Rudd RPNL-024JEZ Installation Manual

FORM NO. P11-772 REV. 5
Supersedes Form No. P11-772 Rev. 4
The Rheem Prestige Series™ RPNL- JEZ Heat Pump Outdoor units can provide year-round heating and cooling comfort for resi­dential, multi-family and light commercial applications. They are designed to operate with Rheem indoor units with cooling and heating capacities certified under the AHRI Certification program. The following additional features, plus its energy-saving character­istics, make the RPNL- JEZ Heat Pump outdoor unit an excellent choice for new construction or upgrading your present system. The Rheem Prestige Series™ RPNL- JEZ Heat Pumps are the result of an ongoing development program for improved efficiencies.
The Comfort Control System™ provides on-board diagnostics and fault history for heat pumps with single-phase compressors by detecting system and electrical problems without adding sen­sors. It can also communicate “fault codes” to enabled “L terminal” thermostats. The integrated diagnostics with Active Protection prevents compressor operation when potentially harmful condi­tions are detected.
7-Segment LED Display is exclusive only to Rheem products. The information-display quickly and accurately shows technicians the source of malfunctions.
Features a five-year conditional unit replacement warranty when properly installed with a new Rheem Air Handler OR Rheem Indoor Coil with a Rheem Gas Furnace.
Compressor sound blanket is standard to provide quiet operation.
Attractive, louvered wrap around jacket protects coil from weather extremes and yard hazards. Top grille is steel reinforced for extra strength. Cabinet is powder painted for all weather protection.
Four sided outdoor coil design allows compressor operation with access panel removed.
Air is discharged upward away from bushes and shrubs. The dis­charge pattern of the top grille provides minimum air restriction, resulting in quiet fan operation.
Combination Grille/Motor Mount secures the fan motor to the underside of the discharge grille.
Removable top grille provides access to the outdoor fan motor and outdoor coil.
Compressor compartment offers additional protection from the elements and reduces operating noise.
Single speed, 8-pole fan motor is designed for quieter, energy­saving operation.
Non-cycling reversing valve and demand defrost.
All models meet or exceed a 1000-hour salt spray test per ASTM B117 Standard Practice for Operating Salt Spray Testing Apparatus.
HEAT PUMPS
Equipped with the Award Winning
Comfort Control System
• Increased Reliability
• On-Board Diagnostics
• Fault Recall
Active Protection
RPNL- JEZ
13 SEER Models Nominal Sizes 2 to 5 Tons [7.03 kW] to [17.6 kW]
Six Models
Cooling Capacities 23,200 to 60,500 BTU/HR [6.80 kW] to [17.73 kW]
“Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps must be matched with
appropriate coil components to meet ENERGY STAR criteria. Ask your Contractor for details or visit www.energystar.gov.”
(IN CERTAIN MATCHED SYSTEMS)
13.0
2 Rheem Heating, Cooling and Water Heating
The Rheem exclusive 7-Segment LED Display easily shows system
operating status codes and diagnostic codes.
A Sealed Switch replaces the standard
contactor and fea­tures optical control and latching mecha­nism. The sealed
switch prevents infil­tration of insects and dust. A minimal switching arc, by the optical control, offers greater reliability. The latching mechanism con­sumes less power while reducing chatter.
The Status Indication and System Diagnostics feature thermostat
communication capability, built-in diagnostics, high & low voltage monitoring and high & low pressure switch monitoring. The thermo-
stat communication capability alerts the homeowner to any necessary service requirements. Faster, more accurate service is provided by the built-in diagnos­tics, by providing the HVAC professional with dependable information. With the high and low voltage monitoring feature, the con­trol provides alerts for out-of-range condi­tions. In addition, high and low pressure­switch monitoring prevents the system from operating outside of its normal parameters.
The fault recall feature will allow for the last six fault-codes to be displayed, and will retain these codes even if power failure occurs.
Built-in short-cycle protection allows the compressor to restart eas­ily without oil removal.
A 30-second minimum run-time for every compressor call enables oil to return to the compressor.
Active Protection monitors the system to prevent nuisance lockouts and prevents compressor operation when potentially harmful conditions are detected.
The compressor and fan are controlled independently, which reduces the starting load and light dimming.
