Russell ATFA114 User Manual

Publication No. RU-GLY-0315A
GLYCOL
UNIT COOLERS
Russell’s glycol unit coolers are the environmentally friendly solution to your refrigeration requirements. Offered in a variety of styles, these units are specifically designed for use with glycol mixtures and are ideally suited for storage coolers and freezers for restaurants, convenience stores, warehouses and supermarkets.
Glycol unit cooler performance is determined by the interaction of five distinct variables: entering air temperature, fluid temperature, GPM flow rate, glycol type and mixture percentage.
Contact Russell’s Application Engineering group to obtain optimal unit selections and precise capacity data based upon the specific requirements of your project.
Walk-In and Warehouse Models
Cooler & Freezer Applications
2
AT F 2* - 3 6 4 A E
Unit Size
Fins per Inch
GLYCOL UNIT COOLERS
LOW PROFILE - Electrical Data
Model
Number
Amps Watts Amps Watts Amps Watts Amps Watts
EC Motors PSC Motors Warm Fluid Def. Heater Amps
115V 230V 115V 230V
208/230V 460V
1 PH 1 PH
Watts
ATF*118 0.9 47 0.45 47 1.0 85 0.5 85 2.2 1.1 500 ATF*128 0.9 47 0.45 47 1. 0 85 0.5 85 2.2 1. 1 500 ATF*138 0.9 47 0.45 47 1. 0 85 0.5 85 2.2 1. 1 500 ATF*218 1.8 94 0.90 94 2.0 170 1.0 170 3.5 1. 8 800 ATF*228 1.8 94 0.90 94 2.0 170 1. 0 170 3.5 1. 8 80 0 ATF*238 1.8 94 0.90 94 2.0 170 1. 0 170 4.4 2.2 1,000 ATF*248 1.8 94 0.90 94 2.0 170 1. 0 170 3.5 1. 8 80 0 ATF*258 1.8 94 0.90 94 2.0 170 1. 0 170 4.4 2.2 1,000 ATF*318 2.7 141 1.35 141 3.0 255 1. 5 255 6.5 3.2 1,500 ATF*328 2.7 141 1.35 141 3.0 255 1.5 255 6.5 3.2 1,500 ATF*418 3.6 188 1.80 188 4.0 340 2.0 340 8.7 4.4 2,000 ATF*428 3.6 188 1.80 188 4.0 340 2.0 340 8.7 4.4 2,000 ATF*518 4.5 235 2.25 235 5.0 425 2.5 425 10.9 5.5 2,500 ATF*618 5.4 282 2.70 282 6.0 510 3.0 510 13.0 12.5 3,000 ATF*628 5.4 282 2.70 282 6.0 510 3.0 510 13.0 12.5 3,000
ATF*116 0.9 47 0.45 47 1.0 85 0.5 85 2.2 1.1 500 ATF*126 0.9 47 0.45 47 1. 0 85 0.5 85 2.2 1. 1 500 ATF*136 0.9 47 0.45 47 1. 0 85 0.5 85 2.2 1. 1 500 ATF*216 1. 8 94 0.90 94 2.0 170 1.0 170 3.5 1. 8 800 ATF*226 1.8 94 0.90 94 2.0 170 1. 0 170 3.5 1. 8 800 ATF*236 1.8 94 0.90 94 2.0 170 1. 0 170 4.4 2.2 1,000 ATF*246 1.8 94 0.90 94 2.0 170 1. 0 170 3.5 1. 8 800 ATF*256 1.8 94 0.90 94 2.0 170 1. 0 170 4.4 2.2 1,000 ATF*316 2.7 141 1.35 141 3.0 255 1. 5 255 6.5 3.2 1,500 ATF*326 2.7 141 1.35 141 3.0 255 1.5 255 6.5 3.2 1,500 ATF*416 3.6 188 1.80 188 4.0 340 2.0 340 8.7 4.4 2,000 ATF*426 3.6 188 1.80 188 4.0 340 2.0 340 8.7 4.4 2,000 ATF*516 4.5 235 2.25 235 5.0 425 2.5 425 10.9 5.5 2,500 ATF*616 5.4 282 2.70 282 6.0 510 3.0 510 13.0 12.5 3,000 ATF*626 5.4 282 2.70 282 6.0 510 3.0 510 13.0 12.5 3,000 ATF*114 0.9 47 0.45 47 1. 0 85 0.5 85 2.2 1. 1 50 0 ATF*124 0.9 47 0.45 47 1. 0 85 0.5 85 2.2 1. 1 500 ATF*134 0.9 47 0.45 47 1. 0 85 0.5 85 2.2 1. 1 500 ATF*214 1. 8 94 0.90 94 2.0 170 1.0 170 3.5 1. 8 800 ATF*224 1.8 94 0.90 94 2.0 170 1. 0 170 3.5 1. 8 800 ATF*234 1.8 94 0.90 94 2.0 170 1. 0 170 4.4 2.2 1,000 ATF*244 1.8 94 0.90 94 2.0 170 1. 0 170 3.5 1. 8 800 ATF*254 1.8 94 0.90 94 2.0 170 1. 0 170 4.4 2.2 1,000 ATF*314 2.7 141 1.35 141 3.0 255 1.5 255 6.5 3.2 1,500 ATF*324 2.7 141 1.35 141 3.0 255 1.5 255 6.5 3.2 1,500 ATF*414 3.6 188 1.80 188 4.0 340 2.0 340 8.7 4.4 2,000 ATF*424 3.6 188 1.80 188 4.0 340 2.0 340 8.7 4.4 2,000 ATF*514 4.5 235 2.25 235 5.0 425 2.5 425 10.9 5.5 2,500 ATF*614 5.4 282 2.70 282 6.0 510 3.0 510 13.0 12.5 3,000 ATF*624 5.4 282 2.70 282 6.0 510 3.0 510 13.0 12.5 3,000
1
* = A for air defrost, W for warm fluid defrost.
