This product complies with the essential requirements and other relevant provisions of the following
EU Directives: 2014/30/EU, 2014/35/EU, 2014/53/EU and 2011/65/EU. The full text of the EU Declaration of
Conformity is available at the following internet address: www.saluslegal.com.
Safety Information
Use in accordance with the EU and national regulations. For indoor use only. Keep your device completely dry.
This product must be installed by a competent person and in accordance with all the EU and national regulations.
Always isolate the AC Mains supply before installing or working on any components that
require 230 VAC 50Hz supply.
Box content
The box includes the RT310 thermostat, 2 AA batteries a set of screws and the Quick Guide installation manual.
RT310 thermostat2X screws and plugs
2xAA batteriesQuick Guide Installation
RT310 Installation Manual 03
Page 4
Introduction
A room thermostat simply switches the heating system on and off as necessary. It works by sensing the air
temperature, switching on the heating when the air temperature falls below the thermostat setting, and
switching it off once this set temperature has been reached.
Turning a room thermostat to a higher setting will not make the room heat up any faster. How quickly the room
heats up depends on the design of the heating system, for example, the size of boiler and radiators. Neither
does the setting affect how quickly the room cools down. Turning a room thermostat to a lower setting will
result in the room being controlled at a lower temperature, and saves energy.
The heating system will not work if a time switch or programmer has switched it off.
The way to set and use your room thermostat is to find the lowest temperature setting that you are comfortable
with, and then leave it alone to do its job. The best way to do this is to set the room thermostat to a low
temperature – say 18⁰C – and then turn it up by one degree each day until you are comfortable with the
temperature.
You won’t have to adjust the thermostat further. Any adjustment above this setting will waste energy and cost
you more money.
If your heating system is a boiler with radiators, there will usually be only one room thermostat to control the
whole house. But you can have different temperatures in individual rooms by installing thermostatic radiator
valves (TRVs) on individual radiators. If you don’t have TRVs, you should choose a temperature that is reasonable
for the whole house. If you do have TRVs, you can choose a slightly higher setting to make sure that even the
coldest room is comfortable, then prevent any overheating in other rooms by adjusting the TRVs.
Room thermostats need a free flow of air to sense the temperature, so they must not be covered by curtains
or blocked by furniture. Nearby electric fires, televisions, wall or table lamps may prevent the thermostat from
working properly.
04 RT310 Installation Manual
Page 5
Features
The RT310from SALUS Controls is a stylish and accurate
digital thermostat with an easy to read Liquid Crystal Display
(LCD).
Features
• Frost protection(selectable)
• Low-Battery Warning
• Low-Battery Detection
• Modern Casing
• Sleep Mode
• User Friendly
Installation
The ideal position to locate the RT310 thermostat
is about 1.5m above floor level, in a location where
the thermostat is accessible, reasonably lit and free
from extremes of temperature and draughts. Do not
mount the thermostat on an outside wall, above a
radiator or in a location where it may be subjected
to direct sunlight. The electrical connections to
the RT310 are made to the supplied industry
standard backplate. This simplifies installation, as
no connections are made to the controller itself.
Connection details are shown below - no Earth
connection is required for the correct and safe
operation of the RT310, but a parking terminal is
provided to connect an Earth wire if one is present.
TERMINALDESCRIPTION
1 (COM)Common Terminal
2 (NC)Switched Live OFF
RT310 frontBackplate
1
2
3
3 (NO)Switched Live ON
Terminal description
COM
NC
Wiring configuration
RT310 Installation Manual 05
NO
Page 6
DIP switch settings
The DIP switches are found on the rear of your thermostat and can be used to change the span (temperature
accuracy) of your thermostat from the default +/-0.5°C to +/-0.25°C. This may cause your boiler to operate more
frequently. The DIP switches are located on the back of the thermostat. ON +/-0.25°C, OFF +/-0.5°C.
The span is the accuracy with which the thermostat operates when displaying your temperature. You can
increase the accuracy by setting the span to +/-0.25°C, meaning that your thermostat will be sensitive to a
quarter of a degree temperature change and will activate/deactivate the boiler.