A manual push-button is offered to operate the compressor and fan for 5 seconds to allow for an operation check.
In order to save time and money, replacement automotive fuses can be utilized instead of replacing the entire control board.
STANDARD FEATURES
RPNL- JEZ Heat Pump Outdoor Units
1. Scroll compressor is hermetically sealed and incorporates internal high temperature motor overload protection, and durable insulation on the motor windings. It is externally mounted on rubber grommets to reduce vibration and noise.
2. Enhanced Compressor Protection—Features an enhanced defrost control, auto-reset high pressure control, and auto-reset low pressure control to provide compressor protection under
abnormally high head pressure conditions (outdoor fan failure, restriction, dirty coil, etc.) or abnormally low suction pressure condi­tions (restrictions, TEV failure, loss of charge, indoor blower failure, etc.) while eliminating nuisance tripping sometimes experienced with conventional control systems.
3. Compressors have an internal pressure relief assembly to protect against excessive pressure differential.
4. All refrigerant connections are on the exterior of the unit, located close to the ground for neat appearing installations.
5. Cabinet is constructed of powder painted galvanized steel. The full wrap-around louvered grille protects the coil from damage.
6. Enhanced compressor sound blanket is standard.
7. Demand Defrost Control—Provides complete defrost when defrost
is required.
8. Non-Cycling Reversing Valve—Eliminates discharge noises on each heating cycle.
9. Hot Gas Muffler—Reduces noise in heating cycle.
10. Bi-Directional Filter Drier—Standard on RPNL- JEZ models
(shipped – not installed).
11. Service valves are standard on all models.
12. Refrigerant Metering—TEV accurately meters refrigerant into
indoor and outdoor coils.
13. Copper tube—aluminum fin coils are used on all models.
14. The control box is located in the top corner of the cabinet providing
for easy access through a service panel.
15. Service valves are standard on all models.
16. Field connections for power and control wiring are kept separate.
17. Every unit is factory charged and run-tested.
18. Separate compressor compartment for easy service access.
19. Drawn, painted basepan for extra corrosion resistance and sound
reduction.
20. The RPNL- JEZ has a 10 year limited compressor warranty, plus a 5 year conditional unit replacement warranty. See General Terms of Limited Warranty for more details.
21. Hard Start Kits—Standard on all JEZ models.
22. Control Box Cover.
FEATURES & BENEFITS OF THE COMFORT CONTROL SYSTEM
SCROLL® COMPRESSOR
The scroll compressor is the key to efficiency for this Rheem model. It’s the latest in high-efficiency compressor technology. The advanced scroll compressor offers low noise and vibration characteristics and features tolerance to liquid refrigerant and system contamination. The scroll compressor also has low start torque, eliminating start problems in the field. And its unique design enables the RPNL- JEZ Heat Pump to perform efficiently, quietly and dependably.
Rheem Heating, Cooling and Water Heating 3
Field Installed Accessories
Low Ambient Control—Allows low temperature operation in the cooling cycle down to 0°F [-17.8°C] outdoor temperature. It is recommended that this control be installed in units to be operated for cooling at outdoor ambient temperatures under 70°F [21°C]. (Model No. RXAD-A08)
Thermostats
Compressor Crankcase Heater—Available through PROSTOCK®.
Thermostats and Subbases—Available through PROSTOCK®.
Blower Time Delay Control—RXMD-C04.
Fossil Fuel Kits—RXPF-01
RXPF-02
R P N L 024
COOLING
CAPACITY
024 = 24,000 BTU/HR [7.03 kW]
037/031 = 30,000 BTU/HR [8.79 kW]
036/037 = 36,000 BTU/HR [10.55 kW]
037/043 = 42,000 BTU/HR [12.31 kW] 037/049 = 48,000 BTU/HR [14.07 kW] 037/060 = 60,000 BTU/HR [17.58 kW]
J E Z
RHEEM REMOTE
HEAT PUMP
N = 13 SEER DESIGN
SERIES
L = R-410A
ELECTRICAL
DESIGNATION
J = 208/230V-1-60
VARIATIONS
E = EQUIPPED WITH
THE COMFORT
CONTROL SYSTEM
COOLING
CONNECTION
FITTING
Z = SWEAT W/SCROLL
Model Number Identification
[ ] Designates Metric Conversions
Rheem Heat Pump System
More than a reverse cycle air conditioner, it’s a specially designed combination Winter/Summer comfort system using a single indoor coil for heating and cooling.