1. Warm fluid defrost models have electric drain pan heaters.
MODEL NUMBER NOMENCLATURE
Unit Style
Low Profile
Secondary Coolant
Defrost Type
A = Air defrost
W = Warm fluid defrost
Number of Fans
Motor Type
E = ECM P = PSC
Internal Circuits
Voltage Code
A = 115V D = 208-230/1/60 E = 208-230/3/60 F = 460/1/60
LOW PROFILE - Specications
3
GLYCOL UNIT COOLERS
Model
Number
ATF*118 1 800 2 19 27½ 33 ATF*128 1 770 2 19 27½ 34 ATF*138 1 740 2 19 27½ 36 ATF*218 2 1,460 2 33 41½ 48 ATF*228 2 1,420 2 33 41½ 51 ATF*238 2 1,540 2 37 45½ 58 ATF*248 2 1,380 2 33 41½ 60 ATF*258 2 1,480 2 37 45½ 63 ATF*318 3 2,310 2 55 63½ 79 ATF*328 3 2,220 2 55 63½ 84 ATF*418 4 3,080 3 36½ 36½ 81½ 254 ATF*428 4 2,960 3 36½ 36½ 81½ 262 ATF*518 5 3,850 3 54½ 36½ 99½ 312 ATF*618 6 4,620 4 36½ 36 36½ 11 7 ½ 354 ATF*628 6 4,440 4 36½ 36 36½ 11 7 ½ 370
ATF*116 1 830 2 19 27½ 41 ATF*126 1 800 2 19 27½ 44 ATF*136 1 780 2 19 27½ 47 ATF*216 2 1,540 2 33 41½ 54 ATF*226 2 1,500 2 33 41½ 55 ATF*236 2 1,600 2 37 45½ 62 ATF*246 2 1,460 2 33 41½ 59 ATF*256 2 1,560 2 37 45½ 67 ATF*316 3 2,400 2 55 63½ 78 ATF*326 3 2,340 2 55 63½ 85 ATF*416 4 3,200 3 36½ 36½ 81½ 255 ATF*426 4 3,120 3 36½ 36½ 81½ 265 ATF*516 5 4,000 3 54½ 36½ 99½ 306 ATF*616 6 4,800 4 36½ 36 36½ 11 7 ½ 353 ATF*626 6 4,680 4 36½ 36 36½ 11 7 ½ 368
ATF*114 1 870 2 19 27½ 42 ATF*124 1 840 2 19 27½ 46 ATF*134 1 830 2 19 27½ 49
ATF*214 2 1,630 2 33 41½ 51 ATF*224 2 1,590 2 33 41½ 52 ATF*234 2 1,670 2 37 45½ 59 ATF*244 2 1,550 2 33 41½ 56 ATF*254 2 1,650 2 37 45½ 64
ATF*314 3 2,500 2 55 63½ 76 ATF*324 3 2,470 2 55 63½ 83
ATF*414 4 3,330 3 36½ 36½ 81½ 252 ATF*424 4 3,290 3 36½ 36½ 81½ 261
ATF*514 5 4,160 3 54½ 36½ 99½ 299
ATF*614 6 4,990 4 36½ 36 36½ 11 7 ½ 351 ATF*624 6 4,940 4 36½ 36 36½ 11 7 ½ 365
Fan Data
Qty CFM A B C W
No. of
Hangers
Dimensions (Inches)
Ship
Wt.
