Salus TRV10RFM, TRV28RFM, TRV10RAM Quick Manual

Note: If all valve dimensions are consistent with those given below, then the TRV
head will be compatible. If there are dimension dierences, contact us or the installer to nd replacement for the valve.
Note: One thermostat can control up to 6 TRV heads within one room.
Quick Guide
Importer:
SALUS Controls plc Salus House, Dodworth Business Park Whinby Road, Barnsley S75 3SP, United Kingdom
DISTRIBUTOR OF SALUS CONTROLS:
QL CONTROLS Sp. z o.o., Sp. k. Rolna 4, 43-262 Kobielice, Poland
www.salus-controls.eu
SALUS Controls is a member of the Computime Group
Maintaining a policy of continuous product development SALUS Controls plc reserve the right to change specification, design and materials of products listed in this brochure without prior notice.
IV 2018
Introduction
The TRV thermostatic head is controlled through wireless ZigBee communication protocol. It can replace classic, manual thermostatic head in a very quick and easy way. For proper operation of the TRV head it is necessary to synchronize it correctly with wireless thermostat using the CO10RF coordinator or UGE600 Internet gateway (all devices are sold separately). TRV head paired with the iT600RF series digital thermostats (e.g. VS10RF / VS20RF / HTRS-RF (30) / HTRP-RF (50) / TS600) provides comfort within the whole room, not just in the radiator area.
Product Compliance
This product complies with the essential requirements and other relevant provisions of Directives 2014/53/EU, 2014/30/EU, 2011/65/EU. The full text of the EU Declaration of Conformity is available at the following internet address: www.saluslegal.com.
Safety Information
Use in accordance to national and EU regulations. Use the device as intended, keeping it in dry condition. Product for indoor use only. Installation must be carried out by a qualied person in accordance to national and EU regulations.
The TRV head is a modulating device. This means that the valve can be gradually closed or opened, depending on the current room temperature measured by thermostat and the setpoint temperature.
For MMA or Herz M28x1,5 thermostatic valves make sure you have a metal washer as shown in the picture.
For a standard thermostatic valve with M30x1,5 thread (e.g. Oventrop, Honeywell, TA, Heimeier) TRV10RFM head installation looks like as shown in the picture.
When mounting the TRV10RFM head on the Danfoss RA valve (see picture), please use the RA adapter included with the head. However, to install the TRV10RAM head it is necessary to use the Allen Wrench key.
NOTE: For the Comap valve with M28 thread you do not need to mount a metal washer.
TRV head is compatible with most of the thermostatic valves available on the market, however, before installation, please check whether the valve is suitable for use with the TRV head.
Put the RA
adapter on the
Danfoss RA
valve.
Place TRV
head on the
valve.
Tight RA
adapter and screw TRV10RFM head on it.
Assembly to
the valve and
tighten only
2 out of 4
screws.
Measure the thread diameter.
Thread for the TRV10RFM must
have a diameter of 30 mm, and for
the TRV28RFM - 28 mm.
Remove the battery cover located on
the side of the device.
When the LED diode lights up continuously with a red color,
screw the TRV on the valve.
When the LED goes out and TRV head does not make any sounds,
adaptation process is nished. Equipment is ready for pairing
with thermostat.
Press any button to start the adaptation process of TRV head with thermostatic valve. The process takes
up to 5 minutes.
Insert the batteries according to the
markings and close the battery cover.
The LED will start blinking green /
red informing about the software
version.
Measure the height of the valve’s
pin when it is in the open position.
For TRV10RFM valve’s pin height
should be 13-15 mm, while for
TRV28RFM 10-11 mm.
dismantle the old radiator
head
radiator
valve
To achieve the best possible results in cooperation between the thermostat and the heating source, it is recommended to use the RX10RF receiver. RX10RF turns on the heat source depending on the demand signal sent by thermostat. More informations about RX10RF receiver is included in its user manual.