For all season home comfort, performance and energy conservation, choose a Rheem RPNL- JEZ Heat Pump and a RHSL, RHLL, or RHKL Series Air Handler.
To choose an Air Handler designed for use with the RPNL- JEZ Heat Pump, refer to the Performance Data Tables and/or the air handler specification sheet.
4 Rheem Heating, Cooling and Water Heating
Performance Data AHRI Standard Conditions—RPNL- JEZ
Note: Only these combinations of indoor/outdoor units are approved and any other combinations should not be used.
Highest sales volume tested combination required by DOE test procedures. [ ] Designates Metric Conversions
AHRI Cooling Performance
80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Sens.
BTU/H
[kW]
17,350
[5.1]
17,150
[5.0]
17,400
[5.1]
17,450
[5.1]
17,500
[5.1]
17,500
[5.1]
17,500
[5.1]
17,450
[5.1]
17,500
[5.1]
17,500
[5.1]
17,500
[5.1]
17,450
[5.1]
16,800
[4.9]
17,500
[5.1]
17,500
[5.1]
17,550
[5.1]
17,500
[5.1]
17,500
[5.1]
17,500
[5.1]
17,250
[5.1]
17,500
[5.1]
17,500
[5.1]
17,500
[5.1]
17,400
[5.1]
17,450
[5.1]
17,300
[5.1]
17,100
[5.0]
17,500
[5.1]
Net Latent BTU/H
[kW]
6,050
[1.8]
6,050
[1.8]
6,000
[1.8]
6,150
[1.8]
6,100
[1.8]
6,100
[1.8]
6,100
[1.8]
6,150
[1.8]
6,100
[1.8]
6,100
[1.8]
6,100
[1.8]
6,150
[1.8]
6,400
[1.9]
6,100
[1.8]
6,100
[1.8]
6,050
[1.8]
6,100
[1.8]
6,100
[1.8]
6,100
[1.8]
5,950
[1.7]
6,100
[1.8]
6,100
[1.8]
6,100
[1.8]
6,000
[1.8]
6,150
[1.8]
6,100
[1.8]
6,300
[1.8]
6,100
[1.8]
EER
SEER
11.00 13.00 70
10.60
13.00 70
11.30 13.50 70
11.40 13.50 70
11.55
14.00
11.50 14.00 70
11.60 14.00 70
11.50 14.00 70
11.60 14.00 70
11.60 14.00 70
11.60 14.00 70
11.50 14.00 70
11.55 14.00 70
11.60 14.00 70
11.75 14.00 70
11.75 14.00 70
11.50 14.00 70
11.65 14.00 70
11.65 14.00 70
11.30 13.50 70
11.65 14.00 70
11.00 13.50 70
11.50 14.00 70
11.35 13.50 70
11.40 13.50 70
11.05 13.00 70
11.65
14.00 70
11.50 14.00 70
Snd. Rate
dB
70
Indoor
[389]
[389]
[378]
[378]
[378]
[389]
[378]
[378]
[389]
[378]
[378]
[378]
[342]
[378]
[378]
[378]
[401]
[378]
[389]
[366]
[378]
[401]
[401]
[378]
[389]
[401]
[354]
[378]
Outdoor
Unit
RPNL-
Rev.
6/30/10
024JEZ
Model Numbers
Indoor Coil and/or Air Handler
RHSL-HM2417 (RCSL-H*2417)
RCFL-H*2414+RXMD-C04
RCFL-H*2417 (RGFD-06?MCK?)
RCFL-H*2417 (RGFD-07?MCK?)
RCFL-H*2417 (RGFE-06?MCK?)
RCFL-H*2417 (RGFE-07?MCK?)
RCFL-H*2417 (RGGD-06?MCK?)
RCFL-H*2417 (RGGD-07?MCK?)
RCFL-H*2417 (RGGE-06?MCK?)
RCFL-H*2417 (RGGE-07?MCK?)
RCFL-H*2417 (RGJD-06?MCK?)
RCFL-H*2417 (RGJD-07?MCK?)
