Russell D600M44 User Manual

201 Thomas French Drive, Scottsboro AL 35769 • Tel (714) 529-4461 • FAX (714) 529-8503 http://coldzone.htpgusa.com
1/2 to 3 HP
4 to 6 HP
UNI-PAK
R404A/R22 Dual Refrigerant Air Cooled Condensing Units 1/2 to 6-1/2 HP Brochure 502.18
May, 2013
Description
Options
Indoor/Outdoor Models (IR-H/IR-S/IR-D/IR-O)
• Hermetic, Semi-hermetic, Discus or Scroll compressor.
• Generously sized condenser, Copper tubes/Aluminum fins
• Large electrical control panel for power and control circuits
• Compressor contactor or start kit
• Encapsulated high and low pressure controls (adjustable low pressure control on low temp models)
• Refrigerant receiver with shutoff valve and relief plug
• PSC motors are standard for all condenser fans
• All-weather housing
• UL and cUL listed for indoor or outdoor use
Optimized Package (OR-H /OR-S /OR-D/OR-O)
• Includes all Indoor model features - plus:
• Crankcase heater
• Liquid line kit with filter/drier and sight glass with moisture indicator
• Suction line piping to exterior of cabinet
• Low Ambient - flooded head pressure control valve
• Electric defrost timer with defrost contactor/relay on low
temperature models (ED10-230/1)
• Air Defrost Timer (2-1/2 through 6 HP High and Medium temp
models only, optional for other HP)
• Factory installed air defrost timer
• Factory installed electric defrost timer with contactor
• Low ambient flooded control (STD on Outdoor models)
• Mild ambient fan cycle control (for 2 fan units only)
• Wire fan guard(s) kit
• Suction line piping to exterior of cabinet (STD on Outdoor units)
• Suction line kit with filter and piping
• Liquid line (piping only)
• Liquid line kit with piping, filter/ drier and sight glass (STD on Outdoor models)
• Suction accumulator
• Oil separator (not available with mounted accumulator)
• Crankcase heater
• Copper fins, or coated condenser coil
• Tiered stacking rack
• Liquid line solenoid
• Fused disconnect
• High ambient oversized condenser coil - contact Applications
• Spring mounting for semi-hermetic compressors
Uni-Pak condensing units are ideally suited for use in a variety of commercial applications such as cafeterias, convenience stores, restaurants and fast food outlets. Uni-Pak units offer a winning combination of quality, economy, and flexibility coupled with lower long term operating costs.
This low profile product line has been designed around environmentally safer refrigerants. Units are available with a choice of com-
pressors: low cost hermetic, efficient and quiet scroll compressors or heavy duty semi-hermetic and discus compressors.
In addition to the basic Indoor and Outdoor modelsdescribed in this bulletin, ColdZone can also provide pre-engineered system pack-
ages with matching evaporators and accessories.
The standard Uni-Pak condensing unit is designed for operation in ambient air temperatures up to 110°F. Oversized condensers are
available for most models. Contact our Applications Engineering department for requirements exceeding 110°F ambient temperature.
Features
Features and Options
2
STD = Standard Feature N/R = Not Required N/A = Not Available OPT = Optional Feature
† Vibrasorber not required for Hermetic and Scroll compressors. Vibrasorber not included for 1/2 through 2HP models. Add kit SPR-VB if suction vibrasorber required. ††Standard for 2-1/2 through 6HP Models. For 1/2 to 2HP models, add kit number SPR-VB to include vibrasorbers and compressor spring mounting. *Liquid line kit includes: piping, filter drier, sight glass/moisture indicator. ** Adjustable low pressure control on low temp models in lieu of fixed control. (1) Electric defrost kit is included on Low temperature models. ED-10-230/1 for 1/2 to 3 HP models, and ED11-230/3 for 4 to 6 HP models.
Features and Options
Nomenclature
3
I R H 055 M 44 D
Temperature Range (varies by unit) H = High/Medium (0° to 55°S.T.) M = Medium (-10° to 45° S.T.) L = Low (-40° to 25° S.T.)
