Rudd RGTM-06MAES User Manual

FORM NO. G11-505 REV. 1
Supersedes Form No. G11-505
GAS FURNACES
RGTM- SERIES
ECM Equipped Models with Input Rates of 60,000, 75,000, 90,000 & 105,000 BTU/HR [17.58, 22,
95% A.F.U.E. WITH DUAL
COMFORT CONTROL
TWO-STAGE DOWNFLOW/ HORIZONTAL GAS FURNACES
The Rheem Classic®Series 95% A.F.U.E. with Dual Comfort Control
line of downflow/horizontal gas furnaces are designed for
utility rooms, closets, alcoves, or attics.
The RGTM is shipped in the downflow configuration and is easily converted for horizontal left- hand airflow applications.
The design is certified by CSA.
Features
Two stages of operation to save energy and maintain optimal com-
fort level.
Furnace operates at 70% capacity for low-heat and 100% capacity
for high-heat.
Compatible with single or two-stage thermostat. (For optimal perfor-
mance a two-stage thermostat is recommended.)
Heat exchanger is constructed of all stainless steel for maximum
corrosion resistance and thermal fatigue reliability.
Low profile “34 inch” design is lighter and easier to handle and
leaves room for optional accessories.
Left or right side gas, electric, and condensate drainage connections.
Integrated control board manages all operational functions and pro-
vides hookups for humidifier and electronic air cleaner.
An insulated blower compartment, a slow-opening gas valve and a
specially designed inducer system make it one of the quietest fur­naces on the market today.
Variable speed blower motor technology provides ultimate humidity
control, quieter sound levels and year-round energy savings.
Optional indoor or outdoor combustion air. In addition, combustion
air may be piped to either the top or side of the cabinet on all down­flow models. A special molded fitting is provided to ease installation.
Solid bottom is standard.
Control board diagnostics.
A variety of cooling coils and plenums designed to use with the Rheem
Classic
®
Series 95% A.F.U.E. gas furnaces are available as optional
accessories for air conditioning models.
A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department of Energy test
procedures.
“Visit www.Rheem.com
for complete details.”
2 Rheem Heating, Cooling and Water Heating
STANDARD EQUIPMENT
Completely assembled and wired; heat exchanger; primary: 409 stainless steel, secondary: 29-4C stainless steel; induced draft; pressure switches; redundant main gas control; blower compartment door safety switch; solid state time on/off blower control; limit controls; manual shut-off valve; 100% safety lock out; cool fan off delay; field selectable heat fan off delay; one hour automatic retry; power and self-test diagnostics; flame sense current diagnostics; electronic air cleaner connections; twinning (built-in) features; humidifier connections; humidifier on/off delay; low speed continuous fan option; single speed option for heating and cooling applications; pressure regulator for natural and L.P. (propane) gasses; transformer; direct drive, multi-speed blower motor. (Please note: a thermostat is not included as standard equipment.)
OPTIONAL EQUIPMENT
Side and bottom filter racks; return air cabinet for all sizes. NOTE: Furnace is not listed for use with fuels other than natural or L.P.
(propane) gas.
All models can be converted by a qualified distributor or local service dealer to use L.P. (propane) gas without changing burners. Factory approved kits must be used to convert from natural to L.P. (propane) gas and may be ordered as optional accessories from a parts distributor.
For L.P. (propane) operation, refer to Conversion Kit Index Form.
WARNING
THIS FURNACE IS NOT APPROVED
OR RECOMMENDED
FOR USE IN MOBILE HOMES
PRIMARY AND SECONDARY HEAT EXCHANGER
REMOTE SENSOR
DIRECT SPARK IGNITION
IN-SHOT BURNERS
ECM MOTOR
PRESSURE SWITCH
DRAFT INDUCER
INTEGRATED FURNACE CONTROL
GAS VALVE AND MANIFOLD
FUSE PROTECTION
CLASSIC®SERIES 90 PLUS HIGH EFFICIENCY DOWNFLOW/HORIZONTAL GAS FURNACE
Rheem Heating, Cooling and Water Heating 3
BEFORE PURCHASING THIS APPLIANCE, READ IMPORTANT ENERGY COST AND EFFICIENCY INFORMATION AVAILABLE FROM YOUR RETAILER.
PHYSICAL DATA AND SPECIFICATIONS— DOWNFLOW/HORIZONTAL MODELS
U.S. and Canadian Models
NOTES: All models are 115V, 60HZ, 1 phase. Gas connection size for all models is 1/2" [13 mm] N.P.T.
