Rudd RHG PRO50-65F User Manual

Professional™Heavy Duty G
®
E
G
BA
C
F
H
HOT
WATER
CONNECTION
H
COLD
WATER
CONNECTION
D
1/2"
3/4" N.P.T.
RELIEF
VALVE
OPENING
FLUE
ANODE ROD
SIDE TAPS (48, 63, 75 & 98 GAL. MODELS ONLY)
SIDE TAPS ON
48, 63, 75 & 98 GAL. MODELS ONLY
Available in 48, 60, 63, 75 and 98 Gallon Tall Gas Models
8-Year* Limited Tank and Parts Warranty with a Professional Installation.
With ProtectionPlus™the 8-Year Limited Tank Warranty Becomes 12 Years!
the tank from corrosion
Get
4 MORE YEARS
with ProtectionPlus
uardian System
G
One-of-a-kind air/fuel shut-off device offers double
• protection Maintenance free – no filter to clean
• Standard replacement parts
Environmentally Friendly Burner
Low NOx design for low nitrous oxide emissions
Self-Cleaning (48, 60 & 63 gallon models only)
EverKleen™patented system fights sediment build-up
• Reduces fuel costs
• Provides more hot water
Easy to Light
No matches required
Energy Efficient
More hot water at low operating cost
Longer Life
Patented magnesium anode rod design incorporates
• a special resistor that protects
as Water Heaters now with the Guardian System
igh Altitude Compliant
H
All
models are certified for applications up to 7,700
• feet above sea level. Some models are certified up to 10,200 feet above sea level. Check factory for listings
Plus…
Brass drain valve and temperature and pressure relief
• valve are included Side water connections for space heating applications
• (48, 63,75 & 98 gallon models only) Meets or exceeds National Appliance Energy
• Conservation Act (NAECA) requirements
*See Residential Warranty Information Brochure
for complete warranty information.
nergy Factor and Average Annual Operating
E
osts based on D.O.E. (Department of Energy)
C
est procedures. D.O.E. national average fuel
t
ate natural gas $1.218/therm; LP $1.87/gallon
r
.
TM
T Y
GAL. THOUS. BTU/HR. G.P.H. 90° RISE DEL. G.P.H. VENT HT. DIAM. CONN. SIZE CNTR. T&P CONN. WT. FACTOR OPER. COSTS
P E
CAP. MODEL NUMBER NAT. LP NAT. LP NAT. LP AB C DE F G H(LBS) NAT. NAT.
48 RHG PRO50-65F 65 48 65.7 48.5 98 88 62-1/2 58-1/2 21-3/4 14 4 11 51-3/4 3/4 180 0.58 $315
T
60 RHG PRO60F 50 45 50.5 45.5 107 107 62 58 23 13-1/4 4848-1/2 3/4 180 0.56 $326
A
63 RHG PRO65F 65 50 65.7 50.5 115 110 65 61-1/4 23 14 4 11 54-3/4 3/4 225 0.55 $332
L L
75 RHG PRO75F 75.1 65 75.8 65.7 141 109 64 60 26-1/4 14-3/4 4 11 53-1/4 1 320 0.53† N/A
98 RHG PRO100F 75 65 75.8 65.7 135 125 67-3/4 64 27-1/4 14-3/8 4 11 57-3/16 1 350 0.49 $372
SPECIFY LP GAS WHEN ORDERING. Add “P” suffix to the model number: Example: RHG PRO100PF.
• All models are 40ng/J NOx compliant.
• All models feature the Guardian System. † Energy Factor for 75 gallon LP model.
Rheem Guardian System Features…
Exclusive Combustion Shut-off System
Should a spill incident occur, the Guardian System shuts off the gas supply and the air supply preventing a sustained vapor burn in the combustion chamber.
These units are designed to meet or exceed ANSI (American National Standards Institute) requirements and have been tested according to D.O.E. test procedures and meet or exceed the energy efficiency requirements of NAECA, ASHRAE standard 90, ICC Code and all state energy efficiency performance criteria for energy consuming appliances.
Before purchasing this appliance, read important energy cost and efficiency information available from your supplier.
Rheem Water Heaters • 101 Bell Road, Montgomery, Alabama 36117-4305 • www.rheem.com
P R I N T E D I N U . S . A 0 1 / 1 0 W P F O R M N O . 1 0 1 - 6 1 R e v. 9
DESCRIPTION FEATURES ROUGHING IN DIMENSIONS (SHOWN IN INCHES) ENERGY INFO.
GAS INPUT IN RECOVERY IN FIRST HOUR HT. TO TANK GAS VENT CONN. SIDE WATER SHIP. ENERGY AVG. ANN.
Flame Arrestor Plate
A specially-designed flame arrestor prevents ignition of vapors outside the combustion chamber.
8
For more details, see form 101-7.
Maintenance Free
Superior air filtration prevents the flame arrestor from becoming clogged by lint, dust and oil.
Y E A R L I M I T E D T A N K W A R RA N T Y
B E C O M E S
HT. TO WATER HT. TO
12
Loading...