(lbs.)
Connections
GPM
Range
.5 - 2.8 5/8 1/2
2.9 - 6.0 7/8 3/4
6.1 - 10 1-1/8 1
10.1 - 15 1-3/8 1-1/4
15.1 - 20 1-5/8 1-1/2
20.1 - 36 2-1/8 2
36.1 - 75 2-5/8 2-1/2
> 75.1 3-1/8 3
ODS SWT
MPT
Size
4
GLYCOL UNIT COOLERS
MEDIUM PROFILE - Electrical Data
Model
Number
ITF*218 2.4 1. 8 140 4.0 1.8 1. 0 282 7. 4 3.4 1,555/1,693
ITF*228 2.4 1. 8 140 4.0 1. 8 1. 0 282 7. 4 3.4 1,555/1,693
ITF*318 3.6 2.7 210 6.0 2.7 1.5 423 10.7 4.9 2,258/2,458
ITF*328 3.6 2.7 210 6.0 2.7 1.5 423 10.7 4.9 2,258/2,458
ITF*238 6.0 6.4 450 14.2 6.4 2.6 714 10.7 4.9 2,258/2,458
ITF*248 6.0 6.4 450 14.2 6.4 2.6 714 10.7 4.9 2,258/2,458
ITF*338 9.0 9.6 675 21.3 9.6 3.9 1,071 10.7 4.9 2,258/2,458
ITF*348 9.0 9.6 675 21.3 9.6 3.9 1,071 10.7 4.9 2,258/2,458
ITF*358 9.0 9.6 675 21.3 9.6 3.9 1,071 10.7 4.9 2,258/2,458
ITF*216 2.4 1. 8 140 4.0 1.8 1. 0 282 7. 4 3.4 1,555/1,693
ITF*226 2.4 1. 8 140 4.0 1. 8 1. 0 282 7. 4 3.4 1,555/1,693
ITF*316 3.6 2.7 210 6.0 2.7 1.5 423 10.7 4.9 2,258/2,458
ITF*326 3.6 2.7 210 6.0 2.7 1.5 423 10.7 4.9 2,258/2,458
ITF*236 6.0 6.4 450 14.2 6.4 2.6 714 10.7 4.9 2,258/2,458
ITF*246 6.0 6.4 450 14.2 6.4 2.6 714 10.7 4.9 2,258/2,458
ITF*336 9.0 9.6 675 21.3 9.6 3.9 1,071 10.7 4.9 2,258/2,458
ITF*346 9.0 9.6 675 21.3 9.6 3.9 1,071 10.7 4.9 2,258/2,458
ITF*356 9.0 9.6 675 21.3 9.6 3.9 1,071 10.7 4.9 2,258/2,458
ITF*214 2.4 1. 8 140 4.0 1.8 1. 0 282 7. 4 3.4 1,555/1,693
ITF*224 2.4 1. 8 140 4.0 1. 8 1. 0 282 7. 4 3.4 1,555/1,693
ITF*314 3.6 2.7 210 6.0 2.7 1.5 423 10.7 4.9 2,258/2,458
ITF*324 3.6 2.7 210 6.0 2.7 1.5 423 10.7 4.9 2,258/2,458
ITF*234 6.0 6.4 450 14.2 6.4 2.6 714 10.7 4.9 2,258/2,458
ITF*244 6.0 6.4 450 14.2 6.4 2.6 714 10.7 4.9 2,258/2,458
ITF*334 9.0 9.6 675 21.3 9.6 3.9 1,071 10.7 4.9 2,258/2,458
ITF*344 9.0 9.6 675 21.3 9.6 3.9 1,071 10.7 4.9 2,258/2,458
ITF*354 9.0 9.6 675 21.3 9.6 3.9 1,071 10.7 4.9 2,258/2,458
* = A for air defrost, W for warm fluid defrost.
1. Warm fluid defrost models have electric drain pan heaters.
Amps
EC Motors PSC Motors Warm Fluid Def. Heater Amps
115V
230V/1
Amps
EC
Watts
115V
Amps
230V/1
Amps
460v/1
Amps
PSC
Watts
208/230V
1 PH
460V
1 PH
Watts(460/230)
1
Unit Style
Medium Profile
Secondary Coolant
Defrost Type
A = Air defrost
W = Warm fluid defrost
Number of Fans
Unit Size
MODEL NUMBER NOMENCLATURE
IT F 2* - 3 6 4 A E
Motor Type
E = ECM P = PSC
Voltage Code
A = 115V D = 208-230/1/60 F = 460/1/60
Internal Circuits
Fins per Inch
Loading...
+ 8 hidden pages