Rudd RPQL-024JAZ Installation Manual

FORM NO. P11-779 REV. 4
Supersedes Form No. P11-779 Rev. 3
The Rheem
Classic®Series
RPQL- Heat Pump Outdoor units can provide year-round heating and cooling comfort for residential, multi-family and light commercial applica­tions. They are designed to operate with Rheem indoor units with cooling and heating capacities certified under the AHRI Certification program.
The following additional features, plus its energy-saving characteristics, make the RPQL- Heat Pump outdoor units an excellent choice for new construction or upgrading your present system.
Attractive, louvered wrap around jacket protects coil from
weather extremes and yard hazards. Top grille is steel reinforced for extra strength. Cabinet is powder painted for all weather protection.
Four sided outdoor coil design allows compressor opera-
tion with access panel removed.
Air is discharged upward away from bushes and shrubs.
The discharge pattern of the top grille provides minimum air restriction, resulting in quiet fan operation.
Combination Grille/Motor Mount secures the fan motor to
the underside of the discharge grille.
All controls are accessible by removing one service
panel. Removable top grille provides access to the out­door fan motor and outdoor coil.
Compressor compartment offers additional protection
from the elements and reduces operating noise.
Single speed, 8-pole fan motor is designed for quieter,
energy-saving operation.
Non-cycling reversing valve and demand defrost.
All models meet or exceed a 1000-hour salt spray test per
ASTM B117 Standard Practice for Operating Salt Spray Testing Apparatus.
HEAT PUMPS
RPQL- JAZ
15 SEER Models Efficiencies up to 15.5 SEER/13 EER/10.45 HSPF Nominal Sizes 1
1
/2 to 5 Tons
[5.28 kW] to [17.6 kW]
Eight Models
Cooling Capacities 18,100 to 60,500 BTU/HR [5.30 kW] to [17.73 kW] HSPF up to 9.00
“Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps must be
matched with appropriate coil components to meet ENERGY STAR criteria. Ask your Contractor for details or visit www.energystar.gov.”
2 Rheem Heating, Cooling and Water Heating
All controls and compressor are accessible
for servicing by removal of the service panel.
Drawn Painted Base Pan.
Engineering Features
RPQL- Series Heat Pump Outdoor Unit
1. Scroll compressor is hermetically sealed and incorporates internal
high temperature motor overload protection, and durable insulation on the motor windings. It is externally mounted on rubber grommets to reduce vibration and noise.
2. Copper Tube/Aluminum Fin Coils—Both indoor and outdoor coils.
3. Strong, Attractive Cabinet—Constructed of powder painted steel.
Louvered design protects the coil from damage.
4. Internal Check Valve—Provides for more quiet refrigerant metering.
5. Enhanced Compressor Protection—Features an enhanced defrost control, auto-reset high pressure control, and auto-reset low pressure control to provide compressor protection under abnormally
high head pressure conditions (outdoor fan failure, restriction, dirty coil, etc.) or abnormally low suction pressure conditions (restrictions, TEV failure, loss of charge, indoor blower failure, etc.) while eliminat­ing nuisance tripping sometimes experienced with conventional control systems.
6. Drawn Painted Base Pan—For extra corrosion resistance and sound reduction.
7. Demand Defrost Control—Provides complete defrost when defrost is required.
8. Non-Cycling Reversing Valve—Eliminates discharge noises on each heating cycle.
9. Hot Gas Muffler—Reduces noise in heating cycle.
10. Bi-Directional Filter Drier—Standard on all models (shipped –
not installed).
11. Service valves are standard on all models.
12. Refrigerant Metering—TEV accurately meter refrigerant into indoor
and outdoor coils.
13. The RPQL- has a 10 year limited compressor warranty.
14. All refrigerant connections are on the exterior of the unit, located close
to the ground for neat appearing installations.
15. Coil design permits compressor operation with the access panel
removed.
16. Control box is fully accessible in the upper part of the cabinet, just
under the access panel.