S = COLDSAVER
I = INDOOR
O = OUTDOOR
R = Remote P = Precharged W = Water Cooled
Compressor T ype D = Discus S = Semi-Hermetic H = Hermetic G = Scroll
C = 230/1/60 (only) D = 208-230-60/1 E = 208-230/60/3 G = 460/60/3
Refrigerant T ype 22 = R22 44* = R404A / 507 * Some models can be used with R22 or R407C
Horsepower 055 = 1/2 HP 080 = 3/4 HP 090 = 1 HP 100 = 1 HP 125 = 1 HP 151 = 1-1/2 HP 165 = 1-1/2 HP 200 = 2 HP 215 = 2 HP
250 = 2 HP 251 = 2 HP 300 = 3 HP 301 = 3 HP 315 = 3 HP 400 = 4 HP 401 = 4 HP 500 = 5 HP 600 = 6 HP 650 = 6.5HP
COMPRESSOR
ELECTRICAL
CONTROLS
CONDENSER
PIPING
COMPONENTS
RECEIVER
HOUSING
AMBIENT
CONTROL
DEFROST
PROVISIONS
TESTING
DESCRIPTION
Hermetic STD N/A N/A N/A STD N/A N/A N/A
Discus N/A STD N/A N/A N/A STD N/A N/A
Semi-Hermetic N/A N/A STD N/A N/A N/A STD N/A
Encapsulated high and low pressure controls**
Compressor contactor (1Ø or 3Ø), start kit (1Ø)
Control transformer (460v to 230V) as required
Suction line ( vibrasorber
Suction kit (vibrasorber
Leak and dielectric tested before shipping
Dry Nitrogen shipping charge (25 to 35 PSI)
Oil failure control (as required) N/R STD STD N/R N/R STD STD N/R
Copper tubes, Aluminum fins
Fan motor(s) - overload protection
Fan blade(s) - individually balanced
, piping and suction filter)
Suction line accumulator
Galvanized steel all weather housing
Fan cycle control (2 Fan models only)
Flooded head pressure control
Electric defrost package (1) (1) (1) (1)
Fan guard(s)
and piping only)
*Liquid line kit
Discharge vibrasober N/R STD†† STD†† N/R N/R STD†† STD†† N/R
Shut-off valve(s)
Fusible plug
Control panel
Air defrost time clock
UL and C-UL listed
PACKAGED UNITSSTANDARD UNITS
IR*-H IR*-D IR*-S IR*-G OR*-H OR*-D OR*-S OR*-G
Scroll N/A N/A N/A STD N/A N/A N/A STD
STANDARD STANDARD
STANDARD STANDARD STANDARD
OPTIONAL
OPTIONAL OPTIONAL OPTIONAL OPTIONAL
STANDARD STANDARD
STANDARD STANDARD
OPTIONAL OPTIONAL
OPTIONAL OPTIONAL
STANDARD STANDARD STANDARD
STANDARD STANDARD STANDARDSTANDARD
STANDARD STANDARD STANDARD
OPTIONAL
STANDARD
OPTIONAL OPTIONAL
STANDARD
STANDARD STANDARD
STANDARD STANDARD
OPTIONAL
STANDARD
STD on 3-6 HP
STANDARD STANDARD STANDARD
4
Capacity Data - Medium Temp Hermetic R404A Rating
R404A MEDIUM TEMPERA TURE - HERMETIC - CAPACITY (BTUH)
90°F
Ambient
95°F
Ambient
100°F
Ambient
MODEL
*H055M44†
*H080M44†
*H090M44†
*H100M44†
*H125M44†
*H151M44
*H200M44
*H251M44
*H301M44
*H325M44
*H400M44
*H500M44
*H055M44†
*H080M44†
*H090M44†
*H100M44†
*H125M44†
*H151M44
*H200M44
*H251M44
*H301M44
*H325M44
*H400M44
*H500M44
*H055M44†
*H080M44†
*H090M44†
*H100M44†
*H125M44†
*H151M44
*H200M44
*H251M44
*H301M44
*H325M44
*H400M44
*H500M44
+30°F +25°F +20°F +10°F 0°F -10°F
-20°F -25°F
