Russell AA26-70B User Manual

All-Temp2BAll-Temp
Hi
h E
g
w avai
No
EC Motor
cy / Hi
en
ci
ffi
l
ab
e wi
l
h Rel
g
s
th
ab
i
Low Profile
ty
i
l
i
Unit Cooler
Publication No. 100.15 November, 2008
Air Defrost - 3,900 to 39,000 BTUH
Electric Defrost - 3,600 to 28,000 BTUH
Hot Gas Defrost - 3,600 to 28,000 BTUH
3050 Enterprise St. • P.O. Box 1030 • Brea, CA 92822-1030 • Tel: (714) 529-1935 • Fax: (714) 529-
Small to Medium Walk - Ins
Coolers & Freezer Applications
Visit us on the Web: www.russellcoil.com
7203
Features
KIT NO.
TIMER
AUXILIARY
SWITCH
BLOCK-OUT
RELAY
DEFROST
CONTACTOR
FAN
CONTACTOR
SEQUENCING
RELAY
ED10-230/1 1 1-30A ED11-230/3 1 1 1-30A ED12-460/3 1 1 1-30A 1-25A
1
ED210-230/1
1 1-30A
1
ED213-230/1
1 1 1-50A
1
ED213-230/3
1 1 1-50A ED20-230/1 1 1-30A 2 ED22-460/3 1 1 2-15A 1-25A 2 ED23-230/1 1 1 2-25A 2 ED23-230/3 1 1 2-25A 2 ED30-230/1 1 1-30A 3 ED32-460/3 1 1 3-10A 1-25A 3 ED33-230/1 1 1 3-16A 3 ED34-460/3 1 1 3-16A 1-25A 3 ED35-230/1 1 1 3-33A 3 ED35-230/3 1 1 3-33A 3
The Russell All-Temp²B is the original low profile unit cooler that has established an industry standard as being the all purpose design for walk-in coolers, freezers and other applications. They feature an air draw-through design offering air, electric and hot gas defrost models.
Si z e s
There are 35 sizes available with 3,700 to 39,000 BTUH
t a 10° TD ranging from 740 to 4,980 cfm. One through
a six fan models are available.
Ho u s in g
Rust-free, heavy gauge, textured Aluminum casing is light weight yet durable. Each fan section is baffled to prevent short cycling of the air. The unit is designed to mount flush to the ceiling and meets all NSF requirements. Slotted hangers are provided for easy installation. Drain fittings are installed in the horizontal position to gain more usable head­room in low ceiling applications. The end panels now are hinged to open up out for easy access to both the piping and electrical ends. Optional expansion valves can be conveniently installed inside the cabinet.
Co i l
Seamless Copper tubes are staggered and mechanically expanded into corrugated Aluminum fins and heavy gauge tube sheets to achieve maximum heat transfer and strength. Die formed fin collars provide even fin spacing. Fin spac­ings available are 4, 6, and 8 fins per inch. Sweat connections are standard on all models and optional field installed flare connection kits are available at no extra charge.
Mo t o rs
Shaded Pole motors are 1/20 HP, permanently lubricated, ball bearing, with thermal overload protection. Available in 115V, 208/230V and 460V, single phase. Optional high efficiency PSC and EC motors are available in 115V and 230V.
Fa n s
Heavy duty 12” Aluminum fans are balanced to provide vibration-free operation. Our new low throw black plastic fan guards have an improved air pattern. The optional epoxy resin high throw fan guard moves air up to 50 feet.
Ai r D e f ro st
All models with the prefix “AA” are designed for use in cool­ers of 35°F and warmer. Complete air defrost systems for off-cycle or timed air defrost are available from Russell.
• High efficiency PSC or ECM fan motors
• Coated Aluminum fins or Copper Fins
• Baked white enamel housing
Optional Features
El e c tr ical
Available in 115V, 208/230V, and 460V (see pages 4 & 5). All
omponents are factory wired to convenient screw-type
c terminal strips. A large compartment is supplied internal to the unit for all electrical components and is easily accessible by removing the end panel. All models are UL & cUL listed.