17. Power and control wiring are kept separate.
18. Every unit is factory charged and tested.
R P Q L 018
COOLING
CAPACITY
018 = 18,000 BTU/HR [5.28 kW] 024 = 24,000 BTU/HR [7.03 kW] 030 = 30,000 BTU/HR [8.79 kW] 036 = 36,000 BTU/HR [10.55 kW] 042 = 42,000 BTU/HR [12.31 kW] 048 = 48,000 BTU/HR [14.07 kW] 056 = 56,000 BTU/HR [16.41 kW] 060 = 60,000 BTU/HR [17.58 kW]
J A Z
RHEEM REMOTE
HEAT PUMP
Q = 15 SEER DESIGN
SERIES
L = R-410A
ELECTRICAL
DESIGNATION
J = 208/230V-1-60
VARIATIONS
A SERIES = FULL-FEATURED
COOLING
CONNECTION
FITTING
Z = SWEAT W/SCROLL
Model Number Identification
[ ] Designates Metric Conversions
Rheem Heating, Cooling and Water Heating 3
Accessories
Low Ambient Control—Allows low temperature operation in the cooling cycle down to 0°F [-17.8°C] outdoor temperature. It is recommended that this control be installed in units to be operated for cooling at outdoor ambient temperatures under 70°F [21°C]. (Model No. RXAD-A08)
Outdoor Thermostats— RXPT-A01—One outdoor thermostat in box. RXPT-A02—One outdoor thermostat for mounting in box for use with RXPT-A01 or A03. RXPT-A03—One outdoor thermostat with emergency Heat Relay wired and mounted in box. RXPT-A04—Two outdoor thermostats with emergency Heat Relay wired and mounted in box.
Compressor Crankcase Heater—Available through PROSTOCK®.
Heat Pump Monitor—Indicates inefficient operation or malfunction of heat pump. (Model No. RXPM-B01)
Thermostats—
Blower Time Delay Control (RXMD-C04 is not required if the outdoor unit is matched with a Rheem furnace or air handler or if the furnace or air handler used has a blower off time delay built in.)
Fossil Fuel Kits—RXPF-01
RXPF-02
Hard Start Components—Offer additional starting torque to cover a wide range of voltage and pressure variations. Available through PROSTOCK
®
Heat Pump Thermostat Warning Light Kit—This component senses a compressor lock out and tells the thermostat service light to come on. This will let the homeowner know that service is needed on the system. (Model No. RXPX-D01)
[ ] Designates Metric Conversions
SCROLL COMPRESSOR
The scroll compressor is the key to efficiency for this Rheem model. Itʼs the latest in high-efficiency compressor technology. The advanced scroll compressor offers low noise and vibration characteristics and features tolerance to liquid refrigerant and system contamination. The scroll compressor also has low start torque, eliminating start problems in the field. And its unique design enables the RPQL- heat pumps to perform efficiently, quietly and dependably.
For all season home comfort, performance and energy conservation, choose a Rheem Series Heat Pump and a RHSL, RHLL, or RHKL Series Air Handler.
More than a reverse cycle air conditioner, itʼs a specially designed combination Winter/Summer comfort system using a single indoor coil for heating and cooling.
To choose an Air Handler designed for use with the RPQL- Heat Pumps, refer to the Performance Data Tables and/or the air handler specification sheet.
Rheem Heat Pump System
4 Rheem Heating, Cooling and Water Heating
Model Numbers
AHRI Cooling Performance AHRI Heating Performance (70°F [21°C] Indoor)
80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Outdoor Air
47°F [8.5°C] DB/
43°F [6°C] WB
DOE High Temp.
Outdoor Air 17°F [–8.5°C] DB/ 15°F [–9.5°C] WB
DOE Low Temp.
