RYi2300BT/RYI2300BTA QUICK REFERENCE GUIDE
WARNING:
This Quick Reference Guide is not a substitute for reading the operator’s manual. To reduce the risk of injury or death, user must read and understand operator’s manual before using this product. All page references refer to
the operator’s manual.
IMPORTANT!
WARNING:
Do not connect to a building’s electrical
system unless the generator and transfer
switch have been properly installed and
the electrical output has been verified by
a qualified electrician. The connection
must isolate the generator power from
utility power and must comply with all
applicable laws and electrical codes.
FIRST TIME STARTING THE UNIT
Add entire bottle of lubricant provided to the generator (see page 13).
1
1
Using a generator indoors CAN KILL YOU IN MINUTES.
Generator exhaust contains carbon monoxide. This is a
poison you cannot see or smell.
NEVER use inside a home
or garage, EVEN IF doors
and windows are open.
Only use OUTSIDE and
far away from windows,
doors, and vents.
FIRST TIME STARTING THE UNIT (CONTINUED)
Pull the starter grip until the engine runs (see page 14).
4
Allow engine to run for 15-30 seconds, then move Easy Start dial to RUN/
5
RE-START (middle) position (see page 14).
USING THE GENERATOR
Connect devices to be powered by generator by following the steps below (see pages 8-9).
1
• Make sure the generator can supply enough continuous (running) and surge (starting) watts for the items you
will power at the same time. See page 9 for how to calculate total amount of power needed.
• Start the generator with nothing connected.
• Plug in and turn on the first load, preferably the largest load you have.
• Permit the generator output to stabilize (engine runs smoothly and attached device operates properly).
• Plug in and turn on the next load.
• Again, permit the generator to stabilize.
• Repeat previous two steps for each additional load.
IMPORTANT: Never add more loads than the generator capacity. Take special care to consider surge loads in
generator capacity. (See pages 8-9.)
STORING THE UNIT
When preparing to store the generator, allow the unit to cool for 30 minutes, then follow the guidelines listed on
1
1
page 17.
TROUBLESHOOTING
2
Place Easy Start dial to the COLD START (top) position (see page 14).
STOPPING THE UNIT
1
Place Easy Start dial to the OFF/STORAGE (bottom) position (see page 14).
PROBLEM POSSIBLE CAUSE SOLUTION
Engine will not start. Easy Start dial is in OFF/STORAGE or
RUN/RE-START position.
No fuel.
Stale gasoline or water in gasoline.
Lubricant level is low.
Spark plug faulty, fouled, or improperly
gapped.
Engine stored without treating or draining
gasoline, or refueled with bad gasoline.
Dirty fuel filter.
Engine hard to start. Water in gasoline.
Weak spark at spark plug.
Engine lacks power. Engine stored without treating or draining
gasoline, or refueled with bad gasoline.
Dirty air filter.
AC receptacle does not work. Item plugged in is defective.
Move Easy Start dial to COLD START
position.
Fill fuel tank.
Drain entire system and refill with fresh
fuel.
Engine is equipped with Low Oil Shutoff.
If engine lubricant level is low, it must be
filled before unit will start. Check engine
lubricant level and fill, if necessary.
Replace spark plug.
Drain fuel and carburetor. Refuel with
fresh gasoline.
Contact a qualified service center.
Drain entire system and refill with fresh
fuel.
Replace spark plug or contact a
qualified service center.
Drain fuel and carburetor. Refuel with
fresh gasoline. If problem continues,
contact a qualified service center.
Clean or replace as needed.
Try a different item.
3
Add fuel (see page 13).
NOTICE:
Do not use E15 or E85 fuel in this product. It is a
violation of federal law and will damage the unit
and void your warranty. Only use unleaded gasoline containing up to 10% ethanol.
GENCONTROL™ APP WITH BLUETOOTH
From the app store on your iOS or Android Bluetooth® enabled device, locate and install the RYOBI
1
GENCONTROL™ app. See page 14 for more details.
®
Generator is overloaded.
If problem persists after trying the above solutions, contact customer service or a qualified service center for assistance.
Remove loads and press the reset button.
NOTICE:
As the equipment owner, you are responsible for the performance of the required maintenance listed in the Maintenance
section. It is recommended that you retain all receipts covering maintenance on your equipment. Neglecting or failing to
perform the required maintenance may increase emissions, decrease fuel efficiency, degrade performance, cause irreversible
engine damage and/or void your warranty.
Make the most of your purchase! Go to
www.ryobitools.com and register your new tool online.
For questions about operating or maintaining
your product, please call 1-800-860-4050.
991000964
6-6-17 (REV:02)