Solar Indirect Water Heater with Back-up Heating Element
A
F
D
H
G
E
C
B
1” NPT
TO
SOLAR
SENSOR
IMMERSION
WELL
ELECTRIC
HEATING
ASSEMBLY
COLD IN
3/4” NPT
PORT
T&P RELIEF
VALVE
1” NPT
FROM
SOLAR
ANODE
ANODE
HOT OUTLET
I
Available in 80 and 120 Gallon Models
10-Year Limited Tank Warranty*6-Year Limited Parts Warranty*
Incoloy 4.5 KW heating element
•
Single wall heat exchanger
•
-1/2" Porcelain coated internal coil
1
•
Brass drain valve
•
Two factory installed – heavy-duty
•
magnesium anode rods
Element position allows for 40
•
1" NPT connections
•
2" Non-CFC foam insulation
•
mmersion well for probe type
I
•
sensors
* See Residential Warranty Information
Brochure for complete warranty information.
gallons of hot water storage on the
80 gallon model and 50 gallons of
hot water storage on the 120 gallon
models
ESCRIPTION ROUGHING IN DIMENSIONS (SHOWN IN INCHES)
D
ODEL ELECTRIC OF SURFACE STORAGE WEIGHT
M
UMBER ELEMENT COILS (SQ. FT.) (GAL.)
N
RSID-80 4.5 KW 1 14.14 75 24 64 57-1/8 57-1/8 31-1/2 19-1/4 6-1/2 5 34-1/4 307
RSID-120 4.5 KW 1 14.14 110 28 65 57-3/4 57-3/4 33-3/4 16-1/4 8-3/4 6-1/2 36-1/4 407
arning: Installation should be in accordance with all national and/or local codes.
W
Caution: The recommended maximum hot water temperature setting for
ormal residential use is 120°F. Manufacturer recommends a tempering valve
n
or anti-scald valve be installed and used according to the manufacturer’s
directions to prevent scalding.
Pressures: (all) Working pressure, 150 psi; testing pressure, 300 psi
Electrical Rating: 4.5KW, 240V
NUMBER COIL SHIPPING
ABC D E F G H I (
LBS.)
PRESSURE DROP THROUGH COIL (Feet of H20)
Flow Rate 75 Gallon 110 Gallon
2 GPM .2 .2
3 GPM .3 .3
4 GPM .5 .5
5 GPM .6 .6
Head Loss (Feet)
In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.
Rheem Water Heating • 101 Bell Road, Montgomery, Alabama 36117 • www.rheem.com
P R I N T E D I N U. S.A 0 5 / 0 9 W P F O R M N O . 1 0 2 - 5 0