TroughVeyor® Model TVL & TVR
Trough Conveying and Food Waste Disposing System
TroughVeyor
Model TVL Shown
Installation & Operating
TroughVeyors are available in either left
hand or right hand models to accomodate
trough water flow from right to left (TVL)
or left to right (TVR).
Left Hand Models: 300-TVL, 500-TVL
Right Hand Models: 300-TVR, 500-TVR
2 Additional Parts Contents
3 Fabricator Instructions & Attaching Disposer
4 Plumbing & Electrical
5 Operating Instructions & Troubleshooting
6 How it Works
7 Warranty
8 General Terms and Condition of Sale
ALL INSTALLATIONS SHOULD BE MADE IN
ACCORDANCE WITH LOCAL AND NATIONAL
PLUMBING AND ELECTRICAL CODES.
Disposer not
included in
NSF listing
INSTRUCTIONS
FOR PRODUCT/WARRANTY REGISTRATION
Go to www.salvajor.com
•
Click on SUPPORT at the top of homepage
•
Click on PRODUCT REGISTRATION
•
Manufacturers of Commercial Food Waste Solutions - Since 1944
4530 East 75th Terrace Kansas City, MO 64132-2081, USA
Toll Free: 1.888.725.8256
service@salvajor.com
Fax: 1.800.832.9373
I
I
www.salvajor.com

Additional Parts Contents
Installation &
Operating Manual
Diffuser
Gusher Head
(Optional)
Note: Drain piping not furnished
2

Fabricator Instructions
111/2" (29.21
)
7
3
/8" (18.75
)
83/8" (21.27
)
87/8" (22.54
)
LEFT HAND - Model TVL
331/2"
(
)
7
/8"
8
(
)
22.56
Weld the TroughVeyor into the table using the dimensions above for the table cutout.
DIFFUSER #980061
85.09
3”
MIN.
See TroughVeyor
Flange
Dimensions
#TVD3 GASKET
#TVD2 LOCKNUT
RIGHT HAND - Model TVR
331/2"
(
)
85.09
DIFFUSER
INSTALLATION DETAIL
8
(
22.56
TROUGHVEYOR FLANGE
DIMENSIONS
7
/8"
)
The open end of the fabricated
trough should include a flange
to match the flange on the
TroughVeyor. The two flanges
are to be butted together and
securely welded.
TROUGH SECTION
11/2" FEMALE
THREAD to 1
SWEAT FITTING
ADAPTER (NF
1
/2"
1
/2" UNION (NF)
)
1
A 2” diameter hole is required at the closed end of the trough for the factory furnished water diffuser which ensures a proper
water flow pattern down the trough. Center the 2” diameter hole 11/4” from the bottom of the trough. A 11/2” union can be used
instead of the 11/2” sweat fitting when the plumbing will need to be disconnected.
The closed end of the fabricated trough
should have a minimum depth of 3” and a fall of at least 3/32” per running foot so that there will be adequate drainage
to the TroughVeyor machine.
Attaching Disposer
1. Carefully remove the top housing assembly by removing the eight bolts
making sure not to damage the center gasket.
2. Apply lubricant to the rubber collar on the top housing and the beaded
collar on the transition of the TroughVeyor.
3. Install the top housing assembly up onto the beaded collar and tighten the
clamp so the top housing assembly can not be pulled down over the bead.
Cut the rubber baffles out of the hycar adaptor to reduce bridging
of food waste.
4. Measure distance from the bottom of the top housing to floor.
5. Turn the disposer on its side and install the leg support on the bottom of
the disposer and adjust the leg extension so the disposer will stand
approximately 1/2” below the bottom of the top housing.
6. Carefully balancing the disposer on the leg support, place it under the top
housing, aligning the ears on the shredder ring with the locking tabs of
the top housing.
7. Slide the center gasket into place. Insert the top housing bolts through
holes in the top housing and into the disposer body housing. As you the
tighten bolts, the disposer will pull up securely to the top housing. Extend
the leg extension securely on the floor, and tighten set screws.
8. If disposer drain orientation is incorrect loosen top clamp and rotate
disposer to correct location.
NOTE: It is important that the leg fit tightly between the disposer and the floor.
STOP!
If you have any questions about this installation call 1-888-SALVAJOR for installation advice.
3