Russound PIM User Manual

R–R–L–L+R+R–L–L+
OUTPUT INPUT
SPEAKERS SPEAKERS
SPEAKERS
INPUT
SPEAKERS
12V+(RED)
GND1(BLACK)
GND2(BLACK)
(YELLOW)
Smart Select
4 conductor,
22AWG 2 twisted
pair wire with sheild
T o speakers
and connecting
block (figure 1)
12V 1000mA power supply
pt. No. 846XP
Smart Select
Volume Control
EZB-1, 4-Way
Connecting
Block
T o other Smart
Select
Volume
Controls
Figure 1.

Product Overview

The Smart Select Power Interrupter is an accessory to the Smart Select system. The Smart Select Power Interrupter conditions the +12VDC power supply for reliable operation of the Smart S elect system.
Connection Instructions
1. Read the Smart Select Volume Control manual. It is important that you are Familiar with the operation and connection of the Smart Select Volume Controls.
2. Make sure the 1201A Power Supply is not plugged into a 110VAC Receptacle.
3. Use 2 conductor, 22-18 AWG hook-up wire to make power connections.
4. Strip 1/4” of insulation from both ends of the power and ground wire that
will be connected between the Smart Select Power Controller and the EZB-1 Connecting Block.
5. Connect the Smart Select Power Interrupter to the EZB-1 connecting block as shown in Figure 1. The +V connection from the Smart Select Power Interrupter should connect to the terminal of the EZB-1 which corresponds to the +12V connection of the Smart Select Volume Controls. The GND Connection from the Smart Select Power Interrupter should connect to the Terminal of the EZB-1 which corresponds to the GND 1 connection of the Smart Select Volu me Controls.
NOTE: The EZB-1 and EZB-2 connecting blocks have connectors that are Labeled L+, L-, R-, R+. You will need to make connections to the connecting block using alias names (i.e. 12v=L+, GND1=L-, GND2=R-, Data=R+).
6. To elimina te the risk of damaging one or more components of the Smart Select system, make sure that all connections are correct ant that no wires are shorted.
7. Connect the 1201A Power Supply to the input jack on the Smart Select Power Controller as shown in Figure 1.
8. Plug the 1201A Power Supply into a switched or unswitched 110VAC receptacle. It is recommended that the 1201A Power Supply be plugged into a switched 110VAC receptacle, provided with most stereo or home theater receivers.
5 Forbes Rd. Newmarket, NH 03857, USA
603.659.5170 • Fax 603.659.5388
e-mail: tech@russound.com
Come visit us at:

Limited Warranty

The Russound Smart Select Power Interrupter is fully guaranteed for Two (2) years from the date of purchase against all defects in materials and workmanship. During this period Russound will replace any defective parts and correct any defect in workmanship without charge for either parts or labor. For this warranty to apply, the unit must be installed and used according to its written instructions. If service is necessary, it must be performed by Russound. The unit must be returned to Russound at the owners expense and with prior written permission. Accidental damage and shipping damage are not considered defects under the terms of the warranty. Russound assumes no responsibility for defects resulting from abuse or servicing performed by an agency person not specifically authorized in writing by Russound. Damage to or destruction components due to improper use voids the warranty. In these c ases the repair will be made at the owner’s expense. To return for repairs, the unit must be shipped to Russound at the owner’s expense, along with a note explaining the nature of the service required. Be sure to pack in a corrugated container with at least 3 inches of resilient material to protect the unit from damage in transit.
Smart Select Power Interrupter Instruction Manual
1/16/01
Loading...