ON
+/-0.25
+/-0.5
2
Wall mounting
Fix the backplate
to the wall
Note: You can also use a flush mount housing and a German and UK wall box to mount the thermostat directly
into the wall. The standard wall box has a diameter max 60mm and depth from 41-46 mm. The cable entry on
the backplate must allow a cable with 5*1,5 mm
Align the front housing at
the top edge
.
Fit the front housing.
Press lightly
60mm
46mm
06 RT310 Installation Manual
Page 7
Button functions and keys
There are few user controls for the RT310, making this thermostat very easy to operate. These controls are
shown below, along with a description of each of their functions. The temperature displayed on the LCD is the
current room temperature. All the LCD icons with a description are shown below.
Thermostat RT310
KeyFunction
Turn on the LCD backlight
Turn On/Off the Frost Mode
RESET
Increase button
Decrease button
Press once to return factory settings
+
+
Press for 3 seconds all the buttons to enter Installer
Mode
Thermostat RT310 LCD
IconMeaning
Thermostat is calling for heat
Thermostat is in Frost Protect Mode
Low Battery Warning Indicator
Current Temperature/Set Point Temperature
RT310 Installation Manual 07
Page 8
Installer Mode
Press and hold and and keys to enter installation setting.
The first setting is temperature display resolution selection - d01. Press to enter the existing setting. The
setting will start flashing. Press or to change temperature display resolution, wait for 10 seconds to
confirm, then enter d02 (if you didn’t press to save your selection, the change will be confirmed after 10
seconds and the thermostat will return to normal mode). d02 is to set temperature offset, press or to
increase/decrease offset.
To exit Installer Mode don’t press any key for 10 seconds, or press
See the table below.
3 Sec
5
RESET
TESTING/PAIRING
RESET
3 Sec3 Sec
Press the three buttons
Enter first d01 setting. Press
Select increment. Press
together for 3 seconds.
Continue adjusting the d02 and d03 following the same steps as above.
Once you have finished setting up all the parameters, press to exit
2
TESTING/PAIRING
to home screen, or don’t press any button for 10 seconds and it will
exit automatically.
dxxFunctionParameterDescriptionDefault
value
d01Temperature display
increments
0.1°C or
0.5°C
Select the temperature display
increments
0.5°C
d02Temperature offset+/-3.0°CCalibrate your thermostat tempera-
d03Frost setpoint temperature5.0°C-17.0°CSet the Frost Point temperature5.0°C
08 RT310 Installation Manual
0.0°C
ture
Page 9
Operations
Initial Power UP
After power up, the thermostat is reset. During system reset, all LCD icons are displayed for 2 seconds and
the keys are locked. After that, all keys are unlocked and the thermostat is initialized. Then software version is
shown. The typical reset display is shown below.
The following table shows the settings of the RT310 digital thermostat after RESET button is pressed:
FunctionStatus after Reset
Operation ModeNormal mode
Room Temperature22.0°C, to be renewed within 5 seconds
Setpoint Temperature20.0°C
°C indicatorOn
Frost Protection indicatorOff
Heat indicatorOff
Low-Battery Warning indicatorOff, to be renewed within 5 seconds
Output RelayOff
Reviewing Setpoint Temperature
Press or to review Setpoint temperature. The flame icon won’t be turned on.
TESTING/PAIRING
Actual room temperature
Setpoint temperature
When operating in Frost protection mode, the LCD will show frost setpoint with the Frost Protection
indicator displayed.
Press Backlight or wait 2 seconds without keys pressed to return to normal operation, room temperature will
be displayed.
TESTING/PAIRING
RT310 Installation Manual 09
Page 10
Adjusting Setpoint Temperature
By changing the Setpoint temperature, you are permanently altering your temperature. You can change the
set point temperature very easily while you are reviewing the set point temperature. Press the UP or DOWN
keys repeatedly to change the temperature setting. The set point temperature will flash to indicate that it can
be changed: the temperature will be changed in 0.5°C steps per key press.
