Russell H-D300L22 User Manual

1/2 to 3 HP
4 to 6 HP
MEA
MiniCon - H Series
Air Cooled Condensing Units 1/2 to 6 HP Brochure 502.12 rev.5
Our newly re-designed condensing unit is:
installation friendly
service friendly
compact and efficient
NOW AVAILABLE
THROUGH 6 HP
H L D 500 H 22 —E
Description
Options
Nomenclature
Refr
igerant Type 22 = R-22 44 = R-404A / 507
T
emperature Range (varies by unit) H = High /Medium (0° to 55°S.T.) M = Medium (-10° to 45° S.T.) L = Low (-40° to 25° S.T.)
Horsepo
wer 050 = 1/2 HP 075 = 3/4 HP 100 = 1 HP 101 = 1 HP 150 = 1-1/2 HP 151 = 1-1/2 HP 165 = 1-1/2 HP 200 = 2 HP 201 = 2 HP 202 = 2 HP
215 = 2 HP 250 = 2 HP 251 = 2HP 300 = 3 HP 301 = 3 HP 315 = 3 HP 400 = 4 HP 401 = 4 HP 500 = 5 HP 600 = 6 HP 650 = 6-1/2 HP
HTP MiniCon H-Series
Model Style L = Outdoor Flooded Model
Compressor
Type S = Semi-Hermetic H = Hermetic D = Discus O = Scroll
Voltage code
C=230/60/1 D= 208-230/60/1 E= 208-230/60/3 G= 460/60/3
Indoor/Outdoor Models (HLH / HLS / HLD / HLO)
• Hermetic, Semi-hermetic, Discus or Scroll compressor.
• Generously sized condenser, Copper tubes/Aluminum fins
• Large electrical control panel for power and control circuits
• Compressor contactor or start kit
• Encapsulated high and low pressure controls (adjustable low pressure control on low temp models)
• Refrigerant receiver with shutoff valve and relief plug
• All-weather housing
• Liquid line kit with filter/drier and sight glass with moisture indicator
• Suction line piping to exterior of cabinet
• Low Ambient - flooded head pressure control valve
• Crankcase heater
• Electric defrost timer with defrost contactor/relay on low
temperature models (ED10-230/1)
• Air Defrost Timer (2-1/2 through 6 HP High and Medium temp
models only, optional for other HP)
• UL and C-UL listed for indoor or outdoor use
• Wire fan guard(s) kit
• Suction filter (Loose)
• Suction accumulator (Loose)
• Oil separator (Loose)
• Crankcase heater (Loose)
• Tiered stacking
• Liquid line solenoid (Loose)
• Fused disconnect (Loose)
HTP H-Series condensing units are ideally suited for use
in a variety of commercial applications such as cafeterias,
convenience stores, restaurants and fast food outlets. H -Series units offer a winning combination of quality, econo­my, and flexibility coupled with lower long term operating costs.
This low profile product line has been designed around environmentally safer refrigerants. All models utilize R-22 or R-404A. Units are available with a choice of compressors: low cost hermetic and scroll or heavy duty semi-hermetic and discus.
In addition to the basic Indoor and Outdoor models described in this bulletin, HTP can also provide pre-engi­neered system packages with matching evaporators and accessories.
These HTP condensing units are designed for operation in ambient air temperatures up to 110°F. Oversized con­densers are available for most models. Contact our Applications Engineering department for requirements exceeding 110°F ambient temperature.
Features
2
DESCRIPTION HLH HLD HLS HLO
Hermetic STD N/A N/A N/A
Discus N/A STD N/A N/A
Semi-Hermetic N/A N/A STD N/A
Scroll N/A N/A N/A STD
Oil failure control (as required) N/R STD STD N/R
Encapsulated high and low pressure controls**
Compressor contactor (1Ø or 3Ø), start kit (1Ø)
Control transformer (460v to 230V) as required
Copper tubes , Aluminum fins
Fan motor(s) - overload protection
Fan blade(s) - individually balanced
Suction line ( vibrasorber† and piping only)
*Liquid line kit
Discharge vibrasober N/R STD†† STD†† N/R
Shut-off valve(s)
Fusible plug
Galvanized steel all weather housing
Control panel
CONTROLS
Flooded head pressure control
Air defrost time clock
Electric defrost package (1) (1) (1) (1)
UL and C-UL listed
Leak and dielectric tested before shipping
Dry Nitrogen shipping charge (25 to 35 PSI)
RECEIVER
HOUSING
DEFROST
PROVISIONS
TESTING
STANDARD
STANDARD
STD on 3-6 HP
STANDARD
STANDARD
STANDARD
STANDARD
STANDARD
STANDARD
STANDARD
STANDARD
STANDARD
PACKAGED UNITS
STANDARD
STANDARD
STANDARD
STANDARD
STANDARD
COMPRESSOR
ELECTRICAL
CONTROLS
CONDENSER
PIPING
COMPONENTS
Features and Options
STD = Standard Feature N/R = Not Required N/A = Not Available
3
† Vibrasorber not required for Hermetic and Scroll compressors.Vibrasorber not included for 1/2 through 2HP models, Add optional kit
SPR-VB if suction vibrasorber required. ††Standard for 2-1/2 through 6HP Models. For 1/2 to 2HP models, add kit number SPR-VB to include vibrasorbers and compressor spring mounting. *Liquid line kit includes: piping, filter drier, sight glass/moisture indicator. ** Adjustable low pressure control on low temp models in lieu of fixed control. (1) Electric defrost kit is included on Low temperature models. ED-10-230/1 for 1/2 to 3 HP models, and ED11-230/3 for 4 to 6 HP models.
1/2 through 3 HP
4 through 6 HP
Loading...