15A
MODEL NO. SEC-1215UL
NOMINAL INPUT VOLTAGE (PRE-SET) 120 VAC, 60 Hz, 3.3A
INTERNAL JUMPER CHANGE 230 VAC, 50 Hz
INPUT FREQUENCY 50 / 60 Hz
OUTPUT VOLTAGE, BOOST
1,2
14 VDC, or 14.4 VDC or disabled
OUTPUT VOLTAGE, FLOAT
1
13.5 VDC
OUTPUT AMPS 15A
OPERATING TEMPERATURE RANGE -20 to 40°C / -4 to 104˚F
WEIGHT, LB 4.8
WEIGHT, KG 2.2
DIMENSIONS (L x W x H), INCHES 8.5 x 8.4 x 3.3
DIMENSIONS (L x W x H), MM 218 x 214 x 83
PROTECTIONS Short Circuit, Overload, Reverse Battery Polarity
OUTPUT BANKS 3
SAFETY COMPLIANCE
i) Conforms to ANSI/UL STD 1564
ii) Certied to CAN/CSA STD C22.2 No. 107.2
EMI COMPLIANCE FCC Part 15(B), Class B
2 YEAR LIMITED WARRANTY
4004711
Automatic
Switch Mode
Battery Charger
Model
SEC-1215UL
15 Amps
12 VDC
Design Features
- Switch mode technology for high efciency, lightweight and
quiet operation
- Automatic operation for ALL Lead Acid Batteries Flooded,
AGM or Gel Cell
- Can charge 3 banks of batteries simultaneously, no isolator
necessary
- Can be used as a power supply or DC UPS when used in
conjunction with a battery
- User Congurable AC Input voltage 120 or 230 VAC,
50 / 60 Hz
- User Selectable ( by DIP Switch) Selectable for 2 or 3 stage,
rapid and safe charging of stand-alone and loaded Lead Acid
Batteries
- Ammeter & LED power status indicator
- Protections: Short circuit, overload, reverse battery polarity
- Convection cooled
- Intertek ETL Listed to meet UL Standard UL-1564, EMI
Compliant to FCC Part 15(B), Class B
1. Voltages based on battery temperature of 80°F / 26.6°C
2. Based on selection by DIP SWITCH
To view a full selection of Samlex products visit our website at www.samlexamerica.com or contact us: 1-800-561-5885 or sales@samlexamerica.com
12001-SEC-1215UL-0318NOTE: Specications are subject to change without notice