Rudd 90TJ04EES01 User Manual

Page 1
FORM NO. G11-480 REV. 9
Supersedes Form No. G11-480 Rev. 8
90TJ SERIES
Models with Input Rates from 45,000 to 120,000 BTU/HR [13.19 to 35.17 kW]
(All Models 90% A.F.U.E.† or Above)
A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department
90 HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES
The Rheem Value Series 90 High Efficiency line of down­flow/horizontal gas furnaces are designed for utility rooms, closets, alcoves, attics or crawl spaces. The 90TJ is shipped in the downflow configuration and is easily con­verted for horizontal left-hand airflow applications.
The design is certified by the CSA.
Features
Low profile “34 inch” design is lighter and easier to han-
dle and leaves room for optional accessories.
Top electrical connections, left or right gas and conden-
sate drainage connections on downflow models.
Condensate drain for horizontal application provided
standard.
Integrated control board manages all operational func-
tions and provides hookups for an electronic air cleaner.
A slow-opening gas valve and a specially designed
inducer system make it one of the quietest furnaces on the market today.
Textured galvanized steel cabinet with matching painted
access doors.
Optional indoor or outdoor combustion air.
Control board diagnostics.
A variety of cooling coils and plenums designed to use with Rheem Value Series 90 gas furnaces are available as optional accessories for air conditioning models.
Page 2
2 ICECO
STANDARD EQUIPMENT
Completely assembled and wired; heat exchanger; primary: 409 stainless steel, secondary: 29-4C stainless steel; induced draft; pressure switch; redundant main gas control; blower compartment door safety switch; solid state time on/off blower control; limit controls; manual shut-off valve; 100% safety lock out; cool fan off delay; field selectable heat fan off delay; one hour automatic retry; self-test diagnostics; control diagnostics; electronic air cleaner connections; pressure regulator for natural and L.P. (propane) gases; transformer; direct drive, multi-speed blower motor. (Please note: a thermostat is not included as standard equipment.)
OPTIONAL EQUIPMENT
(See Accessory Page)
All models can be converted by a qualified distributor or local service dealer to use L.P. (propane) gas without changing burners. Factory approved kits must be used to convert from natural to L.P. (propane) gas and may be ordered as optional accessories from a parts distributor.
For L.P. (propane) operation, refer to Conversion Kit Index Form.
WARNING
THIS FURNACE IS NOT APPROVED
OR RECOMMENDED
FOR USE IN MOBILE HOMES
PRIMARY AND SECONDARY HEAT EXCHANGER
REMOTE SENSOR
HOT SURFACE IGNITOR
IN-SHOT BURNERS
PRESSURE SWITCH
DRAFT INDUCER
INTEGRATED FURNACE CONTROL
GAS VALVE AND MANIFOLD
90 HIGH EFFICIENCY DOWNFLOW/HORIZONTAL GAS FURNACE
Page 3
ICECO 3
01SEE04TJ90
Rheem
Value Series
Fuel Code
S = 90 Plus Natural Gas
Variations
Blower Designation [mm]
Motor H.P
E = Standard Cabinet
11 x 7 [279 x 178]
1
/2 H.P. – 4 Speed
F = Standard Cabinet
12 x 7 [305 x 178]
3
/4 H.P. – 3 Speed
G = Standard Cabinet
12 x 11 [305 x 279]
3
/4 H.P. – 3 Speed
H = Standard Cabinet
11 x 10 [279 x 254]
3
/4 H.P. – 3 Speed
J = Standard Cabinet
12 x 11 [305 x 279]
1
/2 H.P. – 3 Speed
Ignition
E = Electric Ignition
Heating Input BTU/HR [kW]
04 = 45,000 [13] 06 = 60,000 [18] 07 = 75,000 [22] 09 = 90,000 [26] 10 = 105,000 [31] 12 = 120,000 [35]
Model
Designation
Efficiency
90 = 90 Plus
BEFORE PURCHASING THIS APPLIANCE, READ IMPORTANT ENERGY COST AND EFFICIENCY INFORMATION AVAILABLE FROM YOUR RETAILER.
PHYSICAL DATA AND SPECIFICATIONS
NOTES: All models are 115V, 60HZ, 1ø.Gas connection size for all models is 1/2" [13 mm] N.P.T.
See Conversion Kit Index Form for high altitude derate.Canadian installations only.In accordance with D.O.E. test procedures.