DOE
Region
IV
HSPF
Outdoor
Unit
RPQL-
Indoor
Coil and/or
Air Handler
Tot al
Capacity
BTU/H
[kW]
Net Sens. BTU/H
[kW]
Net Latent BTU/H
[kW]
EER SEER
Snd. Rate
dB
Indoor
CFM
[L/s]
BTU/H
[kW]
COP
BTU/H
[kW]
COP
018JAZ
RHLL-HM2417 (RCSL-H*2417)
18,700
[5.5]
14,350
[4.2]
4,350
[1.3]
13.00 15.50 72
625
[295]
17,200
[5.0]
4.02
10,400
[3.0]
2.60 9.50
RCFL-H*2414
18,300
[5.4]
13,950
[4.1]
4,350
[1.3]
11.50 14.00 72
650
[307]
17,800
[5.2]
3.68
10,900
[3.2]
2.38 8.50
RCFL-H*2417
18,300
[5.4]
13,950
[4.1]
4,350
[1.3]
11.50 14.00 72
650
[307]
17,800
[5.2]
3.68
10,900
[3.2]
2.38 8.50
RCFL-H*2417 (RGFD-06?MCK?)
18,400
[5.4]
13,950
[4.1]
4,450
[1.3]
12.00 15.50 72
600
[283]
17,200
[5.0]
4.00
10,400
[3.0]
2.56 9.50
RCFL-H*2417 (RGFD-07?MCK?)
18,400
[5.4]
13,950
[4.1]
4,450
[1.3]
12.00 15.50 72
600
[283]
17,200
[5.0]
4.00
10,400
[3.0]
2.56 9.50
RCFL-H*2417 (RGFE-06?MCK?)
18,300
[5.4]
13,800
[4.0]
4,500
[1.3]
12.50 15.50 72
575
[271]
17,200
[5.0]
4.02
10,400
[3.0]
2.58 9.50
RCFL-H*2417 (RGFE-07?MCK?)
18,500
[5.4]
14,050
[4.1]
4,450
[1.3]
13.00 15.50 72
600
[283]
17,200
[5.0]
4.02
10,400
[3.0]
2.58 9.50
RCFL-H*2417 (RGGD-06?MCK?)
18,500
[5.4]
14,050
[4.1]
4,450
[1.3]
13.00 15.50 72
600
[283]
17,200
[5.0]
4.04
10,400
[3.0]
2.58 9.50
RCFL-H*2417 (RGGD-07?MCK?)
18,700
[5.5]
14,350
[4.2]
4,350
[1.3]
13.00 15.50 72
625
[295]
17,200
[5.0]
4.02
10,400
[3.0]
2.58 9.50
RCFL-H*2417 (RGGE-06?MCK?)
18,700
[5.5]
14,350
[4.2]
4,350
[1.3]
13.00 15.50 72
625
[295]
17,200
[5.0]
4.04
10,400
[3.0]
2.58 9.50
RCFL-H*2417 (RGGE-07?MCK?)
18,300
[5.4]
13,800
[4.0]
4,500
[1.3]
13.00 15.50 72
575
[271]
17,200
[5.0]
4.04
10,400
[3.0]
2.58 9.50
RCFL-H*2417 (RGJD-06?MCK?)
18,500
[5.4]
14,050
[4.1]
4,450
[1.3]
13.00 15.50 72
600
[283]
17,200
[5.0]
4.04
10,400
[3.0]
2.58 9.50
RCFL-H*2417 (RGJD-07?MCK?)
18,700
[5.5]
14,350
[4.2]
4,350
[1.3]
13.00 15.50 72
625
[295]
17,200
[5.0]
4.02
10,400
[3.0]
2.58 9.50
RCFL-H*2417 (RGJF-06?MCK?)
18,700
[5.5]
14,350
[4.2]
4,350
[1.3]
13.00 15.50 72
625
[295]
17,200
[5.0]
4.04
10,400
[3.0]
2.58 9.50
RCFL-H*2417 (RGJF-07?MCK?)
18,300
[5.4]
13,800
[4.0]
4,500
[1.3]
13.00 15.50 72
575
[271]
17,200
[5.0]
4.04
10,400
[3.0]
2.60 9.50
RCFL-H*2417 (RGLE-07?AMK?)
18,500
[5.4]
14,050
[4.1]
4,450
[1.3]
13.00 15.50 72
600
[283]
17,200
[5.0]
4.06
10,400
[3.0]
2.60 9.50
RCFL-H*2417 (RGLR-07?AMK?)
