Salvajor Trough Collector S419 Installation & Operating Instructions Manual

Trough CollectorTM Model S419
Trough Conveying and Food Waste Collecting System
Installation & Operating
INSTRUCTIONS
ALL INSTALLATIONS SHOULD BE MADE IN ACCORDANCE WITH LOCAL AND NATIONAL PLUMBING AND ELECTRICAL CODES.
2 System Components 3 Fabricator Instructions & Installation 4 Plumbing 5 Electrical & Operating Instructions 6 Troubleshooting & How it Works 7 Warranty 8 General Terms and Conditions of Sale
FOR PRODUCT/WARRANTY REGISTRATION
Go to www.salvajor.com
Click on SUPPORT at the top of homepage
Click on PRODUCT REGISTRATION
4530 East 75th Terrace Kansas City, MO 64132-2081, USA Toll Free: 1.888.725.8256 I Fax: 1.800.832.9373 service@salvajor.com
I
www.salvajor.com
System Components
x 12 Lockwasher
x 12 Hex Nut
Collector
Hardware
Salvage Basin
(Shipped inside of Tank)
Collector Top Box
(May ship separate)
Diffuser
Gusher Head
(Optional)
ADDITIONAL
PARTS
Scrap Basket
(Shipped inside of Tank)
Collector Top
(May ship separate)
Collector Tank
Collector Hardware
Note: Drain piping, recirculation piping and trough not furnished
2
Fabricator Instructions
LCONTROL
15˚
15˚
90˚
3” Min.
Center Hole
Upon request, the Collector top may be shipped separately to a fabricator for welding to table.
TABLE CUT OUT DETAIL
Trough
12 1/4"
(31.11)
1¼”
ø
20"
(ø50.75)
6 1/2"
(16.51)
Weld the Trough Col­lector top into the table using these dimensions for the table cut out.
Note: Before welding confirm that there is a minimum of 22” above the Collector top for basket removal.
TROUGH DETAILS
At the closed end of the fabricated trough, punch a 2” hole, centered 1-1/4” from the bottom of the trough. This location ensures proper water flow down the trough. The trough should have a minimum depth of 3” at the closed end and a fall of at least 3/32” per running foot to en­sure adequate drainage to the unit.
Installation
FLANGE DIMENSIONS
5
3/4"
(
)
14.61
5
1/2"
(
)
13.97
The open end of the fabricated trough should include a flange to match the flange on the Trough Collector. The two flanges are to be butted together and securely welded.
4"
(
10.16
8
3/4"
(
22.23
)
)
The design of the trough may require that you rotate the Collector tank in relation to the top during installation. The tank can be rotated in 15 degree increments to ease installation and to keep the control square with the front of the table.
15˚
90˚
180˚
Before installation it may be necessary to move the control from the back to the front of the Trough Collector depending on orientation in the table. This is easily accomplished using the existing fasteners, mounting holes and wiring. If necessary, the control can be mounted remotely using an optional bracket.
Note: Additional field wiring is necessary for remote location of the control.
CONTRO
COLLECTOR TOP
COLLECTOR HARDWARE
COLLECTOR TANK
ADJUSTABLE LEGS
Note: Before installation of the Collector tank, the top should be welded into the table. Confirm that the top has the pre-installed gasket affixed before installation.
To install, raise the Collector tank up to the Collector top that has been welded into the table. Using the supplied hardware, attach the tank to the top. Ad­just the legs by turning the foot counter clockwise until they ex­tend to the floor.
ONTROL
3
Loading...
+ 5 hidden pages