Technical Data
Model
5350ti
6350ti
8350ti
A
38-1/2”
42-1/2”
42-1/2”
A
34-1/2”
4”
12-1/2”
4-1/4”
2-3/4”
34-1/2”
2”
W
ATER
C
ONNECTION
2-1/4”
Classic Series Heat Pump Pool Heaters
Specialty Models
Model
6350tiA42-1/2”
MODEL M6350ti-E-HC M6350ti-E-PD
Heat BTUH Output 110,000/104,000 117,000/113,000
(80,80,80)*/AHRI 1160 (80,63,80)**
C.O.P. 6.0/5.7 6.2/6.0
Compressor Scroll Scroll
Refrigerant R-410A R-410A
Voltage 208/230V-1Ph-60Hz 208/230V-1Ph-60Hz
Minimum Circuit Ampacity 42 42
Maximum Breaker Size (Amps) 60 60
Electrical Input (kw) 5.3 5.5
Heat Exchanger Titanium Titanium
Water Flow (gpm) 15-60 15-60
Shipping Weight (lbs.) 319 310
*Tested outside the scope of AHRI 1160 **Tested to AHRI 1160 All models comply with Florida 4.0 minimum C.O.P. requirement.
Model Designation
M = Rheem Brand
6 = Approximate Horsepower
3 = Classic Cabinet Design
5 = Model Revison
M6350ti-E-HC
PD = Power Defrost
HC = Heat Cool
HS = Heat System
A = Analog Control
E = Digital Contr
ti = Titanium Heat Exchanger
0 = 1 phase 208/230V
3 = 3 phase 208/230V
ol
Swimming Pool and Spa
Heating Products
Technical Data
Classic Series Heat Pump Pool Heaters
Classic Model Standard Features
Cabinet
• Exclusive DuraSteelTMPowder-Coated Cabinet
Polyester powder-coated, non-corrosive cabinet is more
durable than plastic heat pump cabinets. Same rugged
steel construction used by all the major air conditioner
manufacturers.
Evaporator Coil
Large Air Coils
•
Raised lanced-fin design maximizes heating at lower
temper
optimized to meet our specific design requirements. From
the proper fins per inch to advanced distribution
circuiting. We are the only heat pump pool heater
company to actually manufacture our own coils.
• Venturi Fan Cowling
High-capacity 3000-cfm fan provides unr
for better heating. Precision engineered and manufactured
cabinet design eliminates unwanted air gaps. This means
more air over the coil which translates to greater efficiency.
Compressor
Scroll Compressor
•
Scroll compressors are quiet and efficient compared to
piston type compressors. They provide higher efficiency,
lower sound levels, superior durability and unsurpassed
reliability. The unique design of a scroll compressor
actually wears in over time, not out!
• Sound Isolation Pads
Prevents sound transfer to equipment pad and elevates the
base pan to impr
like this that make Rheem products stand out from the
crowd.
Heat Exchanger
Spiral Titanium Tube
•
Our spiral titanium tube heat exchanger provides a
corrosion-free waterway that can withstand the abuses of
harsh pool chemistry. The spiral tube helps reduce deposit
build-up and increases efficiency by performing a “scoopand-lift” action.
• Internal Bypass Valving
Automatically compensates for normal day-to-day
changes in y
transfer efficiency.
• Plumbing Connections
Off-set 2” PVC union connections are included for ease of
installation.
atures. Rheem engineered coils are highly
estricted air flow
ove water drainage. Its the little details
our pool’s hydraulics, maximizing heat
Controls - Digital
• Pool/Spa Control
Your digital heat pump pool heater can
be set to hav
temperature for your pool and spa. This
allows you to dial in just the right spa
temperature and never have to adjust it
again. The pool can be set to a lower,
more energy saving temperature.
• Remote Compatible
The digital heat pump pool heater can
be easily contr
systems.
• On Board Diagnostics
Tells the homeo
service technician with detailed diagnostic information.
e a different target
olled by most two-wire and three-wire remote
wner if there is a problem. Provides the
Heat-Cool Models
Controls
• Heat-Cool Selector Switch
Go from heat mode to cool with a push of a button.
Refrigerant Circuit
•
Reversing Valve
Heat-Cool units have a unique reversing valve that allows
the heat pump pool heater to cool the pool water dur
hot summer months.
• Defrost
Heat-Cool units hav
forming on the condensing coil. If freezing temperatures
are sensed on the coil while heating, the unit can switch to
the cooling mode. During the cooling mode, the refrigerant
will be warmed by the pool water and send the hot gas to
the evaporator coil to melt the ice. Once the coil
temperature returns to a normal operating temperature, the
unit resumes heating the water. This process only takes
about 4 to 6 minutes to complete.
e the unique ability to prevent ice from
ing the
In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice
Swimming Pool and Spa
Heating Products
MKG-15-1511RevC
98-800-2523RevC
03-01-10