18,500
[5.4]
14,050
[4.1]
4,450
[1.3]
13.00 15.50 72
600
[283]
17,200
[5.0]
4.04
10,400
[3.0]
2.58 9.50
RCFL-H*2417 (RGLT-07?AME?)
18,700
[5.5]
14,350
[4.2]
4,350
[1.3]
13.00 15.50 72
675
[319]
17,200
[5.0]
4.02
10,400
[3.0]
2.58 9.50
RCFL-H*2417 (RGPE-05?BMK?)
18,300
[5.4]
13,800
[4.0]
4,500
[1.3]
12.50 15.50 72
575
[271]
17,200
[5.0]
4.04
10,400
[3.0]
2.58 9.50
RCFL-H*2417 (RGPE-07?AMK?)
18,700
[5.5]
14,350
[4.2]
4,350
[1.3]
13.00 15.50 72
625
[295]
17,200
[5.0]
4.04
10,400
[3.0]
2.60 9.50
RCFL-H*2417 (RGPR-05?BMK?)
18,400
[5.4]
13,950
[4.1]
4,450
[1.3]
12.00 15.50 72
600
[283]
17,300
[5.1]
3.98
10,500
[3.1]
2.56 9.50
RCFL-H*2417 (RGPR-07?AMK?)
18,500
[5.4]
14,050
[4.1]
4,450
[1.3]
13.00 15.50 72
600
[283]
17,200
[5.0]
4.02
10,400
[3.0]
2.58 9.50
RCFL-H*2417 (RGPT-05?BMK?)
18,700
[5.5]
14,350
[4.2]
4,350
[1.3]
13.00 15.50 72
650
[307]
17,200
[5.0]
4.00
10,400
[3.0]
2.56 9.50
RCFL-H*2417 (RGPT-07?AME?)
18,700
[5.5]
14,350
[4.2]
4,350
[1.3]
13.00 15.50 72
625
[295]
17,200
[5.0]
4.02
10,400
[3.0]
2.58 9.50
RCFL-H*2417 (RGRM-04?MAE?)
18,300
[5.4]
13,800
[4.0]
4,500
[1.3]
12.50 15.00 72
575
[271]
17,200
[5.0]
4.00
10,400
[3.0]
2.56 9.50
RCFL-H*2417 (RGRM-06?MAE?)
18,400
[5.4]
13,950
[4.1]
4,450
[1.3]
12.50 15.50 72
600
[283]
17,200
[5.0]
4.02
10,400
[3.0]
2.58 9.50
RCFL-H*2417 (RGRM-07?MAE?)
18,600
[5.4]
14,250
[4.2]
4,350
[1.3]
12.50 15.00 72
625
[295]
17,300
[5.1]
3.96
10,500
[3.1]
2.54 9.50
RCFL-H*2417 (RGTM-06?MAE?)
18,700
[5.5]
14,350
[4.2]
4,350
[1.3]
13.00 15.50 72
625
[295]
17,200
[5.0]
4.00
10,400
[3.0]
2.58 9.50
ROCA-070E03 (RCFL-H*2417)
18,500
[5.4]
14,050
[4.1]
4,450
[1.3]
13.00 15.50 72
600
[283]
17,200
[5.0]
4.06
10,400
[3.0]
2.60 9.50
Rev.
6/30/10
Performance Data AHRI Standard Conditions—RPQL-
Note: Only these combinations of indoor/outdoor units are approved and any other combinations should not be used.
Highest sales volume tested combination required by DOE test procedures. [ ] Designates Metric Conversions
Rheem Heating, Cooling and Water Heating 5
Model Numbers
AHRI Cooling Performance AHRI Heating Performance (70°F [21°C] Indoor)
80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Outdoor Air
47°F [8.5°C] DB/
43°F [6°C] WB
DOE High Temp.
Outdoor Air 17°F [–8.5°C] DB/ 15°F [–9.5°C] WB
DOE Low Temp.
DOE
Region
IV
HSPF
Outdoor
Unit
RPQL-
Indoor Coil and/or Air Handler
Tot al
Capacity
BTU/H
[kW]
Net
Sens.
