Assembly, commissioning and operation of the device may only be per-
formed by trained and experienced personnel familiar with this product.
According to these mounting and operating instructions, trained personnel
is referred to persons who are able to judge the work they are assigned to
and recognize possible dangers due to their specialized training, their
knowledge and experience as well as their knowledge of the relevant
standards.
Explosion-protected versions of this device may only be operated by per-
sonnel who have undergone special training or instructions or who are
authorized to work on explosion-protected devices in hazardous areas.
See section 9 for more details.
Any hazards which could be caused by the process medium and the oper-
ating pressure in the instrument are to be prevented by means of appropriate measures.
Make sure that the instrument is only used where temperatures and operating pressure do not exceed the sizing data specified in the order.
The Media 6 Differential Pressure Meter is not certified for measuring
flammable gases or liquids in Zone 0 areas.
Proper shipping and appropriate storage are assumed.
Note! Devices with the CE mark meet the requirements specified in the
Directive 94/9/EC and the Directive 89/336/EEC.
The Declaration of Conformity can be viewed and downloaded on the Internet at http://www.samson.de.
EB 9527-1 EN
3
Modifications in device firmware compared to the previous version
Previous versionNew version
A 2.03 / B 2.03A 2.10 / B 2.10
Limit switchesThe limit switches A1 and A2 are configured over software as
minimum and maximum alarms.
They can be adjusted separately over the keys on the device.
Filling limit during operation
The filling limit during operation UCW can be set over the keys
on the device independently of the limit switches
A 2.10 / B 2.10A 2.11 / B 2.11
Error codeThe current output of the Media 6 device is switched to
≥ 3.6 mA
4
EB 9527-1 EN
Previous versionNew version
EB 9527-1 EN
5
Design and principle of operation
1 Design and principle of operation
The Media 6 Differential Pressure Meters
measure and indicate the differential pressure or measured variables derived from
the differential pressure. They are designed
for gases and liquids, for example, for liquid level measurement in pressurized
vessels.
The measuring device consists of a dp cell
and an indicating unit. The cell has a
measuring diaphragm and measuring
springs designed for a certain measuring
span, and the indicating unit is equipped
with either an LCD (liquid crystal display) or
an LED (light-emitting diode) to indicate
important operating conditions.
The differential pressure ∆p = p
on the measuring diaphragm (1.1) which is
counterbalanced by the measuring springs
(1.2). The movement made by the measuring diaphragm and lever (1.3) which is proportional to the differential pressure is led
by the elastic disc (1.4) out of the pressure
chamber and converted by the displacement sensor (2) into an electric signal.
This signal is compared with the data stored
in the EEPROM (4) and processed in the
microprocessor (3) which controls both the
display (7, LCD or LED) and the D/A converter (9) for the output signal which is issued at connector A as a two-wire 4 to
20 mA transmitter signal.
– p2 acts
1
The SERIAL INTERFACE (10) enables the
device to be configured using a special
memory pen or a connecting cable and a
PC with SAMSON’s TROVIS-VIEW Configuration and Operator Interface.
The user-specific data is saved in the
EEPROM (4). Data can also be saved in this
manner and kept until it is overwritten
again. The operating data of Media 6 can
also be uploaded to the memory pen and
downloaded to the device on site.
The memory pen can be programmed on a
PC with the corresponding TROVIS-VIEW
software, using the operating data, e.g.
type of gas, gas density, tank design and
position of the limit switches. This data is
used to convert the differential pressure into
a value proportional to the tank contents
then used to display and issue the direct current signal from 4 to 20 mA.
Four types of gas and various write protection functions for stored data can be selected using the DIL switches (6).
Several operating functions (zero and span
calibration, filling limit during operation,
limit switches and test function settings, etc.)
as well as operating status (load/save operating values) can be set using three keys (5).
6
EB 9527-1 EN
Design and principle of operation
Indicating unit with LCD or LED
9
7
#
40
60
Connector A
= 12 to 36 V DC
U
B
= 4 to 20 mA
I
A
2
1.1
1.2
6
20
m3
0
5
3
%
µP
100
80
EEPROM
8
Min./max. alarm A1
Connector B
Min./max. alarm A2
SERIAL INTERFACE
10
4
1.4
Differential
pressure cell
Valve block
with pressure
gauge
_
p
2
+
p
1
1.3
1.5
1.2
1
1Differential pressure cell
1.1 Measuring diaphragm
1.2 Measuring springs
1.3 Lever
1.4 Elastic disc
1.5 Diaphragm axis
2Displacement sensor
3Microprocessor
4Memory
5Keys
6DIL switches
7Indicating unit with
LCD or LED
8Limit switch
9D/A converter
10 SERIAL INTERFACE
Fig. 2 ⋅ Functional diagram
EB 9527-1 EN
7
Technical data
1.2 Technical data
Differential pressure meter
Nominal rangembar0
100
1)
0
to
1600
0
to
to
160
0
to
250
0
to
400
0
to
600
0
to
1000
0
to
1)
2500
3600
1)
Adjustable span mbar
Class ± 1.0 %from
to
Class ± 1.6 %from
to
Class ± 2.5 %from
to
fromto< 35
≤ 100
≥ 60
< 60
≥ 35
≤ 2500
≥ 500
< 160
≥ 60
≤ 250
≥ 125
< 125
≥ 50
≤ 400
≥ 100
< 100
≥ 80
≤ 600
≥ 150
< 150
≥ 120
≤ 1000
≥ 250
< 250
≥ 200
≤ 1600
≥ 400
< 60
≥ 32
2)
≤ 3600
≥ 720
≥ 20
Nominal pressurePN 40, overloadable on one side up to 40 bar (PN 50 also for oxygen on request)
DisplayLCD Ø 90 or LED Ø 3
PerformanceOutput and indication linear to tank capacity
Deviation from terminal-ba-
< ±1.6 % or < ±2.5 % (including hysteresis depending on the span selected)
sed linearity
Sensitivity< 0.25 % or < 0.5 % depending on the span selected
0
to
1)
Effect of
static pressure
ambient temperature
at –20 to 70 °C on zero and span: < ±0.25 %/10 K
< 0.03 % / 1 bar
Limit switches2 software limit switches A1 and A2, configurable as minimum or maximum alarms
in accordance with NAMUR and EN 60947-5-6
Control circuit,
adjustable in 1% steps
acc. to NAMUR and EN 60947-5-6, e.g. KFA6- SR2- Ex2.W or KFA-SR2- Ex1.W
Rating according to connected switching amplifier
Hysteresis1 % based on maximum tank capacity (MCN)
Range of inversion, approx.< 0.6 %
Weight without valve block
with valve block
1)
A class accuracy of 0.6 % can be expected for measuring ranges 1000, 1600, 2500 and 3600 mbar with spans
Approx. 3 kg
Approx. 5 kg
≤ 100 % to ≥ 50 % of the nominal range.
