Salus RT510RF, RT510BC, RT510TX, RXRT510 Quick Manual

Page 1
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
2
4
6
8
10
Introduction
Button functions
LCD Icon description
Product compliance
Safety Information
This product complies with the essential requirements and other relevant provisions of the following EU Directives: EMC 2014/30/EU, LVD 2014/35/EU, RED 2014/53/EU and RoHS 2011/65/EU. Full text of the EU Declaration of Conformity is available on www.saluslegal.com
RT510 / RT510TX / RT510RF is a programmable room thermostat used to control room temperature. Device launching heating system by shorting terminal blocks, simultaneously informing the action and showing this information on the LCD display. Extended features allows us to use various operating modes
- automatic (time schedules), manual, frost protection or holiday. Before use please read this manual carefully. Use only AA 1.5 V alkaline batteries in the thermostat. Place the batteries into the battery slot located under the cover. Do not use rechargeable batteries.
Use in accordance to national and EU regulations. Use the device as intended, keeping it in dry condition. Product for indoor use only. Installation must be carried out by a qualied person in accordance to national and EU regulations.
RT510 / RT510TX Thermostat RXRT510 Receiver
1
6
7
8
9
4
3
2 5
1. Boost function
2. Manual Mode
3. Frost protection / Holiday Mode
4. Increase button
5. Decrease button
6. When in Manual Mode,
ON will turn the boiler on.
7. When in Manual Mode, OFF will turn the boiler o.
8. Receiver operates in automatic mode according to the thermostat
9. Receiver output is controlled by the On/O slide switch.
1. Day of the week
2. Program number
3. Program indicator
4. Settings
5. Temperature measured / set
6. Boost function
7. Low battery status
8. Wireless connection with the receiver
9. Heating Mode On
10. Manual Mode On
11. Holiday Mode On
12. Frost Protection Mode On
13. Temperature unit
14. AM / PM
15. Clock
RT510 Thermostat RT510TX Thermostat
Thermostat supply 2 x AA alkaline batteries 2 x AA alkaline batteries
Thermostat rating max 3 (1) A -
Outputs
Voltage free NO / COM / NC terminals
-
Temperature range 5 - 35°C 5 - 35°C
Temperature accuracy 0.1°C or 0.5°C 0.1°C or 0.5°C
Hysteresis ±0.25°C or ±0.5°C ±0.25°C or ±0.5°C
Radio frequency - 868 MHz
Dimension [mm] 120x96x27 120x96x27
RXRT510 Receiver
Receiver supply 230 V AC
Receiver rating max 16 (5) A
Outputs Voltage free NO / COM terminals
Radio frequency 868 MHz
Dimension [mm] 96x96x27
SALUS Controls plc SALUS House Dodworth Business Park South, Whinby Road, Dodworth, Barnsley S75 3SP, UK. T: +44 (0) 1226 323961 E: sales@salus-tech.com
E: techsupport@salus-tech.com
SALUS Controls is a member of the Computime Group.
Maintaining a policy of continuous product development SALUS Controls plc reserve the right to change specification, design and materials of products listed in this brochure without prior notice.
RT510, RT510TX, RT510RF
DIP Switch Settings
RT510 Wiring diagram
L
RT510TX
Thermostat
N
M
COM
NO
NC
OR
MAX 3 (1) A
AC 230 V
RT510
Thermostat
L
N
RXRT510
Receiver
AC 230 V
COM
L
L
M
N
N
NO
OR
AC 230 V
MAX 16 (5) A
L
RT510TX
Thermostat
M
COM
NO
NC
COM
NO
NC
OR
MAX 3 (1) A
AC 230 V
RT510
Thermostat
RT510
Thermostat
L
L
NO
N
N
COM
RXRT510
Receiver
RXRT510
Receiver
AC 230 V
COM
L
L
M
N
N
NO
OR
AC 230 V
MAX 16 (5) A
RT510TX Wiring diagram
Setting the time
Note: If you are using the RT510RF pack, the pairing between the thermostat and the receiver is already done.
RT510TX
Thermostat
RT510TX
Thermostat
L
L
NO
N
N
COM
RXRT510
Receiver
RXRT510
Receiver
AC 230 V
COM
L
L
M
N
N
NO
OR
AC 230 V
MAX 16 (5) A
RT510TX
Thermostat
RXRT510
Receiver
COM
L
L
M
N
N
NO
OR
AC 230 V
MAX 16 (5) A
RT510 Terminals description
RXRT510 Receiver terminals description
Terminal Description
1 - COM Common Terminal
2 - NC Switched Live OFF
3 - NO Switched Live ON
Terminal Description
NO Switch Terminal
COM Common Switch Terminal
L, N Supply (230 V AC)
NO COM L N
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
1
3
5
7
9
Press or to select the hour format.
Press the buttons SELECT and SET
together for 3 sec.
Press SELECT to conrm.
Press SELECT to conrm.
Press SELECT to conrm.
Press SET to conrm.
Press or to set the hour.
Press or to set the minutes.
Press or to set day of the week.
Thermostat will return to the main screen.
3 sec 3 sec
Programming - automatic mode
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
2
4
6
8
10
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
1
3
5
7
9
Use the or button to select day / days
from which you want to start programming.
Use the or button to set the hour
to start the program #1.
Use the or button to set the minutes
to start the program #1.
Use the or button
to set the temperature for program #1.
Follow steps 4-9,
to dene programs 2-6.
Press SET button to end programming.
Press the SET button to start programming.
Press SELECT to conrm.
Press SELECT to conrm.
Press SELECT to conrm.
Press SELECT to conrm.
In this mode, user can set the schedules for thermostat (temperature setpoints for specic periods of time). To do this, rstly choose programming mode: “5-2” (business days + weekend) or “24h” (each day separately) using parameter d04 from Installer mode. Programmed schedules should use all time periods.