1
2
3
4
Opening the head / indication of the device status
Closing the head / indication vof the device status
Pairing button
LED diode (indicates device status)
Box Content
TRV28RFM head installation
User interface
Buttons function
TRV10RFM head installation
TRV head setup
TRV head installation on the Danfoss RA valve
General informations
Checking compatibility with the heating system
TRV10RFM
adapter
Manual instruction
2 x AA batteries
metal
washer
Allen Wrench keyTRV10RFM
Each box additionally contains:
TRV28RFM
TRV10RAM
TRV28RFM TRV10RAM
+
+
OR
1
2
mm102030
3
mm102030
40
50
TRV10RFM HEAD MOUNTING
TRV10RAM HEAD MOUNTING
1
2
3
4
5
6
To do this... Press the...
...pair with thermostat ...pairing button for 10 seconds.
...lock/unlock the buttons
...pairing and close buttons together for 5 seconds.
...manually open the valve ...opening button for 5 seconds.
...manually close the valve ...closing button for 5 seconds.
...enter the automatic mode ...shortly pairing button
...remove the head from the ZigBee network
...pairing button for 10 seconds
...restore factory default settings
...Open , pairing , and close buttons together for 5 seconds
Wireless, thermostatic TRV head
Manual for models: TRV10RFM, TRV10RAM i TRV28RFM
Note: Buttons lock itself automatically after 5 minutes from the last one keystroke.
0 TRVs on this thermostat
Note: The following example shows the pairing process with the VS10/20..RF thermostat.
For HTRS-RF(30) and HTRP-RF(50) thermostats, the pairing process shall be done in the same way.
Note: To exit the manual mode and go back to auto mode - press once the pairing button (antenna). The red LED diode will ash once, indicating return to auto mode.
Choose the type of coordinator for ZigBee network
Choose one type of ZigBee network coordinator and prepare it for work with iT600 series devices:
LED diode on TRV head ashes in
orange. Now TRV head need to be
paired with thermostat. NOTE: TRV head and thermostat must be in the same heating zone!
• Online - system is connected to the Internet via an Internet gateway UGE600 or
• Oine - with an option of connecting system to the Internet using a gateway UGE600 or
• Oine - by using CO10RF coordinator - no possible to connect system to the Internet
Thermostat pairing with the TRV head in Online mode
Thermostat pairing with the TRV head in Oine mode Manual mode
LED diode indications
1
1
5
6
7
8
9
10
WARNING! Do not use the CO10RF coordinator together with UGE600.
Thermostat will go to the main screen.
Device is paired with the coordinator, diode on TRV head will start blinking in orange.
Diode on the TRV head lights up once green, then stops ashing.
TRV head has been added.
5 sec.
5 sec.
5 sec.
OR
OR
Press and hold the pairing
button for 10 seconds, the diode on the
TRV head should start ashing in red.
Press and hold the pairing button
for 10 seconds, the diode on the TRV
head should start ashing in red.
10 sec.
10 sec.
Choose the device type - TRV head
Install the TRV head
on the valve according to the
instructions on the previous page.
Install the TRV head
on the valve according to the
instructions on the previous page.
2 3
4
Open the ZigBee network
Close the ZigBee network
5 sec.
WARNING! You can connect up to 6 TRV heads to one regulator.
WARNING! You can connect up to 6 TRV heads to one regulator.
When... TRV Status LED diode... Valve
...power supplied
TRV head indicates the software version
...alternately ashes red / green indicating the software version. A more detailed description is in „TRV head setup” section on the previous page.
...TRV head adapts to the valve
... ashes in green, then red and it switches o when the adaptation process has been done. When the LED will continue to ash red it means that adaptation process failed.
...TRV head has been added to the network.
... ashes in orange (has been added to the network). TRV head should be paired now with thermostat.
closed
..TRV head is added to the network, but it is not paired with thermostat
Auto mode ...ashes in orange closed
TRV head is open in manual mode
...ashes twice in green when pressed the opening or closing button.