BTU/H
[kW]
Net Latent BTU/H
[kW]
EER SEER
Snd. Rate
dB
Indoor
CFM [L/s]
BTU/H
[kW]
COP
BTU/H
[kW]
COP
018JAZ
ROLA-070E03 (RCFL-H*2417)
18,400
[5.4]
13,950
[4.1]
4,450
[1.3]
12.50 15.00 72
600
[283]
17,200
[5.0]
4.00
10,400
[3.0]
2.58 9.50
RHKL-HM2417 (RCSL-H*2417)
18,700
[5.5]
14,350
[4.2]
4,350
[1.3]
13.00 15.50 72
625
[295]
17,200
[5.0]
4.02
10,400
[3.0]
2.58 9.50
RHSL-HM1817 (RCSL-H*2417)
18,100
[5.3]
13,750
[4.0]
4,350
[1.3]
12.00 14.00 72
600
[283]
17,600
[5.2]
3.78
10,800
[3.2]
2.44 9.00
024JAZ
RHLL-HM2417 (RCSL-H*2417)
24,000
[7.0]
17,950
[5.3]
6,050
[1.8]
13.00 15.00 72
800
[378]
23,000
[6.7]
3.72
13,900
[4.1]
2.44 9.00
RCFL-H*2414
23,600
[6.9]
17,550
[5.1]
6,050
[1.8]
11.50 14.00 72
800
[378]
23,600
[6.9]
3.48
14,500
[4.2]
2.30 8.50
RCFL-H*2417
23,600
[6.9]
17,550
[5.1]
6,050
[1.8]
11.50 14.00 72
800
[378]
23,600
[6.9]
3.48
14,500
[4.2]
2.30 8.60
RCFL-H*2417 (RGFD-06?MCK?)
23,800
[7.0]
17,800
[5.2]
6,000
[1.8]
12.00 14.50 72
800
[378]
23,200
[6.8]
2.62
14,100
[4.1]
2.40 8.50
RCFL-H*2417 (RGFD-07?MCK?)
24,000
[7.0]
17,950
[5.3]
6,050
[1.8]
12.00 14.50 72
800
[378]
23,200
[6.8]
3.64
14,000
[4.1]
2.40 8.50
RCFL-H*2417 (RGFE-06?MCK?)
24,000
[7.0]
17,950
[5.3]
6,050
[1.8]
12.50 15.00 72
800
[378]
23,000
[6.7]
3.66
14,000
[4.1]
2.42 8.50
RCFL-H*2417 (RGFE-07?MCK?)
23,600
[6.9]
17,350
[5.1]
6,250
[1.8]
12.50 15.00 72
725
[342]
23,000
[6.7]
3.70
13,900
[4.1]
2.44 8.50
RCFL-H*2417 (RGGD-06?MCK?)
24,000
[7.0]
17,950
[5.3]
6,050
[1.8]
13.00 15.00 72
800
[378]
23,000
[6.7]
3.68
13,900
[4.1]
2.42 9.00
RCFL-H*2417 (RGGD-07?MCK?)
24,000
[7.0]
17,950
[5.3]
6,050
[1.8]
12.00 15.00 72
800
[378]
23,000
[6.7]
3.66
14,000
[4.1]
2.42 9.00
RCFL-H*2417 (RGGE-06?MCK?)
24,000
[7.0]
17,950
[5.3]
6,050
[1.8]
12.50 15.00 72
825
[389]
23,000
[6.7]
3.68
13,900
[4.1]
2.44 9.00
RCFL-H*2417 (RGGE-07?MCK?)
24,000
[7.0]
17,950
[5.3]
6,050
[1.8]
12.50 15.00 72
800
[378]
23,000
[6.7]
3.68
13,900
[4.1]
2.42 9.00
RCFL-H*2417 (RGJD-06?MCK?)
24,000
[7.0]
17,950
[5.3]
6,050
[1.8]
13.00 15.00 72
800
[378]
23,000
[6.7]
3.68
13,900
[4.1]
2.42 9.00
RCFL-H*2417 (RGJD-07?MCK?)
