DTS1 Desktop Stand Installation
Introduction
The DTS1 Desktop Stand is an accessory for the KLK-E5
and MDK-C5 keypads. It provides a standalone form to
use the keypad “o the wall.”
The DTS1 has a non-skid base and weighted body to
keep the unit steady during keypad use. It includes a
terminated CAT-5 cable that attaches to the keypad’s
controller port. A patch cable (not included) connects
an RJ45 port on the back of the DTS1 to a keypad port
on the controller.
Considerations
The AUX port on the KLK-E5 is unavailable when the •
keypad is installed in the DTS1.
The External IR Input connector on the KLK-E5 and •
MDK-C5 is unavailable for use with the DTS1.
The DTS1 stand with an installed keypad is •
designed to be placed on, and operated from a
at level surface such as a countertop, end table or
nightstand. It is not meant to be a portable device,
and should not be picked up and hand-held during
use or carried from place to place.
The DTS1 requires a CAT-5 patch cable to connect •
it to the controller. This patch cable should be cut
to t the installation, and be kept away from foot
trac areas so it is not walked on or tripped over.
The stand with keypad is for inside use only and •
must be protected from the weather. Do not use
near or in water, such as a hot tub, kitchen sink or
master bathroom.
Keypad Assembly
Center the mounting bracket over the front of the 1.
DTS1 body. The screw holes should line up and the
locking tabs should face out.
Connect the CAT-5 cable to the Controller port of 2.
the keypad. Tuck the cable behind the keypad and
Page 1 of 2
install the keypad, aligning screw holes.
Install the four screws to join the keypad, bracket 3.
and body. Hand tighten only, do not use a drill.
Snap the bezel onto the front of the assembly. 4.
Page 2 of 2
DTS1 Desktop Stand Installation (continued)
Connection to Controller
On the bottom of the DTS1, remove the two screws and the strain relief plate.1.
Connect a CAT-5 patch cable (T568A) to the RJ45 port. Connect the other cable end to the controller’s keypad 2.
port. A wall plate can be used for a cleaner installation. There should be no more than 250 feet of CAT-5 from the
controller to the keypad.
Replace the plate and screws. The CAT-5 cable should be held securely without being pinched.3.
Technical Specications
Dimensions: 5.92”W x 5.38"D x 4.68"H
(152 x 138 x 120 mm)
Weight: 1.93 lbs (0.87 kg)
CAT-5 Connection: RJ45 (T568A wiring standard)
©2009 Russound. All rights reserved.
All trademarks are the property of their respective owners.
Specications are subject to change without notice.
Russound is not responsible for typographical errors or omissions.
Russound, Inc.
5 Forbes Road, Newmarket, NH 03857
tel603.659.5170•fax603.659.5388
email: tech@russound.com www.russound.com
28-1347 07/06/09