MODEL IDENTIFICATION
[ ] Designates Metric Conversions
MODEL NUMBERS
90TJ- SERIES
INPUT-BTU/HR [kW]
HEATING CAPACITY BTU/HR [kW]
HIGH ALTITUDE INPUT [kW]
HIGH ALTITUDE OUTPUT CAPACITY [kW]
BLOWER (D x W) [mm]
MOTOR H.P. [W] SPEEDS-TYPE
MOTOR FULL LOAD AMPS 6.8 6.8 6.8 9.5 9.5
HEATING SPEED Med-Low Low Med Low Low
COOLING SPEED High High High High High
HEAT EXT. STATIC PRESSURE (IN. W.C.) [kPA]
RATED EXT. STATIC PRESSURE (IN. W.C.) [kPA]
HEATING C.F.M. @ .2" W.C. E.S.P. [L/s]
COOLING C.F.M. @ .5" W.C. E.S.P. [L/s]
TEMPERATURE RISE RANGE °F [°C]
STANDARD FILTER [mm]
APPROX. SHIPPING WEIGHT (LBS.) [kG]
AFUE
CALIFORNIA SEASONAL EFFICIENCY
90TJ04EES01 90TJ06EES01 90TJ07EES01 90TJ07EFS01 90TJ10EGS01
45,000 [13.19]
42,000 [12.31]
40,500 [11.87]
37,800 [11.07]
11 x 7
[279 x 178]
1/2 [373]
4-PSC
.10 [.025] .12 [.029] .12 [.029] .12 [.029] .20 [.049]
.50 [.12] .50 [.12] .50 [.12] .50 [.12] .50 [.12]
890 [420] 885 [418] 1060 [500] 1275 [602] 1425 [673]
1220 [576] 1180 [557] 1150 [543] 1625 [767] 1820 [859]
30-60
[16.7-33.3]
(2) 12" x 20"
[305 x 508]
111 [50.3] 117 [53.1] 123 [55.8] 123 [55.8] 152 [68.9]
92.0% 92.4% 92.0% 92.3% 92.0%
84.35% 86.46% 89.96% 85.00% 87.02%
60,000 [17.58]
56,000 [16.41]
54,000 [15.83]
50,400 [14.77]
11 x 7
[279 x 178]
1/2 [373]
3-PSC
40-70
[22.2-38.9]
(2) 12" x 20"
[305 x 508]
75,000 [21.98]
70,000 [20.51]
67,500 [19.78]
63,000 [18.46]
11 x 7
[279 x 178]
1/2 [373]
3-PSC
45-75
[25-41.7]
(2) 12" x 20"
[305 x 508]
75,000 [21.98]
70,000 [20.51]
67,500 [19.78]
63,000 [18.46]
12 x 7
[305 x 178]
3/4 [559]
3-PSC
35-65
[19.4-36.1]
(2) 12" x 20"
[305 x 508]
90TJ09EJS01
90,000 [26.37]
84,000 [24.61]
81,000 [23.73]
76,000 [22.27]
12 x 11
[305 x 279]
1/2 [373]
3-PSC
8.0
Med
High
.15 [.037]
.50 [.12]
1400 [661]
1570 [740]
35-65
[19.4-36.1]
(2) 12" x 20"
[305 x 508]
148 [67.1]
92.4%
86.40%
105,000
[30.77]
97,000 [28.43]
94,500 [27.70]
87,500 [25.64]
12 x 11
[305 x 279]
3/4 [559]
3-PSC
50-80
[27.8-44.4]
(2) 12" x 20"
[305 x 508]
90TJEHS01
120,000
[35.17]
113,000
[33.12]
108,000
[31.65]
100,000
[29.31]
11 x 10
[279 x 254]
3/4 [559]
3-PSC
9.5
Low
High
.20 [.049]
.50 [.12]
1565 [739]
2040 [963]
50-80
[27.8-44.4]
(2) 14" x 20"
[609 x 508]
160 [72.6]
92.1%
87.37%
Page 4
4 ICECO
DOWNFLOW MODELS
[ ] Designates Metric Conversions
IMPORTANT NOTE: Horizontal furnace may be installed for horizontal left hand air supply ONLY. The condensate trap provided for horizontal application must be
installed in the field beneath the unit as directed in the furnace Installation & Operating Instructions.
MODEL
90TJ
04 171/2 [445] 163/8 [416] 155/8 [397] 2 [51] 165/8 [422] 137/8 [352] 0 0 0 1 [25] 2 [51] 0 111 [50]
06, 07EE
07EF
09 10 12 241/2 [622] 233/8 [594] 225/8 [575] 2 [51] 235/8 [600] 207/8 [530] 0 0 0 1 [25] 2 [51] 0 160 [73]
A B C D E F
171/2 [445] 163/8 [416] 155/8 [397] 21 [533] 197/8 [505] 193/16 [486] 21 [533] 1927/32 [504] 193/16 [486] 21 [533] 197/8 [505] 193/16 [486]
2 [51] 2 [51] 2 [51] 2 [51]
165/8 [422] 137/8 [352] 201/8 [511] 173/8 [441] 201/8 [511] 173/8 [441] 201/8 [511] 173/8 [441]
LEFT SIDE
0 0 0 1 [25] 2 [51] 0 117 [53] 0 0 0 1 [25] 2 [51] 0 123 [56] 0 0 0 1 [25] 2 [51] 0 148 [67] 0 0 0 1 [25] 2 [51] 0 152 [69]
MINIMUM CLEARANCE (IN.) [mm]
RIGHT
BACK TOP FRONT VENT
SIDE
SHIP
WGTS.
