Fury Heavy Duty G
E
G
BA
C
F
H
HOT
WATER
CONNECTION
H
COLD
WATER
CONNECTION
D
1/2"
3/4" N.P.T.
RELIEF
VALVE
OPENING
FLUE
ANODE ROD
SIDE TAPS
(48, 63, 75
& 98 GAL.
MODELS
ONLY)
SIDE TAPS ON
48, 63, 75 & 98 GAL. MODELS ONLY
Available in 48, 60, 63, 75 and 98 Gallon Tall Gas Models
6-Year Limited Tank and Parts Warranty*
With ProtectionPlus™the 6-Year Limited Tank Warranty Becomes 10 Years!
Guardian System
ne-of-a-kind air/fuel shut-off device offers double
O
•
protection
Maintenance free – no filter to clean
Get
4 MORE YEARS
with ProtectionPlus
•
Standard replacement parts
•
Environmentally Friendly Burner
™
Low NOx design for low nitrous oxide emissions
•
Self-Cleaning (48, 60 & 63 gallon models only)
EverKleen™patented system fights sediment build-up
•
Reduces fuel costs
•
Provides more hot water
•
Easy to Light
No matches required
•
Energy Efficient
More hot water at low operating cost
•
Longer Life
Patented magnesium anode rod design incorporates
•
a special resistor that protects
as Water Heaters now with the Guardian System
™
the tank from corrosion
High Altitude Compliant
odels are certified for applications up to 7,700
ll
m
A
•
feet above sea level. Some models are certified up to
10,200 feet above sea level. Check factory for listings
Plus…
Brass drain valve and temperature and pressure relief
•
valve are included
Side water connections for space heating applications
•
(48, 63,75 & 98 gallon models only)
Meets or exceeds National Appliance Energy
•
Conservation Act (NAECA) requirements
*See Residential Warranty Information Brochure
for complete warranty information.
Energy Factor and Average Annual Operating
Costs based on D.O.E. (Department of Energy)
test procedures. D.O.E. national average fuel
rate natural gas $1.218/therm; LP $1.87/gallon
™
.
T
Y
GAL. THOUS. BTU/HR. G.P.H. 90° RISE DEL. G.P.H. VENT HT. DIAM. CONN. SIZE CNTR. T&P CONN. WT. FACTOR OPER. COSTS
P
E
CAP. MODEL NUMBER NAT. LP NAT. LP NAT. LP AB C DE F G H(LBS) NAT. NAT.
48 42V50-65F 65 48 65.7 48.5 98 88 62-1/2 58-1/2 21-3/4 14 4 11 51-3/4 3/4 180 0.58 $315
T
60 42V60F 50 45 50.5 45.5 107 107 62 58 23 13-1/4 4848-1/2 3/4 180 0.56 $326
A
63 42V65F 65 50 65.7 50.5 115 110 65 61-1/4 23 14 4 11 54-3/4 3/4 225 0.55 $332
L
L
75 42V75F 75.1 65 75.8 65.7 141 109 64 60 26-1/4 14-3/4 4 11 53-1/4 1 320 0.53† N/A
98 42V100F 75 65 75.8 65.7 135 125 67-3/4 64 27-1/4 14-3/8 4 11 57-3/16 1 350 0.49 $372
SPECIFY LP GAS WHEN ORDERING. Add “P” suffix to the model number: Example: 42V100PF.
• All models are 40ng/J NOx compliant.
• All models feature the Guardian System.
† Energy Factor for 75 gallon LP model.
Rheem Guardian System Features…
Exclusive Combustion
Shut-off System
Should a spill incident occur, the
Guardian System shuts off the
gas supply and the air supply
preventing a sustained vapor
burn in the combustion chamber.
These units are designed to meet or exceed ANSI
(American National Standards Institute) requirements and
have been tested according to D.O.E. test procedures and
meet or exceed the energy efficiency requirements of
NAECA, ASHRAE standard 90, ICC Code and all state
energy efficiency performance criteria for energy
consuming appliances.
Before purchasing this appliance, read important energy
cost and efficiency information available from your
supplier.
In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.
Rheem Water Heating • 101 Bell Road, Montgomery, Alabama 36117-4305 • www.rheem.com
P R I N T E D I N U . S . A 0 1 / 1 0 W P F O R M N O . 1 0 1 - 1 3 R e v . 1 0
DESCRIPTION FEATURES ROUGHING IN DIMENSIONS (SHOWN IN INCHES) ENERGY INFO.
GAS INPUT IN RECOVERY IN FIRST HOUR HT. TO TANK GAS VENT CONN. SIDE WATER SHIP. ENERGY AVG. ANN.
Flame Arrestor Plate
A specially-designed flame
arrestor prevents ignition of
vapors outside the
combustion chamber.
8
For more details, see form 101-7.
Maintenance Free
Superior air filtration prevents
the flame arrestor from
becoming clogged by lint,
dust and oil.
Y E A R L I M I T E D
T A N K W A R R A N T Y
B E C O M E S
HT. TO WATER HT. TO
12