6,920 6,250 5,620 4,500 3,500 2,660 1,930 1,610 8,280 7,490 6,760 5,440 4,310 3,370 2,600 2,270
9,560 8,700 7,890 6,420 5,130 4,030 3,100 2,710 10,340 9,240 8,230 6,440 4,950 3,700 2,610 2,100 14,370 12,920 11,560 9,120 7,030 5,240 3,740 3,080 17,920 15,900 14,000 10,630 7,820 5,510 3,620 2,820 19,470 17,420 15,510 12,030 9,040 6,550 4,520 3,680 21,560 19,290 17,190 13,420 10,220 7,550 5,380 4,450 29,370 26,270 23,360 18,080 13,580 9,790 6,730 5,490 32,160 28,800 25,620 19,910 15,090 11,060 7,710 6,260 45,080 40,010 35,350 27,080 20,240 14,690 10,350 8,600 51,320 45,680 40,490 31,380 23,840 17,680 12,700 10,600
6,620 5,970 5,120 4,070 3,160 2,380 1,710 1,420
7,840 7,080 6,090 4,890 3,870 3,010 2,320 2,030
9,080 8,260 7,140 5,800 4,620 3,610 2,770 2,420
9,730 8,690 7,380 5,760 4,410 3,260 2,240 1,750 13,570 12,180 10,390 8,160 6,250 4,620 3,240 2,640 16,830 14,860 13,050 9,840 7,170 4,980 3,180 2,420 18,270 16,310 13,820 10,650 7,940 5,680 3,860 3,110 20,290 18,130 15,390 11,960 9,060 6,640 4,670 3,840 27,650 24,690 21,900 16,850 12,550 8,960 6,100 4,960 30,190 26,960 23,920 18,520 13,940 10,110 6,910 5,500 42,300 37,480 33,040 25,210 18,750 13,550 9,500 7,880 48,440 43,050 36,380 28,110 21,270 15,700 11,190 9,270
6,290 5,670 5,080 4,020 3,110 2,330 1,650 1,360
7,390 6,670 6,010 4,810 3,790 2,940 2,260 1,980
8,600 7,810 7,070 5,720 4,550 3,540 2,710 2,370
9,120 8,140 7,240 5,640 4,290 3,130 2,080 1,550 12,770 11,450 10,210 7,980 6,060 4,430 3,050 2,450 15,710 13,840 12,120 9,070 6,540 4,460 2,750 2,030 17,070 15,200 13,450 10,280 7,590 5,370 3,590 2,850 19,030 16,970 15,060 11,650 8,770 6,380 4,430 3,600 25,930 23,100 20,440 15,630 11,550 8,160 5,510 4,470 28,200 25,120 22,260 17,130 12,800 9,160 6,110 4,740 39,570 34,990 30,790 23,390 17,320 12,460 8,710 7,200 45,580 40,460 35,760 27,540 20,760 15,240 10,750 8,840
110°F
Ambient
*H055M44†
*H080M44†
*H090M44†
*H100M44†
*H125M44†
*H151M44
*H200M44
*H251M44
*H301M44
*H325M44
*H400M44
*H500M44
Models with † can be used with R407C between the ranges of 0°F and +30°F. Multiply capacity of models 055 thru 125 (only) by .83.
5,630 5,050 4,520 3,550 2,720 2,000 1,380 1,110
6,490 5,850 5,250 4,170 3,260 2,520 1,930 1,700
7,600 6,900 6,230 5,020 3,960 3,070 2,340 2,040
7,930 7,060 6,270 4,850 3,630 2,540 1,490 950 11,210 10,000 8,880 6,860 5,130 3,650 2,380 1,820 13,510 11,830 10,290 7,560 5,310 3,450 1,940 1,270 14,700 13,010 11,430 8,590 6,210 4,260 2,700 2,040 16,510 14,680 12,970 9,930 7,360 5,240 3,520 2,790 22,550 19,980 17,560 13,260 9,610 6,660 4,440 3,630 24,350 21,560 19,010 14,440 10,570 7,310 4,490 3,210 34,180 30,140 26,420 19,890 14,590 10,410 7,220 5,930 39,960 35,370 31,180 23,840 17,820 12,900 8,860 7,110