Publication No. RU-GLY-0315A
GLYCOL
UNIT COOLERS
Russell’s glycol unit coolers are the environmentally
friendly solution to your refrigeration requirements.
Offered in a variety of styles, these units are specifically
designed for use with glycol mixtures and are ideally
suited for storage coolers and freezers for restaurants,
convenience stores, warehouses and supermarkets.
Glycol unit cooler performance is determined by
the interaction of five distinct variables: entering air
temperature, fluid temperature, GPM flow rate, glycol
type and mixture percentage.
Contact Russell’s Application Engineering group to
obtain optimal unit selections and precise capacity data
based upon the specific requirements of your project.
Walk-In and
Warehouse Models
Cooler & Freezer
Applications
2
GLYCOL UNIT COOLERS
LOW PROFILE - Electrical Data
Model
Number
Amps Watts Amps Watts Amps Watts Amps Watts
EC Motors PSC Motors Warm Fluid Def. Heater Amps
115V 230V 115V 230V
208/230V 460V
1 PH 1 PH
Watts
ATF*118 0.9 47 0.45 47 1.0 85 0.5 85 2.2 1.1 500
ATF*128 0.9 47 0.45 47 1. 0 85 0.5 85 2.2 1. 1 500
ATF*138 0.9 47 0.45 47 1. 0 85 0.5 85 2.2 1. 1 500
ATF*218 1.8 94 0.90 94 2.0 170 1.0 170 3.5 1. 8 800
ATF*228 1.8 94 0.90 94 2.0 170 1. 0 170 3.5 1. 8 80 0
ATF*238 1.8 94 0.90 94 2.0 170 1. 0 170 4.4 2.2 1,000
ATF*248 1.8 94 0.90 94 2.0 170 1. 0 170 3.5 1. 8 80 0
ATF*258 1.8 94 0.90 94 2.0 170 1. 0 170 4.4 2.2 1,000
ATF*318 2.7 141 1.35 141 3.0 255 1. 5 255 6.5 3.2 1,500
ATF*328 2.7 141 1.35 141 3.0 255 1.5 255 6.5 3.2 1,500
ATF*418 3.6 188 1.80 188 4.0 340 2.0 340 8.7 4.4 2,000
ATF*428 3.6 188 1.80 188 4.0 340 2.0 340 8.7 4.4 2,000
ATF*518 4.5 235 2.25 235 5.0 425 2.5 425 10.9 5.5 2,500
ATF*618 5.4 282 2.70 282 6.0 510 3.0 510 13.0 12.5 3,000
ATF*628 5.4 282 2.70 282 6.0 510 3.0 510 13.0 12.5 3,000
ATF*116 0.9 47 0.45 47 1.0 85 0.5 85 2.2 1.1 500
ATF*126 0.9 47 0.45 47 1. 0 85 0.5 85 2.2 1. 1 500
ATF*136 0.9 47 0.45 47 1. 0 85 0.5 85 2.2 1. 1 500
ATF*216 1. 8 94 0.90 94 2.0 170 1.0 170 3.5 1. 8 800
ATF*226 1.8 94 0.90 94 2.0 170 1. 0 170 3.5 1. 8 800
ATF*236 1.8 94 0.90 94 2.0 170 1. 0 170 4.4 2.2 1,000
ATF*246 1.8 94 0.90 94 2.0 170 1. 0 170 3.5 1. 8 800
ATF*256 1.8 94 0.90 94 2.0 170 1. 0 170 4.4 2.2 1,000
ATF*316 2.7 141 1.35 141 3.0 255 1. 5 255 6.5 3.2 1,500
ATF*326 2.7 141 1.35 141 3.0 255 1.5 255 6.5 3.2 1,500
ATF*416 3.6 188 1.80 188 4.0 340 2.0 340 8.7 4.4 2,000
ATF*426 3.6 188 1.80 188 4.0 340 2.0 340 8.7 4.4 2,000
ATF*516 4.5 235 2.25 235 5.0 425 2.5 425 10.9 5.5 2,500
ATF*616 5.4 282 2.70 282 6.0 510 3.0 510 13.0 12.5 3,000
ATF*626 5.4 282 2.70 282 6.0 510 3.0 510 13.0 12.5 3,000
ATF*114 0.9 47 0.45 47 1. 0 85 0.5 85 2.2 1. 1 50 0
ATF*124 0.9 47 0.45 47 1. 0 85 0.5 85 2.2 1. 1 500
ATF*134 0.9 47 0.45 47 1. 0 85 0.5 85 2.2 1. 1 500
ATF*214 1. 8 94 0.90 94 2.0 170 1.0 170 3.5 1. 8 800
ATF*224 1.8 94 0.90 94 2.0 170 1. 0 170 3.5 1. 8 800
ATF*234 1.8 94 0.90 94 2.0 170 1. 0 170 4.4 2.2 1,000
ATF*244 1.8 94 0.90 94 2.0 170 1. 0 170 3.5 1. 8 800
ATF*254 1.8 94 0.90 94 2.0 170 1. 0 170 4.4 2.2 1,000
ATF*314 2.7 141 1.35 141 3.0 255 1.5 255 6.5 3.2 1,500
ATF*324 2.7 141 1.35 141 3.0 255 1.5 255 6.5 3.2 1,500
ATF*414 3.6 188 1.80 188 4.0 340 2.0 340 8.7 4.4 2,000
ATF*424 3.6 188 1.80 188 4.0 340 2.0 340 8.7 4.4 2,000
ATF*514 4.5 235 2.25 235 5.0 425 2.5 425 10.9 5.5 2,500
ATF*614 5.4 282 2.70 282 6.0 510 3.0 510 13.0 12.5 3,000
ATF*624 5.4 282 2.70 282 6.0 510 3.0 510 13.0 12.5 3,000
1
* = A for air defrost, W for warm fluid defrost.
