Trough Collector
Job: Item No.:
Model S419
A Trough Conveying and
Food Waste Collecting System
Widely accepted in areas that restrict
the use of food waste disposers.
Recirculated Water used for scrapping
typically reduces water and sewer costs
dramatically. The Trough Collector consumes
only 2 gallons of new water per minute.
Trough Water Velocity with the Trough
Collector is 70 gallons per minute.
This velocity swiftly propels food waste down
the trough and into the Collector with no
additional hand movement, leaving both
hands free for high-volume scrapping.
The Trough Collector will let you keep up
with large conveyor or flight dishmachines.
Design Flexibility is offered by the
Collector as troughs can turn one or more
corners and have wider troughs for soaking
problem dishes.
Wider and Longer Troughs can be
designed because of the Collectors high
water velocity which allows you to soak
problem dishes or add gusher heads to
pre-rinse compartmental trays.
T Y P I C A L I N S T A L L A T I O N S
Model S419

Trough Collector Model S419
143/4"
(37.47)
4
5
/8"
(11.75)
45/8"
(11.75)
LEFT SIDE VIEW
C
D
327/8" (83.43)
ADJUSTABLE TO
36
7
/16" (92.55)
17
1
/8"
(43.42)
25/8"
(6.69)
FRONT VIEW
A
B
22" (55.88)
MINIUMUM
CLEARANCE
OVERHEAD
FOR BASKET
REMOVAL
AIR GAP
ONE BASKET PROVIDED WITH UNIT
Additional basket recommended at additional cost
SCRAP BASKET
DIMENSIONS
18
9
/16" Dia. x 131/4" High
(47.2) Dia. x (33.7) High
WE SUGGEST THE USE
OF RUBBER GUSHER
HEADS ALONG THE
TROUGH FOR SCRAPPING
AND PRE-FLUSHING.
(OPTIONAL AT ADDITIONAL COST)
FABRICATED TROUGH
(NOT FURNISHED), MUST HAVE
MATCHING FLANGE TO ATTACH
TO MODEL S419. (SEE DETAIL "B")
11/2"
PLUMBING
FITTINGS
AND VALVE
(SEE DETAIL "C")
3
/4" PIPE AND VALVE
(SEE DETAIL "C")
TROUGH CONNECTION
(SEE DETAIL "B")
CONTROL
PANEL
CAN BE
MOUNTED
ON LEFT
OR RIGHT.
WATER DIFFUSER FURNISHED.
2" DIA. HOLE REQUIRED
IN BACK OF TROUGH.
(SEE DETAIL "A")
DETAIL "A"_WATER DIFFUSER
TROUGH
SECTION
3" MIN.
DEPTH
DIFFUSER
LOCKNUT
GASKET
DETAIL "B"_TROUGH
CONNECTION FLANGE
5
1
/2"
(14.0)
R
1
/4"
(R.63)
4 "
(10.2)
8
3
/4"(22.2)
5
3
/4"(14.6)
TOP VIEW
221/2"
(57.15)
12
1
/4"
(31.11)
ø
19
1
/4"
(ø48.84)
TABLE CUTOUT DETAIL
121/4"
(31.11)
6
1
/2"
(16.51)
ø
20"
(ø50.75)
DETAIL "C" RECIRCULATION PLUMBING
RECIRCULATION
PLUMBING
NOT FURNISHED
Trough Collector Legend
A
Tank drain 2” NPT
●
B
1/2” conduit knockout electrical connection
●
C
Hot/cold shutoff valves 1/2” NPT
●
D
Removable Top
●
Note: Add 6”
from back of
trough to wall
for recirculation
piping.
F