24,000
[7.0]
17,950
[5.3]
6,050
[1.8]
12.00 15.00 72
800
[378]
23,000
[6.7]
3.66
14,000
[4.1]
2.42 9.00
RCFL-H*2417 (RGJF-06?MCK?)
24,000
[7.0]
17,950
[5.3]
6,050
[1.8]
12.50 15.00 72
825
[389]
23,000
[6.7]
3.68
13,900
[4.1]
2.44 9.00
RCFL-H*2417 (RGJF-07?MCK?)
24,000
[7.0]
17,950
[5.3]
6,050
[1.8]
12.50 15.00 72
800
[378]
23,000
[6.7]
3.68
13,900
[4.1]
2.44 9.00
RCFL-H*2417 (RGLE-07?AMK?)
24,000
[7.0]
17,950
[5.3]
6,050
[1.8]
12.50 15.00 72
800
[378]
23,000
[6.7]
3.72
13,900
[4.1]
2.44 9.00
RCFL-H*2417 (RGLR-07?AMK?)
24,000
[7.0]
17,950
[5.3]
6,050
[1.8]
13.00 15.50 72
800
[378]
23,000
[6.7]
2.70
13,900
[4.1]
2.44 9.00
RCFL-H*2417 (RGLT-07?AME?)
24,200
[7.1]
18,300
[5.4]
5,900
[1.7]
12.50 15.00 72
850
[401]
23,000
[6.7]
3.68
14,000
[4.1]
2.42 9.00
RCFL-H*2417 (RGPE-05?BMK?)
24,000
[7.0]
17,950
[5.3]
6,050
[1.8]
12.50 15.00 72
800
[378]
23,000
[6.7]
3.68
13,900
[4.1]
2.44 9.00
RCFL-H*2417 (RGPE-07?AMK?)
24,000
[7.0]
17,950
[5.3]
6,050
[1.8]
12.50 15.00 72
825
[389]
23,000
[6.7]
3.70
13,900
[4.1]
2.44 9.00
RCFL-H*2417 (RGPR-05?BMK?)
24,000
[7.0]
17,950
[5.3]
6,050
[1.8]
12.00 15.00 72
775
[366]
23,200
[6.8]
2.64
14,000
[4.1]
2.40 8.50
RCFL-H*2417 (RGPR-07?AMK?)
24,000
[7.0]
17,950
[5.3]
6,050
[1.8]
13.00 15.00 72
800
[378]
23,000
[6.7]
2.68
13,900
[4.1]
2.44 9.00
RCFL-H*2417 (RGPT-05?BMK?)
24,200
[7.1]
18,300
[5.4]
5,900
[1.7]
12.50 14.50 72
850
[401]
23,200
[6.8]
3.64
14,000
[4.1]
2.40 8.50
RCFL-H*2417 (RGPT-07?AME?)
24,200
[7.1]
18,300
[5.4]
5,900
[1.7]
12.50 15.00 72
850
[401]
23,000
[6.7]
3.66
14,000
[4.1]
2.42 9.00
RCFL-H*2417 (RGRM-04?MAE?)
24,000
[7.0]
17,950
[5.3]
6,050
[1.8]
12.00 14.50 72
800
[378]
23,200
[6.8]
3.64
14,000
[4.1]
2.40 8.50
RCFL-H*2417 (RGRM-06?MAE?)
24,000
[7.0]
17,950
[5.3]
6,050
[1.8]
12.00 14.50 72
825
[389]
23,200
[6.8]
3.64
14,000
[4.1]
2.40 8.50
Rev.
6/30/10
Performance Data AHRI Standard Conditions—RPQL- (cont.)
Note: Only these combinations of indoor/outdoor units are approved and any other combinations should not be used.
Highest sales volume tested combination required by DOE test procedures. [ ] Designates Metric Conversions
6 Rheem Heating, Cooling and Water Heating
Model Numbers
AHRI Cooling Performance AHRI Heating Performance (70°F [21°C] Indoor)
80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Outdoor Air
47°F [8.5°C] DB/
43°F [6°C] WB
DOE High Temp.
Outdoor Air 17°F [–8.5°C] DB/ 15°F [–9.5°C] WB
DOE Low Temp.