El e c tr ic Defr o s t
Available on all models with the prefix “AE”. Designed for use where electric heat is used to defrost. Placement of the heaters internal to the coil allows for an extremely rapid and efficient defrost. This arrangement enables the heat to be conducted through the fins from the center out for an even defrost pattern. All heaters are wired to a terminal strip to allow a quick field change-over from single phase to three phase, 230V to 460V and vice versa. A lower heater is installed close to the drain pan for fast, reliable drainage. A defrost termination thermostat (DT) terminates the defrost cycle when the temperature is satisfied. A heater safety thermostat is installed to prevent heaters from overheating above 75° in case of DT failure. All heaters are flexible and can be easily replaced within 12 inches of the end of the units. A fan delay thermostat is supplied to allow the warm coil to cool after a defrost cycle prior to the fans turning on. Complete electric defrost refrigeration systems are available from Russell.
Ho t G a s D e fr ost
Two types available - Re-Evap models with the prefix “AH” and reverse cycle with the prefix “AG”. All models include a fixed DTFD factory wired and a hot gas drain pan circuit to defrost the drain pan. On all Hot Gas models, the drain fit­ting is located on the left-hand rear of the unit when facing the fan guards. Re-evap models include a Heat Exchanger-Re-Evaporator shipped together with the unit for field installation. Complete Re-Evap Refrigeration Systems are available from Russell. Contact factory for piping information.
• Epoxy resin high throw guards for up to 50 ft.
• Reheat kits (not UL listed)
• Factory mounted expansion valves
2 7
All-Temp2B
!"#"$%
&'()*+
,#-%!"#"$
."/+$%
0(##12!#$
&'()*+%#"%
!"#"$%."/+$
0(##12!#$
3+-45+-
."/+$%
0(##12!#$
34)%
678+
9$12% :(;
!"#"$%
<)+$*;%
,(=7)*1
>0'2?$
!"#"$%
<)+$*;%
,(=7)*1
@2?$
3+-45+-
A"B%C"(-
!A6D2?$
&")-E%D)7#
<)+$*;%
,(=7)*1%%
@2?$
?+($F;%
,(=7)*%@
!"#$%&'
.(;%
G(5>%7)
?$1%
,. #"%.,& HIJ KL ML II IKH IK NLN HK () JEO .,&%#"%<& KL PQ MK II MJL MH HJPH IJ *+ IEJ
,! -. /0 +12 () )3 11 *45 *6 1222 34 6) +73
RUSSELLʼs EC motors
bring the benefits inherent to unit bearing motor design
to the refrigeration Unit Cooler market.
• Large oil resevoir
• Totally enclosed construction
• Journal bearing machined into the cast iron endbell
• Spiral grooved shaft pump guarantees positive oil circulation
• Threaded shaft uses hubless fan blade.
Energy Savings per Motor
by Changing to More Efficient Unit Cooler Motors (based on Energy Cost of $0.10 per kWh)
Subtract 6% from total savings for medium temperature air defrost units that run 24 hours per day. SP = 1/20 HP Shaded pole motor (Standard motors) PSC = 1/20 HP PSC motor (Optional motors available at additional cost) EC = 50 Watt Electronically Commutated motor (Optional motors available at additional cost)
Nomenclature
AA18 -41 B-A- E
All-Temp²B
Type of Defrost
Motor Type S = Shaded Pole E = ECM P = PSC
A = Air Defrost E = Electric Defrost H = Hot Gas Re-evap G = Hot Gas Rev. Cycle
Number of fans
Fins per inch
Revision Code
BTUH in hundreds
Voltage Code A = 115V B = 208/1/60 C = 230/1/60 D = 208-230/1/60 E = 208-230/3/60 F = 460/1/60