RCFL-H*2417 (RGJF-06?MCK?)
RCFL-H*2417 (RGJF-07?MCK?)
RCFL-H*2417 (RGLE-07?AMK?)
RCFL-H*2417 (RGLR-07?AMK?)
RCFL-H*2417 (RGLT-07?AME?)
RCFL-H*2417 (RGPE-05?BMK?)
RCFL-H*2417 (RGPE-07?AMK?)
RCFL-H*2417 (RGPR-05?BMK?)
RCFL-H*2417 (RGPR-07?AMK?)
RCFL-H*2417 (RGPT-05?BMK?)
RCFL-H*2417 (RGPT-07?AME?)
RCFL-H*2417 (RGRM-04?MAE?)
RCFL-H*2417 (RGRM-06?MAE?)
RCFL-H*2417 (RGRM-07?MAE?)
RCFL-H*2417 (RGTM-06?MAE?)
ROCA-070E03 (RCFL-H*2417)
Tot al
Capacity
BTU/H
[kW]
23,400
[6.9]
23,200
[6.8]
23,400
[6.9]
23,600
[6.9]
23,600
[6.9]
23,600
[6.9]
23,600
[6.9]
23,600
[6.9]
23,600
[6.9]
23,600
[6.9]
23,600
[6.9]
23,600
[6.9]
23,200
[6.8]
23,600
[6.9]
23,600
[6.9]
23,600
[6.9]
23,600
[6.9]
23,600
[6.9]
23,600
[6.9]
23,200
[6.8]
23,600
[6.9]
23,600
[6.9]
23,600
[6.9]
23,400
[6.9]
23,600
[6.9]
23,400
[6.9]
23,400
[6.9]
23,600
[6.9]
AHRI Heating Performance (70°F [21°C] Indoor)
CFM [L/s]
825
825
800
800
800
825
800
800
825
800
800
800
725
800
800
800
850
800
825
775
800
850
850
800
825
850
750
800
Outdoor Air
47°F [8.5°C] DB/
43°F [6°C] WB
DOE High Temp.
BTU/H
[kW]
22,800
[6.7]
23,000
[6.7]
22,000
[6.4]
22,000
[6.4]
22,400
[6.6]
22,400
[6.6]
22,000
[6.4]
22,000
[6.4]
22,400
[6.6]
22,400
[6.6]
22,000
[6.4]
22,000
[6.4]
22,400
[6.6]
22,400
[6.6]
22,400
[6.6]
22,000
[6.4]
22,400
[6.6]
22,400
[6.6]
22,400
[6.6]
22,600
[6.6]
22,600
[6.6]
22,600
[6.6]
22,600
[6.6]
22,600
[6.6]
22,600
[6.6]
22,600
[6.6]
22,400
[6.6]
22,400
[6.6]
COP
3.56
3.46
3.92
3.92
3.68
3.66
3.92
3.92
3.70
3.68
3.92
3.92
3.72
3.70
3.72
3.92
3.68
3.70
3.70
3.64
3.64
3.64
3.66
3.64
3.64
3.58
3.74
3.72
Outdoor Air 17°F [–8.5°C] DB/ 15°F [–9.5°C] WB
DOE Low Temp.
BTU/H
[kW]
14,100
[4.1]
14,300
[4.2]
13,300
[3.9]
13,300
[3.9]
13,800
[4.0]
13,800
[4.0]
13,300
[3.9]
13,300
[3.9]
13,700
[4.0]
13,800
[4.0]
13,300
[3.9]
13,300
[3.9]
13,700
[4.0]
13,800
[4.0]
13,700
[4.0]
13,300
[3.9]
13,800
[4.0]
13,700
[4.0]
13,700
[4.0]
13,800
[4.0]
13,800
[4.0]
13,900
[4.1]
13,800
[4.0]
13,900
[4.1]
13,800
[4.0]
14,000
[4.1]
13,600
[4.0]
13,700
[4.0]
DOE
Region
IV
HSPF
COP
2.34 8.50
2.30 8.15
2.56 9.20
2.56 9.20
2.42 9.00
2.42
9.00
2.56 9.20
2.56
9.20
2.44 9.00
2.42 9.00
2.56
9.20
2.56 9.20
2.46 9.00
2.44 9.00
2.44 9.00
2.56 9.20
2.42 8.50
2.44 9.00
2.44 9.00
2.40 8.45
2.40 8.45
2.40 8.50
2.42 8.50
2.40 8.50
2.40 8.50
2.38 8.50
2.46 9.00
2.44 9.00
Rheem Heating, Cooling and Water Heating 5
Performance Data AHRI Standard Conditions—RPNL- JEZ (Con’t.)
