FORM NO. G11-498 REV. 5
Supersedes Form No. G11-498 Rev. 4
RGTS- SERIES
Models with Input Rates
from 45,000 to 120,000 BTU/HR
[13.19 to 35.17 kW]
(All Models 90% A.F.U.E.† or Above)
90 HIGH EFFICIENCY
DOWNFLOW/
HORIZONTAL
GAS FURNACES
The Rheem Value Series 90 High Efficiency line of downflow/horizontal gas furnaces are designed for utility rooms,
closets, alcoves, attics or crawl spaces. The RGTS is
shipped in the downflow configuration and is easily converted for horizontal left-hand airflow applications.
The design is certified by CSA.
Features
■ Low profile “34 inch” design is lighter and easier to handle
and leaves room for optional accessories.
■ Top electrical connections, left or right gas and conden-
sate drainage connections on downflow models.
■ Condensate drain for horizontal application provided
standard.
■ Integrated control board manages all operational functions
and provides hookups for an electronic air cleaner.
■ A slow-opening gas valve and a specially designed
inducer system make it one of the quietest furnaces on
the market today.
■ Galvanized steel cabinet.
■ Optional indoor or outdoor combustion air.
■ Control board diagnostics.
A variety of cooling coils and plenums designed to use with
the Rheem Value Series 90 gas furnaces are available as
optional accessories for air conditioning models.
✝A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department
of Energy test procedures.
2 Rheem Heating, Cooling and Water Heating
STANDARD EQUIPMENT
Completely assembled and wired; heat exchanger; primary: aluminized steel,
secondary: 29-4C stainless steel; induced draft; pressure switch; redundant
main gas control; blower compartment door safety switch; solid state time
on/off blower control; limit controls; manual shut-off valve; 100% safety lock
out; cool fan off delay; field selectable heat fan off delay; one hour automatic
retry; self-test diagnostics; control diagnostics; electronic air cleaner
connections; pressure regulator for natural and L.P. (propane) gases;
transformer; direct drive, multi-speed blower motor.
(Please note: a thermostat is not included as standard equipment.)
OPTIONAL EQUIPMENT
(See Accessory Page)
All models can be converted by a qualified distributor or local service dealer to
use L.P. (propane) gas without changing burners. Factory approved kits must be
used to convert from natural to L.P. (propane) gas and may be ordered as
optional accessories from a parts distributor.
For L.P. (propane) operation, refer to Conversion Kit Index Form.
WARNING
THIS FURNACE IS NOT APPROVED
OR RECOMMENDED
FOR USE IN MOBILE HOMES
PRIMARY AND SECONDARY
HEAT EXCHANGER
REMOTE
SENSOR
DIRECT SPARK IGNITION &
REMOTE SENSOR
IN-SHOT BURNERS
PRESSURE SWITCH
DRAFT INDUCER
INTEGRATED
FURNACE
CONTROL
GAS VALVE AND
MANIFOLD
90 HIGH EFFICIENCY
DOWNFLOW/HORIZONTAL
GAS FURNACE
Rheem Heating, Cooling and Water Heating 3
MODEL IDENTIFICATION
[ ] Designates Metric Conversions
BEFORE PURCHASING THIS APPLIANCE, READ IMPORTANT ENERGY COST AND EFFICIENCY INFORMATION AVAILABLE
FROM YOUR RETAILER.
PHYSICAL DATA AND SPECIFICATIONS
DOWNFLOW/HORIZONTAL MODELS
U.S. and Canadian Models
NOTES: All models are 115V, 60HZ, 1
ø.
Gas connection size for all models is
1
/2
" [13 mm] N.P.T.
➀ See Conversion Kit Index Form for high altitude derate.
➁ Canadian installations only.
➂ In accordance with D.O.E. test procedures.