100% open
TRV head is closed in manual mode
...ashes once in green after a short press of the opening or closing button.
closed
...TRV head is in normal operating mode
Auto mode
...ashes once in green after a short press of the opening or closing button.
open in range from 1% up to 100%
Auto mode
...ashes once in red after short press of the opening or closing button.
closed
TRV head is open in manual mode
....ashes twice in green after short press of
the opening or closing button.
100% open
TRV head is closed in manual mode
...ashes twice in red after short press of the opening or closing button.
closed
The Window Open function is active
...ashes in green and red 2 times every 10 seconds.
100% open
...TRV head is paired with thermostat.
Auto mode ...does not light up.
...TRV head is removed from the network.
...ashes once in orange (TRV head is removed from the coordinator’s memory) and then ashes in red.
...identication of the TRV head is turned on
...ashes in green for a maximum of 10 minutes.
... wireless communication with the TRV head is lost
Auto mode
...ashing alternately in green and red after a short press of the opening or closing button.
TRV head is open in manual mode
...ashes twice in green after a short press of the opening or closing button.
100% open
TRV head is closed in manual mode
...ashes twice in red after a short press of the opening or closing button..
closed
...when battery power is too low
...ashes three times in red every 10 seconds (or less often if the batteries in the TRV head are very weak).
25% open
...an error occurred during TRV head assembly
... ashes alternately in red and green.
Additional functions:
Frost protection mode
When valve is manually closed, the TRV head automatically activates frost protection mode. Setpoint temperature of the frost protection mode is set on the thermostat. This function is activated when the room temperature drops below the frost protection setpoint teperature set on the thermostat. TRV head automatically maintains setpoint temperature if there is communication between TRV head and thermostat.
Open window function
TRV head checks the speed of temperature drop in the room. If the temperature drop is fast, it is assumed that in the room has been opened window. The function is active when the TRV head communicates with thermostat, is in automatic mode and the batteries are not discharged.
Protection against scale deposits
Do not leave the valve open for a long time because it can cause scale deposits on it. TRV head has a protection function against scale deposits. It starts to opening automatically once every 14 days if no valve movement is detected. Protection will also work no matter if TRV head is in auto mode or manual mode
Technical Information
Warranty
SALUS Controls warrants that this product will be free from any defect in materials or workmanship, and shall perform in accordance with its specication, for a period of two years from the date of installation. SALUS Controls sole liability for breach of this warranty will be (at its option) to repair or replace the defective product.
To open or close the TRV head in manual mode, follow the procedure described below. If the steps described below do not bring any results it means that probably the TRV head buttons are locked and they should be unlocked rst.
To open the valve manually, press and hold the opening button. The green LED diode ashes once and the TRV head will start to open the valve.
To close the valve manually, press and hold the closing button. The red LED diode ashes once and the TRV head will start closing the valve.
Model
TRV10RFM / TRV28RFM / TRV10RAM
Type
Wireless, thermostatic TRV head M30 x 1.5 / M28 x 1.5
LED signaling Tri-color LED (red/green/orange)
Adaptation with a valve Automatic
Power supply 2 x AA batteries
Control method Modulation
Communication Wireless, ZigBee 2.4 GHz
Operating temperature 0 to 45°C
Storage temperature -20 to 60°C
Ambient humidity 5 to 95% RH
IP protection level IP30
Dimensions [mm] H=88.6, Ø=51
5 sec.
5 sec.
Customer Name: ..................................................................................
Customer Address: ..............................................................................
..........................................................................................................................
............................................................................... Post Code:.........................
Tel No: .............................................................................................................
Email: ..............................................................................................................
Engineers Company: ........................................................................................
Tel No: .............................................................................................................
Email: ..............................................................................................................
Instalation Date: ..............................................................................................
Engineers Name: .................................................................................
Engineers Signature: ........................................................................................
3
4
5
6
7
Scan for equipment
SALUS
Smart Home
8
10
11
12
9
Name this equipment
TRV in the living room
Connect equipment
Finish
3
14
13
Save
Select TRV(s) for living room
Name this equipment
15
1 TRVs on this thermostat
3
2
Loading...