Note: Only these combinations of indoor/outdoor units are approved and any other combinations should not be used.
Highest sales volume tested combination required by DOE test procedures. [ ] Designates Metric Conversions
Model Numbers
Outdoor
Unit
RPNL-
Rev.
6/30/10
ROCA-070E04 (RCFL-H*2417)
Indoor Coil and/or Air Handler
ROLA-070E03 (RCFL-H*2417)
ROLA-070E04 (RCFL-H*2417)
024JEZ
RCFL-H*2417+RXMD-C04
RBHP-17 (RCHL-24A*)
RHKL-HM2417 (RCSL-H*2417)
RHLL-HM2417 (RCSL-H*2417)
030JEZ RCFL-H*3621 (RGPR-07?AMK?)
RHSL-HM3017 (RCSL-H*3617)
RCFL-H*3617
RCFL-H*3617 (RGFD-07?MCK?)
RCFL-H*3617 (RGFE-06?MCK?)
RCFL-H*3617 (RGFE-07?MCK?)
RCFL-H*3617 (RGGD-06?MCK?)
RCFL-H*3617 (RGGD-07?MCK?)
RCFL-H*3617 (RGGE-06?MCK?)
RCFL-H*3617 (RGGE-07?MCK?)
RCFL-H*3617 (RGJD-06?MCK?)
031JEZ
RCFL-H*3617 (RGJD-07?MCK?)
RCFL-H*3617 (RGJF-06?MCK?)
RCFL-H*3617 (RGJF-07?MCK?)
RCFL-H*3617 (RGLE-07?AMK?)
RCFL-H*3617 (RGLR-07?AMK?)
RCFL-H*3617 (RGLT-07?AME?)
RCFL-H*3617 (RGPE-05?BMK?)
RCFL-H*3617 (RGPE-07?AMK?)
RCFL-H*3617 (RGPR-05?BMK?)
RCFL-H*3617 (RGPR-07?AMK?)
Tot al
Capacity
BTU/H
[kW]
23,600
[6.9]
23,600
[6.9]
23,600
[6.9]
23,200
[6.8]
23,000
[6.7]
23,600
[6.9]
23,600
[6.9]
29,600
[8.7]
28,400
[8.3]
28,200
[8.3]
28,400
[8.3]
28,600
[8.4]
28,400
[8.3]
28,600
[8.4]
28,400
[8.3]
28,600
[8.4]
28,600
[8.4]
28,600
[8.4]
28,400
[8.3]
28,600
[8.4]
28,600
[8.4]
28,600
[8.4]
28,600
[8.4]
28,800
[8.4]
28,600
[8.4]
28,600
[8.4]
28,400
[8.3]
28,600
[8.4]
AHRI Cooling Performance
80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Sens.