MODEL NUMBERS
RGTS- SERIES
INPUT-BTU/HR [kW] ➀
HEATING CAPACITY
BTU/HR [kW]
HIGH ALTITUDE INPUT
[kW] ➁
HIGH ALTITUDE OUTPUT
CAPACITY [kW] ➁
BLOWER (D x W)
[mm]
MOTOR H.P. [W]
SPEEDS-TYPE
MOTOR FULL LOAD AMPS 6.8 6.8 6.8 9.5 8.0 9.5
HEATING SPEED Med-Low Low Med Low Med Low
COOLING SPEED High High High High High High
HEAT EXT. STATIC PRESSURE
(IN. W.C.) [kPA]
RATED EXT. STATIC PRESSURE
(IN. W.C.) [kPA]
HEATING C.F.M. @ .2"
W.C. E.S.P. [L/s]
COOLING C.F.M. @ .5"
W.C. E.S.P. [L/s]
TEMPERATURE RISE
RANGE °F [°C]
STANDARD FILTER [mm]
APPROX. SHIPPING WEIGHT
(LBS.) [kG]
AFUE ➂
CALIFORNIA SEASONAL
EFFICIENCY ➂
04EMAES 06EMAES 07EMAES 07EYBGS 09EZAGS 10EZAJS
45,000
[13.19]
42,000
[12.31]
40,500
[11.87]
37,800
[11.07]
11 x 7
[279 x 178]
1/2 [373]
4-PSC
.10 [.025] .12 [.029] .12 [.029] .12 [.029] .15 [.037] .20 [.049]
.50 [.12] .50 [.12] .50 [.12] .50 [.12] .50 [.12] .50 [.12]
890 [420] 885 [418] 1060 [500] 1275 [602] 1400 [661] 1425 [673]
1220 [576] 1180 [557] 1150 [543] 1625 [767] 1570 [740] 1820 [859]
30-60
[16.7-33.3]
(2) 12" x 20"
[305 x 508]
111 [50.3] 117 [53.1] 123 [55.8] 123 [55.8] 148 [67.1] 152 [68.9]
92.0% 92.4% 92.0% 92.3% 92.4% 92.0%
84.35% 86.46% 89.96% 85.00% 86.40% 87.02%86.40%
60,000
[17.58]
56,000
[16.41]
54,000
[15.83]
50,400
[14.77]
11 x 7
[279 x 178]
1/2 [373]
3-PSC
40-70
[22.2-38.9]
(2) 12" x 20"
[305 x 508]
75,000
[21.98]
70,000
[20.51]
67,500
[19.78]
63,000
[18.46]
11 x 7
[279 x 178]
1/2 [373]
3-PSC
45-75
[25-41.7]
(2) 12" x 20"
[305 x 508]
75,000
[21.98]
70,000
[20.51]
67,500
[19.78]
63,000
[18.46]
12 x 7
(2) 12" x 20"
[305 x 178]
3/4 [559]
3-PSC
35-65
[19.4-36.1]
[305 x 508]
[305 x 279]
[19.4-36.1]
(2) 12" x 20"
[305 x 508]
90,000
[26.37]
84,000
[24.61]
81,000
[23.73]
76,000
[22.27]
12 x 11
1/2 [373]
3-PSC
35-65
09EZAJS
90,000
[26.37]
84,000
[24.61]
81,000
[23.73]
76,000
[22.27]
12 x 11
[305 x 279]
3/4 [559]
3-PSC
9.5
Low
High
.15 [.037]
.50 [.12]
1400 [661]
1850 [873]
35-65
[19.4-36.1]
(2) 12" x 20"
[305 x 508]
148 [67.1]
92.4%
105,000
[30.77]
97,000
[28.43]
94,500
[27.70]
87,500
[25.64]
12 x 11
[305 x 279]
3/4 [559]
3-PSC
50-80
[27.8-44.4]
(2) 12" x 20"
[305 x 508]
12ERAJS
120,000
[35.17]
113,000
[33.12]
108,000
[31.65]
100,000
[29.31]
11 x 10
[279 x 254]
3/4 [559]
3-PSC
9.5
Low
High
.20 [.049]
.50 [.12]
1565 [739]
2040 [963]
50-80
[27.8-44.4]
(2) 14" x 20"
[609 x 508]
160 [72.6]
92.1%
87.37%
G
Gas
Furnace
T = Downflow/
Condensing
S = 3rd
Design Series
R
H
E
E
M
—
Electric Ignition
Heating Input DesignationDesign Series
04E
06E
07E
09E
10E
12E
Input BTU/HR [kW]
45,000 [13.1]
60,000 [17.6]
75,000 [21.9]
90,000 [26.4]
105,000 [30.7]
120,000 [35.2]
Blower Designation [mm]
M = 11 x 7
[279 x 178]
R = 11 x 10
[279 x 254]
Y = 12 x 7
[305 x 178]
Z = 12 x 11
[305 x 279]
A
Variations
A = Std.
B = Wide
Cabinet
EM04ESTR
Heating & Cooling
Designation
E = 1100-1300(3R)
G = 1500-1700(4R)
J = 1900-2100(5R)
S
Fuel Designation
S = Natural Gas -
CSA -
United States &
Canada