2
“WARNING” “ TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT
EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE.”
“CAUTION” “ TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER. NO USER - SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALI­FIED SERVICE PERSONNEL.
The lightning flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsu­lated “dangerous voltage” within the products enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompa­nying the appliance.
SAFETY INSTRUCTIONS
1. Read Instructions - All the safety and operating instructions should be read before the appliance is operated.
2. Retain Instructions - The safety and operating instructions should be retained for future reference.
3. Heed Warnings - All warnings on the appliance in the operating instructions should be adhered to.
4. Follow Instructions - All operating and user instructions should be followed.
5. Water and Moisture - Do not use this appliance near water, for example, near a bathtub, washbowl, kitchen sink, laundry tub, in a wet basement, or near a swimming pool. Do not expose the appliance to dripping or splashing, and do not place on the appliance objects filled with liquids such as vases. Do not touch the amplifier with wet hands. Do not handle the amplifier or power cord when your hands are wet or damp. If water or any other liquid enters the amplifier cabinet, take the amplifier to qualified service personnel for inspec­tion.
6. Cleaning - The appliance should be cleaned only as recommended by the manufacturer. From time to time you should wipe off the front and side pan­els and the cabinet with a soft cloth. Do not use rough material, thinners, alcohol or other chemical solvents or cloths since this may damage the finish or remove the panel lettering.
7. Ventilation - The appliance should be situated so that its location or position does not interfere with its proper ventilation. For example, the appliance should not be situated on a bed, sofa, rug, or similar surface that may block the ventilation openings or, placed in a built - in installation, such as a book­case or cabinet that may impede the flow of air through the ventilation open­ings. Place the unit in a well-ventilated location, leaving at least 2 inches (5 cm) of clearance on all sides, top and rear of unit for air flow. If ventilation is blocked, the unit may overheat and malfunction.
8. Heat - The appliance should be situated away from heat sources such as radi­ators, heat registers, stoves, or other appliances ( including amplifiers ) that produce heat.
9. Grounding or Polarization - Precautions should be taken so that the grounding or polarization means of an appliance is not defeated.
10.Power Cord Protection - Power supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them, paying particular attention to cords at plugs, receptacles, and the point where they exit from the appliance.
11.Power Sources - The appliance should be connected to a power supply only
of the type described in the operating instructions or as marked on the appli­ance.
12.Main Power Disconnect - The power switch is a single-pole switch. When the switch is in the “Off” position, the appliance is not completely disconnected from the main power. The main power plug is used as the disconnect device and shall remain readily operable. When installing the product, ensure that the plug is easily accessible.
13.Non-use Periods - The power cord of the appliance should be unplugged from the outlet when left unused for a long period of time.
14.Attachments - Only use attachments/accessories specified by the manufac­turer.
15.Carts and Stands - The appliance should be used only with a cart or stand that is recommended by the manufacturer. An appliance and cart combination should be moved with care. Quick stops, excessive force and uneven surfaces may cause the appliance and cart combination to overturn.
16.Wall or ceiling Mounting - The appliance should be mounted to a wall or ceil­ing only as recommended by the manufacturer.
17.Location of the Amplifier - Do not mount this unit under a kitchen cabinet. Do not expose the amplifier to direct sun light or heating units as the amplifier internal components’ temperature may rise and shorten the life of the compo­nents. Avoid damp and dusty places.
18.Object and Liquid Entry - Care should be taken so that objects do not fall and liquids are not spilled into the enclosure through the openings.
19.Servicing - The user should not attempt to service the appliance beyond that described in the operating instructions. All other servicing should be referred to qualified service personnel.
20.Damage Requiring Service - The appliance should be serviced by qualified service personnel when:
A. The power - supply cord or the plug has been damaged; or B. Objects have fallen, or liquid has been spilled into the appliance; or C. The appliance has been exposed to rain; or D. The appliance does not appear to operate normally; or E. The appliance has been dropped or the enclosure is damaged.
IMPORTANT SAFEGUARDS
3
INTRODUCTION
The Russound R1250MC is a 12-channel power amplifier and is ideal for use as the main amplifier in home theater and distributed audio systems. The 12 channels are arranged in pairs to provide amplification for six stereo zones. The R1250MC provides an array of useful fea­tures such as bridge mode operation, independent zone triggering, bus inputs and multiple speaker outputs per zone to meet a wide variety of applications and configu­rations.
The R1250MC is rated at 50 watts per channel into 8 ohms and 80 watts per channel into 4 ohms. With the Stereo/Bridge Mono switch in the Bridge mode position, both channels in the zone are combined fora higher pow­ered mono output. In bridged mode, the R1250MC pro­vides 140 watts of power into a single 8-ohm load. All this power is backed by three high output toroidal trans­formers. Each amplifier output channel incorporates robust protection circuitry for safety and reliability under extreme circumstances.
FRONT PANEL
RACK MOUNTING
The R1250MC amplifier can be rack mounted using the included rack-mount ears and hardware to attach the ears to the amplifier. The amplifier will take 3 rack spaces with the feet removed.
s
R1250MC AMPLIFIER
Zone Indicator LEDs: The six LEDs correspond to the six stereo zone amplifiers. The LED will illuminate red
when the amplifier power is on and the zone is in standby. The LED will illuminate green when the zone is active.