BTU/H
[kW]
17,500
[5.1]
17,500
[5.1]
17,500
[5.1]
17,150
[5.0]
16,600
[4.9]
17,500
[5.1]
17,450
[5.1]
22,050
[6.5]
20,950
[6.1]
20,750
[6.1]
20,900
[6.1]
21,100
[6.2]
20,950
[6.1]
21,100
[6.2]
20,950
[6.1]
21,100
[6.2]
21,100
[6.2]
21,100
[6.2]
20,950
[6.1]
21,100
[6.2]
21,100
[6.2]
21,100
[6.2]
21,100
[6.2]
21,450
[6.3]
21,100
[6.2]
21,100
[6.2]
20,950
[6.1]
21,100
[6.2]
Net Latent BTU/H
[kW]
6,100
[1.8]
6,100
[1.8]
6,100
[1.8]
6,050
[1.8]
6,400
[1.9]
6,100
[1.8]
6,150
[1.8]
7,550
[2.2]
7,450
[2.2]
7,450
[2.2]
7,500
[2.2]
7,500
[2.2]
7,450
[2.2]
7,500
[2.2]
7,450
[2.2]
7,500
[2.2]
7,500
[2.2]
7,500
[2.2]
7,450
[2.2]
7,500
[2.2]
7,500
[2.2]
7,500
[2.2]
7,500
[2.2]
7,350
[2.2]
7,500
[2.2]
7,500
[2.2]
7,450
[2.2]
7,500
[2.2]
EER
SEER
11.50 14.00 70
11.50
14.00 70
11.50 14.00 70
10.60 13.00 70
11.30
13.50
11.60 14.00 70
12.00 14.00 70
12.25 14.00 71
11.00 13.00 73
10.50 13.00 73
11.00 13.50 73
11.45 13.50 73
11.35 13.50 73
11.00 13.50 73
11.00 13.50 73
11.55 13.50 73
11.50 13.50 73
11.00 13.50 73
11.00 13.50 73
11.55 13.50 73
11.50 13.50 73
11.75 14.00 73
11.50 14.00 73
11.50 14.00 73
11.65 13.50 73
11.70 14.00 73
11.00
13.50 73
11.50 13.50 73
Snd. Rate
dB
70
Indoor
[L/s]
[378]
[378]
[378]
[389]
[378]
[401]
[366]
1,000
[472]
1,000
[472]
1,000
[472]
1,000
[472]
1,000
[472]
1,025
[484]
1,000
[472]
1,025
[484]
1,025
[484]
1,025
[484]
1,000
[472]
1,025
[484]
1,025
[484]
1,025
[484]
1,025
[484]
1,025
[484]
1,050
[495]
[460]
1,000
[472]
1,000
[472]
1,000
[472]
AHRI Heating Performance (70°F [21°C] Indoor)
CFM
800
800
800
825
800
850
775
975
Outdoor Air
47°F [8.5°C] DB/
43°F [6°C] WB
DOE High Temp.
BTU/H
[kW]
22,400
[6.6]
22,400
[6.6]
22,400
[6.6]
23,000
[6.7]
23,200
[6.8]
22,000
[6.4]
22,400
[6.6]
31,000
[9.1]
26,800
[7.9]
27,000
[7.9]
26,600
[7.8]
26,600
[7.8]
26,800
[7.9]
26,600
[7.8]
26,600
[7.8]
26,600
[7.8]
26,600
[7.8]
26,600
[7.8]
26,600
[7.8]
26,600
[7.8]
26,600
[7.8]
26,400
[7.7]
26,600
[7.8]
26,600
[7.8]
26,600
[7.8]
26,600
[7.8]
26,800
[7.9]
26,600
[7.8]
COP
3.72
3.72
3.72
3.46
3.52
3.92
3.76
4.00
3.60
3.52
3.62
3.62
3.62
3.64
3.62
3.66
3.64
3.64
3.62
3.66
3.64
3.70
3.68
3.66
3.68
3.68
2.62
3.68
Outdoor Air
17°F [–8.5°C] DB/
15°F [–9.5°C] WB
DOE Low Temp.
BTU/H
[kW]
13,700
[4.0]
13,700
[4.0]
13,700
[4.0]
14,300
[4.2]
14,500
[4.2]
13,300
[3.9]
13,600
[4.0]
19,200
[5.6]
17,500
[5.1]
17,700
[5.2]
17,400
[5.1]
17,400
[5.1]
17,400
[5.1]
17,300
[5.1]
17,400
[5.1]
17,300
[5.1]
17,300
[5.1]
17,300
[5.1]
17,400
[5.1]
17,300
[5.1]
17,300
[5.1]
17,200
[5.0]
17,200
[5.0]
17,300
[5.1]
17,200
[5.0]
17,200
[5.0]
17,400
[5.1]
17,200
[5.0]
DOE
Region
IV
HSPF
COP
2.44 9.00
2.44 9.00
2.44 9.00
2.30 8.15
2.34 8.50
2.56
9.20
2.46 8.90
2.64
9.25
2.50 9.00
2.46 9.00
2.52
9.00
2.52 9.00
2.50 9.00
2.52 9.00
2.52 9.00
2.54 9.00
2.52 9.00
2.52 9.00
2.52 9.00
2.54 9.00
2.52 9.00
2.56 9.00
2.56 9.00
2.54 9.00
2.54 9.00
2.54 9.00
2.52 9.00
2.56 9.00
6 Rheem Heating, Cooling and Water Heating
Performance Data AHRI Standard Conditions—RPNL- JEZ (Con’t.)