2)
The class accuracy of Class 2.5 may not be reached in cases where the span does not fall within this specified span.
Note: All pressures stated as gauge pressures. All errors and deviations stated in % of the adjusted span.
8
EB 9527-1 EN
Technical data
Version 5006-05006-1
Output4 to 20 mA
Permissible load
– 12 V
U
S
=
R
B
20 mA
Output current circuitIntrinsically safe (Media 6 w. LCD/ LED)
see PTB 00 ATEX 2074 in appendix
Supply voltage U
two-wire transmitter
Permissible ambient temperature
Permissible storage temperature
Degree of protectionIP 65 acc. to DIN VDE 0470 or EN 60529
Materials
Version
Enclosure
Measuring diaphragm and seals
Measuring springs
Diaphragm plates and function. parts
Lever
Indicating unit
B
12 to 36 V DC12 to 28 V DC only in combination
with an intrinsically safe circuit
– 40 to + 70 °CT6 max. + 60 °C
T5 max. + 70 °C
–40 to +80 °C
Standard version
Cu Zn 40 PbCrNi steel
ECO/NBR (other materials on request)
CrNi steel
Polycarbonate, polyamide
Note!
Devices intended for oxygen service are labeled "Oxygen! Keep free of oil and grease!"
These versions are cleaned and assembled by the manufacturer under special conditions.
Appropriate gloves need to be worn on replacing parts that come into contact with oxygen,
e.g. measuring springs.
When returning devices designed for oxygen service to the manufacturer for repair, the sender assumes full responsibility that the handling of the devices to be repaired meets the requirements specified in VBG 62 or equivalent regulations until the devices are handed over
to the manufacturer. Otherwise, SAMSON AG will not accept any responsibility.
EB 9527-1 EN
9
Installation
2Installation
H
h
Fig. 3 ⋅ Arrangement for liquid level measurement,
e.g. diagram for the standard arrangement
in cryogenic applications
Clean the connections carefully prior to
connecting the measuring lines. Do not
clean the instrument using compressed
air or pressurized water.
Secure the instrument at the place of in-
stallation to a pipe, wall or mounting
plate free of vibration.
For attachment to vertical or horizontal
pipes, use a mounting component with
clamp. For wall mounting, use a mounting part without clamp. See the dimensional drawing on page 29 for mounting
to control panels.
Note!
+–
We recommend installing one shut-off valve
in each measuring line and, additionally,
an equalizing valve, or a SAMSON valve
block as a compact assembly.
Both measuring lines can then be shut off.
Additionally, the zero point can be checked
at the indicating unit by bypassing the
circuit.
2.1 Arrangement of instruments
2.2 Media 6 Indicating Unit
Make sure that the high-pressure line is
connected to the high-pressure connection and the low-pressure line to the lowpressure connection.
Note!
Special fittings are required to connect
measuring lines. In addition, depending on
the arrangement, connections left unused
must be fitted with plugs or venting screws
(see section 2.5 on accessories for more details).
10
EB 9527-1 EN
2.3 Valve block
The three valves combined in a valve block
with test and pressure gauge connections
(Fig. 4), which are flanged directly onto the
bottom of the dp cell, are available as an
accessory.
2.4 Shut-off and equalizing valves
As an alternative to the SAMSON valve
block, both shut-off valves as well as the bypass valve/equalizing valve can also be installed as shown in Fig. 5.
Installation
2.5 Accessories for connections
Open product connections are protected
against contamination by means of NBR
plugs.
Required screw fittings, plugs, venting
screws and screw joints with restrictions
used to dampen vibrations caused by the
process medium (especially when measuring gases) must be ordered separately.
Media 6
The screw fittings and SAMSON valve
blocks are listed together with their order
numbers in the Data Sheet T 9555 EN.
1Shut-off valve
2 Equalizing valve
Test connection
Shut-off valve (-)
Pressure gauge
connection
Fig. 4 ⋅ SAMSON valve block
Connection for
measuring lines
–+
Equalizing valve
(lead-sealable)
Bore hole for
sealing wire
Shut-off valve (+)
Fig. 5 ⋅
From the point of measurement
1
2
To indicating unit
Shut-off and equalizing valves, separate or
combined in a three-way or five-way valve block
EB 9527-1 EN
11