Samsung AM20, AM14, AM14A1E2-XEH Block Diagram

7. Block Diagrams
7-1 Micro Computer Block Diagram
HEAT EXCHANGER SENSOR
ROOM TEMPERATURE SENSOR
INFRARED SIGNAL
REMOTE CONTROLLER
POWER ON/OFF
MODE (AUTO, COOL, DRY, FAN
TURBO
INDOOR CONTROL PANEL
RESET CIRCUIT
OSCILLATION CIRCUIT
MODE SELECT SWITCH
COMPRESSOR CONTROL
• SIGNAL
STEPPING MOTOR CONTROL SIGNAL
BUZZER CONTROL SIGNAL
•BLADE-H CONTROL
•INDOOR FAN MOTOR CONTROL
•COMPRESSOR CONTROL
•TEMPERATURE CONTROL
•TIMER
•BUZZER CONTROL
TRIGER SIGNAL
SSR
INDOOR FAN MOTOR SPEED DETECT
ZERO CROSSING
*
INDICATOR PANNEL OPERATION LED
TIMER LED FAN ONLY LED
INDOOR FAN MOTOR
FAN SPEED SELECT
BLADE-H MOVING SELECT
ON, OFF TIMER SELECT
TEMPERATURE SELECT
SLEEP SELECT
TIME SETTING
AC INPUT
POWER TRANSFORMER
COMPRESSOR DRIVE STEPPING MOTOR
DRIVE BUZZER DRIVE
DC 5V DC 12V
VOLTAGE REGULATOR
COMPRESSOR
STEPPING MOTOR
BUZZER
Samsung Electronics
7-1
Block Diagrams
7-2 Outdoor Unit Control Diagram (IC-TYPE)
AC240V
50Hz
Room “C”
Input
Room “B”
Input
Power input
Load control
(SV-BY, SV-B, SV-C,
compressor)
Indoor unit
Room B, and
room C sensor
250V 3.15A
Power trans and
rectification
circuit
Indoor unit
room 1 and
room 2 motor
sensor
SV-BY
Delay circuit
Simultaneous
controller.
SV-B, SV-C
Compressor
delay
circuit
DC power
circuit
SV-BY
driver
Compressor
motor
7-2
SV-C
sensor
SV-B
Sensor
SV-C
driver
SV-B
driver
Samsung Electronics
Loading...
+ 1 hidden pages