The RT310 will return to Normal mode if no keys are pressed for more than 2 seconds. Once the new Setpoint
is implemented, the change is permanently overridden until a new Setpoint is set again. Setpoint temperature
cannot be changed if Frost Protection mode is enabled.
TESTING/PAIRINGTESTING/PAIRING
TESTING/PAIRING
TESTING/PAIRING
Actual room temperatureSetpoint temperature2 seconds timeoutActual room temperature
Frost Protection
Press FROST button to activate Frost Protection.
The Setpoint temperature is automatically set to frost setpoint to prevent pipes from freezing. If the room
temperature is lower than the frost setpoint, frost protection will be enabled. When Frost Protection is enabled,
the user should not be able to press or adjust frost Setpoint temperature, this feature being accessible only in
installation mode. Please refer to page 7 on more information on Installer Mode. Press FROST button again
to de-activate Frost Protection.
Frost Protection ONFrost Protection OFF
Actual room temperatureFrost Mode activated
Note: The setpoint frost temperature can be reviewed by pressing the Up button once, but can only be
changed in Installer Mode. For more information about entering Installer Mode, please refer to page 7
Frost Mode activated
10 RT310 Installation Manual
TESTING/PAIRINGTESTING/PAIRING
TESTING/PAIRING
TESTING/PAIRINGTESTING/PAIRING
Actual room temperature Frost Mode deactivated
TESTING/PAIRING
Frost setpoint temperature
Page 11
Other functions
LCD backlight
• LCD backlight is activated when or any key is pressed. The backlight will be turned off in 15 seconds
after all keys are released.
• LCD backlight will not operate when battery is low.
Low battery detection
Battery voltage is checked every minute. When the battery voltage drops to a certain level, the Low-Battery
warning indicator appears.
• The thermostat functions normally during low battery. However, user must change the batteries as soon
as possible before the battery is too weak for the normal operation to be assured.
• When you change the batteries, you have about 30 seconds to to do so without losing your settings.
Sleep Mode
Press and hold and for 3 seconds simultaneously to enter the Sleep mode. All the functions will be
paused to save battery power. While in sleep mode:
• The LCD display will be blank.
• All output from the Control Unit will be turned off immediately.
Press any key to wake up the RT310 and cancel SLEEP mode.
Sleep Mode OnSleep Mode O
RESET
3 Sec
3 Sec
TESTING/PAIRINGTESTING/PAIRING
TESTING/PAIRINGTESTING/PAIRING
Press any button to stop
the Sleep Mode
Temperatures outside operating range
Temperatures below 10 °C are displayed without the leading ‘0’. Temperatures exceeding the measurable range
will be indicated by ‘HI’ for temperatures above the upper limit, and ‘LO’ for temperatures below the lower limit,
as shown in the images.
RT310 Installation Manual 11
Page 12
Factory reset
Press the Reset button once. You can use a paper clip. Your
thermostat will be reset and will start up automatically.
Technical info
Product Specication
Model:RT310
Type:Wired Heating Thermostat
Temperature
Scale:°C
Range:5.0°C - 35.0°C
TESTING/PAIRING
Resolution:0.1/0.5°C and 0.5°C default
Temperature Measurement
SALUS Controls warrants that this product will be free from any defect in materials or workmanship, and shall
perform in accordance with its specification, for a period of two years from the date of installation. SALUS
Controls sole liability for breach of this warranty will be (at its option) to repair or replace the defective product.
................................................................................................................ Post Code: ...............................................................
Tel No: ................................................................... Email: ......................................................................................................
Company Name: ...................................................................................................................................................................
Tel No: .................................................................. Email: ........................................................................................................
Maintaining a policy of continuous product development, SALUS Controls plc reserves the right to
change specification, design and materials of products listed in this brochure without prior notice.
Issue Date: April 2017, V001
Loading...
+ hidden pages
You need points to download manuals.