Salvajor 300 TVL User Manual

Page 1
TroughVeyor
Job: Item No.:
Model TVL
A Water Trough Conveyor
and Disposing System
Model TVL, left hand operation
Model TVR, right hand operation
Recirculated Water used by the system for scrapping reduces water and sewer costs by thousands of dollars per year compared to a fresh water trough. The TroughVeyor consumes only 7 gallons of fresh water per minute.
Design Flexibility is offered by the TroughVeyor as troughs can turn one or more corners and have wider troughs for soaking problem dishes.
Wider Troughs are made possible by high water velocity that lets you soak problem dishes or add optional gusher heads to pre-rinse compartmented trays
T Y P I C A L I N S T A L L A T I O N S
Model TVL
Model TVL
Model TVR
Model TVL
Model TVR
Page 2
D
B
C
F
E
A
1915/16" (50.66)
201/2"
(52.15)
251/16" (63.66)
341/2"
(87.63)
E
F
A
B
2513/16" (65.62)
11/4" (3.1)
407/8"
(103.78)
341/2"
(87.63)
109/16" (26.77)
83/4"
(22.26)
23/4"
(6.99)
55/16"
(13.56)
2915/16" (76.04)
231/4"
(59.03)
203/16" (51.31)
12"
(30.48)
14"
(35.63)
111/2"
(29.21)
71/2"
(18.98)
1"
(2.54)
57/16"
(13.84)
63/16"
(15.74)
333/16"(84.26)
Adjustable to
36
3
/16"(91.92)
AIR GAP
TROUGH
OPENING
31/8"
(7.94)
E
TroughVeyor Model TVL
NOTE:
Allow 6"
from back
of trough
to wall for
recirculation
piping.
NOTE: Maximum length for 8 inch wide trough is 24 feet. Maximum length for 12 inch wide trough is 18 feet.
87/8"
(
22.54
)
33
1
/2"
(
85.09
)
(TABLE CUT-OUT SIZE)
DRAIN PIPING
(NF)
=
NOT FURNISHED
DRAIN
PIPING
(NF)
2"TANK RESERVOIR DRAIN PIPING
(NF)
GUSHERHEAD
(
OPTIONAL
)
GUSHERHEAD
(
OPTIONAL
)
DIFFUSER
11/2" VALVE(NF
)
11/2" RECIRCULATION PIPING(NF
)
3
/4" PIPING(NF
)
45
O
111/2"
(
29.21
)
8
3
/8"
(
21.27
)
8
7
/8"
(
22.54
)
7
3
/8"
(
18.73
)
NOTE: Maximum number of gusher heads is 3.
2" tank reservoir drain can be
run separately or be tied in
with the disposer drain.
Model TVL
DRAIN PIPING
3
/4" VALVE
(NF)
TROUGH SECTION
3" MIN.
DEPTH
DIFFUSER
LOCKNUT
GASKET
(
LEFT HAND OPERATION
)
WA T ER FL O WS RI G HT-TO-LE F T
TroughVeyor Legend
Disposer outlet can be rotated at most
A
any angle by rotating disposer. Rubber drain accepts 2” piping or 3” piping by removing drain insert.
Tank reservoir drain – Plumb 2” piping
B
from valve to floor drain or connect to disposer drain piping ahead of P trap.
Disposer electrical connection.
C
Disposer to control connection.
D
Incoming electrical connection.
E
Hot and cold water connection. 1/2” NPT
F
ALL CONNECTIONS ARE TO BE MADE BY
QUALIFIED PERSONNEL WHO WILL OBSERVE
ALL LOCAL AND NATIONAL CODES.
NOTE: Dimensions in parenthesis are in centimeters
TABLE CUT-OUT: 8
7
8”(22.54) x331⁄2”(85.09)
Trough matching
flange layout
Page 3
D
B
C
F
E
A
1915/16"
(50.66)
1813/16" (47.74)
251/16"
(63.66)
341/2"
(87.63)
E
A
B
2513/16" (65.62)
11/4" (3.1)
407/8"
(103.78)
341/2"
(87.63)
109/16" (26.77)
83/4"
(22.26)
23/4"
(6.99)
55/16"
(13.56)
2915/16" (76.04)
231/4"
(59.03)
203/16" (51.31)
12"
(30.48)
14"
(35.63)
111/2"
(29.21)
71/2"
(18.98)
1"
(2.54)
57/16"
(13.84)
6
1
/4"
(15.82)
333/16"(84.26)
Adjustable to
36
3
/16"(91.92)
AIR GAP
TROUGH OPENING
31/8"
(7.94)
E
F
NOTE: Allow 6" from back of trough to wall for recirculation piping.
NOTE: Maximum length for 8 inch wide trough is 24 feet. Maximum length for 12 inch wide trough is 18 feet.