The DIP Switches can be found on the rear of your thermostat.
Control feature TPI Span
Operation When TPI is selected on DIP
switch № 2, the DIP switch № 1 is functional. You can choose the Cycles Per Hour between a lower comfort level (6CPH) and a higher comfort level (9CPH).
When Span is selected on DIP switch № 2, the DIP switch № 1 is not functional. The temperature accuracy of your thermostat is set to ± 0.25 °C.
2
3 5 6
4
1
15 14 1213
8
9
11
7
10
MON TUE WED THU FRI SAT SUN
MON
MON TUE WED THU FRI
MON TUE WED THU FRI
MON TUE WED THU FRI
MON TUE WED THU FRI
MON TUE WED THU FRI
MON TUE WED THU FRI
MON TUE WED THU FRI
MON TUE WED THU FRI
MON TUE WED THU FRI
THU
THU
THU
MONMON
MON
MON
MON
www.salus-tech.com
Issue Date: February 2018 V028
Quick Guide
868.0-868.6MHz; <13dBm
Page 2
Temporary Override mode
Hourly temperature Override Mode (+Hr)
RT510TX thermostat pairing with the receiver Installer mode
Reset of the RT510 thermostat
Reset of the RT510TX thermostat
Manual Mode and setting setpoint temperature
Frost Protection
Sleep mode
Holiday Mode
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
2
4
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
1
3
Using or button set a new setpoint
temperature for override.
Using or buttons set new setpoint
temperature.
Press three buttons at the same time
for 3 seconds.
Use or button to set the number
of days for Holiday Mode.
Using or buttons set new setpoint
temperature.
Press +Hr button to set number of hours for temperature override (e.g. to set up override
for 3 hours, press the button 3 times).
Press the + Hr button until number of hours
disappears from display.
Press button to activate the Manual Mode.
Hold down button for 3 seconds
to activate the Holiday Mode.
Press button to turn On Frost
Protection mode.
Press button again to turn
O Frost Protection mode.
Press SET button
to conrm.
Press SET button to conrm.
You can set up to 31 days.
Using SELECT button choose the parameter.
Press SET to conrm.
Press SELECT to conrm.
Using or buttons set a parameter value.
Follow steps 2-5, to set next parameters.
To exit the installer mode, wait 10 seconds
- thermostat will return automatically to the main screen.
Press any key to deactivate sleep mode. Thermostat will return to the previous mode.
Thermostat is in sleep mode.
After new setpoint temperature set,
thermostat will return to the main screen.
After new setpoint temperature set,
thermostat will return to the main screen.
This function is available only in automatic mode (schedule). If a new setpoint temperature will be set during the schedule - it will be maintained until next time interval starts according to programmed schedule.
In this mode thermostat does not work according to the programmed schedule but it will maintain selected temperature.
In this mode the “frost protection” temperature is maintained for a specic number of days.
This function is available in Automatic and Manual Mode. It is used to change the setpoint temperature for a specied number of hours (up to 9 hours). Once that time is over, thermostat returns to previous mode.
Turning o hourly temperature override mode before time’s up
Turning O the Frost Protection mode
Begin the pairing process
End the pairing process
Test the pairing process
Temporary Override mode will be disabled when new schedule will be set.
To turn o the Manual Mode press button. Once the manual mode is o, the hand icon on the thermostat will disappear.
To turn o the Holiday Mode, hold down button for 3 seconds. The airplane icon should disappear from the display.
Temperature of the Frost Protection mode is set as default at 5°C. This temperature can be changed in Installer Mode in d03 parameter.
When you want to change the batteries your device will use the internal memory to backup your settings. You have 30 seconds to change the batteries before losing your settings.
When the sleep mode is activated, all thermostat functions are paused.
Press the RESET button once. You can use a paper clip. Your thermostat will be reset and will start up automatically.
Remove the batteries without pressing any button. Wait 2 minutes and insert the batteries again. Your device will be restarted.
If you bought the RT510TX and RXRT510 seperately then pair as follows. Please make sure that receiver switchers are set on AUTO and ON position. Connect your receiver to power supply - LED indicator will ash red.
2
2
4
4
1
1
3
3
3 sec
3 sec 3 sec
3 sec
Note: If you are using the RT510RF pack, the pairing between the thermostat and the receiver is already done.
dxx Function Parameter Default value
d01 Temperature display increments 0.1°C or 0.5°C 0.5°C
d02 Temperature oset +/- 3.0°C 0.0°C
d03 Frost Protection setpoint temperature 5.0°C - 17.0°C 5.0°C
d04 Programmer selection 5/2 or 24 hr (7d) 52d
RESET
SELECT
SET
TEST / PAIRING
SELECT
+
+
SET
TEST / PAIRING
SELECT
SET
Press TEST / PAIRING button to check the
connection with the receiver.
ON
AUTO
OFF
MANUAL
1 sec
3 sec
3 sec
Hold and buttons simultaneously
for 3 seconds to start the sleep mode.
2
4
6
1
3
5
WED
WED
WED
WED
WED
WED
WED
WED
SAT
SAT
SAT
SAT
SAT
SAT
SAT
SAT
SAT
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
(the pairing process takes up to 9 minutes)
Press and hold TEST/PAIRING button
for 3 seconds.
3 sec
THU
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
Once devices are successfully paired, LED on the receiver will go solid red. Press and hold TEST / PAIRING button for 3 seconds to end
the pairing process.
3 sec
3
THU
TEST / PAIRING
SELECT
SET
Press TEST / PAIRING button again to
return to the main screen.
ON
AUTO
OFF
MANUAL
1 sec
THU
THU
THU
THU
THU
THU
THU
THU
THU
Loading...