DOE
Region
IV
HSPF
Outdoor
Unit
RPQL-
Indoor Coil and/or Air Handler
Tot al
Capacity
BTU/H
[kW]
Net
Sens.
BTU/H
[kW]
Net Latent BTU/H
[kW]
EER SEER
Snd. Rate
dB
Indoor
CFM [L/s]
BTU/H
[kW]
COP
BTU/H
[kW]
COP
024JAZ
RCFL-H*2417 (RGRM-07?MAE?)
24,000
[7.0]
18,150
[5.3]
5,850
[1.7]
12.00 14.00 72
850
[401]
23,200
[6.8]
3.58
14,200
[4.2]
2.36 8.50
RCFL-H*2417 (RGTM-06?MAE?)
23,800
[7.0]
17,600
[5.2]
6,200
[1.8]
12.50 15.00 72
750
[354]
23,000
[6.7]
3.74
13,800
[4.0]
2.46 9.00
ROCA-070E03 (RCFL-H*2417)
24,000
[7.0]
17,950
[5.3]
6,050
[1.8]
12.50 15.00 72
800
[378]
23,000
[6.7]
3.70
13,900
[4.1]
2.44 9.00
ROCA-070E04 (RCFL-H*2417)
24,000
[7.0]
17,950
[5.3]
6,050
[1.8]
12.50 15.00 72
800
[378]
23,000
[6.7]
3.70
13,900
[4.1]
2.44 9.00
ROLA-070E03 (RCFL-H*2417)
24,000
[7.0]
17,950
[5.3]
6,050
[1.8]
12.50 15.00 72
800
[378]
23,000
[6.7]
3.70
13,900
[4.1]
2.44 9.00
ROLA-070E04 (RCFL-H*2417)
24,000
[7.0]
17,950
[5.3]
6,050
[1.8]
12.50 15.00 72
800
[378]
23,000
[6.7]
3.70
13,900
[4.1]
2.44 9.00
RHKL-HM2417 (RCSL-H*2417)
24,200
[7.1]
18,300
[5.4]
5,900
[1.7]
13.00 15.00 72
850
[401]
23,000
[6.7]
3.68
13,900
[4.1]
2.42 9.00
RHSL-HM2417 (RCSL-H*2417)
23,800
[7.0]
17,800
[5.2]
6,000
[1.8]
12.00 14.00 72
800
[378]
23,400
[6.9]
2.52
14,300
[4.2]
2.34 8.50
030JAZ
RHLL-HM3617 (RCSL-H*3617)
30,000
[8.8]
21,900
[6.4]
8,100
[2.4]
13.00 15.50 73
1,000 [472]
29,000
[8.5]
3.82
18,300
[5.4]
2.60 9.00
RCFL-H*3617
29,600
[8.7]
21,500
[6.3]
8,100
[2.4]
11.50 14.00 73
1,000 [472]
29,600
[8.7]
3.60
18,900
[5.5]
2.44 8.50
RCFL-H*3617 (RGFD-06?MCK?)
29,600
[8.7]
21,600
[6.3]
8,000
[2.3]
12.00 14.00 73
1,000 [472]
29,400
[8.6]
3.66
18,700
[5.5]
2.48 9.00
RCFL-H*3617 (RGFD-07?MCK?)
29,600
[8.7]
21,600
[6.3]
8,000
[2.3]
12.00 14.50 73
1,000 [472]
29,200
[8.6]
3.70
18,600
[5.4]
2.50 9.00
RCFL-H*3617 (RGFE-06?MCK?)
29,600
[8.7]
21,550
[6.3]
8,050
[2.4]
12.00 14.50 73
1,000 [472]
29,200
[8.6]
3.72
18,500
[5.4]
2.50 9.00
RCFL-H*3617 (RGFE-07?MCK?)
29,600
[8.7]
21,550
[6.3]
8,050
[2.4]
12.00 14.50 73
1,025 [484]
29,400
[8.6]
3.70
18,500
[5.4]
2.48 9.00
RCFL-H*3617 (RGGD-06?MCK?)