11/2" VALVE(NF
)
11/2" RECIRCULATION PIPING(NF
)
3
/4" PIPING(NF
)
3
/4" VALVE
(NF)
87/8"
(
22.54
)
33
1
/2"
(
85.09
)
(
TABLE CUT-OUT SIZE
)
2"TANK
RESERVOIR
DRAIN PIPING
(NF)
GUSHERHEAD
(
OPTIONAL
)
GUSHERHEAD
(
OPTIONAL
)
DIFFUSER
45
O
TROUGH SECTION
3" MIN. DEPTH
DIFFUSER
LOCKNUT
GASKET
111/2"
(
29.21
)
83/8"
(
21.27
)
87/8"
(
22.54
)
73/8"
(
18.73
)
Model TVR
DRAIN PIPING
2" tank reservoir drain can be
run separately or be tied in
with the disposer drain.
DRAIN PIPING
(NF)
=
NOT FURNISHED
DRAIN
PIPING
(NF)
NOTE: Maximum number of gusher heads is 3.
TroughVeyor Legend
Disposer outlet can be rotated at most
A
any angle by rotating disposer.
Rubber drain accepts 2” piping or 3”
piping by removing drain insert.
Tank reservoir drain – Plumb 2” piping
B
from valve to floor drain or connect to
disposer drain piping ahead of P trap.
Disposer electrical connection.
C
Disposer to control connection.
D
Incoming electrical connection.
E
Hot and cold water connection. 1/2” NPT
F
ALL CONNECTIONS ARE TO BE MADE BY
QUALIFIED PERSONNEL WHO WILL OBSERVE
ALL LOCAL AND NATIONAL CODES.
NOTE: Dimensions in parenthesis are in centimeters
TroughVeyor Model TVR
(
RIGHT HAND OPERATION
WA T ER FL O WS LE F T-TO-RI G HT
)
Trough matching
flange layout
TABLE CUT-OUT: 87⁄8”(22.54) x331⁄2”(85.09)
Page 4
Salvajor TroughVeyor System
MODEL TV
S P E C I F I C A T I O N S
CONSTRUCTION MODELS AVAILABLE
Stainless Steel Components
Salvage Basin
Disposer Safety Cover
Adjustable Legs
Control Panel
ELECTRICAL
Pre-wired NEMA 4 Panel
Watertight Conduit/ Fittings
Separate Component Grounding
Thermally Protected Motors
Totally Enclosed Motors
Line Voltage Disconnect
Disposer Safety Switch
24 Volt Safety Circuitry
PLUMBING
Corrosion Resistant Components
Automatic Water Blender
Solenoid Valves
Unions
Check Valves
Incoming Water Valves
Non-clogging Pump Design
Backflow Prevention Device
Quick Opening Drain Valve
Left-Hand Right-Hand Disposer Lbs.
300 TVL
500 TVL
750 TVL
300 TVR 3
500 TVR 5
750 TVR 7
HP 327 HP 335
1
2 HP 343
ACCESSORIES
Remote Start-Stop Button
Remo
Corre
Gush
te Mounting Bracket
ctional Package
er Heads
VOLTAGES AVAILABLE
(
SPECIFY EXACT OPERATING VOLTAGE
208V ■230V ■460V,
Disposer 3-7 Pump Separator
1
2 HP 208
3
4 HP 208
1
6 HP 208
60 Cycle, 3 Phase
-
230
-
230
-
230
)
-460V
-460V
-460V
FULL LOAD AMPS
TOTAL FULL LOAD AMPS THREE PHASE
MODEL 208V 230V 460/480V Total HP
300-TV 12.64 11.66 5.83 3.92 500-TV 17.64 16.16 8.13 5.92 750-TV 23.64 21.66 10.83 8.42
SAMPLE SPECIFICATIONS
Unit shall be TroughVeyor, a complete food waste conveying and disposing system with recirculating water as manufactured by Salvajor. Model
Furnished with a pre-wired control panel and Stainless Steel NEMA 4 watertight enclosure.
_____ TV__ , ____Volts, ___Hz, ___Phase.
UTILITIES REQUIRED
208, 230 or 460 Volt, 60 cycle, 3 phase electric service,
3
4" hot and cold water supply and reduce to 1⁄2" at
connection. 2" or 3” waste line, 2" tank reservoir drain.
(Specifications subject to change without notice .)
The Salvajor Company 4530 East 75th Terrace Kansas City, Missouri 64132-2081, USA
1-800-SALVAJOR (816) 363-1030 FAX:1-800-832-9373 www.salvajor.com Email: sales@salvajor.com service@salvajor.com
Manufacturers of Commercial Food Waste Di sp os in g Sy st em s si nc e 19 44
Disposer
not included
in listing.
Printed in USA
Form No.TV-9-BH
Loading...