See Conversion Kit Index Form for high altitude derate.Canadian installations only.In accordance with D.O.E. test procedures.CFM is Nominal Value. Positive airflow adjustments will increase the Heating CFM—
See Installation Instructions. *E=Standard *N=NOx Models
[ ] Designates Metric Conversions
WARNING: Some heating airflow values may be higher than those required for cooling. Be sure to size duct systems for highest possible airflow value.
MODEL NUMBERS RGTM-06*MAES RGTM-09*ZAJS
HIGH FIRE INPUT BTU/HR [kW] LOW FIRE INPUT BTU/HR [kW] HEATING CAPACITY BTU/HR [kW] 56,000 [16.41] 84,000 [24.62]
HIGH ALTITUDE INPUT 8000' HIGH ALTITUDE OUTPUT
AT 8000' (HIGH FIRE) [kW] BLOWER (D x W)
[mm] MOTOR H.P. [W]–
SPEEDS–TYPE MOTOR FULL LOAD AMPS 8.7 12 MINIMUM EXT. STATIC
PRESSURE (IN. W.C.) [kPa] MAXIMUM EXT. STATIC
PRESSURE (IN. W.C.) [kPa] LOW HEATING CFM @ 0.2"
[0.049 kPa] W.C. E.S.P. [L/s]* HIGH HEATING CFM @ 0.2"
[0.049 kPa] W.C. E.S.P. [L/s]*
HIGH COOLING CFM @ .8" [.124 kPa] W.C. E.S.P. [L/s]
LOW COOLING CFM @ .8" [.124 kPa] W.C. E.S.P. [L/s]
TEMPERATURE RISE-HIGH FIRE RANGE IN DEGREES °F [°C]
TEMPERATURE RISE-LOW FIRE RANGE IN DEGREES °F [°C]
MAX. OUTLET AIR TEMPERATURE 170 170 165 180 RETURN AIR CABINETS (OPT.)
RXGR­FILTER SIZE [mm]
STANDARD, HIGH VELOCITY PERMANENT FILTER (IN.)
APPROX. SHIPPING WEIGHT (LBS.) [kg]
AFUE
60,000 [17.58] 90,000 [26.38] 42,000 [12.31] 63,000 [18.46]
40,800 [11.96] 61,200 [17.94]
37,944 [11.12] 56,916 [16.69]
11 x 7
[279 x 178]
1
/2 [373] VAR.
SPEED
.12 [.029] .15 [.037]
.80 [0.2] .80 [0.2]
800
[376] 1048
[493]
A = 1200 A = 2000
C = 800 C = 1400 D = 600 A = 900
C = 600 C = 1050 D = 450
35-65
[19.4-36.1]
30-60
[16.7-33.3]
C17B
(2) 12" x 16"
[305 x 406]
153/4 x 25 x 1 191/4 x 25 x 1
123
[56.0]
95.0% 95.0%
RGTM-07*RBGS
75,000 [21.98] 52,500 [15.39] 70,000 [20.51] 51,000 [14.95]
47,430 [13.90]
11 x 10
[297 x 254]
3
/4 [559] VAR.
SPEED
12
.12 [.029]
.80 [0.2]
1100
[517]
1408
[662] A = 1600 B = 1400 B = 1600B = 1000 B = 1600 C = 1200 D = 1000 D = 1200 A = 1200 B = 1050 B = 1200B = 750 B = 1200 C = 900 D = 750 D = 900
30-60
[16.7-33.3]
25-55
[13.9-30.6]
C21B
(2) 12" x 16"
[305 x 406]
153/4 x 25 x 1
139
[63.2]
95.0%
12 x 11
[305 x 279]
1 [746] VAR.
SPEED
1350
[635]
1660
[780]
D = 1200 A = 1500
D = 900
30-60
[16.7-33.3]
25-55
[13.9-30.6]
C21B
(2) 12" x 16"
[305 x 406]
148
[67.3]
RGTM-10*RBJS
105,000 [30.77]
73,500 [21.54] 97,000 [28.43] 71,400 [20.93]
66,402 [19.46]
[297 x 254]
1 [746] VAR.
[19.4-36.1]
[16.7-33.3]
(2) 14" x 16"
[609 x 406]
223/4 x 25 x 1
11 x 10
SPEED
12
.20 [.049]
.80 [0.2]
1460
[686]
1752
[823]
A = 2000
C = 1400
A = 1500
C = 1050
35-65
30-60
C29B
165 [75]
95.0%