Note: Only these combinations of indoor/outdoor units are approved and any other combinations should not be used.
Highest sales volume tested combination required by DOE test procedures. [ ] Designates Metric Conversions
AHRI Cooling Performance
80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Sens.
BTU/H
[kW]
21,500
[6.3]
21,500
[6.3]
20,950
[6.1]
20,950
[6.1]
20,800
[6.1]
20,400
[6.0]
20,950
[6.1]
21,100
[6.2]
21,100
[6.2]
20,500
[6.0]
21,100
[6.2]
20,750
[6.1]
21,100
[6.2]
21,100
[6.2]
20,950
[6.1]
21,250
[6.2]
21,250
[6.2]
21,100
[6.2]
21,100
[6.2]
21,100
[6.2]
21,100
[6.2]
21,250
[6.2]
21,250
[6.2]
21,100
[6.2]
21,100
[6.2]
21,100
[6.2]
21,100
[6.2]
21,250
[6.2]
Net Latent BTU/H
[kW]
7,300
[2.1]
7,300
[2.1]
7,450
[2.2]
7,450
[2.2]
7,400
[2.2]
7,600
[2.2]
7,450
[2.2]
7,500
[2.2]
7,500
[2.2]
7,900
[2.3]
7,500
[2.2]
7,450
[2.2]
7,500
[2.2]
7,500
[2.2]
7,450
[2.2]
7,550
[2.2]
7,550
[2.2]
7,500
[2.2]
7,500
[2.2]
7,500
[2.2]
7,500
[2.2]
7,550
[2.2]
7,550
[2.2]
7,500
[2.2]
7,500
[2.2]
7,500
[2.2]
7,500
[2.2]
7,550
[2.2]
EER
SEER
11.00 13.50 73
11.00
13.50 73
11.20 13.00 73
11.35 13.00 73
10.95
13.00
11.05 13.00 73
11.40 13.50 73
11.50 14.00 73
11.50 14.00 73
11.50 14.00 73
11.50 14.00 73
10.50 13.00 73
11.00 13.50 73
11.50 13.50 73
11.40 13.50 73
11.90 14.00 73
11.80 14.00 73
11.50 13.50 73
11.00 13.50 73
11.60 13.50 73
11.55 13.50 73
11.90 14.00 73
11.85 14.00 73
11.50 13.50 73
11.00 13.50 73
11.60 13.50 73
11.55
13.50 73
11.90 14.00 73
Snd. Rate
dB
73
Indoor
1,050 [495]
1,050 [495]
1,025 [484]
1,000 [472]
1,025 [484]
[460]
1,025 [484]
1,000 [472]
1,000 [472]
[425]
1,025 [484]
1,000 [472]
1,000 [472]
1,000 [472]
1,025 [484]
[460]
1,000 [472]
1,000 [472]
1,025 [484]
1,025 [484]
1,025 [484]
1,000 [472]
1,000 [472]
1,000 [472]
1,025 [484]
1,025 [484]
1,025 [484]
1,000 [472]
Outdoor
Unit
RPNL-
Rev.
6/30/10
031JEZ
Model Numbers
Indoor Coil and/or Air Handler
RCFL-H*3617 (RGPT-05?BMK?)
RCFL-H*3617 (RGPT-07?AME?)
RCFL-H*3617 (RGRM-04?MAE?)
RCFL-H*3617 (RGRM-06?MAE?)
RCFL-H*3617 (RGRM-07?MAE?)
RCFL-H*3617 (RGRM-07?YBG?)
RCFL-H*3617 (RGTM-06?MAE?)
ROCA-070E03 (RCFL-H*3617)
ROCA-070E04 (RCFL-H*3617)
ROLA-070E03 (RCFL-H*3617)
ROLA-070E04 (RCFL-H*3617)
RCFL-H*3621
RCFL-H*3621 (RGFD-07?MCK?)
RCFL-H*3621 (RGFE-06?MCK?)
RCFL-H*3621 (RGFE-07?MCK?)