1. Warm fluid defrost models have electric drain pan heaters.
MODEL NUMBER NOMENCLATURE
Unit Style
Low Profile
Secondary Coolant
Defrost Type
A = Air defrost
W = Warm fluid defrost
Number of Fans
Motor Type
E = ECM
P = PSC
Internal Circuits
Voltage Code
A = 115V
D = 208-230/1/60
E = 208-230/3/60
F = 460/1/60
LOW PROFILE - Specications
3
GLYCOL UNIT COOLERS
Model
Number
ATF*118 1 800 2 19 — — 27½ 33
ATF*128 1 770 2 19 — — 27½ 34
ATF*138 1 740 2 19 — — 27½ 36
ATF*218 2 1,460 2 33 — — 41½ 48
ATF*228 2 1,420 2 33 — — 41½ 51
ATF*238 2 1,540 2 37 — — 45½ 58
ATF*248 2 1,380 2 33 — — 41½ 60
ATF*258 2 1,480 2 37 — — 45½ 63
ATF*318 3 2,310 2 55 — — 63½ 79
ATF*328 3 2,220 2 55 — — 63½ 84
ATF*418 4 3,080 3 36½ 36½ — 81½ 254
ATF*428 4 2,960 3 36½ 36½ — 81½ 262
ATF*518 5 3,850 3 54½ 36½ — 99½ 312
ATF*618 6 4,620 4 36½ 36 36½ 11 7 ½ 354
ATF*628 6 4,440 4 36½ 36 36½ 11 7 ½ 370
ATF*116 1 830 2 19 — — 27½ 41
ATF*126 1 800 2 19 — — 27½ 44
ATF*136 1 780 2 19 — — 27½ 47
ATF*216 2 1,540 2 33 — — 41½ 54
ATF*226 2 1,500 2 33 — — 41½ 55
ATF*236 2 1,600 2 37 — — 45½ 62
ATF*246 2 1,460 2 33 — — 41½ 59
ATF*256 2 1,560 2 37 — — 45½ 67
ATF*316 3 2,400 2 55 — — 63½ 78
ATF*326 3 2,340 2 55 — — 63½ 85
ATF*416 4 3,200 3 36½ 36½ — 81½ 255
ATF*426 4 3,120 3 36½ 36½ — 81½ 265
ATF*516 5 4,000 3 54½ 36½ — 99½ 306
ATF*616 6 4,800 4 36½ 36 36½ 11 7 ½ 353
ATF*626 6 4,680 4 36½ 36 36½ 11 7 ½ 368
ATF*114 1 870 2 19 — — 27½ 42
ATF*124 1 840 2 19 — — 27½ 46
ATF*134 1 830 2 19 — — 27½ 49
ATF*214 2 1,630 2 33 — — 41½ 51
ATF*224 2 1,590 2 33 — — 41½ 52
ATF*234 2 1,670 2 37 — — 45½ 59
ATF*244 2 1,550 2 33 — — 41½ 56
ATF*254 2 1,650 2 37 — — 45½ 64
ATF*314 3 2,500 2 55 — — 63½ 76
ATF*324 3 2,470 2 55 — — 63½ 83
ATF*414 4 3,330 3 36½ 36½ — 81½ 252
ATF*424 4 3,290 3 36½ 36½ — 81½ 261
ATF*514 5 4,160 3 54½ 36½ — 99½ 299
ATF*614 6 4,990 4 36½ 36 36½ 11 7 ½ 351
ATF*624 6 4,940 4 36½ 36 36½ 11 7 ½ 365
Fan Data
Qty CFM A B C W
No. of
Hangers
Dimensions (Inches)
Ship
Wt.
