Russell CWF100 User Manual

Flow-Temp
Low Velocity Unit Cooler
Publication No. CZ-CWF-0312A March 2012
Visit us on the web at: http://coldzone.htpgusa.com
NSF
®
Flow-Temp low air velocity unit coolers are ideally suited for meat cutting, holding and
packing rooms as well as produce storage and florist boxes.
There are nine models available, ranging in capacity from 5,000 to 34,000 Btuh @ 10° TD
Rust free heavy gauge embossed Aluminum housing is standard. Optionally available with alternate materials and coatings.
Seamless enhanced Copper tubes are staggered and mechanically expanded into corrugated Aluminum fins assuring maximum heat transfer.
Optional Copper fins and fin coatings are available.
Available voltages: 115/1/60, 208/230/1/60, 460/1/60, 100/1/50, 200-220/1/50 and 380/1/50.
Fan motors and blades can be easily accessed by lowering the hinged drain pan.
Standard motors are permanently lubricated with thermal overload protection.
High efficiency EC motors are standard, PSC or shaded pole motors are optionally available.
All models are available in air, electric and hot gas defrosts designs.
Air defrost units are suitable for use in coolers down to 35°F.
Electric, Hot Gas Re-Evap and Hot Gas Reverse Cycle models are designed for use in rooms down to 28°F.
C W F 050 A E 1 B 1 1 A 1 A
I II III IV V VI VII VIII IX X XI XII XIII
Nomenclature
I. Brand Name
C – ColdZone
II. Unit type
W – Walk In Unit Cooler
III. Series
F – Low Air Velocity
IV. Capacity or Degree of Capacity –
050, 075, 100, 130, 160, 190, 220, 270, 340
V. Voltage Code
A – 115/1/60 D – 208-230/1/60 F – 460/1/60 L – 100/1/50 M – 200-220/1/50 P – 380/1/50 X – Other
VI. Motor/Fan Type
E – (EC) Electronically Commutated P – (PSC) Permanent Split Capacitor S – (SP) Shaded Pole X - Other
VII. Length in Fans
1, 2, 3, 4, 5, 6
VIII. Coil Density
B – 6 fpi X – Other
IX. Coil Material and Coating Options
1 – Aluminum fins (Al) 2 –- Copper fins (Cu) 3 – Al + AST coating 4 – Al + Blygold 5 – Al + Bronze Glow 6 – Al + Heresite 8 –- Al + Russ-Proof X – Other
NOTE:
Coil coatings are not available for electric defrost models
X. Housing Material Coatings
1 – Aluminum, Embossed 2 – Galvanized 3 – White Painted 6 – Stainless Steel 304 X – Other
XI. Unit Design Configuration
A – Air Defrost E – Electric Defrost G – Hot Gas Reverse Cycle Defrost with drain pan loop H – Hot Gas Re-Evaporative Defrost with drain pan loop K – Hot Gas Reverse Cycle Defrost with 115V heater L – Hot Gas Reverse Cycle Defrost with 208/230V heater X – Other
XII. Not Currently Used
1 – Standard
XIII. Revision Code – Single Alphanumeric Character
A – Current Revision
2