RCFL-H*3621 (RGFE-09?ZCM?)
RCFL-H*3621 (RGFE-10?ZCM?)
RCFL-H*3621 (RGGD-06?MCK?)
RCFL-H*3621 (RGGD-07?MCK?)
RCFL-H*3621 (RGGE-06?MCK?)
RCFL-H*3621 (RGGE-07?MCK?)
RCFL-H*3621 (RGGE-09?ZCM?)
RCFL-H*3621 (RGGE-10?ZCM?)
RCFL-H*3621 (RGJD-06?MCK?)
RCFL-H*3621 (RGJD-07?MCK?)
RCFL-H*3621 (RGJF-06?MCK?)
RCFL-H*3621 (RGJF-07?MCK?)
RCFL-H*3621 (RGJF-09?ZCM?)
Tot al
Capacity
BTU/H
[kW]
28,800
[8.4]
28,800
[8.4]
28,400
[8.3]
28,400
[8.3]
28,200
[8.3]
28,000
[8.2]
28,400
[8.3]
28,600
[8.4]
28,600
[8.4]
28,400
[8.3]
28,600
[8.4]
28,200
[8.3]
28,600
[8.4]
28,600
[8.4]
28,400
[8.3]
28,800
[8.4]
28,800
[8.4]
28,600
[8.4]
28,600
[8.4]
28,600
[8.4]
28,600
[8.4]
28,800
[8.4]
28,800
[8.4]
28,600
[8.4]
28,600
[8.4]
28,600
[8.4]
28,600
[8.4]
28,800
[8.4]
AHRI Heating Performance (70°F [21°C] Indoor)
CFM [L/s]
975
900
975
Outdoor Air
47°F [8.5°C] DB/
43°F [6°C] WB
DOE High Temp.
BTU/H
[kW]
26,800
[7.9]
26,600
[7.8]
26,800
[7.9]
26,800
[7.9]
27,000
[7.9]
26,800
[7.9]
26,600
[7.8]
26,400
[7.7]
26,400
[7.7]
26,400
[7.7]
26,400
[7.7]
27,000
[7.9]
26,600
[7.8]
26,600
[7.8]
26,600
[7.8]
26,400
[7.7]
26,400
[7.7]
26,600
[7.8]
26,600
[7.8]
26,600
[7.8]
26,600
[7.8]
26,400
[7.7]
26,400
[7.7]
26,600
[7.8]
26,600
[7.8]
26,600
[7.8]
26,600
[7.8]
26,400
[7.7]
COP
3.60
3.64
3.58
3.60
3.52
3.58
3.64
3.70
3.70
3.78
3.70
3.52
3.64
3.64
3.62
3.72
3.72
2.66
3.64
3.68
3.66
3.74
3.72
2.66
3.64
3.68
3.66
3.74
Outdoor Air 17°F [–8.5°C] DB/ 15°F [–9.5°C] WB
DOE Low Temp.
BTU/H
[kW]
17,400
[5.1]
17,300
[5.1]
17,500
[5.1]
17,400
[5.1]
17,700
[5.2]
17,500
[5.1]
17,400
[5.1]
17,200
[5.0]
17,200
[5.0]
17,000
[5.0]
17,200
[5.0]
17,700
[5.2]
17,300
[5.1]
17,300
[5.1]
17,400
[5.1]
17,100
[5.0]
17,100
[5.0]
17,300
[5.1]
17,300
[5.1]
17,200
[5.0]
17,300
[5.1]
17,100
[5.0]
17,100
[5.0]
17,300
[5.1]
17,300
[5.1]
17,200
[5.0]
17,300
[5.1]
17,100
[5.0]
DOE
Region
IV
HSPF
COP
2.50 9.00
2.52 9.00
2.48 9.00
2.50 9.00
2.46 9.00
2.48
9.00
2.52 9.00
2.56
9.00
2.56 9.00
2.60 9.00
2.56
9.00
2.46 9.00
2.52 9.00
2.52 9.00
2.52 9.00
2.58 9.00
2.56 9.00
2.54 9.00
2.52 9.00
2.54 9.00
2.54 9.00
2.58 9.00
2.58 9.00
2.54 9.00
2.52 9.00
2.54 9.00
2.54 9.00
2.58 9.00
Loading...