[kg]
Page 5
ICECO 5
HORIZONTAL MODELS
IMPORTANT NOTE: Horizontal furnace may be installed for horizontal left hand air supply ONLY. The condensate trap provided for horizontal application must be
installed in the field beneath the unit as directed in the furnace Installation & Operating Instructions.
[ ] Designates Metric Conversions
Page 6
6 ICECO
BLOWER PERFORMANCE DATA—90TJ MODELS
NOTE: Recommended blower speeds are in bold.
[ ] Designates Metric Conversions
MODEL
90TJ
04EES01
06EES01
07EES01
07EFS01
09EJS01
10EGS01
12EHS01
BLOWER
SIZE
IN. [mm]
11 x 7
[279 x 178]
11 x 7
[279 x 178]
11 x 7
[279 x 178]
12 x 7
[305 x 178]
12 x 11
[305 x 279]
12 x 11
[305 x 279]
11 x 10
[279 x 245]
MOTOR
H.P.
[W]
1/2
[373]
1/2
[373]
1/2
[373]
3/4
[559]
1/2
[373]
3/4
[559]
3/4
[559]
BLOWER
SPEED
LOW
MED-LO
MED-HI
HIGH
LOW
MED
HIGH
LOW
MED
HIGH
LOW
MED
HIGH
LOW
MED
HIGH
LOW
MED
HIGH
LOW
MED
HIGH
EXTERNAL STATIC PRESSURE INCHES WATER COLUMN [kPa]
0.1 [.02] 0.2 [.05] 0.3 [.07] 0.4 [.10] 0.5 [.12] 0.6 [.15] 0.7 [.17]
820 [387]
930 [439]
1150 [543] 1414 [667]
910 [429]
1115 [526] 1365 [644]
890 [420]
1100 [519]
1340 [632]
1290 [609]
1480 [698] 1705 [805]
1155 [545]
1420 [670]
1605 [757]
1460 [689]
1680 [793] 2055 [970]
1590 [750]
1840 [868] 2315 [1093]
790 [373]
890 [420]
1120 [528] 1365 [644]
885 [418]
1080 [510] 1315 [620]
860 [406]
1060 [500]
1295 [611]
1275 [602]
1435 [677] 1665 [786]
1125 [531]
1400 [661]
1575 [743]
1425 [672]
1645 [776] 2000 [944]
1565 [738]
1820 [860] 2250 [1062]
760 [359]
850 [401]
1090 [514] 1320 [622]
860 [406]
1045 [493] 1270 [600]
835 [394]
1025 [484]
1250 [590]
1260 [595]
1415 [668] 1615 [762]
1100 [519]
1380 [651]
1550 [732]
1390 [656]
1615 [762] 1940 [915]
1540 [727]
1800 [850] 2185 [1031]
CFM [L/s] AIR DELIVERY
725 [342]
815 [384]
1045 [493] 1270 [599]
815 [384]
1005 [474] 1225 [578]
790 [373]
980 [462]
1200 [566]
1220 [576]
1390 [656] 1570 [741]
1080 [510]
1365 [644]
1560 [736]
1375 [649]
1585 [748] 1880 [887]
1505 [710]
1750 [826] 2110 [996]
690 [326]
785 [370]
1002 [473] 1220 [576]
770 [363]
965 [455]
1180 [557]
750 [354]
940 [443]
1150 [543]
1195 [564]
1370 [647] 1540 [727]
1060 [500]
1350 [637]
1570 [740]
1360 [642]
1560 [736] 1820 [859]
1475 [696]
1700 [802] 2040 [963]
650 [306]
750 [354]
950 [448]
1165 [550]
725 [342]
920 [434]
1125 [491]
705 [332]
890 [420]
1090 [514]
1170 [552]
1300 [614] 1475 [696]
1000 [472]
1260 [594]
1480 [698]
1280 [604]
1490 [703] 1745 [823]
1425 [672]
1645 [776] 1965 [927]
610 [288]
720 [340]
900 [425]
1115 [526]
680 [321]
875 [413]
1070 [505]
660 [311]
845 [399]
1025 [484]
1140 [538]
1255 [592] 1400 [661]
940 [443]
1175 [554]
1395 [656]
1200 [566]
1420 [670] 1675 [790]
1375 [649]
1590 [750] 1890 [892]
Page 7
ICECO 7
GENERAL TERMS OF LIMITED WARRANTY
ICECOSMwill furnish a replacement for any part of this product which fails in normal use and service within the applicable period stated, in accordance with the terms of the limited warranty.
