements of the vertical air flow blade.
In operation
Ź
NOTE
ŷ If you adjust the vertical air flow blade manually, it may
not close completely when you turn off the air conditioner.
ŷ You can control the vertical air flow direction when the
good'sleep function is running while in the Heat mode, but not while in the Cool mode.
Horizontal air flow (manual)
Keep the horizontal air flow in a constant direction by changing the directions of the horizontal air flow blades manually.
CAUTION
ŷ To prevent personal injury, make sure
that you change the directions of the horizontal air flow blades after stopping the movements of the vertical air flow blade.
Loading...
+ 36 hidden pages