29,800
[8.7]
21,800
[6.4]
8,000
[2.3]
12.00 14.50 73
1,000 [472]
29,200
[8.6]
3.72
18,600
[5.4]
2.52 9.00
RCFL-H*3617 (RGGD-07?MCK?)
29,600
[8.7]
21,600
[6.3]
8,000
[2.3]
12.00 14.50 73
1,025 [484]
29,400
[8.6]
3.70
18,600
[5.4]
2.50 9.00
RCFL-H*3617 (RGGE-06?MCK?)
29,800
[8.7]
21,700
[6.4]
8,100
[2.4]
12.00 14.50 73
1,025 [484]
29,200
[8.6]
3.74
18,400
[5.4]
2.52 9.00
RCFL-H*3617 (RGGE-07?MCK?)
29,800
[8.7]
21,700
[6.4]
8,100
[2.4]
12.00 14.50 73
1,025 [484]
29,200
[8.6]
3.72
18,500
[5.4]
2.50 9.00
RCFL-H*3617 (RGJD-06?MCK?)
29,800
[8.7]
21,800
[6.4]
8,000
[2.3]
12.00 14.50 73
1,000 [472]
29,200
[8.6]
3.72
18,600
[5.4]
2.52 9.00
RCFL-H*3617 (RGJD-07?MCK?)
29,600
[8.7]
21,600
[6.3]
8,000
[2.3]
12.00 14.50 73
1,025 [484]
29,400
[8.6]
3.70
18,600
[5.4]
2.50 9.00
RCFL-H*3617 (RGJF-06?MCK?)
29,800
[8.7]
21,700
[6.4]
8,100
[2.4]
12.00 14.50 73
1,025 [484]
29,200
[8.6]
3.74
18,400
[5.4]
2.52 9.00
RCFL-H*3617 (RGJF-07?MCK?)
29,800
[8.7]
21,700
[6.4]
8,100
[2.4]
12.00 14.50 73
1,025 [484]
29,200
[8.6]
3.74
18,500
[5.4]
2.50 9.00
RCFL-H*3617 (RGLE-07?AMK?)
29,800
[8.7]
21,700
[6.4]
8,100
[2.4]
12.50 15.00 73
1,025 [484]
29,200
[8.6]
3.78
18,300
[5.4]
2.54 9.00
RCFL-H*3617 (RGLR-07?AMK?)
29,800
[8.7]
21,750
[6.4]
8,050
[2.4]
11.50 15.00 73
1,025 [484]
29,200
[8.6]
3.76
18,500
[5.4]
2.54 9.00
RCFL-H*3617 (RGLT-07?AME?)
30,000
[8.8]
22,100
[6.5]
7,900
[2.3]
12.50 15.00 73
1,050 [495]
29,200
[8.6]
3.74
18,400
[5.4]
2.52 9.00
RCFL-H*3617 (RGPE-05?BMK?)
29,800
[8.7]
21,700
[6.4]
8,100
[2.4]
12.50 15.00 73
975
[460]
29,200
[8.6]
3.76
18,400
[5.4]
2.52 9.00
RCFL-H*3617 (RGPE-07?AMK?)
29,800
[8.7]
21,700
[6.4]
8,100
[2.4]
12.50 15.00 73
1,000 [472]
29,200
[8.6]
3.76
18,300
[5.4]
2.52 9.00
RCFL-H*3617 (RGPR-05?BMK?)
29,600
[8.7]
21,600
[6.3]
8,000
[2.3]
12.00 14.50 73
1,000 [472]
29,400
[8.6]
3.70
18,600
[5.4]
2.50 9.00
RCFL-H*3617 (RGPR-07?AMK?)
29,800
[8.7]
21,750
[6.4]
8,050
[2.4]
12.00 14.50 73
1,000 [472]
29,200
[8.6]
3.76
18,500
[5.4]
2.54 9.00
Rev.
6/30/10
Performance Data AHRI Standard Conditions—RPQL- (cont.)
Note: Only these combinations of indoor/outdoor units are approved and any other combinations should not be used.
Highest sales volume tested combination required by DOE test procedures. [ ] Designates Metric Conversions