For Complete Details of the Limited Warranty, Including Applicable Terms and Conditions, See Your Local Installer or visit www.ICECOhvac.com.
Primary and Secondary Heat Exchanger ...Twenty (20) Years
Any Other Part ..............................................Five (5) Years
ACCESSORIES—DOWNFLOW
PLENUM DATA FOR “A” COILS
Plenum adapters are required in some applications when plenum and furnace size do not match.
VENT TERMINATION KITS CONCENTRIC: Horizontal/Vertical =RXGY-E03
HORIZONTAL TWO PIPE: RXGY-D02, RXGY-D03,
RXGY-D04, RXGY-G02
CONDENSATE PUMP KIT: RXGY-B01
NEUTRALIZER KIT: RXGY-A01
FOSSIL FUEL KIT: RXPF-F01, RXPF-F02 (TVA)
FOR HIGH ALTITUDES:
*Filter racks are shipped without filters.
RXGP-F03
TWINNING KIT—is for use with Rheem Value Series 90 Gas Furnaces
for parallel operation requirements.
Note: See Form Number C11-207 for MultiFlex®coil data.
COMBUSTIBLE FLOOR BASE: RXGC-B17, RXGC-B21, RXGC-B24 EXTERNAL TOP MOUNT FILTER RACK: RXGF-CC INTERNAL FILTER RACK FOR AIR RETURN DUCT: RXGF-DB*
Each order contains (1) one box of 10 filter racks supplied without filters. *Filters available through PROSTOCK
®
.
FURNACE
WIDTH
IN. [mm]
PLENUM
WIDTH
IN. [mm]
PLENUM ADAPTER
DOWNFLOW
COIL
PLENUM
171/2 [445] 161/4 [413] RXAA-C186 RXAL-B16BU
171/2 [445] 201/4 [514]
RXAA-C173 RXAL-B20BU
171/2 [445] 215/8 [549] RXAA-C187 RXAL-B21BU
171/2 [445] 251/4 [641] RXAA-C174 RXAL-B25BU
211/2 [533] 251/4 [641]
RXAA-C175 RXAL-B25BU
211/2 [533] 221/4 [565] RXAA-C176 RXAL-B22BU
241/2 [622] 251/4 [641]
RXAA-C177 RXAL-B25BU
241/2 [622] 215/8 [549] RXAA-C187 RXAL-B21BU
211/2 [533] 215/8 [549]
RXAA-C188 RXAL-B21BU
*For installations over 5000 ft.
OPTION CODE FOR HIGH ALTITUDE: U.S. & Canada – 278 NOTE: High altitude kits and options do NOT include additional burner
orifices. If a burner orifice change is necessary, they must be ordered through PROSTOCK
®
. See Installation Instructions for
more information.
Option – 278 furnaces are shipped with #51 DMS orifices installed. This is one drill size smaller than standard furnaces to account for expected average elevations and heating values typically seen in these areas.
CAUTION: Always follow National Fuel Gas Code (NFGC) guidelines when
converting furnaces for high altitudes.
For all installations above 2000 ft. (including all option – 278 models), the burner orifice size needs to be recalculated and verified. A burner orifice change may still be required. See Installation Instructions for more information.
NOTE: For Canadian installations only, an optional derate (manifold gas
pressure reduction) method may be used to adjust the furnace for altitude. See Installation Instructions for more information. This optional method may NOT be used for U.S. installations.
FOR LEFT SIDE (ALTERNATE) CONDENSATE DRAIN KIT:
RXGY-H01 (All Models)
[ ] Designates Metric Conversions
*HIGH ALTITUDE KIT:
F04-105 KBTU/H F06-45/60/90 KBTU/H F05-120 KBTU/H F07-75 KBTU/H
FILTER RACK FILTER SIZES®INCHES [mm]
MODEL 90TJ- RXGF-CC
04EE (2) 12 x 20 [305 x 508]
06EE (2) 12 x 20 [305 x 508]
07EE/07EF (2) 12 x 20 [305 x 508]
09EJ (2) 12 x 20 [305 x 508]
10EG (2) 12 x 20 [305 x 508]
12EH (2) 14 x 20 [305 x 508]
Page 8
“In keeping with its policy of continuous progress and product improvement, ICECO reserves the right to make changes without notice.”
PRINTED IN U.S.A. 4-07 DC FORM NO. G11-480 REV. 9
Supersedes Form No. G11-480 Rev. 8
Before proceeding with installation, refer to installation instructions packaged with each model, as well as complying with all Federal, State, Provincial, and Local codes, regulations, and practices.
RHEEM AIR CONDITIONING DIVISION
5600 Old Greenwood Road, Fort Smith, Arkansas 72908
Loading...