(lbs.)
Connections
GPM
Range
.5 - 2.8 5/8 1/2
2.9 - 6.0 7/8 3/4
6.1 - 10 1-1/8 1
10.1 - 15 1-3/8 1-1/4
15.1 - 20 1-5/8 1-1/2
20.1 - 36 2-1/8 2
36.1 - 75 2-5/8 2-1/2
> 75.1 3-1/8 3
ODS
SWT
MPT
Size
4
GLYCOL UNIT COOLERS
MEDIUM PROFILE - Electrical Data
Model
Number
ITF*218 2.4 1. 8 140 4.0 1.8 1. 0 282 7. 4 3.4 1,555/1,693
ITF*228 2.4 1. 8 140 4.0 1. 8 1. 0 282 7. 4 3.4 1,555/1,693
ITF*318 3.6 2.7 210 6.0 2.7 1.5 423 10.7 4.9 2,258/2,458
ITF*328 3.6 2.7 210 6.0 2.7 1.5 423 10.7 4.9 2,258/2,458
ITF*238 6.0 6.4 450 14.2 6.4 2.6 714 10.7 4.9 2,258/2,458
ITF*248 6.0 6.4 450 14.2 6.4 2.6 714 10.7 4.9 2,258/2,458
ITF*338 9.0 9.6 675 21.3 9.6 3.9 1,071 10.7 4.9 2,258/2,458
ITF*348 9.0 9.6 675 21.3 9.6 3.9 1,071 10.7 4.9 2,258/2,458
ITF*358 9.0 9.6 675 21.3 9.6 3.9 1,071 10.7 4.9 2,258/2,458
ITF*216 2.4 1. 8 140 4.0 1.8 1. 0 282 7. 4 3.4 1,555/1,693
ITF*226 2.4 1. 8 140 4.0 1. 8 1. 0 282 7. 4 3.4 1,555/1,693
ITF*316 3.6 2.7 210 6.0 2.7 1.5 423 10.7 4.9 2,258/2,458
ITF*326 3.6 2.7 210 6.0 2.7 1.5 423 10.7 4.9 2,258/2,458
ITF*236 6.0 6.4 450 14.2 6.4 2.6 714 10.7 4.9 2,258/2,458
ITF*246 6.0 6.4 450 14.2 6.4 2.6 714 10.7 4.9 2,258/2,458
ITF*336 9.0 9.6 675 21.3 9.6 3.9 1,071 10.7 4.9 2,258/2,458
ITF*346 9.0 9.6 675 21.3 9.6 3.9 1,071 10.7 4.9 2,258/2,458
ITF*356 9.0 9.6 675 21.3 9.6 3.9 1,071 10.7 4.9 2,258/2,458
ITF*214 2.4 1. 8 140 4.0 1.8 1. 0 282 7. 4 3.4 1,555/1,693
ITF*224 2.4 1. 8 140 4.0 1. 8 1. 0 282 7. 4 3.4 1,555/1,693
ITF*314 3.6 2.7 210 6.0 2.7 1.5 423 10.7 4.9 2,258/2,458
ITF*324 3.6 2.7 210 6.0 2.7 1.5 423 10.7 4.9 2,258/2,458
ITF*234 6.0 6.4 450 14.2 6.4 2.6 714 10.7 4.9 2,258/2,458
ITF*244 6.0 6.4 450 14.2 6.4 2.6 714 10.7 4.9 2,258/2,458
ITF*334 9.0 9.6 675 21.3 9.6 3.9 1,071 10.7 4.9 2,258/2,458
ITF*344 9.0 9.6 675 21.3 9.6 3.9 1,071 10.7 4.9 2,258/2,458
ITF*354 9.0 9.6 675 21.3 9.6 3.9 1,071 10.7 4.9 2,258/2,458
* = A for air defrost, W for warm fluid defrost.
1. Warm fluid defrost models have electric drain pan heaters.
Amps
EC Motors PSC Motors Warm Fluid Def. Heater Amps
115V
230V/1
Amps
EC
Watts
115V
Amps
230V/1
Amps
460v/1
Amps
PSC
Watts
208/230V
1 PH
460V
1 PH
Watts(460/230)
1
Unit Style
Medium Profile
Secondary Coolant
Defrost Type
A = Air defrost
W = Warm fluid defrost
Number of Fans
Unit Size
MODEL NUMBER NOMENCLATURE
IT F 2* - 3 6 4 A E
Motor Type
E = ECM
P = PSC
Voltage Code
A = 115V
D = 208-230/1/60
F = 460/1/60
Internal Circuits
Fins per Inch